Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Corrado Cescon is active.

Publication


Featured researches published by Corrado Cescon.


Biological Cybernetics | 2002

Influence of anatomical, physical and detection system parameters on surface EMG

Dario Farina; Corrado Cescon; Roberto Merletti

Abstract. Many previous studies were focused on the influence of anatomical, physical, and detection-system parameters on recorded surface EMG signals. Most of them were conducted by simulations. Previous EMG models have been limited by simplifications which did not allow simulation of several aspects of the EMG generation and detection systems. We recently proposed a model for fast and accurate simulation of the surface EMG. It characterizes the volume conductor as a non-homogeneous and anisotropic medium, and allows simulation of EMG signals generated by finite-length fibers without approximation of the current-density source. The influence of thickness of the subcutaneous tissue layers, fiber inclination, fiber depth, electrode size and shape, spatial filter transfer function, interelectrode distance, length of the fibers on surface, single-fiber action-potential amplitude, frequency content, and estimated conduction velocity are investigated in this paper. Implications of the results on electrode positioning procedures, spatial filter design, and EMG signal interpretation are discussed.


IEEE Transactions on Biomedical Engineering | 2001

Concentric-ring electrode systems for noninvasive detection of single motor unit activity

Dario Farina; Corrado Cescon

New recording techniques for detecting surface electromyographic (EMG) signals based on concentric-ring electrodes are proposed in this paper. A theoretical study of the two-dimensional (2-D) spatial transfer function of these recording systems is developed both in case of rings with a physical dimension and in case of line rings. Design criteria for the proposed systems are presented in relation to spatial selectivity. It is shown that, given the radii of the rings, the weights of the spatial filter can be selected in order to improve the rejection of low spatial frequencies, thus increasing spatial selectivity. The theoretical transfer functions of concentric systems are obtained and compared with those of other detection systems. Signals detected with the ring electrodes and with traditional one-dimensional and 2-D systems are compared. The concentric-ring systems show higher spatial selectivity with respect to the traditional detection systems and reduce the problem of electrode location since they are invariant to rotations. The results shown are very promising for the noninvasive detection of single motor unit (MU) activities and decomposition of the surface EMG signal into the constituent MU action potential trains.


Digestion | 2004

Multichannel Surface EMG for the Non-Invasive Assessment of the Anal Sphincter Muscle

Roberto Merletti; A. Bottin; Corrado Cescon; Dario Farina; Marco Gazzoni; Simone Martina; Luca Mesin; Marco Pozzo; Alberto Rainoldi; Paul Enck

Background/Aims: This work focuses on recording, processing and interpretation of multichannel surface EMG detected from the external anal sphincter muscle. The aim is to describe the information that can be extracted from signals recorded with such a technique. Methods: The recording of many signals from different locations on a muscle allows the extraction of additional information on muscle physiology and anatomy with respect to that obtained by classic bipolar recordings. Multichannel EMG methods have been recently developed for the assessment of the external anal sphincter. An anal probe was used in this study to record signals at different depths within the anal canal during contractions at different effort levels. The plug is 150 mm in length and 14 mm in diameter, holding a circumferential array of 16 equally spaced silver bar electrodes, located at a distance of 20 mm from the probe tip and aligned with the probe axis. Results: Information about localization of the innervation zone, fiber length, EMG amplitude, muscle fiber conduction velocity and single motor unit analysis can be obtained from the signals recorded with the circumferential array by means of innovative signal processing techniques. Conclusions: The type of information extracted from multichannel surface EMG signals cannot be obtained with other currently available techniques. The technological innovation described in this work is promising for a further insight into the investigation of pelvic floor pathologies and rehabilitation treatments.


Journal of Electromyography and Kinesiology | 2009

A bi-dimensional index for the selective assessment of myoelectric manifestations of peripheral and central muscle fatigue.

Luca Mesin; Corrado Cescon; Marco Gazzoni; Roberto Merletti; Alberto Rainoldi

Two physiological factors are assumed in this paper to mainly determine the myoelectric manifestations of fatigue: (1) the decrease of the conduction velocity (CV) of motor unit action potentials (MUAP) (peripheral fatigue), and (2) the increase of MU synchronization by the central nervous system (central fatigue). To describe separately the peripheral and central components of the myoelectric manifestations of fatigue, we investigated the following indexes: (1) mean spectral frequency - MNF, (2) median spectral frequency - MDF, (3) root mean square - RMS, (4) average rectified value - ARV, (5) estimation of muscle fiber conduction velocity - ECV, (6) percentage of determinism - %DET, (7) spectral indexes defined as the ratio between signal spectral moments - FI(k), (8) MNF estimated by autoregressive analysis - MNF(AR), (9) MNF estimated by Choi-Williams time-frequency representation - MNF(CWD), (10) MNF estimated by continuous wavelet transform - MNF(CWT), (11) signal entropy - S, (12) fractal dimension - FD. The indexes were tested with a set of synthetic EMG signals, with different CV distribution and level of MU synchronization. The indexes were calculated on epochs of 0.5s. It was observed that ECV is uncorrelated with the level of simulated synchronization (promising index of peripheral fatigue). On the other hand FD was the index least affected by CV changes and most related to the level of synchronism (promising index of central fatigue). A representative application to some experimental signals from vastus lateralis muscle during an isometric endurance test supported the results of the simulations. The vector (ECV, FD) is suggested to provide selective indications of peripheral and central fatigue. The description of EMG fatigue by a bi-dimensional vector opens new perspectives in the assessment of muscle properties, with potential application in both clinical and sport sciences.


Journal of Neurophysiology | 2008

Amplitude cancellation of motor-unit action potentials in the surface electromyogram can be estimated with spike-triggered averaging.

Dario Farina; Corrado Cescon; Francesco Negro; Roger M. Enoka

The study presents analytical, simulation, and experimental analyses of amplitude cancellation of motor-unit action potentials (APs) in the interference electromyogram (EMG) and its relation to the size of the spike-triggered average (STA) EMG. The amount of cancellation of motor-unit APs decreases monotonically as a function of the ratio between the root mean square (RMS) of the motor-unit AP and the RMS of the interference EMG signal. The theoretical derivation of this association indicates a method to measure cancellation in individual motor units by STA of the interference and squared EMGs. The theoretical relation was examined in both simulated EMG signals generated by populations of 200 motor units and experimental recordings of 492 and 184 motor-unit APs in the vastus medialis and abductor digiti minimi muscles, respectively. Although the theoretical relation predicted (R2 = 0.95; P < 0.001) the amount of cancellation in the simulated EMGs, the presence of motor-unit synchronization decreased the strength of the association for small APs. The decrease in size of the STA obtained from the squared EMG relative to that extracted from the interference EMG was predicted by the experimental measure of cancellation (R2 = 0.65; P < 0.001, for vastus medialis; R2 = 0.26; P < 0.05, for abductor digiti minimi). The results indicate that cancellation of APs in the interference EMG can be analytically predicted and experimentally measured with STA from the discharge times of the motor units into the surface EMG.


Medical & Biological Engineering & Computing | 2004

Effect of accelerometer location on mechanomyogram variables during voluntary, constant-force contractions in three human muscles.

Corrado Cescon; Dario Farina; Massimiliano Gobbo; Roberto Merletti; Claudio Orizio

To understand better the features of the mechanomyogram (MMG) with different force levels and muscle architectures, the MMG signals detected at many points along three muscles were analysed by the application of a linear array of MMG sensors (up to eight) over the skin. MMG signals were recorded from the biceps brachii, tibialis anterior and upper trapezius muscles of the dominant side of ten healthy male subjects. The accelerometers were aligned along the direction of the muscle fibres. One accelerometer was located over the distal muscle innervation zone, and the other six or seven accelerometers were placed over the muscle, forming an array of sensors with fixed distances between them. The array covered almost the entire muscle length in all cases. MMG signals detected from adjacent accelerometers had similar shapes, with correlation coefficients ranging from about 0.5 to about 0.9. MMG amplitude and characteristic spectral frequencies significantly depended on accelerometer location. The MMG amplitude was maximum at the muscle belly for the biceps brachii and the tibialis anterior. Higher MMG characteristic spectral frequencies were associated with higher amplitudes in the case of the biceps brachii, whereas the opposite was observed for the tibialis anterior muscle. In the upper trapezius, the relationship between characteristic spectral frequencies, MMG amplitude and contraction force depended on the accelerometer location. This suggested that MMG spectral features do not only reflect the mechanical properties of the recruited muscle fibres but depend on muscle architecture and motor unit territorial distribution. It was concluded that the location of the accelerometer can have an influence on both amplitude and spectral MMG features, and this dependence should be considered when MMG signals are used for muscle assessment.


Journal of Manual & Manipulative Therapy | 2012

Intra-rater reliability of an experienced physiotherapist in locating myofascial trigger points in upper trapezius muscle

Marco Barbero; Paolo Bertoli; Corrado Cescon; Fiona Macmillan; Fiona Coutts; Roberto Gatti

Abstract Objectives: Myofascial trigger points (MTrPs) are considered the principal clinical feature of myofascial pain syndrome (MPS). An MTrP consists of spot tenderness within a taut band of muscle fibers and its stimulation can produce both local and referred pain. The clinical diagnosis of MPS depends on correct history taking and a physical examination aimed at identifying the presence of MTrP. The purpose of this study was to investigate the intra-rater reliability of a palpation protocol used for locating an MTrP in the upper trapezius muscle. Methods: Twenty-four subjects with MTrP in the upper trapezius muscle were examined by an experienced physiotherapist. During each of eight experimental sessions, subjects were examined twice in randomized order using a palpation protocol. An anatomical landmark system was defined and the MTrP location established using X and Y values. Results: The intraclass correlation coefficient ICC(1,1) values were 0·62 (95% CI: 0·30–0·81) for X and 0·81 (95% CI: 0·61–0·91) for Y. The Bland–Altman plots for X and Y showed a mean of difference of 0·04 and −0·2 mm, respectively. Limits of agreement for X ranged from −26·3 to 26·2 mm and for Y from −27 to 26·4 mm. Discussion: The ICC(1,1) for the observed values revealed a moderate to high correlation and the Bland–Altman analysis showed means of difference very close to zero with narrow limits of agreement. An experienced physiotherapist can reliably identify MTrP locations in upper trapezius muscle using a palpation protocol.


Journal of Neuroscience Methods | 2006

Spatial and force dependency of mechanomyographic signal features.

Pascal Madeleine; Corrado Cescon; Dario Farina

The aim was to investigate with a novel technique the spatial inhomogeneity in surface mechanomyographic (MMG) response to muscle contraction at varying force levels. MMG signals were detected over the dominant tibialis anterior muscle of 10 volunteers using a 5 x 3 grid of accelerometers. The subjects performed 3 s long isometric contractions at forces ranging from 0% to 100% of the maximal force (10% increment) in a randomised order. From the two-dimensional MMG recordings, maps of absolute and normalized temporal and spectral MMG descriptors were obtained. The centroid and entropy of these maps were computed to describe the spatial centre of activity and degree of homogeneity, respectively. MMG absolute amplitude did not depend on location over the muscle while normalized amplitude did and the centroid shifted with increasing force. Amplitude increased with force and its entropy decreased. Absolute and normalized spectral variables depended on location over the muscle and their centroid shifted with increasing force. In addition, the dependency of absolute and normalized spectral variables on force was affected by location. These results highlight limitations when using single-channel MMG features for the assessment of motor unit control strategies, due to a substantial effect of position on the relation between force and MMG characteristics.


