Featured researches published by Dan Manor.


Journal of Ultrasound in Medicine | 2002

A New Angle-Independent Doppler Ultrasonic Device for Assessment of Blood Flow Volume in the Extracranial Internal Carotid Artery

Jean F. Soustiel; Eli Levy; Menashe Zaaroor; Roni Bibi; Sergei Lukaschuk; Dan Manor

Objective. To evaluate a new angle‐independent ultrasonic device for assessment of blood flow volume in the internal carotid artery. Methods. In vitro, a pulsatile pump was set to provide an outflow of physiological fluid at 500 mL/min through an 8‐mm‐diameter tube. Flow volume rates were measured 10 times by 10 different operators and compared with time‐collected flow volume rates. In vivo, internal and common carotid artery blood flow volumes were measured in 28 volunteers by 2 operators using a FlowGuard device (Biosonix Ltd). Internal and common carotid artery diameters and blood flow volumes were also assessed by Duplex sonography and compared with FlowGuard measurements. In 10 volunteers, internal carotid artery blood flow volume changes in response to monitored breath manipulations were recorded. Results. In vitro, intraoperator variability was 4.04% (range, 2%–5.7%). The mean error rate ± SD was 3.54% ± 0.8% (range, 2.7%–5.2%). In vivo, the mean common carotid artery blood flow volume was 456 ± 39 mL/min (range, 417–583 mL/min) with a mean diameter of 6.7 ± 0.7 mm (range, 5.8–8.7 mm). The mean internal carotid artery blood flow volume was 277 ± 25 mL/min (range, 239–338 mL/min) with a mean diameter of 5 ± 0.5 mm (range, 4.1–6.1 mm). No significant difference was found between operators. Internal carotid artery diameter and blood flow volume measured by the FlowGuard were closely correlated with the results of Duplex sonography. Repeated shifts of end‐tidal CO2 induced reproducible changes in internal carotid artery flow volume: 187.5 ± 18.1 mL/min at 26.8 ± 1.9 mm Hg and 382.1 ± 18.2 mL/min at 47 ± 2.2 mm Hg. Conclusions. The FlowGuard showed that volume flow studies in the internal carotid artery could be easily performed, with results compatible with those of previous clinical reports. Duplex comparative results and breath‐induced changes in internal carotid artery flow volume justify further evaluation of the system.


Stroke | 2001

Hemodynamic Consequences of Cerebral Vasospasm on Perforating Arteries A Phantom Model Study

Jean F. Soustiel; Eli Levy; Roni Bibi; Sergei Lukaschuk; Dan Manor

Background and Purpose— Hemodynamics of cerebral vasospasm after subarachnoid hemorrhage remain unclear, and the discrepancy between ultrasonographic or angiographic evidence of arterial narrowing and neurological ischemic deficit is still debated. Most blood flow studies have been involved with large arteries, and thus, very little is known regarding the hemodynamic behavior of small perforating vessels. Patients with symptomatic vasospasm, however, often present with neurological signs suggesting involvement of deep-sited areas of the brain supplied by perforating arteries. Methods— A pulsatile pump was set to provide an outflow of 350 mL/min through a 10-mm-diameter C-flex tube at a perfusion pressure of 130/80 mm Hg. The perfusion fluid used was prepared to approximate blood viscosity. Perforating arteries were simulated by a 1-mm tube connected to the parent tube at a 90° angle. Cylindrical stenotic devices of decreasing diameters were then introduced into the parent tube at the level of the aperture of the secondary tube and 1.5 diameters upstream of it. Velocity profiles both proximal and distal to the stenosis in the parent tube were obtained with a newly developed ultrasonographic flowmeter that allows for high spatial resolution. Results— Increasing stenosis resulted in decreased outflow in the main tube, although it was significant only with severe stenosis. Whenever the simulated stenosis was placed upstream of the secondary tube, flow reduction was associated with a progressive change in the velocity profile, which gradually changed from laminar conditions to a jet stream limited to the center of the lumen. Further diameter reduction was responsible for the occurrence of flow separation with retrograde flow velocities in the periphery of the lumen. In the secondary tube, flow reduction was much more pronounced and began at a lesser degree of stenosis. Increasing fluid viscosity and decreasing perfusion pressure enhanced flow separation and prominently affected the outflow in the secondary tube. Conversely, whenever the simulated stenosis involved the branching area of the secondary tube, there was a slightly progressive decrease in the relative flow in the main tube as the stenosis became tighter. When the stenosis equaled the diameter of the secondary tube, the relative contribution of the secondary tube increased markedly at the expense of the main tube outflow. Conclusions— The present results show that local cerebral vasospasm induces changes in postvasospastic velocity profile affecting the shear rate and may eventually lead to flow separation. This phenomenon may, in turn, result in a venturi-like effect over the aperture of perforating arteries branching out of the postvasospastic portion of the affected parent artery. These alterations of cerebral hemodynamics may account for at least part of the vasospasm symptomatology, especially in the vertebrobasilar system, where vasospasm is commonly focal rather than diffuse. Furthermore, these changes proved to be affected significantly by manipulations of pressure and viscosity, supporting the use of hyperdynamic therapy in the management of cerebral vasospasm.


Archive | 2001

Medical device for applying cyclic therapeutic action to a subject's foot

Dan Manor; Roni Bibi; Eli Levy; Ascher Shmulewitz


Archive | 2000

Medical apparatus for facilitating blood circulation in the lower limbs

Dan Manor; Roni Bibi; Eli Levi


Journal of the Acoustical Society of America | 2003

Dual ultrasonic transducer probe for blood flow measurement, and blood vessel diameter determination method

Dan Manor; Eli Levy; Roni Bibi; Sergei Lukaschuk


Journal of the Acoustical Society of America | 2004

Ultrasonic transducer probe and a measurement device utilizing the same

Dan Manor; Eli Levy; Roni Bibi; Sergei Lukaschuk


Archive | 1999

Medical device for applying a cyclic therapeutic action to a person's foot

Dan Manor; Roni Bibi; Eli Levy; Ascher Shmulewitz


Archive | 1999

Apparatus for foot dorsiflexion and method therefor

Dan Manor; Roni Bibi; Eli Levy


Archive | 2006

Method and apparatus for use with doppler measurements in medical applications

Dan Manor; Eli Levi; Adi Yosef


Archive | 1999

Sonde a deux transducteurs ultrasonores, destinee a la mesure du debit sanguin, et procede de determination du diametre de vaisseaux sanguins

Dan Manor; Eli Levy; Roni Bibi

Collaboration


Dive into the Dan Manor's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jean F. Soustiel

Technion – Israel Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Menashe Zaaroor

Technion – Israel Institute of Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge