Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where D. Impiombato is active.

Publication


Featured researches published by D. Impiombato.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2015

Characterization and performance of the ASIC (CITIROC) front-end of the ASTRI camera

D. Impiombato; Salvatore Giarrusso; T. Mineo; O. Catalano; C. Gargano; G. La Rosa; F. Russo; G. Sottile; S. Billotta; G. Bonanno; S. Garozzo; A. Grillo; D. Marano; G. Romeo

Abstract The Cherenkov Imaging Telescope Integrated Read Out Chip, CITIROC, is a chip adopted as the front-end of the camera at the focal plane of the imaging Cherenkov ASTRI dual-mirror small size telescope (ASTRI SST-2M) prototype. This paper presents the results of the measurements performed to characterize CITIROC tailored for the ASTRI SST-2M focal plane requirements. In particular, we investigated the trigger linearity and efficiency, as a function of the pulse amplitude. Moreover, we tested its response by performing a set of measurements using a silicon photomultiplier (SiPM) in dark conditions and under light pulse illumination. The CITIROC output signal is found to vary linearly as a function of the input pulse amplitude. Our results show that it is suitable for the ASTRI SST-2M camera.


IEEE Transactions on Nuclear Science | 2014

Silicon Photomultipliers Electrical Model Extensive Analytical Analysis

D. Marano; G. Bonanno; S. Billotta; A. Grillo; S. Garozzo; G. Romeo; O. Catalano; G. La Rosa; G. Sottile; D. Impiombato; Salvatore Giarrusso

The present work aims to address a comprehensive analytical analysis of a new accurate equivalent electrical model of silicon photomultiplier (SiPM) detectors. The proposed circuit model allows to truthfully reproduce the output signal waveform generated by the light sensors apart from the specific technology adopted for the fabrication process, and can also be profitably exploited to perform reliable circuit-level simulations. A detailed and in-depth investigation of the functional parameters involved in the output pulse signals is here developed, and the most significant physical relationships are analytically derived as well. Experimental measurements are finally carried out on real devices, in order to validate the accuracy of the attained expressions, and good fittings are achieved between the analytical curve plots and the associated measurements results. The adopted analysis turns out to be particularly helpful when designing an optimum front-end architecture for SiPM detectors, since the performance of the entire detection system, especially in terms of dynamic range and timing resolution, can be accurately predicted as a function of the SiPM model parameters and the foremost features of the coupled front-end electronics.


arXiv: Instrumentation and Methods for Astrophysics | 2013

UVSiPM: A light detector instrument based on a SiPM sensor working in single photon counting

G. Sottile; F. Russo; G. Agnetta; S. Billotta; B. Biondo; G. Bonanno; O. Catalano; Salvatore Giarrusso; A. Grillo; D. Impiombato; G. La Rosa; Maria Concetta Maccarone; A. Mangano; D. Marano; T. Mineo; A. Segreto; E. Strazzeri; M.C. Timpanaro

Abstract UVSiPM is a light detector designed to measure the intensity of electromagnetic radiation in the 320–900 nm wavelength range. It has been developed in the framework of the ASTRI project whose main goal is the design and construction of an end-to-end Small Size class Telescope prototype for the Cherenkov Telescope Array. The UVSiPM instrument is composed by a multipixel Silicon Photo-Multiplier detector unit coupled to an electronic chain working in single photon counting mode with 10 nanosecond double pulse resolution, and by a disk emulator interface card for computer connection. The detector unit of UVSiPM is of the same kind as the ones forming the camera at the focal plane of the ASTRI prototype. Eventually, the UVSiPM instrument can be equipped with a collimator to regulate its angular aperture. UVSiPM, with its peculiar characteristics, will permit to perform several measurements both in lab and on field, allowing the absolute calibration of the ASTRI prototype.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2013

Characterization of EASIROC as Front-End for the readout of the SiPM at the focal plane of the Cherenkov telescope ASTRI

D. Impiombato; Salvatore Giarrusso; T. Mineo; S. Billotta; G. Bonanno; O. Catalano; A. Grillo; G. La Rosa; D. Marano; G. Sottile

The Extended Analogue Silicon Photo-multiplier Integrated Read Out Chip, EASIROC, is a chip proposed as front-end of the camera at the focal plane of the imaging Cherenkov ASTRI SST-2M telescope prototype. This paper presents the results of the measurements performed to characterize EASIROC in order to evaluate its compliance with the ASTRI SST-2M focal plane requirements. In particular, we investigated the trigger time walk and the jitter effects as a function of the pulse amplitude. The EASIROC output signal is found to vary linearly as a function of the input pulse amplitude with very low level of electronic noise and cross-talk (<1%). Our results show that it is suitable as front-end chip for the camera prototype, although, specific modifications are necessary to adopt the device in the final version of the telescope.


Proceedings of SPIE | 2014

The camera of the ASTRI SST-2M prototype for the Cherenkov Telescope Array

O. Catalano; Maria Concetta Maccarone; C. Gargano; Giovanni La Rosa; A. Segreto; G. Sottile; Vincenzo De Caprio; F. Russo; Milvia Capalbi; Pierluca Sangiorgi; G. Bonanno; A. Grillo; S. Garozzo; D. Marano; S. Billotta; G. Romeo; L. Stringhetti; M. Fiorini; Nicola La Palombara; S. Incorvaia; Giorgio Toso; D. Impiombato; Salvatore Giarrusso

In the context of the Cherenkov Telescope Array observatory project, the ASTRI SST-2M end-to-end prototype telescope, entirely supported by the Italian National Institute of Astrophysics, is designed to detect cosmic primary gamma ray energies from few TeV up to hundreds of TeV. The ASTRI SST-2M prototype camera is part of the challenging synergy of novel optical design, camera sensors, front-end electronics and telescope structure design. The camera is devoted to imaging and recording the Cherenkov images of air showers induced by primary particles into the Earth’s atmosphere. In order to match the energy range mentioned above, the camera must be able to trigger events within a few tens of nanoseconds with high detection efficiency. This is obtained by combining silicon photo-multiplier sensors and suitable front-end electronics. Due to the characteristic imprint of the Cherenkov image that is a function of the shower core distance, the signal dynamic range of the pixels and consequently of the front-end electronics must span three orders of magnitude (1:1000 photo-electrons). These and many other features of the ASTRI SST-2M prototype camera will be reported in this contribution together with a complete overview of the mechanical and thermodynamic camera system.


arXiv: Instrumentation and Detectors | 2013

Characterization of the front-end EASIROC for read-out of SiPM in the ASTRI camera

D. Impiombato; Salvatore Giarrusso; S. Billotta; G. Bonanno; O. Catalano; A. Grillo; G. La Rosa; D. Marano; T. Mineo; F. Russo; G. Sottile

Abstract The design and realization of a prototype for the Small-Size class Telescopes of the Cherenkov Telescope Array is one of the cornerstones of the ASTRI project. The prototype will adopt a focal plane camera based on Silicon Photo-Multiplier sensors that coupled with a dual mirror optics configuration represents an innovative solution for the detection of Atmospheric Cherenkov light. These detectors can be read by the Extended Analogue Silicon Photo-Multiplier Integrated Read Out Chip (EASIROC) equipped with 32-channels. In this paper, we report some preliminary results on measurements aimed to evaluate EASIROC capability of autotriggering and measurements of the trigger time walk, jitter, DAC linearity and trigger efficiency vs the injected charge. Moreover, the dynamic range of the ASIC is also reported.


Journal of Instrumentation | 2014

Evaluation of the optical cross talk level in the SiPMs adopted in ASTRI SST-2M Cherenkov Camera using EASIROC front-end electronics

D. Impiombato; Salvatore Giarrusso; T. Mineo; G. Agnetta; B. Biondo; O. Catalano; C. Gargano; G. La Rosa; F. Russo; G. Sottile; S. Billotta; G. Bonanno; S. Garozzo; D. Marano; G. Romeo

ASTRI (Astrofisica con Specchi a Tecnologia Replicante Italiana), is a flagship project of the Italian Ministry of Education, University and Research whose main goal is the design and construction of an end-to-end prototype of the Small Size of Telescopes of the Cherenkov Telescope Array. The prototype, named ASTRI SST-2M, will adopt a wide field dual mirror optical system in a Schwarzschild-Couder configuration to explore the VHE range of the electromagnetic spectrum. The camera at the focal plane is based on Silicon Photo-Multipliers detectors which is an innovative solution for the detection astronomical Cherenkov light. This contribution reports some preliminary results on the evaluation of the optical cross talk level among the SiPM pixels foreseen for the ASTRI SST-2M camera.


Ground-based and Airborne Instrumentation for Astronomy VII | 2018

The ASTRI camera for the Cherenkov Telescope Array

O. Catalano; Milvia Capalbi; C. Gargano; S. Giarrusso; D. Impiombato; Giovanni La Rosa; Maria Concetta Maccarone; Teresa Mineo; F. Russo; Pierluca Sangiorgi; A. Segreto; G. Sottile; B. Biondo; G. Bonanno; S. Garozzo; A. Grillo; D. Marano; G. Romeo; Salvatore Scuderi; R. Canestrari; Paolo Conconi; E. Giro; Giovanni Pareschi; Giorgia Sironi; V. Conforti; F. Gianotti; Renato Gimenes

The Cherenkov Telescope Array (CTA) foresees, in its southern site (Chile), the implementation of up to 70 small-sized telescopes (SSTs), which will extend the energy coverage up to hundreds of TeV. It has been proposed that one of the first set of CTA SSTs will be represented by the ASTRI mini-array, which includes (at least) nine ASTRI telescopes. The endto-end prototype of such telescopes, named the ASTRI SST-2M, is installed in Italy and it is now completing the overall commissioning and entering the science verification phase. ASTRI telescopes are characterized by an optical system based on a dual-mirror Schwarzschild-Couder design and a camera at the focal plane composed of silicon photomultiplier sensors managed by a fast read-out electronics specifically designed. Based on a custom peak-detector mode, the ASTRI camera electronics is designed to perform Cherenkov signal detection, trigger generation, digital conversion of the signals and data transmission to the camera server. In this contribution we will describe the main features of the ASTRI camera, its performance and results obtained during the commissioning phase of the ASTRI SST-2M prototype in view of the ASTRI mini-array implementation.


International Journal of Modelling and Simulation | 2014

PSPICE High-Level Model and Simulations of the EASIROC Analog Front-End

D. Marano; G. Bonanno; S. Billotta; A. Grillo; S. Garozzo; G. Romeo; O. Catalano; Giovanni La Rosa; G. Sottile; D. Impiombato

Abstract The present paper is intended to implement and simulate the Extended Analogue Silicon-photomultiplier Integrated Read-Out Chip (EASIROC) fully analogue front-end model, in order to investigate its foremost characteristics and demonstrate its practical effectiveness when its analogue inputs are driven by the silicon photomultiplier (SiPM) signals. The circuit models of all functional blocks are described. Frequency and dynamic features of all circuit front-end sections are briefly addressed, and design mathematical equations are derived as well. PSPICE simulations of each single model are carried out to analyse and confirm its analogue behaviour.


Experimental Astronomy | 2017

Procedures for the relative calibration of the SiPM gain on ASTRI SST-2M camera

D. Impiombato; O. Catalano; S. Giarrusso; T. Mineo; G. La Rosa; C. Gargano; Pierluca Sangiorgi; A. Segreto; G. Sottile; G. Bonanno; S. Garozzo; A. Grillo; D. Marano; G. Romeo; R. Gimenes

ASTRI SST-2M is one of the prototypes of the small size class of telescopes proposed for the Cherenkov Telescope Array. Its optical design is based on a dual-mirror Schwarzschild-Couder configuration, and the camera is composed by a matrix of monolithic multipixel silicon photomultipliers managed by ad-hoc tailored front-end electronics. This paper describes the procedures for the gain calibration on the ASTRI SST-2M. Since the SiPM gain depends on the operative voltage and the temperature, we adjust the operative voltages for all sensors to have equal gains at a reference temperature. We then correct gain variations caused by temperature changes by adjusting the operating voltage of each sensor. For that purpose the SiPM gain dependence on operating voltage and on temperature have been measured. In addition, we present the calibration procedures and the results of the experimental measurements to evaluate, for each pixel, the parameters necessary to make the trigger uniform over the whole focal plane.

Collaboration


Dive into the D. Impiombato's collaboration.

Researchain Logo
Decentralizing Knowledge