PLOS ONE | 2015

Evaluation of Central and Peripheral Fatigue in the Quadriceps Using Fractal Dimension and Conduction Velocity in Young Females

Matteo Beretta-Piccoli; Giuseppe D’Antona; Marco Barbero; Beth E. Fisher; Christina M. Dieli-Conwright; Ron Clijsen; Corrado Cescon

Purpose Over the past decade, linear and non-linear surface electromyography descriptors for central and peripheral components of fatigue have been developed. In the current study, we tested fractal dimension (FD) and conduction velocity (CV) as myoelectric descriptors of central and peripheral fatigue, respectively. To this aim, we analyzed FD and CV slopes during sustained fatiguing contractions of the quadriceps femoris in healthy humans. Methods A total of 29 recreationally active women (mean age±standard deviation: 24±4 years) and two female elite athletes (one power athlete, age 24 and one endurance athlete, age 30 years) performed two knee extensions: (1) at 20% maximal voluntary contraction (MVC) for 30 s, and (2) at 60% MVC held until exhaustion. Surface EMG signals were detected from the vastus lateralis and vastus medialis using bidimensional arrays. Results Central and peripheral fatigue were described as decreases in FD and CV, respectively. A positive correlation between FD and CV (R=0.51, p<0.01) was found during the sustained 60% MVC, probably as a result of simultaneous motor unit synchronization and a decrease in muscle fiber CV during the fatiguing task. Conclusions Central and peripheral fatigue can be described as changes in FD and CV, at least in young, healthy women. The significant correlation between FD and CV observed at 60% MVC suggests that a mutual interaction between central and peripheral fatigue can arise during submaximal isometric contractions.


Journal of Neuroscience Methods | 2007

Two-dimensional spatial distribution of surface mechanomyographical response to single motor unit activity

Corrado Cescon; Pascal Madeleine; Thomas Graven-Nielsen; Roberto Merletti; Dario Farina

In order to better understand the mechanisms of generation of mechanomyography (MMG) signals, the two-dimensional distribution of surface MMG produced by the activity of single motor units was analyzed by a novel two-dimensional recording method. Motor unit action potentials were identified from intramuscular electromyographic (EMG) signals and used to trigger the averaging of MMG signals detected over the tibialis anterior muscle of 11 volunteers with a grid of 5x3 accelerometers (20-mm inter-accelerometer distance). The intramuscular wires were inserted between the first and second accelerometer in the middle column of the grid, proximal to the innervation zone. The subjects performed three contractions with visual feedback of the intramuscular EMG signals. In each contraction, a new motor unit was recruited at the minimum stable discharge rate (mean+/-S.D., N = 11 subjects, 7.3+/-2.3 pulse/s), resulting in torque of 2.4+/-2.8% of the maximal voluntary contraction (MVC), 4.6+/-2.7% MVC, and 6.3+/-3.1% MVC (all different, P < 0.01). For 23 out of 33 detected motor units, it was possible to extract the motor unit surface acceleration map (MUAM). A negative MUAM peak (-2.7+/-2.2 mm/s2) was detected laterally and a positive MUAM peak (4.1+/-2.4 mm/s2) medially (P < 0.001). The time-to-peak was shorter in the medial part of the muscle (2.9+/-0.4 ms) than in the other locations (3.4+/-0.5 ms, P < 0.001). The double integrated signals (muscle displacement) indicated negative deflection in the lateral part and inflation close to the tibia bone. The maps of acceleration showed spatial dependency in single motor unit MMG activities. The technique provides a new insight into motor unit contractile properties.

Collaboration


Dive into the Corrado Cescon's collaboration.

Top Co-Authors

Avatar

Dario Farina

Imperial College London

View shared research outputs
Top Co-Authors

Avatar

Deborah Falla

University of Birmingham

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Roberto Gatti

Vita-Salute San Raffaele University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Erik Cattrysse

Vrije Universiteit Brussel

View shared research outputs
Researchain Logo
Decentralizing Knowledge