Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Darren Haskett is active.

Publication


Featured researches published by Darren Haskett.


Journal of Biomechanical Engineering-transactions of The Asme | 2011

Adaptation of a planar microbiaxial optomechanical device for the tubular biaxial microstructural and macroscopic characterization of small vascular tissues.

Joseph T. Keyes; Darren Haskett; Urs Utzinger; Mohamad Azhar; Jonathan P. Vande Geest

Murine models of disease are a powerful tool for researchers to gain insight into disease formation, progression, and therapies. The biomechanical indicators of diseased tissue provide a unique insight into some of these murine models, since the biomechanical properties in scenarios such as aneurysm and Marfan syndrome can dictate tissue failure and mortality. Understanding the properties of the tissue on the macroscopic scale has been shown to be important, as one can then understand the tissues ability to withstand the high stresses seen in the cardiac pulsatile cycle. Alterations in the biomechanical response can foreshadow prospective mechanical failure of the tissue. These alterations are often seen on the microstructural level, and obtaining detailed information on such changes can offer a better understanding of the phenomena seen on the macroscopic level. Unfortunately, mouse models present problems due to the size and delicate features in the mechanical testing of such tissues. In addition, some smaller arteries in large-animal studies (e.g., coronary and cerebral arteries) can present the same issues, and are sometimes unsuitable for planar biaxial testing. The purpose of this paper is to present a robust method for the investigation of the mechanical properties of small arteries and the classification of the microstructural orientation and degree of fiber alignment. This occurs through the cost-efficient modification of a planar biaxial tester that works in conjunction with a two-photon nonlinear microscope. This system provides a means to further investigate how microstructure and mechanical properties are modified in diseased transgenic animals where the tissue is in small tube form. Several other hard-to-test tubular specimens such as cerebral aneurysm arteries and atherosclerotic coronary arteries can also be tested using the described modular device.


Cell and Tissue Research | 2012

Altered tissue behavior of a non-aneurysmal descending thoracic aorta in the mouse model of Marfan syndrome

Darren Haskett; Jefferson J. Doyle; Connie Gard; Hwudaurw Chen; Corbie Ball; Mark A. Estabrook; Alejandra D.C. Encinas; Harry C. Dietz; Urs Utzinger; Jonathan P. Vande Geest; Mohamad Azhar

Aortic aneurysm is predominantly found in the ascending aorta in patients with Marfan syndrome (MFS). However, descending aortic disease has emerged as a problem since people are living longer because of improved medical and surgical management of the ascending aorta. Diagnostic procedures before disease onset and the mechanisms involved in the transition of normal aortic tissue to aneurysm remain unclear. We determined signs of descending aortic disease before disease onset in mice with a mutation in the fibrillin 1 gene (Fbn1+/C1039G), a validated mouse model of disease susceptibility and progression of aortic aneurysm of MFS. We analyzed a tubular unfixed non-aneurysmal descending thoracic aorta from 8-month-old wild-type and Fbn1+/C1039G mice by a tubular biaxial tester that works in conjunction with a two-photon nonlinear microscope. Fbn1+/C1039G mouse aorta was more compliant in the circumferential direction. Two-photon imaging showed defective organization of adventitial collagen fibers in the pressurized aortas of Fbn1+/C1039G mice. Moreover, disruption in the elastic lamina was noted in the absence of aneurysms in pressurized aortas but not unpressurized aortas of Fbn1+/C1039G mice. At the molecular level, this altered tissue behavior in non-aneurysmal descending aortas of Fbn1+/C1039G mice was accompanied by an increasing trend of canonical but not noncanonical, transforming growth factor-β (TGFβ) signaling. Finally, assays of in vitro collagen lattice formation in mouse wild-type and TGFβ1-deficient embryonic fibroblasts indicate that TGFβ1 can regulate collagen organization. The ability to reveal the presence of altered biomechanics and microstructure coupled with subtle changes in TGFβ signaling provides a novel surrogate measure of tissue susceptibility to aneurysm before disease onset.


Biomaterials | 2015

TGFβ2 differentially modulates smooth muscle cell proliferation and migration in electrospun gelatin-fibrinogen constructs.

Diana Catalina Ardila; Ehab Tamimi; Forest L. Danford; Darren Haskett; Robert S. Kellar; Thomas Doetschman; Jonathan P. Vande Geest

A main goal of tissue engineering is the development of scaffolds that replace, restore and improve injured tissue. These scaffolds have to mimic natural tissue, constituted by an extracellular matrix (ECM) support, cells attached to the ECM, and signaling molecules such as growth factors that regulate cell function. In this study we created electrospun flat sheet scaffolds using different compositions of gelatin and fibrinogen. Smooth muscle cells (SMCs) were seeded on the scaffolds, and proliferation and infiltration were evaluated. Additionally, different concentrations of Transforming Growth Factor-beta2 (TGFβ2) were added to the medium with the aim of elucidating its effect on cell proliferation, migration and collagen production. Our results demonstrated that a scaffold with a composition of 80% gelatin-20% fibrinogen is suitable for tissue engineering applications since it promotes cell growth and migration. The addition of TGFβ2 at low concentrations (≤ 1 ng/ml) to the culture medium resulted in an increase in SMC proliferation and scaffold infiltration, and in the reduction of collagen production. In contrast, TGFβ2 at concentrations >1 ng/ml inhibited cell proliferation and migration while stimulating collagen production. According to our results TGFβ2 concentration has a differential effect on SMC function and thus can be used as a biochemical modulator that can be beneficial for tissue engineering applications.


Journal of Biomechanics | 2012

The effects of angiotensin II on the coupled microstructural and biomechanical response of C57BL/6 mouse aorta

Darren Haskett; Erin Speicher; Marie Fouts; Doug Larson; Mohamad Azhar; Urs Utzinger; Jonathan P. Vande Geest

RATIONALE Abdominal aortic aneurysm (AAA) is a complex disease that leads to a localized dilation of the infrarenal aorta, the rupture of which is associated with significant morbidity and mortality. Animal models of AAA can be used to study how changes in the microstructural and biomechanical behavior of aortic tissues develop as disease progresses in these animals. We chose here to investigate the effect of angiotensin II (AngII) in C57BL/6 mice as a first step towards understanding how such changes occur in the established ApoE(-/-) AngII infused mouse model of AAA. OBJECTIVE The objective of this study was to utilize a recently developed device in our laboratory to determine how the microstructural and biomechanical properties of AngII-infused C57BL/6 wildtype mouse aorta change following 14 days of AngII infusion. METHODS C57BL/6 wildtype mice were infused with either saline or AngII for 14 day. Aortas were excised and tested using a device capable of simultaneously characterizing the biaxial mechanical response and load-dependent (unfixed, unfrozen) extracellular matrix organization of mouse aorta (using multiphoton microscopy). Peak strains and stiffness values were compared across experimental groups, and both datasets were fit to a Fung-type constitutive model. The mean mode and full width at half maximum (FWHM) of fiber histograms from two photon microscopy were quantified in order to assess the preferred fiber distribution and degree of fiber splay, respectively. RESULTS The axial stiffness of all mouse aorta was found to be an order of magnitude larger than the circumferential stiffness. The aortic diameter was found to be significantly increased for the AngII infused mice as compared to saline infused control (p=0.026). Aneurysm, defined as a percent increase in maximum diameter of 30% (defined with respect to saline control), was found in 3 of the 6 AngII infused mice. These three mice displayed adventitial collagen that lacked characteristic fiber crimp. The biomechanical response in the AngII infused mice showed significantly reduced circumferential compliance. We also noticed that the ability of the adventitial collagen fibers in AngII infused mice to disperse in reaction to circumferential loading was suppressed. CONCLUSIONS Collagen remodeling is present following 14 days of AngII infusion in C57BL/6 mice. Aneurysmal development occurred in 50% of our AngII infused mice, and these dilatations were accompanied with adventitial collagen remodeling and decreased circumferential compliance.


Journal of Biomechanical Engineering-transactions of The Asme | 2015

Biomechanical Comparison of Glutaraldehyde-Crosslinked Gelatin Fibrinogen Electrospun Scaffolds to Porcine Coronary Arteries

Ehab Tamimi; Diana Catalina Ardila; Darren Haskett; Thomas Doetschman; Marvin J. Slepian; Robert S. Kellar; J. P. Vande Geest

Cardiovascular disease (CVD) is the leading cause of death for Americans. As coronary artery bypass graft surgery (CABG) remains a mainstay of therapy for CVD and native vein grafts are limited by issues of supply and lifespan, an effective readily available tissue-engineered vascular graft (TEVG) for use in CABG would provide drastic improvements in patient care. Biomechanical mismatch between vascular grafts and native vasculature has been shown to be the major cause of graft failure, and therefore, there is need for compliance-matched biocompatible TEVGs for clinical implantation. The current study investigates the biaxial mechanical characterization of acellular electrospun glutaraldehyde (GLUT) vapor-crosslinked gelatin/fibrinogen cylindrical constructs, using a custom-made microbiaxial optomechanical device (MOD). Constructs crosslinked for 2, 8, and 24 hrs are compared to mechanically characterized porcine left anterior descending coronary (LADC) artery. The mechanical response data were used for constitutive modeling using a modified Fung strain energy equation. The results showed that constructs crosslinked for 2 and 8 hrs exhibited circumferential and axial tangential moduli (ATM) similar to that of the LADC. Furthermore, the 8-hrs experimental group was the only one to compliance-match the LADC, with compliance values of 0.0006±0.00018 mm Hg-1 and 0.00071±0.00027 mm Hg-1, respectively. The results of this study show the feasibility of meeting mechanical specifications expected of native arteries through manipulating GLUT vapor crosslinking time. The comprehensive mechanical characterization of cylindrical biopolymer constructs in this study is an important first step to successfully develop a biopolymer compliance-matched TEVG.


Biomatter | 2013

Progressive alterations in microstructural organization and biomechanical response in the ApoE mouse model of aneurysm

Darren Haskett; Mohamad Azhar; Urs Utzinger; Jonathan P. Vande Geest

AAA is a complex disease that leads to a localized dilation of the infrarenal aorta that develops over years. Longitudinal information in humans has been difficult to obtain for this disease, therefore mouse models have become increasingly used to study the development of AAAs. The objective of this study was to determine any changes that occur in the biomechanical response and fiber microstructure in the ApoE−/− AngII mouse model of aneurysm during disease progression. Adult ApoE−/− AngII infused mice along with wild-type controls were taken at 14 and 28 d. Aortas were excised and tested simultaneously for biaxial mechanical response and ECM organization. Data sets were fit to a Fung-type constitutive model to give peak strains and stiffness values. Images from two photon microscopy were quantified in order to assess the preferred fiber alignment and degree of fiber orientation. Biomechanical results found significant differences that were present at 14 d had returned to normal by 28 d along with significant changes in fiber orientation and dispersion indicating remodeling occurring within the aneurysmal wall. This return of some of the normal biomechanical function, in addition the continuing changes that occur in the microstructure suggest a restorative response that occurs in the ApoE−/− AngII infused model after the initial aneurysm formation.


ASME 2009 Summer Bioengineering Conference, Parts A and B | 2009

Age and Location Dependent Microstructural and Biomechanical Characterization of Human Aortas

Darren Haskett; Greg Johnson; Jonathan P. Vande Geest

The stiffening of the aorta with age is well documented in humans [1]. Collagen, elastin and smooth muscle cells are primarily responsible for the load bearing functionality of the human aorta, and it is generally accepted that imbalances in the organization of these components occur with age and in the presence of disease [2]. While a detailed account of the structural organization of the human aorta has been reported by a few investigators, none of these quantify simultaneously the organization of both collagen and elastin and how these change with age and location along the aortic tree. Additionally, none of these studies accurately assess how these changes result in corresponding alterations in the biomechanical function of the aorta.Copyright


Microscopy and Microanalysis | 2016

2-Photon Characterization of Optical Proteolytic Beacons for Imaging Changes in Matrix-Metalloprotease Activity in a Mouse Model of Aneurysm.

Darren Haskett; David Maestas; Stephen J. Howerton; Tyler Smith; D. Catalina Ardila; Thomas Doetschman; Urs Utzinger; Dominic V. McGrath; J. Oliver McIntyre; Jonathan P. Vande Geest

Abdominal aortic aneurysm is a multifactorial disease that is a leading cause of death in developed countries. Matrix-metalloproteases (MMPs) are part of the disease process, however, assessing their role in disease initiation and progression has been difficult and animal models have become essential. Combining Förster resonance energy transfer (FRET) proteolytic beacons activated in the presence of MMPs with 2-photon microscopy allows for a novel method of evaluating MMP activity within the extracellular matrix (ECM). Single and 2-photon spectra for proteolytic beacons were determined in vitro. Ex vivo experiments using the apolipoprotein E knockout angiotensin II-infused mouse model of aneurysm imaged ECM architecture simultaneously with the MMP-activated FRET beacons. 2-photon spectra of the two-color proteolytic beacons showed peaks for the individual fluorophores that enable imaging of MMP activity through proteolytic cleavage. Ex vivo imaging of the beacons within the ECM revealed both microstructure and MMP activity. 2-photon imaging of the beacons in aneurysmal tissue showed an increase in proteolytic cleavage within the ECM (p<0.001), thus indicating an increase in MMP activity. Our data suggest that FRET-based proteolytic beacons show promise in assessing MMP activity within the ECM and will therefore allow future studies to identify the heterogeneous distribution of simultaneous ECM remodeling and protease activity in aneurysmal disease.


ASME 2012 Summer Bioengineering Conference, Parts A and B | 2012

Progressive alterations in biomechanical response of a mouse model of aneurysm

Darren Haskett; Urs Utzinger; Mohamad Azhar; Jonathan P. Vande Geest

Abdominal aortic aneurysm (AAA) is a complex disease that leads to a localized dilation of the infrarenal aorta, the rupture of which is associated with significant morbidity and mortality, however the underlying mechanisms by which such changes remains an important unanswered question in the literature. Animal models of AAA can be used to study how changes in the microstructural and biomechanical behavior of aortic tissues develop as disease progresses in these animals. We chose here to investigate changes in mechanical characteristics with time in the established Apolipoprotein E deficient (ApoE−/−) angiotensin II (AngII) infused mouse model of AAA.Copyright


ASME 2011 Summer Bioengineering Conference, Parts A and B | 2011

Biomechanical and microstructural analysis of wildtype (C57BL6) mouse aorta

Darren Haskett; Greg Johnson; Mohamad Azhar; Jonathan P. Vande Geest

It is generally accepted that the formation of an aneurysm in the infrarenal aorta is a complex and multi-factorial disease, however little is known about how biomechanical factors may play a role in the progression of aneurysmal disease. Although it is known that human aneurysmal tissue is remodeled in the disease process [1] and that such reorganization leads to altered function [2], the underlying mechanisms by which such changes remains an important unanswered question in the literature. The purpose of this study is to develop a means for determining the biomechanical alterations that occur within the aorta to better understand aneurysmal disease progression.Copyright

Collaboration


Dive into the Darren Haskett's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge