Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Daigo Sakagoshi is active.

Publication


Featured researches published by Daigo Sakagoshi.


Muscle & Nerve | 2010

Polyneuropathy caused by cobalt–chromium metallosis after total hip replacement

Tokuhei Ikeda; Kazuya Takahashi; Tamon Kabata; Daigo Sakagoshi; Katsuro Tomita; Masahito Yamada

Although metal intoxication after arthroplasty causes various symptoms, polyneuropathy has never been the focus of clinical investigation. We report the case of a 56‐year‐old woman with metal neuropathy. She had metallosis after hip arthroplasty with a cobalt–chromium alloy prosthesis. She developed progressive sensory disturbance, hearing loss, and hypothyroidism. Sural nerve biopsy indicated axonopathy. After exchange arthroplasty, blood levels of cobalt and chromium decreased, and her symptoms improved. Cobalt or chromium can cause axonopathy. Muscle Nerve, 2010


Journal of Arthroplasty | 2010

A Mechanical Analysis of Femoral Resurfacing Implantation for Osteonecrosis of the Femoral Head

Daigo Sakagoshi; Tamon Kabata; Yuichiro Umemoto; Jiro Sakamoto; Katsuro Tomita

Hip resurfacing is becoming a popular procedure for treating osteonecrosis of the femoral head. However, the biomechanical changes that occur after femoral resurfacing have not been fully investigated with respect to the individual extent of the necrosis. In this study, we evaluated biomechanical changes at various extents of necrosis and implant alignments using the finite element analysis method. We established 3 patterns of necrosis by depth from the surface of femoral head and 5 stem angles. For these models, we evaluated biomechanical changes associated with the extent of necrosis and the stem alignment. Our results indicate that stress distribution near the bone-cement interface increased with expansion of the necrosis. The maximum stress on the prosthesis was decreased with stem angles ranging from 130° to 140°. The peak stress of cement increased as the stem angle became varus. This study indicates that resurfacing arthroplasty will have adverse biomechanical effects when there is a large extent of osteonecrosis and excessive varus or valgus implantation of the prosthesis.


The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME | 2012

7A11 A Study on Mechanical Influence of Contact between Hip Stem and Cement in the Cemented Total Hip Arthroplasty

Yu Liu; Jiro Sakamoto; Takeshi Sawaguchi; Daigo Sakagoshi


Muscle & Nerve | 2011

Reply: Letters to the Editor

Tokuhei Ikeda; Kazuya Takahashi; Tamon Kabata; Daigo Sakagoshi; Katsuro Tomita; Masahito Yamada


The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME | 2010

0938 A study on mechanical evaluation of femoral resurfacing hip implant

Jiro Sakamoto; Masahiro Okuda; Daigo Sakagoshi; Tamon Kahata; Katsuro Tomita


The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME | 2009

123 A Finite-Element Analysis of Femoral Resurfacing Implantation Considering Contact Condition

Masahiro Okuda; Jiro Sakamoto; Yuichiro Umemoto; Tamon Kabata; Daigo Sakagoshi; Katsuro Tomita


The proceedings of the JSME annual meeting | 2007

0908 Mechanical Consideration on Design of Femoral Resurfacing Implant

Masahiro Okuda; Jiro Sakamoto; Yuichiro Umemoto; Daigo Sakagoshi; Tamon Kabata; Juhachi Oda; Katsuro Tomita


The Proceedings of The Computational Mechanics Conference | 2007

2213 A Mechanical Analysis of Femoral Resurfacing Implant Considering Osteonecrosis of Femoral Head

Masahiro Okuda; Jiro Sakamoto; Yuichiro Umemoto; Tamon Kabata; Daigo Sakagoshi; Juhachi Oda; Katsuro Tomita


The Proceedings of Conference of Hokuriku-Shinetsu Branch | 2007

914 A Mechanical Analysis of Femoral Resurfacing Implantation for Osteonecrosis of Femoral Head

Yuichiro Umemoto; Jiro Sakamoto; Tamon Kabata; Daigo Sakagoshi; Hideo Takata; Juhachi Oda; Katsuro Tomita


The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME | 2006

405 A Study on Mechanical Evaluation of Femoral Resurfacing Implantation by Using Finite Element Method

Yuichiro Umemoto; Yoshimi Omura; Jiro Sakamoto; Daigo Sakagoshi; Tamon Tabata; Hideo Takata; Juhachi Oda; Katsuro Tomita

Collaboration


Dive into the Daigo Sakagoshi's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge