Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where D.H. Morse is active.

Publication


Featured researches published by D.H. Morse.


Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms | 1989

Ion microbeam tomography

A.E. Pontau; Arlyn J. Antolak; D.H. Morse; A.A. Ver Berkmoes; J.M. Brase; D.W. Heikkinen; H.E. Martz; I.D. Proctor

Abstract Proton beams with energies of 5 and 7 MeV are focused to 5 μm and used to produce tomograms of capillary tubes and low-density foams. In this energy range, proton energy loss is primarily due to interactions with electrons. Therefore, by measuring the residual energy of protons transmitted through samples in a manner similar to that used for Scanning Transmission Ion Microscopy (STIM), and reconstructing a cross-sectional image from multiple projections, we can map out spatial variations in electron density due to sample geometry and composition. In our experimental arrangement, the sample is translated and rotated in a stationary proton beam. Transmitted proton energies are measured using a silicon surface barrier detector. Tomographie reconstructions are produced from the calculated line-average densities using a procedure based on a filtered backprojection algorithm developed for X-ray computed tomography (CT) systems. The technique is especially useful in characterizing samples where large variations in Z or low total density limit the applicability of X-ray CT analysis.


Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms | 1990

Some practical considerations for ion microtomography

A.E. Pontau; Arlyn J. Antolak; D.H. Morse

Abstract Spatial broadening and energy straggling of the analysis beam can dictate the choice of ion species and required fluence for given spatial and density resolution in ion microtomography (IMT). For extended objects, fine spatial resolution also implies huge data sets. Data acquisition, reduction, and reconstruction rates must be maximized to achieve optimal materials analysis times. In this paper, we discuss these topics and current efforts in this field, present examples of IMT, and consider future directions.


Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms | 1999

The stand-alone microprobe at Livermore

M.L. Roberts; Patrick G. Grant; Graham Bench; Thomas A. Brown; Brian R. Frantz; D.H. Morse; Arlyn J. Antolak

Lawrence Livermore National Laboratory (LLNL) and Sandia National Laboratories/California have jointly constructed a new stand-alone microprobe facility. Although the facility was built to develop a method to rapidly locate and determine elemental concentrations of micron scale particulates on various media using PIXE, the facility has found numerous applications in biology and materials science. The facility is located at LLNL and uses a General Ionex Corporation Model 358 duoplasmatron negative ion source, a National Electrostatics Corporation 5SDH-2 tandem accelerator, and an Oxford triplet lens. Features of the system include complete computer control of the beam transport using LabVIEW TM for Macintosh, computer controlled beam collimating and divergence limiting slits, automated sample positioning to micron resolution, and video optics for beam positioning and sample observation. Data collection is accomplished with the simultaneous use of as many as four EG&G Ortec IGLET-X TM X-Ray detectors, digital amplifiers made by X-Ray Instruments and Associates (XIA), and LabVIEW TM for Macintosh acquisition software.


Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms | 1991

Minimum data set requirements for ion microtomography

A.E. Pontau; Arlyn J. Antolak; D.H. Morse

Abstract Data acquisition and analysis rates and data set size seriously affect the practicality of conducting ion microtomography studies that map out material densities of extended objects in three dimensions. For the promise of todays fine spatial resolution capabilities to be met, huge data sets must be acquired, processed, and analyzed efficiently. In this paper, we present the results of an experimental parametric study exploring the limits of minimizing the amount of data required for tomographic reconstruction. We consider data acquisition system resolution and the effect of limited accuracy of stopping powers. We show graphically the specific results of variation of parameters affecting minimum data set size.


IEEE Transactions on Nuclear Science | 1997

Mapping high-pressure Bridgman Cd/sub 0.8/Zn/sub 0.2/Te

M. Schieber; H. Hermon; R. B. James; J.C. Lund; Arlyn J. Antolak; D.H. Morse; N. N. Kolesnikov; Yu. N. Ivanov; M. S. Goorsky; J.M. Van Scyoc; H. Yoon; J. Toney; T.E. Schlesinger; F. P. Doty; J. P. D. Cozzatti

Single crystals of Cd/sub 0.8/Zn/sub 0.2/Te grown at the Institute of Solid State Physics, Chernogolovka, Russia, by the high-pressure vertical Bridgman method (HPVB) were mapped using X-ray fluorescence (XRF), X-ray diffraction (XRD), photoluminescence (PL), and leakage current measurements, most of the Russian samples which we refer to as p-type CZT were more uniform in Zn composition than U.S. commercially produced material. The Russian material had a poorer crystallinity and, in the best case, could only count nuclear radiation. Differences in the material properties between Russian (p-type) and U.S. (n-type) material will be described.


Journal of Electronic Materials | 1996

Material inhomogeneities in Cd 1−x Zn x Te and their effects on large volume gamma-ray detectors

J.M. Van Scyoc; J.C. Lund; D.H. Morse; Arlyn J. Antolak; Richard W. Olsen; R. B. James; M. Schieber; H. Yoon; M. S. Goorsky; J. Toney; T. E. Schlesinger

Cadmium zinc telluride (Cd1−x ZnxTe or CZT) has shown great promise as a material for room temperature x-ray and gamma-ray detectors. In particular, polycrystalline material grown by the high pressure Bridgman method with nominal Zn fraction (x) from 0.1 to 0.2 has been used to fabricate high resolution gamma-ray spectrometers with resolution approaching that of cooled high-purity Ge. For increased sensitivity, large areas (> 1 cm2) are required, and for good sensitivity to high energy gamma photons, thick detectors (on the order of 1 cm) are required. Thus, there has been a push for the development of CZT detectors with a volume greater than 1 cm3. However, nonuniformities in the material over this scale degrade the performance of the detectors. Variations in the zinc fraction, and thus the bandgap, and changes in the impurity distributions, both of which arise from the selective segregation of elements during crystal growth, result in spectral distortions. In this work, several materials characterization techniques were combined with detector evaluations to determine the materials properties limiting detector performance. Materials measurements were performed on detectors found to have differing performance. Measurements conducted include infrared transmission, particle induced x-ray emission, photoluminescence, and triaxial x-ray diffraction. To varying degrees, these measurements reveal that “poor-performance” detectors exhibit higher nonuniformities than “spectrometer-grade” detectors. This is reasonable, as regions of CZT material with different properties will give different localized spectral responses, which combine to result in a degraded spectrum for the total device.


Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms | 1995

Microbeam PIXE analysis using wavelength dispersive spectrometry

D.H. Morse; Graham Bench; Stewart P.H.T. Freeman; A.E. Pontau

Wavelength dispersive X-ray spectrometry (WDS) offers significant advantages over energy dispersive X-ray spectrometry for PIXE analysis in some situations. Compared with energy dispersive Si(Li) detectors, the better energy resolution of WDS results in better separation of closely spaced adjacent X-ray peaks and enhanced signal to background ratios. These can result in greater accuracy in quantitative analysis, and increased sensitivity for trace element analysis. In addition, it is possible to analyze elements from beryllium upwards (Z ≥ 4). We have installed a commercial WDS detector on a nuclear microprobe system located at Lawrence Livermore National Laboratory. Advantages and limitations of wavelength dispersive spectrometry and considerations for calibration and operation are discussed. Representative results are presented for micro-PIXE analysis.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1994

Density and composition analysis using focused MeV ion mubeam techniques

Arlyn J. Antolak; Graham Bench; A.E. Pontau; D.H. Morse; D.W. Heikkinen; D.L. Weirup

Abstract Nuclear muscopy uses focused MeV ion mubeams to non-destructively characterize materials and components with mun scale spatial resolution. Although a number of accelerator-based mubeam methods are available for materials analysis, this paper centers on the techniques of Ion mutomography (IMT) and Particle-Induced X-ray Emission (PIXE). IMT provides quantitative three-dimensional density information with mun-scale spatial resolution and 1% density variation sensitivity. Recently, IMT has become more versatile because greater emphasis has been placed on understanding the effects of reconstruction artifacts, beam spatial broadening, and limited projection data sets. PIXE provides quantitative elemental information with detection sensitivities to 1 μg/g or below in some instances. By scanning the beam, two-dimensional maps of elemental concentration can also be recorded. However, since X-rays are produced along the entire path of the ion beam as it penetrates the sample, these measurements only give depth-averaged information in general. PIXE tomography (PIXET) is the natural extension from conventional PIXE analysis to the full three-dimensional measurement and forms the bridge linking the complementary techniques of PIXE and IMT. This paper presents recent developments and applications of these ion beam techniques in a diverse range of fields including characterizing metal-matrix composites, biological specimens and inertial confinement fusion targets.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1998

Homogeneity of CdZnTe detectors

H. Hermon; M. Schieber; R. B. James; J.C. Lund; Arlyn J. Antolak; D.H. Morse; N. N. Kolesnikov; Yu. N. Ivanov; M. S. Goorsky; H. Yoon; J. Toney; T. E. Schlesinger

Abstract We describe the current state of nuclear radiation detectors produced from single crystals of Cd 1− x Zn x Te(CZT), with 0.04 x


MRS Proceedings | 1997

Lead Iodide X-Ray and Gamma-Ray Spectrometers for Room and High Temperature Operation

H. Hermon; R. B. James; J.C. Lund; E. Cross; Arlyn J. Antolak; D.H. Morse; D.L Medlin; E. Soria; J.M. Van Scyoc; B. A. Brunett; M. Schieber; T.E. Schlesinger; J. Toney; M. S. Goorsky; H. Yoon; Arnold Burger; L. Salary; K.-T. Chen; Y.-C. Chang; K. Shah

In this study the authors report on the results of the investigation of lead iodide material properties. The effectiveness of a zone refining purification method on the material purity is determined by ICP-MS and ICP-OES and correlated to the electrical and physical material properties. They show that this zone refining method is very efficient in removing impurities from lead iodide, and they also determine the segregation coefficient for some of these impurities. Triple axis X-ray diffraction (TAD) analysis has been used to determine the crystalline perfection of the lead iodide after applying various cutting, etching and fabrication methods. The soft lead iodide crystal was found to be damaged when cleaved by a razor blade, but by using a diamond wheel saw, followed by etching, the crystallinity of the material was much improved, as observed by TAD. Low temperature photoluminescence also indicates an improvement in the material properties of the purified lead iodide. Electrical properties of lead iodide such as carrier mobility, were calculated based on carrier-phonon scattering. The results for the electrical properties were in good agreement with the experimental data.

Collaboration


Dive into the D.H. Morse's collaboration.

Top Co-Authors

Avatar

Arlyn J. Antolak

Sandia National Laboratories

View shared research outputs
Top Co-Authors

Avatar

Graham Bench

Lawrence Livermore National Laboratory

View shared research outputs
Top Co-Authors

Avatar

R. B. James

Sandia National Laboratories

View shared research outputs
Top Co-Authors

Avatar

A.E. Pontau

Sandia National Laboratories

View shared research outputs
Top Co-Authors

Avatar

M. S. Goorsky

University of California

View shared research outputs
Top Co-Authors

Avatar

M. Schieber

Hebrew University of Jerusalem

View shared research outputs
Top Co-Authors

Avatar

H. Yoon

University of California

View shared research outputs
Top Co-Authors

Avatar

J. Toney

Carnegie Mellon University

View shared research outputs
Top Co-Authors

Avatar

D.W. Heikkinen

Lawrence Livermore National Laboratory

View shared research outputs
Top Co-Authors

Avatar

J.C. Lund

Sandia National Laboratories

View shared research outputs
Researchain Logo
Decentralizing Knowledge