Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where D.M. Groschen is active.

Publication


Featured researches published by D.M. Groschen.


American Journal of Veterinary Research | 2013

Effect of water depth on amount of flexion and extension of joints of the distal aspects of the limbs in healthy horses walking on an underwater treadmill

Jose L. Mendez-Angulo; Anna M. Firshman; D.M. Groschen; Philip J. Kieffer; Troy N. Trumble

OBJECTIVE To determine the maximum amount of flexion and extension of the carpal, tarsal, metacarpophalangeal, and metatarsophalangeal joints and the percentage duration of the stance and swing phases of the stride for horses walking on an underwater treadmill in various water depths. ANIMALS 9 healthy adult horses. PROCEDURES Zinc oxide markers were placed on the forelimbs and hind limbs of the horses. Video was recorded of horses walking (0.9 m/s) on an underwater treadmill during baseline conditions (< 1 cm of water) or in various amounts of water (level of the metatarsophalangeal, tarsal, and stifle joints). Maximum amount of joint flexion and extension, range of motion (ROM), and the percentage durations of the stance and swing phases of the stride were determined with 2-D motion analysis software. RESULTS The ROM was greater for all evaluated joints in any amount of water versus ROM for joints in baseline conditions (primarily because of increases in amount of joint flexion). The greatest ROM for carpal joints was detected in a tarsal joint water depth, for tarsal joints in a stifle joint water depth, and for metacarpophalangeal and metatarsophalangeal joints in metatarsophalangeal and tarsal joint water depths. As water depth increased, the percentage durations of the stance and swing phases of the stride significantly decreased and increased, respectively. CONCLUSIONS AND CLINICAL RELEVANCE Results of this study suggested that exercise on an underwater treadmill is useful for increasing the ROM of various joints of horses during rehabilitation and that the depth of water affects the amount of flexion and extension of joints.


Veterinary Journal | 2014

Impact of walking surface on the range of motion of equine distal limb joints for rehabilitation purposes

Jose L. Mendez-Angulo; Anna M. Firshman; D.M. Groschen; Philip J. Kieffer; Troy N. Trumble

The aim of this study was to evaluate the effect of three footing surfaces on the flexion/extension, and range of motion (ROM) of the carpus, tarsus and fetlocks in the horse. The percentage of stride spent in the stance phase of sound horses at the walk was also measured. Nine sound horses were walked on hard ground (HD), soft ground (SF) and a land treadmill (LT), and five complete gait cycles were recorded by a digital video camera. Retro-reflective markers were placed on the skin at four anatomical locations on the left fore and hind limbs, and data were analyzed using two-dimensional (2D) motion-analysis software. Maximal flexion/extension angles and range of motion were calculated for each joint, and the percentage of the stride spent in stance phase was determined for each stride. Maximal flexion of the tarsus and hind fetlock was greater on LT and SF compared to HD, while maximal flexion of the carpus was greater on LT compared to HD and SF. Maximal extension of the carpus was greater on HD compared to SF and LT, maximal extension of the tarsus was greater on HD and SF compared to LT, and maximal extension of the forelimb and hind limb fetlocks was greater on LT compared to HD and SF. The greatest overall ROM of the carpus and fetlocks was achieved on LT, while the greatest overall ROM of the tarsus was achieved on SF. The stance percentage of the stride for the hind limb was significantly different between all surfaces. In conclusion, walking surface influences flexion/extension of the carpus, tarsus and fetlocks in healthy horses, which should be considered when walking equine rehabilitation cases.


American Journal of Veterinary Research | 2016

Biochemical, histologic, and biomechanical characterization of native and decellularized flexor tendon specimens harvested from the pelvic limbs of orthopedically normal dogs

Daniel G. Balogh; Jeffery J. Biskup; M. Gerard O'Sullivan; Ruth M. Scott; D.M. Groschen; Richard B. Evans; Michael G. Conzemius

OBJECTIVE To evaluate the biochemical and biomechanical properties of native and decellularized superficial digital flexor tendons (SDFTs) and deep digital flexor tendons (DDFTs) harvested from the pelvic limbs of orthopedically normal dogs. SAMPLE 22 commercially supplied tendon specimens (10 SDFT and 12 DDFT) harvested from the pelvic limbs of 13 canine cadavers. PROCEDURES DNA, glycosaminoglycan, collagen, and protein content were measured to biochemically compare native and decellularized SDFT and DDFT specimens. Mechanical testing was performed on 4 groups consisting of native tendons (5 SDFTs and 6 DDFTs) and decellularized tendons (5 SDFTs and 6 DDFTs). All tendons were preconditioned, and tension was applied to failure at 0.5 mm/s. Failure mode was video recorded for each tendon. Load-deformation and stress-strain curves were generated; calculations were performed to determine the Young modulus and stiffness. Biochemical and biomechanical data were statistically compared by use of the Wilcoxon rank sum test. RESULTS Decellularized SDFT and DDFT specimens had significantly less DNA content than did native tendons. No significant differences were identified between native and decellularized specimens with respect to glycosaminoglycan, collagen, or protein content. Biomechanical comparison yielded no significant intra- or intergroup differences. All DDFT constructs failed at the tendon-clamp interface, whereas nearly half (4/10) of the SDFT constructs failed at midsubstance. CONCLUSIONS AND CLINICAL RELEVANCE Decellularized commercial canine SDFT and DDFT specimens had similar biomechanical properties, compared with each other and with native tendons. The decellularization process significantly decreased DNA content while minimizing loss of extracellular matrix components. Decellularized canine flexor tendons may provide suitable, biocompatible graft scaffolds for bioengineering applications such as tendon or ligament repair.


Veterinary Journal | 2015

Circumferential hoof clamp method of lameness induction in the horse

M.E. Swaab; Jose L. Mendez-Angulo; D.M. Groschen; Nicolas S. Ernst; Murray P. Brown; Troy N. Trumble

A circumferential hoof clamp method to induce controlled and reversible lameness in the forelimbs of eight horses was assessed. Peak vertical forces and vertical impulses were recorded using a force plate to verify induced lameness. Video recordings were used by blinded observers to determine subjective lameness using a 0-5 scale and any residual lameness following clamp loosening. Tightening of clamps resulted in consistent, visible lameness in the selected limbs in all horses. Lameness was confirmed by significant decreases from baseline in the peak vertical force (P <0.01). Lameness was also confirmed subjectively by elevated median scores (0 at baseline and 2 during lameness). Lameness was not immediately reversible after clamp loosening (median score 1.5), but horses were not obviously lame after clamp removal and were no different from initial baseline (median score 0.5) approximately 3 days later.


Osteoarthritis and Cartilage | 2013

Non-terminal animal model of post-traumatic osteoarthritis induced by acute joint injury

M. Boyce; Troy N. Trumble; Cathy S. Carlson; D.M. Groschen; K.A. Merritt; Murray P. Brown


Osteoarthritis and Cartilage | 2012

New urine biomarker assay compares to synovial fluid changes after acute joint injury in an equine model of osteoarthritis

Troy N. Trumble; D.M. Groschen; N. Ha; M. Boyce; K.A. Merritt; Murray P. Brown


Veterinary and Comparative Orthopaedics and Traumatology | 2018

Synovial Fluid Cytokine Concentrations Are Influenced by Disease Etiology

Michael G. Conzemius; Ruth M. Scott; D.M. Groschen; Richard B. Evans


Osteoarthritis and Cartilage | 2015

Concentrations of cytokines, matrix metalloproteinases, and tissue inhibitors of matrix metalloproteinases in autologous conditioned serum from horses with distal interphalangeal joint osteoarthritis

D.M. Tatarniuk; D.M. Groschen; K.A. Merritt; M.C. Maher; Nicolas S. Ernst; Murray P. Brown; Troy N. Trumble


Osteoarthritis and Cartilage | 2014

Matrix metalloproteinase and tissue inhibitor of metalloproteinase activity in synovial fluid from horses with post-traumatic osteoarthritis

Troy N. Trumble; D.M. Groschen; K.A. Merritt; Murray P. Brown


Osteoarthritis and Cartilage | 2012

Comparison of range of motion of the distal limb joints of healthy horses when walking on three conventional surfaces

Jose L. Mendez-Angulo; Anna M. Firshman; D.M. Groschen; Philip J. Kieffer; Troy N. Trumble

Collaboration


Dive into the D.M. Groschen's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

M. Boyce

University of Minnesota

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge