Dario Faj
Josip Juraj Strossmayer University of Osijek
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Dario Faj.
American Journal of Roentgenology | 2009
Virginia Tsapaki; Nada A. Ahmed; Jamila Salem Al-Suwaidi; Adnan Beganovic; Abdelkader Benider; Latifa BenOmrane; Rada Borisova; S. Economides; Leila El-Nachef; Dario Faj; Ashot Hovhannesyan; M. H. Kharita; Nadia Khelassi-Toutaoui; Nisakorn Manatrakul; Ilkhom Mirsaidov; Mohamed Shaaban; Ion Ursulean; Jeska Sidika Wambani; Areesha Zaman; Julius Ziliukas; Dejan Zontar; Madan M. Rehani
OBJECTIVE The purpose of our study was to investigate the level of radiation protection of patients and staff during interventional procedures in 20 countries of Africa, Asia, and Europe. SUBJECTS AND METHODS In a multinational prospective study, information on radiation protection tools, peak skin dose (PSD), and kerma-area product (KAP) was provided by 55 hospitals in 20 mainly developing countries (nine mostly in Eastern Europe, five in Africa, and six in Asia). RESULTS Nearly 40% of the interventional rooms had an annual workload of more than 2,000 patients. It is remarkable that the workload of pediatric interventional procedures can reach the levels of adult procedures even in developing countries. About 30% of participating countries have shown a 100% increase in workload in 3 years. Lead aprons are used in all participating rooms. Even though KAP was available in almost half of the facilities, none had experience in its use. One hundred of 505 patients monitored for PSD (20%) were above the 2-Gy threshold for deterministic effects. CONCLUSION Interventional procedures are increasing in developing countries, not only for adults but also for pediatric patients. The situation with respect to staff protection is considered generally acceptable, but this is not the case for patient protection. Many patients exceeded the dose threshold for erythema. A substantial number (62%) of percutaneous transluminal coronary angioplasty procedures performed in developing countries in this study are above the currently known dose reference level and thus could be optimized. Therefore, this study has significance in introducing the concept of patient dose estimation and dose management.
American Journal of Roentgenology | 2012
Jenia Vassileva; Madan M. Rehani; Humoud Al-Dhuhli; Huda M. Al-Naemi; Jamila Salem Al-Suwaidi; Kimberly Appelgate; Danijela Arandjic; Einas Hamed Osman Bashier; Adnan Beganovic; Tony Benavente; Tadeusz Bieganski; Simone K. Dias; Leila El-Nachef; Dario Faj; Mirtha E. Gamarra-Sánchez; Juan Garcia-Aguilar; L’ubka Gbelcová; Vesna Gershan; Eduard Gershkevitsh; Edward Gruppetta; Alexandru Hustuc; Sonja Ivanović; Arif Jauhari; M. H. Kharita; Kharuzhyk Sa; Nadia Khelassi-Toutaoui; Hamid Reza Khosravi; Helen J. Khoury; Desislava Kostova-Lefterova; Ivana Kralik
OBJECTIVE The purpose of this study was to assess the frequency of pediatric CT in 40 less-resourced countries and to determine the level of appropriateness in CT use. MATERIALS AND METHODS Data on the increase in the number of CT examinations during 2007 and 2009 and appropriate use of CT examinations were collected, using standard forms, from 146 CT facilities at 126 hospitals. RESULTS The lowest frequency of pediatric CT examinations in 2009 was in European facilities (4.3%), and frequencies in Asia (12.2%) and Africa (7.8%) were twice as high. Head CT is the most common CT examination in children, amounting to nearly 75% of all pediatric CT examinations. Although regulations in many countries assign radiologists with the main responsibility of deciding whether a radiologic examination should be performed, in fact, radiologists alone were responsible for only 6.3% of situations. Written referral guidelines for imaging were not available in almost one half of the CT facilities. Appropriateness criteria for CT examinations in children did not always follow guidelines set by agencies, in particular, for patients with accidental head trauma, infants with congenital torticollis, children with possible ventriculoperitoneal shunt malfunction, and young children (< 5 years old) with acute sinusitis. In about one third of situations, nonavailability of previous images and records on previously received patient doses have the potential to lead to unnecessary examinations and radiation doses. CONCLUSION With increasing use of CT in children and a lack of use of appropriateness criteria, there is a strong need to implement guidelines to avoid unnecessary radiation doses to children.
Radiation Protection Dosimetry | 2010
Zoran Brnić; T. Krpan; Dario Faj; D. Kubelka; J. Popić Ramač; D. Posedel; R. Steiner; Vinko Vidjak; Vedran Brnić; K. Višković; V. Baraban
Apart from its benefits, the interventional cardiology (IC) is known to generate high radiation doses to patients and medical staff involved. The European Union Medical Exposures Directive 97/43/Euroatom strongly recommend patient dosimetry in interventional radiology, including IC. IC patient radiation doses in four representative IC rooms in Croatia were investigated. Setting reference levels for these procedures have difficulties due to the large difference in procedure complexity. Nevertheless, it is important that some guideline values are available as a benchmark to guide the operators during these potentially high-dose procedures. Local and national diagnostic reference levels (DRLs) were proposed as a guidance. A total of 138 diagnostic (coronary angiography, CA) and 151 therapeutic (PTCA, stenting) procedures were included. Patient irradiation was measured in terms of kerma-area product (KAP), fluoroscopy time (FT) and number of cine-frames (F). KAP was recorded using calibrated KAP-meters. DRLs of KAP, FT and F were calculated as third quartile values rounded up to the integer. Skin doses were assessed on a selected sample of high skin dose procedures, using radiochromic films, and peak skin doses (PSD) were presented. A relative large range of doses in IC was detected. National DRLs were proposed as follows: 32 Gy cm(2), 6.6 min and 610 frames for CA and 72 Gy cm(2), 19 min and 1270 frames for PTCA. PSD <1 Gy were measured in 72 % and PSD >2 Gy in 8 % of selected patients. Measuring the patient doses in radiological procedures is required by law, but rarely implemented in Croatia. The doses recorded in the study are acceptable when compared with the literature, but optimisation is possible. The preliminary DRL values proposed may be used as a guideline for local departments, and should be a basis for radiation reduction measures and quality assurance programmes in IC in Croatia.
Radiation Protection Dosimetry | 2008
Dario Faj; Dario Posedel; Damir Štimac; Zdravko Ivezić; Mladen Kasabašić; Ana Ivkovic; Dragan Kubelka; Vesna Ilakovac; Zoran Brnić; Olivera Ciraj Bjelac
A national audit of mammography equipment performance, image quality and dose has been conducted in Croatia. Film-processing parameters, optical density (OD), average glandular dose (AGD) to the standard breast, viewing conditions and image quality were examined using TOR(MAM) test object. Average film gradient ranged from 2.6 to 3.7, with a mean of 3.1. Tube voltage used for imaging of the standard 45 mm polymethylmethacrylate phantom ranged from 24 to 34 kV, and OD ranged from 0.75 to 1.94 with a mean of 1.26. AGD to the standard breast ranged from 0.4 to 2.3 mGy with a mean of 1.1 mGy. Besides clinical conditions, the authors have imaged the standard phantom in the referent conditions with 28 kV and OD as close as possible to 1.5. Then, AGD ranged from 0.5 to 2.6 mGy with a mean of 1.3 mGy. Image viewing conditions were generally unsatisfying with ambient light up to 500 lx and most of the viewing boxes with luminance between 1000 and 2000 cd per m(2). TOR(MAM) scoring of images taken in clinical and referent conditions was done by local radiologists in local image viewing conditions and by the referent radiologist in good image viewing conditions. Importance of OD and image viewing conditions for diagnostic information were analysed. The survey showed that the main problem in Croatia is the lack of written quality assurance/quality control (QA/QC) procedures. Consequently, equipment performance, image quality and dose are unstable and activities to improve image quality or to reduce the dose are not evidence-based. This survey also had an educational purpose, introducing in Croatia the QC based on European Commission Guidelines.
