Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Cobra Parsajoo is active.

Publication


Featured researches published by Cobra Parsajoo.


Talanta | 2013

Development of an acetylcholinesterase immobilized flow through amperometric detector based on thiocholine detection at a silver electrode

Cobra Parsajoo; Jean-Michel Kauffmann

This paper describes the use of a commercially available thin-layer flow through a detector with the sensing block customized in an original design for acetylcholinesterase (AChE) immobilization and suitable for inhibition studies by flow injection analysis (FI). AChE was chemically linked onto a gold disk substrate adjacent to a silver disk electrode. The downstream positioned silver electrode, poised at 0.08 V vs. Ag/AgCl, KCl 3M, permitted the sensitive amperometric detection of liberated thiocholine (TCh) using acetylthiocholine (ATCh) as enzyme substrate. A typical Michaelis-Menten curve was obtained for ATCh within the concentration range 1×10(-5)-1×10(-2)M with a Kmapp of 5.93×10(-4)M. ATCh quantification was achieved with a limit of detection (LOD) of 5.3×10(-6)M. The utility of the developed FI setup was demonstrated for AChE inhibition studies using neostigmine as model compound. The IC50 for neostigmine was obtained to be 1.45×10(-7)M.


Journal of Pharmaceutical and Biomedical Analysis | 2015

Flow-through enzyme immobilized amperometric detector for the rapid screening of acetylcholinesterase inhibitors by flow injection analysis.

Marie Vandeput; Cobra Parsajoo; Jérôme Vanheuverzwijn; Stéphanie Patris; Yavuz Yardım; Alexandre A le Jeune; Ahmad Sarakbi; Dominique Mertens; Jean-Michel Kauffmann

A commercially available thin-layer flow-through amperometric detector, with the sensing block customized in an original design, was applied to the screening of drug compounds known as acetylcholinesterase (AChE) inhibitors. AChE from electric eel was covalently immobilized onto a cysteamine modified gold disk adjacent to a silver disk working electrode. On-line studies were performed by flow injection analysis (FIA) in PBS buffer pH 7.4. Seven commercially available AChE inhibitors used in the medical field, namely neostigmine, eserine, tacrine, donepezil, rivastigmine, pyridostigmine and galantamine as well as two natural compounds, quercetin and berberine, were investigated. The same trend of inhibitory potency as described in the literature was observed. Of particular interest and in addition to the determination of the IC50 values, this flow-through system allowed the study of both, the stability of the enzyme-inhibitor complex and the kinetic of the enzyme activity recovery.


Biosensors for Medical Applications | 2012

Biosensors for drug testing and discovery

Cobra Parsajoo; Jean-Michel Kauffmann; Mohammed ElKaoutit


Sensors and Actuators B-chemical | 2017

Application of a tyrosinase microreactor – detector in a flow injection configuration for the determination of affinity and dynamics of inhibitor binding

Marie Vandeput; Stéphanie Patris; Hugo Silva; Cobra Parsajoo; Bieke Dejaeghere; Julia Arcos Martinez; Jean-Michel Kauffmann


Archive | 2016

Application d’un dispositif d’analyse par injection dans un flux comprenant un détecteur ampérométrique intégrant en amont l’enzyme immobilisée et en aval l’électrode de mesure

Marie Vandeput; Stéphanie Patris; Hugo Silva; Cobra Parsajoo; Dominique Mertens; Julia Maria Arcos-Martínez; Jean-Michel Kauffmann


Archive | 2016

Application of a tyrosinase microreactor - detector in a flow injection configuration for the determination of affinity and duration of binding of inhibitors”,

Marie Vandeput; Stéphanie Patris; Hugo Silva; Cobra Parsajoo; Bieke Dejaegher; Julia Maria Arcos-Martínez; Jean-Michel Kauffmann


Archive | 2015

Assessment of enzyme inhibitors in a flow system with electrochemical detection

Marie Vandeput; Stéphanie Patris; Cobra Parsajoo; Bieke Dejaegher; Jean-Michel Kauffmann


Archive | 2015

Application of a tyrosinase immobilized amperometric detector in a flow injection set up for the screening of enzyme inhibitors

Marie Vandeput; Stéphanie Patris; Cobra Parsajoo; Bieke Dejaegher; Jean-Michel Kauffmann


Archive | 2015

Electroanalysis in Biomedical and Pharmaceutical Sciences: Voltammetry, Amperometry, Biosensors, Applications (Monographs in Electrochemistry): Voltammetry, amperometry, biosensors, applications

Sibel A. Ozkan; Jean-Michel Kauffmann; Petr Zuman; Ana Maria Oliveira Brett; Christopher M.A. Brett; Bengi Uslu; Philippe Hubert; Eric Rozet; Cobra Parsajoo; Stéphanie Patris; Ahmad Sarakbi


Archive | 2014

Flow-through enzyme immobilized detector for the rapid screening of acetylcholinesterase inhibitors

Marie Vandeput; Cobra Parsajoo; Jean-Michel Kauffmann

Collaboration


Dive into the Cobra Parsajoo's collaboration.

Top Co-Authors

Avatar

Jean-Michel Kauffmann

Université libre de Bruxelles

View shared research outputs
Top Co-Authors

Avatar

Marie Vandeput

Université libre de Bruxelles

View shared research outputs
Top Co-Authors

Avatar

Stéphanie Patris

Université libre de Bruxelles

View shared research outputs
Top Co-Authors

Avatar

Bieke Dejaegher

Université libre de Bruxelles

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ahmad Sarakbi

Université libre de Bruxelles

View shared research outputs
Top Co-Authors

Avatar

Dominique Mertens

Université libre de Bruxelles

View shared research outputs
Top Co-Authors

Avatar

Alexandre A le Jeune

Université libre de Bruxelles

View shared research outputs
Top Co-Authors

Avatar

Bieke Dejaeghere

Université libre de Bruxelles

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge