David Castro
King Abdullah University of Science and Technology
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by David Castro.
nano/micro engineered and molecular systems | 2015
Arpys Arevalo; E. Byas; David Conchouso; David Castro; Saad Ilyas; Ian G. Foulds
This paper reports a versatile multi-user micro-fabrication process for MEMS devices, the “Polyimide MEMS Multi-User Process” (PiMMPs). The reported process uses polyimide as the structural material and three separate metallization layers that can be interconnected depending on the desired application. This process enables for the first time the development of out-of-plane compliant mechanisms that can be designed using six different physical principles for actuation and sensing on a wafer from a single fabrication run. These principles are electrostatic motion, thermal bimorph actuation, capacitive sensing, magnetic sensing, thermocouple-based sensing and radio frequency transmission and reception.
international conference on micro electro mechanical systems | 2013
David Castro; Patrick Ingram; Rimantas Kodzius; David Conchouso; Euisik Yoon; Ian G. Foulds
This paper reports on solid UV cross-linked Poly(ethylene)-glycol-diacrylate (PEGDA) as a material for microfluidic devices for biological applications. We have evaluated biocompatibility of PEGDA through two separate means: 1) by examining cell viability and attachment on cross-linked PEGDA surfaces for cell culture applications, and 2) by determining if cross-linked PEGDA inhibits the polymerase chain reaction (PCR) processes for on-chip PCR. Through these studies a correlation has been found between degree of curing and cell viability, attachment, as well as on PCR outcome.
international conference on micro electro mechanical systems | 2011
M. Valencia; T. Atallah; David Castro; David Conchouso; M. Dosari; R. Hammad; Ehab Rawashdeh; Amir Zaher; Jürgen Kosel; Ian G. Foulds
This paper presents the design, simulation, fabrication and testing of novel, untethered SU-8 polymer microrobots based on scratch drive actuators (SDAs). The design consists of two 100×120×10µm linked SDAs, individually operated close to their resonant frequencies. The resonant frequency and deflection behavior of an individual SDA can be controlled by its shape, thickness, and stiffening design features. As a result, paired SDAs can be actuated individually or simultaneously by a multifrequency driving signal, allowing for two-dimensional displacement. The fabrication process uses SU-8 as structural material and PMGI as sacrificial material. The SU-8 provides a flexible material for the SDAs plates as well as the bushing. Finally, a Cr/Au layer is blanket deposited to provide electrical conductivity.
international conference on computer modelling and simulation | 2013
David Conchouso; Arpys Arevalo; David Castro; Ehab Rawashdeh; Manuel Valencia; Amir Zaher; Jürgen Kosel; Ian G. Foulds
This paper presents the simulation of Scratch Drive Actuators (SDAs) for micro-robotic applications. SDAs use electrostatic forces to generate motion on top of an interdigitated electrode array. The purpose of this investigation is to evaluate several design geometries and micro-actuator configurations using ConventorWare®s finite element analysis module. The study performed investigates the SDAs modal and electrostatic behavior and the effects of linking two or more SDAs together in a micro- robot device. In addition, the interdigitated electrode array performance, used for power delivery, was studied by changing the thickness of its dielectric layer. We present our observations based on these studies, which will aid in the understanding and development of future SDA designs.
nano/micro engineered and molecular systems | 2015
David Conchouso; Arpys Arevalo; David Castro; Ian G. Foulds
This paper reports on the Buckled Cantilever Platform (BCP) that allows the manipulation of the out of plane structures through the adjustment of the pitch angle using thermal bimorph micro-actuators. Due to the micro-fabrication process used, the bimorph actuators can be designed to move in both: Counter Clockwise (CCW) and Clockwise (CW) directions with a resolution of up to 110 μm/V, with smallest step in the range of nanometers. Thermal and electrical characterization of the thermal bimorph actuators showed low influence in the platforms temperature and low power consumption (<; 35μW) mainly due to the natural isolation of the structure. Tip displacements larger than 500μm were achieved. The precise angle adjustment achieved through these mechanisms makes them optimal for a range of different MEMS applications, like optical benches and low frequency sweeping sensors and antennas.
nano/micro engineered and molecular systems | 2015
Arpys Arevalo; David Conchouso; David Castro; Nizar Jaber; Mohammad I. Younis; Ian G. Foulds
In this paper we report the fabrication and characterization of a single piezoelectric actuator for digital sound reconstruction. This work is the first step towards the implementation of a true digital micro-loudspeaker by means of an array of acoustic actuators. These actuators consist of a flexible membrane fabricated using polyimide, which is actuated using a Lead-Zirconate-Titanate (PZT) piezoelectric ceramic layer working in the d31 actuation mode. The dimensions of the membrane are of 1mm diameter and 4μm in thickness, which is capable of being symmetrically actuated in both upward and downward directions, due to the back etch step releasing the membrane. Our electrical characterization shows an improvement in the polarization of the piezoelectric material after its final etch patterning step, and our mechanical characterization shows the natural modes of resonance of the stacked membrane.
nano micro engineered and molecular systems | 2016
David Conchouso; Arpys Arevalo; Garret McKerricher; David Castro; Ian G. Foulds
This paper reports on a radio frequency micro-strip T-resonator that is integrated to a parallel droplet microfluidic system. The T-resonator works as a feedback system to monitor uniform droplet production and to detect, in real-time, any malfunctions due to channel fouling or clogging. Emulsions at different W/O flow-rate ratios are generated in a microfluidic device containing 8 parallelized generators. These emulsions are then guided towards the RF sensor, which is then read using a Network Analyzer to obtain the frequency response of the system. The proposed T-resonator shows frequency shifts of 45MHz for only 5% change in the emulsions water in oil content. These shifts can then be used as a feedback system to trigger alarms and notify production and quality control engineers about problems in the droplet generation process.
nano micro engineered and molecular systems | 2016
David Conchouso; Arpys Arevalo; David Castro; Mincho Kavaldzhiev; Ian G. Foulds
This paper presents a capacitive sensor for monitoring parallel microfluidic droplet generation. The great electric permittivity difference between common droplet microfluidic fluids such as air, oil and water (εoil ≈ 2-3 and εwater ≈ 80.4), allows for accurate detection of water in oil concentration changes. Capacitance variations as large as 10 pF between a channel filled with water or dodecane, are used to continuously monitor the output of a parallelization system producing 150 μl/min of water in dodecane emulsions. We also discuss a low cost fabrication process to manufacture these capacitive sensors, which can be integrated to different substrates.
international conference on micro electro mechanical systems | 2016
Arpys Arevalo; David Castro; David Conchouso; Jürgen Kosel; Ian G. Foulds
This paper reports on the design and fabrication of MEMS actuator arrays suitable for Digital Sound reconstruction and Parametric Directional Loudspeakers. Two distinct versions of the device were fabricated: one using the electrostatic principle actuation and the other one, the piezoelectric principle. Both versions used similar membrane dimensions, with a diameter of 500 μm. These devices are the smallest Micro-Machined Ultrasound Transducer (MUT) arrays that can be operated for both modes: Digital Sound Reconstruction and Parametric Loudspeaker. The chips consist of an array with 256 transducers, in a footprint of 12 mm by 12 mm. The total single chip size is: 2.3 cm by 2.3 cm, including the contact pads.
Genes | 2018
David Castro; David Conchouso; Rimantas Kodzius; Arpys Arevalo; Ian G. Foulds
In this paper, we present a two-phase microfluidic system capable of incubating and quantifying microbead-based agglutination assays. The microfluidic system is based on a simple fabrication solution, which requires only laboratory tubing filled with carrier oil, driven by negative pressure using a syringe pump. We provide a user-friendly interface, in which a pipette is used to insert single droplets of a 1.25-µL volume into a system that is continuously running and therefore works entirely on demand without the need for stopping, resetting or washing the system. These assays are incubated by highly efficient passive mixing with a sample-to-answer time of 2.5 min, a 5–10-fold improvement over traditional agglutination assays. We study system parameters such as channel length, incubation time and flow speed to select optimal assay conditions, using the streptavidin-biotin interaction as a model analyte quantified using optical image processing. We then investigate the effect of changing the concentration of both analyte and microbead concentrations, with a minimum detection limit of 100 ng/mL. The system can be both low- and high-throughput, depending on the rate at which assays are inserted. In our experiments, we were able to easily produce throughputs of 360 assays per hour by simple manual pipetting, which could be increased even further by automation and parallelization. Agglutination assays are a versatile tool, capable of detecting an ever-growing catalog of infectious diseases, proteins and metabolites. A system such as this one is a step towards being able to produce high-throughput microfluidic diagnostic solutions with widespread adoption. The development of analytical techniques in the microfluidic format, such as the one presented in this work, is an important step in being able to continuously monitor the performance and microfluidic outputs of organ-on-chip devices.