European Journal of Radiology | 2012
Olivera Ciraj-Bjelac; Simona Avramova-Cholakova; Adnan Beganovic; S. Economides; Dario Faj; Vesna Gershan; Edward Grupetta; M. H. Kharita; Milomir Milakovic; Constantin Milu; W. E. Muhogora; Pirunthavany Muthuvelu; Samuel Oola; Saeid Setayeshi; Cyril Schandorf; Ion Ursulean; Ivan Videnović; Areesha Zaman; Julius Ziliukas; Madan M. Rehani
PURPOSE The objective is to study mammography practice from an optimisation point of view by assessing the impact of simple and immediately implementable corrective actions on image quality. MATERIALS AND METHODS This prospective multinational study included 54 mammography units in 17 countries. More than 21,000 mammography images were evaluated using a three-level image quality scoring system. Following initial assessment, appropriate corrective actions were implemented and image quality was re-assessed in 24 units. RESULTS The fraction of images that were considered acceptable without any remark in the first phase (before the implementation of corrective actions) was 70% and 75% for cranio-caudal and medio-lateral oblique projections, respectively. The main causes for poor image quality before corrective actions were related to film processing, damaged or scratched image receptors, or film-screen combinations that are not spectrally matched, inappropriate radiographic techniques and lack of training. Average glandular dose to a standard breast was 1.5 mGy (mean and range 0.59-3.2 mGy). After optimisation the frequency of poor quality images decreased, but the relative contributions of the various causes remained similar. Image quality improvements following appropriate corrective actions were up to 50 percentage points in some facilities. CONCLUSIONS Poor image quality is a major source of unnecessary radiation dose to the breast. An increased awareness of good quality mammograms is of particular importance for countries that are moving towards introduction of population-based screening programmes. The study demonstrated how simple and low-cost measures can be a valuable tool in improving of image quality in mammography.
European Journal of Radiology | 2011
Olivera Ciraj-Bjelac; Dario Faj; Damir Štimac; Dusko Kosutic; Danijela Arandjic; Hrvoje Brkić
The purpose of this study is to investigate the need for and the possible achievements of a comprehensive QA programme and to look at effects of simple corrective actions on image quality in Croatia and in Serbia. The paper focuses on activities related to the technical and radiological aspects of QA. The methodology consisted of two phases. The aim of the first phase was the initial assessment of mammography practice in terms of image quality, patient dose and equipment performance in selected number of mammography units in Croatia and Serbia. Subsequently, corrective actions were suggested and implemented. Then the same parameters were re-assessed. Most of the suggested corrective actions were simple, low-cost and possible to implement immediately, as these were related to working habits in mammography units, such as film processing and darkroom conditions. It has been demonstrated how simple quantitative assessment of image quality can be used for optimisation purposes. Analysis of image quality parameters as OD, gradient and contrast demonstrated general similarities between mammography practices in Croatia and Serbia. The applied methodology should be expanded to larger number of hospitals and applied on a regular basis.
Medical Dosimetry | 2010
Mladen Kasabašić; Dario Faj; Ana Ivkovic; Slaven Jurković; Nenad Belaj
Patients with cervical, uterine, and rectal carcinomas are usually treated in the prone position using the bellyboard positioning device. Specific and uncomfortable prone position gives rise to uncertainties in the daily set-up of patients during the treatment. During investigation of translational movements, rotational movements of the pelvis are observed and investigated. The film portal imaging is used to discover patient positioning errors during treatment. We defined the rotational set-up errors by angle deviations of the sacrum. Thirty-six patients were included in the study; 15 patients were followed during the whole treatment and 21 during the first 5 consecutive treatment days. The image acquisitions were completed in 84%. Systematic and random positioning errors were analyzed in 725 images. Approximately half of the patients had adjusted to the bellyboard in the first few fractions, with sacrum angles remaining the same for the rest of the treatment. The other half had drifts of the sacrum angle during the whole treatment. The rotation of the sacrum during treatment ranged up to 14 degrees , causing the usual set-up verification and correction procedure to result in errors up to 15 mm. Rotational movements of the patient pelvis during bellyboard pelvis radiotherapy can introduce considerable patient position error.
Journal of Radioanalytical and Nuclear Chemistry | 2003
Josip Planinić; Dario Faj; Branko Vuković; Zdravko Faj; Vanja Radolić; Božica Šuveljak
Although studies of radon exposure have established that Rn decay products are a cause of lung cancer among miners, the lung cancer risk to the general population from indoor radon remains unclear and controversial. Our epidemiological investigation of indoor radon influence on lung cancer incidence was carried out for 201 patients from the Osijek town. Ecological method was applied by using the town map with square fields of 1 km2 and the town was divided into 24 fields. Multiple regression study for the lung cancer rate on field, average indoor radon exposure and smoking showed a positive linear double regression for the mentioned variables. Case-control study showed that patients, diseased of lung cancer, dwelt in homes with significantly higher radon concentrations, by comparison to the average indoor radon level of control sample.
Radiology and Oncology | 2011
Slaven Jurković; Gordana Zauhar; Dario Faj; Deni Smilovic Radojcic; Manda Švabić; Mladen Kasabašić; Ana Diklić
Dosimetric verification of compensated beams using radiographic film Introduction. External photon beam modulation using compensators in order to achieve a desired dose distribution when brachytherapy treatment is followed by external beam radiation is a well-established technique. A compensator modulates the central part of the beam, and the dose beneath the thickest part of the compensator is delivered mostly by scattered, low energy photons. A two-dimensional detector with a good spatial resolution is needed for the verification of those beams. In this work, the influence of different types of detectors on the measured modulated dose distributions was examined. Materials and methods. Dosimetric verification was performed using X-Omat V, Eastman Kodak radiographic films at different depths in a solid water phantom. The film measurements were compared with those made by ionization chambers. Photon beams were also modelled using EGSnrc Monte Carlo algorithm to explain the measured results. Results. Monte Carlo calculated over-response of the film under the thickest part of the compensator was over 15%, which was confirmed by measurements. The magnitude of over-response could be associated with changes in the spectra of photon energy in the beam. Conclusions. The radiographic film can be used for the dosimetry of compensated high energy photon beams, with limitations in volumes where photon spectra are hardly degraded.
European Journal of Radiology | 2012
Zoran Brnić; Darko Blašković; Branimir Klasić; Jelena Popić Ramač; Mirjana Flegarić-Bradić; Damir Štimac; Ivan Zvonimir Lubina; Vedran Brnić; Dario Faj
PURPOSE The study was aimed to provide objective evidence about the mammographic image quality in Croatia, to compare it between different types of MG facilities and to identify the most common deficiencies and possible reasons as well as the steps needed to improve image quality. MATERIALS AND METHODS A total of 420 mammographic examinations collected from 84 mammographic units participating in the Croatian nationwide breast cancer screening program were reviewed in terms of four image quality categories: identification of patient and examination, breast positioning and compression, exposure and contrast, and artifacts. Those were rated using image evaluating system based on American College of Radiology and European Commission proposals. The results were compared among different types of mammographic units, and common image quality deficiencies were identified. RESULTS Total image quality scores of 12.8, 16.1, 13.0 and 13.7 were found for general hospitals, university hospitals, private clinics and public healthcare centres, respectively. Average score for all mammographic units was 13.5 (out of 25 points). University hospitals were significantly better than all other mammography units in overall image quality, which was mostly contributed by better breast positioning practices. Private clinics showed the worst results in identification, exposure, contrast and artifacts. CONCLUSIONS Serious deficiencies in identification and breast positioning, which might compromise breast cancer screening outcome, were detected in our material. They occur mainly due to subjective reasons and could be corrected through additional staff training and improvement of working discipline.