D J Beard
University of Oxford
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by D J Beard.
Journal of Bone and Joint Surgery-british Volume | 2007
David W. Murray; Ray Fitzpatrick; Katherine Rogers; Hemant Pandit; D J Beard; A J Carr; Jill Dawson
The Oxford hip and knee scores have been extensively used since they were first described in 1996 and 1998. During this time, they have been modified and used for many different purposes. This paper describes how they should be used and seeks to clarify areas of confusion.
Journal of Bone and Joint Surgery-british Volume | 2009
George Grammatopoulos; Hemant Pandit; Young-Min Kwon; R Gundle; P. McLardy-Smith; D J Beard; David W. Murray; Harinderjit Gill
Inflammatory pseudotumours occasionally occur after metal-on-metal hip resurfacing and often lead to revision. Our aim was to determine the severity of this complication by assessing the outcome of revision in these circumstances and by comparing this with the outcome of other metal-on-metal hip resurfacing revisions as well as that of matched primary total hip replacements. We identified 53 hips which had undergone metal-on-metal hip resurfacing and required revision at a mean of 1.59 years (0.01 to 6.69) after operation. Of these, 16 were revised for pseudotumours, 21 for fracture and 16 for other reasons. These were matched by age, gender and diagnosis with 103 patients undergoing primary total hip replacement with the Exeter implant. At a mean follow-up of three years (0.8 to 7.2) the outcome of metal-on-metal hip resurfacing revision for pseudotumour was poor with a mean Oxford hip score of 20.9 (sd 9.3) and was significantly worse (p < 0.001) than the outcome for fracture with a mean Oxford hip score of 40.2 (sd 9.2) or that for other causes with a mean Oxford hip score of 37.8 (sd 9.4). The clinical outcome of revision for pseudotumour was also significantly worse (p < 0.001) than the outcome of matched primary total hip replacements. By contrast, the outcome for fracture and other causes was not significantly different from that of matched primary total hip replacements (p = 0.065). After revision for pseudotumour there were three cases of recurrent dislocation, three of palsy of the femoral nerve, one of stenosis of the femoral artery and two of loosening of the component. Five hips required further revision. In three of these there was evidence of recurrent pseudotumour, and one is currently awaiting further revision. The incidence of major complications after revision for pseudotumour (50%) was significantly higher (p = 0.018) than that after revision for other causes (14%). The outcome of revision for pseudotumour is poor and consideration should be given to early revision to limit the extent of the soft-tissue destruction. The outcome of resurfacing revision for other causes is good.
Journal of Orthopaedic Research | 2009
Young-Min Kwon; Peter Thomas; Burkhard Summer; Hemant Pandit; Adrian Taylor; D J Beard; David W. Murray; Harinderjit Gill
Locally destructive soft tissue pseudotumor has been reported in patients following metal‐on‐metal hip resurfacing arthroplasty (MoMHRA). A delayed hypersensitivity reaction type IV to nickel (Ni), chromium (Cr), or cobalt (Co) has been suggested to play a role in its aetiology. The aim of this study was to investigate the incidence and level of metal‐induced systemic hypersensitivity in patients with MoMHRA, both with and without pseudotumor by measuring lymphocyte proliferation responses to metals. A total of 92 patients were investigated: (1) MoMHRA patients with pseudotumors (nine female, one male); (2) MoMHRA patients without pseudotumors (30 female, 30 male); and (3) age‐matched control subjects without metal implants (9 female, 13 male). The venous blood samples were collected for serum Ni, Co, and Cr ion level measurements and lymphocyte transformation tests (LTT). A higher incidence and level of enhanced lymphocyte reactivity only to Ni was found in patients with MoMHRA compared to the patients without MoM implants, reflecting exposure and immune reactivity. However, lymphocyte reactivity to Co, Cr, and Ni did not significantly differ in patients with pseudotumors compared to those patients without pseudotumors. This suggests that systemic hypersensitivity type IV reactions, as measured by lymphocyte proliferation response to these metals, may not be the dominant biological reaction involved in the occurrence of the soft tissue pseudotumors.
Journal of Bone and Joint Surgery-british Volume | 2010
David Culliford; J Maskell; D J Beard; D W Murray; A J Price; N K Arden
Using the General Practice Research Database, we examined the temporal changes in the rates of primary total hip (THR) and total knee (TKR) replacement, the age at operation and the female-to-male ratio between 1991 and 2006 in the United Kingdom. We identified 27 113 patients with THR and 23 843 with TKR. The rate of performance of THR and TKR had increased significantly (p < 0.0001 for both) during the 16-year period and was greater for TKR, especially in the last five years. The mean age at operation was greater for women than for men and had remained stable throughout the period of study. The female-to-male ratio was higher for THR and TKR and had remained stable. The data support the notion that the rate of joint replacement is increasing in the United Kingdom with the rate of TKR rising at the highest rate. The perception that the mean age for TKR has decreased over time is not supported.
Journal of Bone and Joint Surgery-british Volume | 2008
J G Andrew; Jeya Palan; H V Kurup; P. H. Gibson; David W. Murray; D J Beard
A prospective, multi-centre study was carried out on 1421 total hip replacements between January 1999 and July 2007 to examine if obesity has an effect on clinical outcomes. The patients were categorised into three groups: non-obese (body mass index (BMI) < 30 kg/m(2)), obese (BMI 30 to 40 kg/m(2)) and morbidly obese (BMI > 40 kg/m(2)). The primary outcome measure was the change in Oxford hip score at five years. Secondary outcome measures included dislocation and revision rates, increased haemorrhage, deep infection, deep-vein thrombosis and pulmonary embolism, mean operating time and length of hospital stay. Radiological analysis assessing heterotopic ossification, femoral osteolysis and femoral stem positioning was performed. Data were incomplete for 362 hips (25.5%) There was no difference in the change in the Oxford hip score, complication rates or radiological changes at five years between the groups. The morbidly obese group was significantly younger and required a significantly longer operating time. Obese and morbidly obese patients have as much to gain from total hip replacement as non-obese patients.
Journal of Bone and Joint Surgery-british Volume | 2003
A J Price; Jonathan Rees; D J Beard; E. Juszczak; S. R. Carter; S. H. White; R. de Steiger; C. A. F. Dodd; M Gibbons; P. McLardy-Smith; J. W. Goodfellow; D W Murray
Before proceeding to longer-term studies, we have studied the early clinical results of a new mobile-bearing total knee prosthesis in comparison with an established fixed-bearing device. Patients requiring bilateral knee replacement consented to have their operations under one anaesthetic using one of each prosthesis. They also agreed to accept the random choice of knee (right or left) and to remain ignorant as to which side had which implant. Outcomes were measured using the American Knee Society Score (AKSS), the Oxford Knee Score (OKS), and determination of the range of movement and pain scores before and at one year after operation. Preoperatively, there was no systematic difference between the right and left knees. One patient died in the perioperative period and one mobile-bearing prosthesis required early revision for dislocation of the meniscal component. At one year the mean AKSS, OKS and pain scores for the new device were slightly better (p < 0.025) than those for the fixed-bearing device. There was no difference in the range of movement. We believe that this is the first controlled, blinded trial to compare early function of a new knee prosthesis with that of a standard implant. It demonstrates a small but significant clinical advantage for the mobile-bearing design.
Journal of Bone and Joint Surgery-british Volume | 2007
D J Beard; Hemant Pandit; Harinderjit Gill; D Hollinghurst; C. A. F. Dodd; David W. Murray
Patellofemoral joint degeneration is often considered a contraindication to medial unicompartmental knee replacement. We examined the validity of this preconception using information gathered prospectively on the intra-operative status of the patellofemoral joint in 824 knees in 793 consecutive patients who underwent Oxford unicondylar knee replacement for anteromedial osteoarthritis. All operations were performed between January 1998 and September 2005. A five-point grading system classified degeneration of the patellofemoral joint from none to full-thickness cartilage loss. A subclassification of the presence or absence of any full-thickness cartilage loss was subsequently performed to test selected hypotheses. Outcome was evaluated independently by physiotherapists using the Oxford and the American Knee Society Scores with a minimum follow-up of one year. Full-thickness cartilage loss on the trochlear surface was observed in 100 of 785 knees (13%), on the medial facet of the patella in 69 of 782 knees (9%) and on the lateral facet in 29 of 784 knees (4%). Full-thickness cartilage loss at any location was seen in 128 knees (16%) and did not produce a significantly worse outcome than those with a normal or near-normal joint surface. The severity of the degeneration at any of the intra-articular locations also had no influence on outcome. We concluded that, provided there is not bone loss and grooving of the lateral facet, damage to the articular cartilage of the patellofemoral joint to the extent of full-thickness cartilage loss is not a contraindication to the Oxford mobile-bearing unicompartmental knee replacement.
Journal of Bone and Joint Surgery-british Volume | 2007
D J Beard; Hemant Pandit; Simon Ostlere; C. Jenkins; C. A. F. Dodd; David W. Murray
Anterior knee pain and/or radiological evidence of degeneration of the patellofemoral joint are considered to be contraindications to unicompartmental knee replacement. The aim of this study was to determine whether this is the case. Between January 2000 and September 2003, in 100 knees (91 patients) in which Oxford unicompartmental knee replacements were undertaken for anteromedial osteoarthritis, pre-operative anterior knee pain and the radiological status of the patellofemoral joint were defined using the Altman and Ahlback systems. Outcome was evaluated at two years with the Oxford knee score and the American Knee Society score. Pre-operatively 54 knees (54%) had anterior knee pain. The clinical outcome was independent of the presence or absence of pre-operative anterior knee pain. Degenerative changes of the patellofemoral joint were seen in 54 patients (54%) on the skyline radiographs, including ten knees (10%) with joint space obliteration. Patients with medial patellofemoral degeneration had a similar outcome to those without. For some outcome measures patients with lateral patellofemoral degeneration had a worse score than those without, but these patients still had a good outcome, with a mean Oxford knee score of 37.6 (SD 9.5). These results show that neither anterior knee pain nor radiologically-demonstrated medial patellofemoral joint degeneration should be considered a contraindication to Oxford unicompartmental knee replacement. With lateral patellofemoral degeneration the situation is less well defined and caution should be observed.
Biomedical Materials | 2009
Young-Min Kwon; Zhidao Xia; Sion Glyn-Jones; D J Beard; Harinderjit Gill; David W. Murray
Despite the satisfactory short-term implant survivorship of metal-on-metal hip resurfacing arthroplasty, periprosthetic soft-tissue masses such as pseudotumours are being increasingly reported. Cytotoxic effects of cobalt or chromium have been suggested to play a role in its aetiology. The aim of this study was to investigate the effects of clinically relevant metal nanoparticles and ions on the viability of macrophages in vitro. A RAW 264.7 murine macrophage cell line was cultured in the presence of either: (1) cobalt, chromium and titanium nanoparticles sized 30-35 nm; or (2) cobalt sulphate and chromium chloride. Two methods were used to quantify cell viability: Alamar Blue assay and Live/Dead assay. The cytotoxicity was observed only with cobalt. Cobalt nanoparticles and ions demonstrated dose-dependent cytotoxic effects on macrophages in vitro: the cytotoxic concentrations of nanoparticles and ions were 1 x 10(12) particles ml(-1) and 1000 microM, respectively. The high concentration of cobalt nanoparticles required for cytotoxicity of macrophages in vitro suggests that increased production of cobalt nanoparticles in vivo, due to excessive MoM implant wear, may lead to local adverse biological effects. Therefore, cytotoxicity of high concentrations of metal nanoparticles phagocytosed by macrophages located in the periprosthetic tissues may be an important factor in pathogenesis of pseudotumours.
BMJ | 2014
K Wartolowska; Andrew Judge; Sally Hopewell; Gary S. Collins; Dean Bjf.; Ines Rombach; David Brindley; Julian Savulescu; D J Beard; A J Carr
Objective To investigate whether placebo controls should be used in the evaluation of surgical interventions. Design Systematic review. Data sources We searched Medline, Embase, and the Cochrane Controlled Trials Register from their inception to November 2013. Study selection Randomised clinical trials comparing any surgical intervention with placebo. Surgery was defined as any procedure that both changes the anatomy and requires a skin incision or use of endoscopic techniques. Data extraction Three reviewers (KW, BJFD, IR) independently identified the relevant trials and extracted data on study details, outcomes, and harms from included studies. Results In 39 out of 53 (74%) trials there was improvement in the placebo arm and in 27 (51%) trials the effect of placebo did not differ from that of surgery. In 26 (49%) trials, surgery was superior to placebo but the magnitude of the effect of the surgical intervention over that of the placebo was generally small. Serious adverse events were reported in the placebo arm in 18 trials (34%) and in the surgical arm in 22 trials (41.5%); in four trials authors did not specify in which arm the events occurred. However, in many studies adverse events were unrelated to the intervention or associated with the severity of the condition. The existing placebo controlled trials investigated only less invasive procedures that did not involve laparotomy, thoracotomy, craniotomy, or extensive tissue dissection. Conclusions Placebo controlled trial is a powerful, feasible way of showing the efficacy of surgical procedures. The risks of adverse effects associated with the placebo are small. In half of the studies, the results provide evidence against continued use of the investigated surgical procedures. Without well designed placebo controlled trials of surgery, ineffective treatment may continue unchallenged.