American Journal of Neuroradiology | 2008

Diagnostic Accuracy of CT Angiography with Matched Mask Bone Elimination for Detection of Intracranial Aneurysms: Comparison with Digital Subtraction Angiography and 3D Rotational Angiography

M. Romijn; H. A. F. Gratama van Andel; M.A. van Walderveen; Marieke E.S. Sprengers; J. van Rijn; W.J. van Rooij; Henk W. Venema; Cornelis A. Grimbergen; G. J. den Heeten; C. B. Majoie

BACKGROUND AND PURPOSE: Our aim was to determine the diagnostic accuracy of multisection CT angiography combined with matched mask bone elimination (CTA-MMBE) for detection of intracranial aneurysms compared with digital subtraction angiography (DSA) and 3D rotational angiography (3DRA). MATERIALS AND METHODS: Between January 2004 and February 2006, 108 patients who presented with clinically suspected subarachnoid hemorrhage underwent both CTA-MMBE and DSA for diagnosis of an intracranial aneurysm. Two neuroradiologists, independently, evaluated 27 predefined vessel locations in the CTA-MMBE images for the presence of an aneurysm. After consensus, diagnostic accuracy of CTA was calculated per predefined location and per patient. Interobserver agreement was calculated with κ statistics. RESULTS: In 88 patients (81%), 117 aneurysms (82 ruptured, 35 unruptured) were present on DSA. CTA-MMBE detected all ruptured aneurysms except 1. Overall specificity, sensitivity, positive predictive value, and negative predictive value of CTA-MMBE were 0.99, 0.90, 0.98, and 0.95 per patient and 0.91, 1.00, 0.97, and 0.99 per location, respectively. Sensitivity was 0.99 for aneurysms ≥3 mm and 0.38 for aneurysms <3 mm. Interobserver agreement for aneurysm detection was excellent (κ value of 0.92 per location and 0.80 per patient). CONCLUSION: CTA-MMBE is accurate in detecting intracranial aneurysms in any projection without overprojecting bone. CTA-MMBE has limited sensitivity in detecting very small aneurysms. Our data suggest that DSA and 3DRA can be limited to the vessel harboring the ruptured aneurysm before endovascular treatment, after detection of a ruptured aneurysm with CTA.


Circulation | 1993

Localization of the site of origin of postinfarction ventricular tachycardia by endocardial pace mapping. Body surface mapping compared with the 12-lead electrocardiogram

A SippensGroenewegen; Hans Spekhorst; N. M. Van Hemel; J. H. Kingma; R. N. W. Hauer; J. M. T. de Bakker; Cornelis A. Grimbergen; Michiel J. Janse; Arend J. Dunning

BackgroundThe purpose of this study was to assess the value of body surface mapping and the standard 12-lead ECG in localizing the site of origin of postinfarction ventricular tachycardia (VT) during endocardial pace mapping of the left ventricle. summary Background. The purpose of this study was to assess the value of body surface mapping and the standard 12-lead ECG in localizing the site of origin of postinfarction ventricular tachycardia (VT) during endocardial pace mapping of the left ventricle. Methods and ResultsSimultaneous recordings of 62-lead body surface QRS integral maps and scalar 12-lead ECG tracings were obtained in 16 patients with prior myocardial infarction during a total of 26 distinct VT configurations and during subsequent left ventricular catheter pace mapping at 9 to 24 different endocardial sites. Anatomic pacing site locations were computed by means of a biplane cineradiographic method and plotted on a polar projection of the left ventricle. The QRS integral map and the QRS complexes of the 12 standard leads of eachVT morphology obtained in a particular patient were compared independently with the different paced QRS integral maps and paced QRS complexes of the 12-lead ECG generated in that same patient. The stimulus site locations of the best matching paced QRS integral map and paced QRS complexes of the 12-lead ECG were indicated on the polar projection and subsequently compared with the endocardial location of the corresponding site ofVT origin identified during intraoperative (surgical ablation) or catheter activation sequence mapping (catheter ablation). The localization resolution of pace mapping was established separately for each electrocardiographic technique by computing the size of endocardial areas with similar morphological features of the QRS complex. Pace mapping advocated with body surface mapping or the 12-lead ECG enabled adequate reproduction of the VT QRS morphology in 24 of 26 VTs (92%) and 25 of 26 VTs (96%), respectively. Activation sequence mapping identified the site of origin in 12 of 26 previously observedVT configurations (46%). Ten and 11 VTs were localized by activation sequence mapping and pace mapping combined with body surface mapping or the 12-lead ECG, respectively. Pace mapping applied with body surface mapping identified the site of origin correctly (distance .2 cm) in 8 of 10 compared VTs (80%); an adjacent site (distance between 2 and 4 cm) or a disparate site (distance >4 cm) was identified in the remaining 2 of 10 VTs (20%). Pace mapping used with the 12-lead ECG localized the site of origin correctly in 2 of 11 VTs (18%); the site of origin was identified correctly next to an additional adjacent site in 5 of 11 VTs (55%); and an adjacent site or a disparate site was found in 1 of 11 VTs (9%vo) and 2 of 11 VTs (18%), respectively. The difference in localization accuracy of both electrocardiographic techniques was statistically significant (P=.02). The mean size of endocardial areas where a comparable QRS morphology was obtained during pace mapping was 6.0±4.5 cm2 with the application of body surface mapping and 15.1±12.0 cm2 with the use of the 12-lead ECG. ConclusionsThese results demonstrate that application of the 62-lead instead of the 12-lead ECG during endocardial pace mapping enhances the localization resolution of this mapping technique and enables more precise identification of the site of arrhythmogenesis in the majority of compared postinfarctionVT episodes.


Medical Physics | 2004

Removal of bone in CT angiography of the cervical arteries by piecewise matched mask bone elimination

Marcel van Straten; Henk W. Venema; Geert J. Streekstra; Charles B. L. M. Majoie; Gerard J. den Heeten; Cornelis A. Grimbergen

In maximum intensity projection (MIP) images of CT angiography (CTA) scans, the arteries are often obscured by bone. A bone removal method is presented that uses an additional, nonenhanced scan to create a mask of the bone by thresholding and dilation. After registration of the CTA scan and the additional scan, the bone in the CTA scan is masked. As the cervical area contains bones that can move with respect to each other, these bones are separated first using a watershed algorithm, and then registered individually. A phantom study was performed to evaluate and quantify the tradeoff between the removal of the bone and the preservation of the arteries contiguous to the bone. The influence of algorithm parameters and scan parameters was studied. The method was clinically evaluated with data sets of 35 patients. Best results were obtained with a threshold of 150 HU and a dilation of 8 in-plane voxels and two out-of-plane voxels. The mean width of the soft tissue layer, which is also masked, was approximately 1 mm. The mAs value of the nonenhanced scan could be reduced from 250 mAs to 65 mAs without a loss of quality. In 32 cases the bones were registered correctly and removed completely. In three cases the bone separation was not completely successful, and consequently the bone was not completely removed. The piecewise matched mask bone elimination method proved to be able to obtain MIP images of the cervical arteries free from overprojecting bone in a fully automatic way and with only a slight increase of radiation dose.


IEEE Transactions on Biomedical Engineering | 2011

Computer-Assisted Planning and Navigation for Corrective Distal Radius Osteotomy, Based on Pre- and Intraoperative Imaging

Johannes G. G. Dobbe; Simon D. Strackee; Albert Wilhelm Schreurs; R. Jonges; Bart Carelsen; Joy C. Vroemen; Cornelis A. Grimbergen; Geert J. Streekstra

Malunion after a distal radius fracture is very common and if symptomatic, is treated with a so-called corrective osteotomy. In a traditional distal radius osteotomy, the radius is cut at the fracture site and a wedge is inserted in the osteotomy gap to correct the distal radius pose. The standard procedure uses two orthogonal radiographs to estimate the two inclination angles and the dimensions of the wedge to be inserted into the osteotomy gap. However, optimal correction in 3-Dspace requires restoring three angles and three displacements. This paper introduces a new technique that uses preoperative planning based on 3-D images. Intraoperative 3-D imaging is also used after inserting pins with marker tools in the proximal and distal part of the radius and before the osteotomy. Positioning tools are developed to correct the distal radius pose in six degrees of freedom by navigating the pins. The method is accurate (derr <; 1.2 mm, φerr <; 0.9°, mTRE = 1.7 mm), highly reproducible (SEd <; 1.0 mm, SEφ ≤ 1.4°, SEmTRE = 0.7 mm), and allows intraoperative evaluation of the end result. Small incisions for pin placement and for the osteotomy render the method minimally invasive.


Minimally Invasive Therapy & Allied Technologies | 1997

Force transmission of laparoscopic grasping instruments

W. Sjoerdsma; Just L. Herder; M. J. Horward; A. Jansen; J. J. G. Bannenberg; Cornelis A. Grimbergen

SummaryIn laparoscopic surgery, grasping instruments are used to manipulate tissue. These instruments are the only means of contact between tissue and the surgeons hand. With well designed instruments, the pinching force on the hand should be a reliable measurement for the grasping force on the jaws. To evaluate this transmission of information by the mechanisms of existing grasping instruments, measurements and calculations were carried out. It was found that due to mechanical friction losses and variations in the transmission of forces over the working range, the information transmission is far from ideal. Ways to improve the transmission of information, by adjusting existing instruments or by designing alternative concepts, are indicated.


Journal of the American College of Cardiology | 1994

Value of body surface mapping in localizing the site of origin of ventricular tachycardia in patients with previous myocardial infarction

A. SippensGroenewegen; Hans Spekhorst; Norbert M. van Hemel; J. Herre Kingma; Richard N.W. Hauer; Jacques M.T. de Barker; Cornelis A. Grimbergen; Michiel J. Janse; Arend J. Dunning

OBJECTIVES This study examined the performance of the 62-lead body surface electrocardiogram (ECG) in identifying the site of origin of ventricular tachycardia in patients with a previous myocardial infarction. BACKGROUND Because the accuracy of ECG localization of ventricular tachycardia using standard 12-lead recordings is restricted to the identification of rather large ventricular areas, application of multiple torso lead recordings may augment the resolving power of the surface ECG and result in more discrete localization of arrhythmogenic foci. METHODS Thirty-two patients were selected for electrophysiologically guided ablative therapy for drug-resistant postinfarction ventricular tachycardia. In these patients, QRS integral maps of distinct monomorphic ventricular tachycardia configurations were correlated with a previously generated infarct-specific reference data base of paced QRS integral maps. Each paced pattern in the data base corresponded with ectopic endocardial impulse formation at 1 of 18 or 22 discrete segments of the left ventricle with a previous anterior or inferior myocardial infarction, respectively. Electrocardiographic localization was compared with the results obtained during intraoperative or catheter endocardial activation sequence mapping. RESULTS Body surface mapping was performed during 101 distinct ventricular tachycardia configurations. Compared with the activation mapping data that were acquired in 64 of 101 ventricular tachycardias, body surface mapping identified the correct segment of origin in 40 (62%) of 64 tachycardias, a segment adjacent to the segment where the arrhythmia actually originated in 19 (30%) of 64 tachycardias and a segment disparate from the actual segment of origin in 5 (8%) of 64 tachycardias. With respect to infarct location, the segment of origin was correctly identified in 28 (60%) of 47 ventricular tachycardias in patients with anterior, 7 (70%) of 10 tachycardias in patients with inferior and 5 (71%) of 7 tachycardias in patients with combined anterior and inferior myocardial infarction. CONCLUSIONS This study shows that body surface mapping enables precise localization of the origin of postinfarction ventricular tachycardia in 62% and regional approximation in 30% of tachycardias. The multiple-lead ECG may be used to guide and shorten catheter-based mapping procedures during ventricular tachycardia and to provide relevant information on the origin of tachycardias that cannot be mapped with conventional single-site mapping techniques because of unfavorable characteristics.


