Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where D.D. Hinshelwood is active.

Publication


Featured researches published by D.D. Hinshelwood.


Physics of Plasmas | 2001

Theoretical modeling and experimental characterization of a rod-pinch diode

G. Cooperstein; J.R. Boller; R.J. Commisso; D.D. Hinshelwood; D. Mosher; P. F. Ottinger; J.W. Schumer; S. J. Stephanakis; S.B. Swanekamp; B.V. Weber; F.C. Young

The rod-pinch diode consists of an annular cathode and a small-diameter anode rod that extends through the hole in the cathode. With high-atomic-number material at the tip of the anode rod, the diode provides a small-area, high-yield x-ray source for pulsed radiography. The diode is operated in positive polarity at peak voltages of 1 to 2 MV with peak total electrical currents of 30–70 kA. Anode rod diameters as small as 0.5 mm are used. When electrode plasma motion is properly included, analysis shows that the diode impedance is determined by space-charge-limited current scaling at low voltage and self-magnetically limited critical current scaling at high voltage. As the current approaches the critical current, the electron beam pinches. When anode plasma forms and ions are produced, a strong pinch occurs at the tip of the rod with current densities exceeding 106 A/cm2. Under these conditions, pinch propagation speeds as high as 0.8 cm/ns are observed along a rod extending well beyond the cathode. Even f...


IEEE Transactions on Plasma Science | 1987

Plasma Erosion Opening Switch Research at NRL

B.V. Weber; R.J. Commisso; G. Cooperstein; J. M. Grossmann; D.D. Hinshelwood; David Mosher; Jesse M. Neri; P. F. Ottinger; S. J. Stephanakis

This paper is a review of plasma erosion opening switch (PEOS) research performed at the Naval Research Laboratory (NRL). Several experimental and theoretical results are described to illustrate the present level of understanding and the best switching results obtained to date. Significant power multiplication has been achieved on the Gamble II generator, producing 3.5 TW with less than 10-ns rise time. Switching after nearly 1-¿s conduction time has been demonstrated on Pawn, producing a 0.2-TW 100-ns pulse. Scaling the switch to higher current, power, and conduction time should be possible based on theoretical analysis and the favorable results of scaling experiments performed thus far.


Physics of fluids. B, Plasma physics | 1992

Characterization of a microsecond-conduction-time plasma opening switch

R.J. Commisso; P.J. Goodrich; J. M. Grossmann; D.D. Hinshelwood; P. F. Ottinger; B.V. Weber

This paper presents data and analyses from which emerges a physical picture of microsecond‐conduction‐time plasma opening switch operation. During conduction, a broad current channel penetrates axially through the plasma, moving it toward the load. Opening occurs when the current channel reaches the load end of the plasma, far from the load. During conduction, the axial line density in the interelectrode region is reduced from its value with no current conduction as a result of radial hydrodynamic forces associated with the current channel. A factor of 20 reduction is observed at opening in a small, localized region between the electrodes. When open, the switch plasma behaves like a section of magnetically insulated transmission line with an effective gap of 2 to 3 mm. Increasing the magnetic field in this gap by 50% results in an improvement of 50% in the peak load voltage and load current rise time, to 1.2 MV and 20 nsec, respectively. An erosion opening mechanism explains the inferred gap growth rate using the reduced line density at opening. Improved switch performance results when the maximum gap size is increased by using a rising load impedance.This paper presents data and analyses from which emerges a physical picture of microsecond‐conduction‐time plasma opening switch operation. During conduction, a broad current channel penetrates axially through the plasma, moving it toward the load. Opening occurs when the current channel reaches the load end of the plasma, far from the load. During conduction, the axial line density in the interelectrode region is reduced from its value with no current conduction as a result of radial hydrodynamic forces associated with the current channel. A factor of 20 reduction is observed at opening in a small, localized region between the electrodes. When open, the switch plasma behaves like a section of magnetically insulated transmission line with an effective gap of 2 to 3 mm. Increasing the magnetic field in this gap by 50% results in an improvement of 50% in the peak load voltage and load current rise time, to 1.2 MV and 20 nsec, respectively. An erosion opening mechanism explains the inferred gap growth rate u...


IEEE Transactions on Plasma Science | 1991

Investigation of plasma opening switch conduction and opening mechanisms

B.V. Weber; R.J. Commisso; Phillip Goodrich; J. M. Grossmann; D.D. Hinshelwood; James C. Kellogg; Paul F. Ottinger

Plasma opening switch techniques have been developed for pulsed power applications to exploit the advantages of electrical energy storage in a vacuum inductor compared to conventional, capacitive-based energy storage. Experiments are described that demonstrate the successful application of these techniques in conduction time ranges from 50 ns to over 1 mu s. Physics understanding of the conduction and opening mechanisms is far from complete; however, many insights have been gained from experiments and theory. Measurements of current distribution, plasma density, and ion emission indicate that conduction and opening mechanisms differ for the 50 ns and 1 mu s conduction times. For the 50 ns conduction time case, switching begins at a current level close to the bipolar emission limit, and opening could occur primarily by erosion. In the 1 mu s conduction time case, limited hydrodynamic plasma displacement implies far higher plasma density than is required by the bipolar emission limit. Magnetic pressure is required to augment erosion to generate the switch gap inferred from experiments. >


Physics of Plasmas | 1995

Plasma opening switch conduction scaling

B.V. Weber; R.J. Commisso; P.J. Goodrich; J. M. Grossmann; D.D. Hinshelwood; P. F. Ottinger; S.B. Swanekamp

Plasma opening switch (POS) experiments performed on the Hawk generator [Commisso et al., Phys. Fluids B 4, 2368 (1992)] (750 kA, 1.2 μs) determine the dependence of the conduction current and conduction time on plasma density, electrode dimensions, and current rise rate. The experiments indicate that for a range of parameters, conduction is controlled by magnetohydrodynamic (MHD) distortion of the plasma, resulting in a low density region where opening can occur, possibly by erosion. The MHD distortion corresponds to an axial translation of the plasma center‐of‐mass by half the initial plasma length, leading to a simple scaling relation between the conduction current and time, and the injected plasma density and POS electrode dimensions that is applicable to a large number of POS experiments. For smaller currents and conduction times, the Hawk data suggest a non‐MHD conduction limit that may correspond to electromagnetohydrodynamic (EMH) field penetration through the POS plasma.


Physics of Plasmas | 2004

Ultra-high electron beam power and energy densities using a plasma-filled rod-pinch diode

B.V. Weber; R.J. Commisso; G. Cooperstein; D.D. Hinshelwood; D. Mosher; P. F. Ottinger; D. M. Ponce; J.W. Schumer; S. J. Stephanakis; S. Strasburg; S.B. Swanekamp; F.C. Young

The plasma-filled rod-pinch diode is a new technique to concentrate an intense electron beam to high power and energy density. Current from a pulsed power generator (typically ∼MV, MA, 100 ns pulse duration) flows through the injected plasma, which short-circuits the diode for 10–70 ns, then the impedance increases and a large fraction of the ∼MeV electron-beam energy is deposited at the tip of a 1 mm diameter, tapered rod anode, producing a small (sub-mm diameter), intense x-ray source. The current and voltage parameters imply 20–150 μm effective anode-cathode gaps at the time of maximum radiation, much smaller gaps than can be used between metal electrodes without premature shorting. Interferometric diagnostics indicate that the current initially sweeps up plasma in a snowplow-like manner, convecting current toward the rod tip. The density distribution is more diffuse at the time of beam formation with a low-density region near the rod surface where gap formation could occur. Particle simulations of the...


IEEE Transactions on Plasma Science | 2002

Experimental evaluation of a megavolt rod-pinch diode as a radiography source

R.J. Commisso; G. Cooperstein; D.D. Hinshelwood; David Mosher; Paul F. Ottinger; S. J. Stephanakis; Stephen Brian Swanekamp; B.V. Weber; F.C. Young

The rod-pinch diode is a cylindrical pinched-beam diode that provides an intense pulsed small-diameter bremsstrahlung source for radiography. For this work, the diode consists of a 1- to 6.4-mm-diameter anode rod that extends through the hole of an annular cathode. After exiting the cathode, wider anodes taper down to a 1 mm diameter. All of the anode rods then have a 1-mm-diameter tungsten tip that is usually tapered to a point. Rod-pinch diodes with anode rods of different materials, lengths, and diameters were powered by the Gamble II generator at peak voltages of 1.0 to 1.8 MV and peak currents of 30 to 60 kA. The radiation was characterized with temporally and spatially resolved X-ray diagnostics. Pinhole-camera images and time-resolved pin-diode measurements indicate that the radiation is emitted primarily from the vicinity of the rod tip. The dose measured with thermoluminescent detectors through a plexiglass transmission window ranges from 0.6 to 2.8 R at 1 m from the rod tip and the dose/charge scales faster than linearly with the diode voltage. The full-width at half-maximum (FWHM) of the radiation pulse is 30 to 50 ns. The size of the radiation source-is determined by measuring its edge spread function. The source diameter, defined here as the FWHM of the derivative of the edge spread function, decreases from 2 mm for a 6.4-mm-diameter rod to 1 mm or less for a 1-mm-diameter rod. Analysis suggests that the central portion of the radiation distribution at the source can be approximated by a uniformly radiating circular disc.


Applied Physics Letters | 1986

Long conduction time plasma erosion opening switch experiment

D.D. Hinshelwood; J.R. Boller; R.J. Commisso; G. Cooperstein; Robert A. Meger; J. M. Neri; Paul F. Ottinger; B.V. Weber

A plasma erosion opening switch, coupled to a small capacitor bank, conducts 120 kA for 400 ns before opening in 40 ns. Voltages above 170 kV are produced through the use of an electron beam diode. These voltages exceed the initial capacitor bank voltage by a factor of 4. Current and magnetic field measurements indicate that the same current conduction and opening processes observed in earlier erosion switch experiments are involved here at tenfold greater conduction times, verifying the current controlled nature of plasma erosion switch operation.


IEEE Transactions on Plasma Science | 1988

Development of a sodium-pump/neo-lasant photopumped soft X-ray laser

S.J. Stephenakis; J. P. Apruzese; P. G. Burkhalter; G. Cooperstein; J. Davis; D.D. Hinshelwood; G. Mehlman; David Mosher; P. F. Ottinger; V. E. Scherrer; J.W. Thornhill; B.L. Welch; F.C. Young

An intense source of sodium pump-line radiation has been created and used to photopump a neon plasma for application to a pulsed-power driven sodium/neo X-ray laser. Properties of the sodium-pump plasma and the neon-lasant plasma required to optimize fluorescence and lasing are determined. The implosion of a sodium-bearing plasma with a megampere pulsed-power driver (Gamble II) is used to produce a linear Z-pinch with up to 25 GW of sodium-pump-line radiation. A separate neon plasma, driven by part of the return current from the imploding sodium plasma, is created parallel to the sodium line source at a distance of 5 cm. Evidence for population inversion is indicated by fluorescence enhancement of the 11-AA resonance line from the n=4 level of neon when pumped by sodium. >


IEEE Transactions on Plasma Science | 1997

Interferometry of flashboard and cable-gun plasma opening switches on Hawk

B.V. Weber; D.D. Hinshelwood; R.J. Commisso

Interferometry of plasma opening switch (POS) plasmas on the Hawk generator has shown many important features of the plasma evolution during conduction and opening. Opening occurs when a low-density region forms at a radial location determined by plasma redistribution during the conduction phase, consistent with J/spl times/B forces and the measured plasma distributions produced by the sources alone. High neutral densities have been detected in the POS region during conduction. Low-density plasma appears between the POS and the load at the time current appears in the load, and high-density plasmas appear there later in time. There are two important differences between the density evolution of POSs utilizing flashboard and cable-gun plasma sources. 1) There is a substantial (two-three times) increase in the electron inventory during conduction using cable guns that is not detected using flashboards. This is attributed, primarily, to ionization of ions and neutrals for the cable-gun case. 2) The conduction scaling with plasma density implies that the cable-gun POS has an effective ion mass/charge ratio about double that for the flashboard POS.

Collaboration


Dive into the D.D. Hinshelwood's collaboration.

Top Co-Authors

Avatar

B.V. Weber

United States Naval Research Laboratory

View shared research outputs
Top Co-Authors

Avatar

R.J. Commisso

United States Naval Research Laboratory

View shared research outputs
Top Co-Authors

Avatar

P. F. Ottinger

United States Naval Research Laboratory

View shared research outputs
Top Co-Authors

Avatar

J.W. Schumer

United States Naval Research Laboratory

View shared research outputs
Top Co-Authors

Avatar

F.C. Young

United States Naval Research Laboratory

View shared research outputs
Top Co-Authors

Avatar

S. J. Stephanakis

United States Naval Research Laboratory

View shared research outputs
Top Co-Authors

Avatar

G. Cooperstein

United States Naval Research Laboratory

View shared research outputs
Top Co-Authors

Avatar

D. Mosher

United States Naval Research Laboratory

View shared research outputs
Top Co-Authors

Avatar

S.B. Swanekamp

United States Naval Research Laboratory

View shared research outputs
Top Co-Authors

Avatar

R.J. Allen

United States Naval Research Laboratory

View shared research outputs
Researchain Logo
Decentralizing Knowledge