Circulation | 1995

Association of Left Ventricular Remodeling and Nonuniform Electrical Recovery Expressed by Nondipolar QRST Integral Map Patterns in Survivors of a First Anterior Myocardial Infarction

Jan-Henk E. Dambrink; Arne SippensGroenewegen; Wiek H. van Gilst; Kathinka Peels; Cornelis A. Grimbergen; J. Herre Kingma

BACKGROUND Progressive left ventricular dilatation after myocardial infarction is associated with a high mortality rate, the majority of which is arrhythmogenic in origin. The underlying mechanism of this relation remains unknown. It has been suggested, however, that left ventricular dilatation is accompanied by changes in repolarization characteristics that may facilitate the occurrence of life-threatening ventricular arrhythmias. METHODS AND RESULTS We examined 62-lead body surface QRST integral maps during sinus rhythm in 78 patients at 349 +/- 141 days after thrombolysis for a first anterior myocardial infarction. Visual map analysis was directed at discriminating dipolar (uniform repolarization) from nondipolar (nonuniform repolarization) patterns. In addition, the nondipolar content of each map was assessed quantitatively with the use of eigenvector analysis. Nondipolar map patterns were present in almost one third of the patients (32%). Left ventricular end-systolic and end-diastolic volumes were assessed echocardiographically before discharge and after 3 and 12 months with the use of the modified biplane Simpson rule. The increase in left ventricular end-systolic volume 1 year after myocardial infarction was more pronounced in patients with nondipolar QRST integral map patterns (14.47 +/- 14.10 versus 4.22 +/- 8.44 mL/m2, P = .017). In patients with an increase in end-systolic volume of more than 16 mL/m2 (upper quartile), the prevalence of nondipolar maps was 89% compared with 29% in patients with dilatation of less than 16 mL/m2. In addition, the nondipolar content of maps in patients in the upper quartile was significantly increased compared with the lower quartiles (49 +/- 14% versus 37 +/- 12%, P = .013). Logistic regression analysis revealed that an end-systolic volume of more than 42 mL/m2 after 1 year contributed independently to the appearance of nondipolar maps. Patients with high-grade ventricular arrhythmias showed a higher nondipolar content (49 +/- 17% versus 39 +/- 10%, P = .013). QTc dispersion did not discriminate between patients with and those without high-grade ventricular arrhythmias. Also, the association between left ventricular remodeling and nondipolar map patterns was confirmed prospectively in an additional group of 15 patients. CONCLUSIONS Nondipolar map patterns are present in 32% of patients after thrombolysis for a first anterior myocardial infarction and are associated with increased left ventricular dilatation. These data support the hypothesis that left ventricular dilatation after myocardial infarction leads to changes in repolarization characteristics that may facilitate the occurrence of life-threatening ventricular arrhythmias.


IEEE Transactions on Biomedical Engineering | 1994

Automatic QRS onset and offset detection for body surface QRS integral mapping of ventricular tachycardia

Jurgen G. C. Kemmelings; Andrk C. Linnenbank; Sylvia L. C. Muilwijk; Arne SippensGroenewegen; Abraham Peper; Cornelis A. Grimbergen

A QRS onset and offset detection algorithm has been developed for use in body surface QRS integral mapping of ventricular tachycardia. To determine QRS intervals, the algorithm uses two computed signals: the sum of the absolute values of the first derivatives of all leads and the sum of the absolute values of all leads. The second order derivative of the latter parameter is used to detect the time instants of QRS onset and offset. Using the algorithm, QRS integral maps are subsequently computed, which are correlated with a database of QRS integral maps in order to localize the site of origin of ventricular tachycardia. Comparison of the performance of the algorithm with visual evaluation by a human expert in this procedure revealed, in 95% of the cases, an identical or adjacent localization of the site of origin.<<ETX>>


European Journal of Radiology | 2015

Towards personalized compression in mammography: a comparison study between pressure- and force-standardization.

Jerry E. de Groot; W. Branderhorst; Cornelis A. Grimbergen; Gerard J. den Heeten; Mireille J. M. Broeders

OBJECTIVE To compare a conventional 14 decanewton (daN) force-standardized compression protocol with a personalized 10kilopascal (kPa) pressure-standardized protocol. METHODS A new add-on contact area detector, which enables pressure-standardized compression, is validated in a double-blinded intra-individual comparison study. Breast screening participants (433) received one craniocaudal (CC) and one mediolateral oblique (MLO) compression for both breasts. Three of these compressions were force-standardized, and one, blinded and randomly assigned, was pressure-standardized. Participants scored their pain experience on an 11-point numerical rating scale (NRS). Three experienced breast-screening radiologists, blinded for compression protocol, indicated which images required retakes. RESULTS An unanticipated under-compression issue that occurred at forces below 5daN was effectively solved with minimal extra radiographer training during the study. For pressure-standardized compressions obtained at 5daN or more, the compressed breasts thickness increased on average 4.2% (MLO)-6.3% (CC), average pain scores were reduced by 10% (MLO)-17% (CC) and the proportion of women experiencing severe pain (NRS≥7) was reduced by 27% (MLO)-32% (CC), compared with force-standardized compressions (all p-values <0.05). Average glandular dose (AGD) and proportions of retakes were similar for both protocols. CONCLUSION Pressure-standardized compressions resulted in AGD values and a retake proportion similar to force-standardized compressions, while pain was significantly reduced.


European Journal of Radiology | 2015

Mammographic compression – A need for mechanical standardization

W. Branderhorst; Jerry E. de Groot; Ralph Highnam; Ariane Chan; Marcela Böhm-Vélez; Mireille J. M. Broeders; Gerard J. den Heeten; Cornelis A. Grimbergen

BACKGROUND A lack of consistent guidelines regarding mammographic compression has led to wide variation in its technical execution. Breast compression is accomplished by means of a compression paddle, resulting in a certain contact area between the paddle and the breast. This procedure is associated with varying levels of discomfort or pain. On current mammography systems, the only mechanical parameter available in estimating the degree of compression is the physical entity of force (daN). Recently, researchers have suggested that pressure (kPa), resulting from a specific force divided by contact area on a breast, might be a more appropriate parameter for standardization. Software has now become available which enables device-independent cross-comparisons of key mammographic metrics, such as applied compression pressure (force divided by contact area), breast density and radiation dose, between patient populations. PURPOSE To compare the current compression practice in mammography between different imaging sites in the Netherlands and the United States from a mechanical point of view, and to investigate whether the compression protocols in these countries can be improved by standardization of pressure (kPa) as an objective mechanical parameter. MATERIALS AND METHODS We retrospectively studied the available parameters of a set of 37,518 mammographic compressions (9188 women) from the Dutch national breast cancer screening programme (NL data set) and of another set of 7171 compressions (1851 women) from a breast imaging centre in Pittsburgh, PA (US data set). Both sets were processed using VolparaAnalytics and VolparaDensity to obtain the applied average force, pressure, breast thickness, breast volume, breast density and average glandular dose (AGD) as a function of the size of the contact area between the breast and the paddle. RESULTS On average, the forces and pressures applied in the NL data set were significantly higher than in the US data set. The relative standard deviation was larger in the US data set than in the NL data set. Breasts were compressed with a force in the high range of >15 daN for 31.1% and >20 kPa for 12.3% of the NL data set versus, respectively, 1.5% and 1.7% of the US data set. In the low range we encountered compressions with a pressure of <5 daN for 21.1% and <5 kPa for 21.7% of the US data set versus, respectively, 0.05% and 0.6% in the NL data set. Both the average and the standard deviation of the AGD were higher in the US data set. CONCLUSION (1) Current mammographic breast compression policies lead to a wide range of applied forces and pressures, with large variations both within and between clinical sites. (2) Pressure standardization could decrease variation, improve reproducibility, and reduce the risk of unnecessary pain, unnecessary high radiation doses and inadequate image quality.

Collaboration


Dive into the Cornelis A. Grimbergen's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jenny Dankelman

Delft University of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Henk G. Stassen

Delft University of Technology

View shared research outputs
Top Co-Authors

Avatar

Frans M. Vos

Delft University of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

A. Peper

University of Amsterdam

View shared research outputs
Top Co-Authors

Avatar

C. B. Majoie

University of Amsterdam

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge