Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where David E. Huddleston is active.

Publication


Featured researches published by David E. Huddleston.


nuclear science symposium and medical imaging conference | 2014

Development of the dual-sided microstructured semiconductor neutron detector

Ryan G. Fronk; Steven L. Bellinger; Luke C. Henson; David E. Huddleston; Taylor R. Ochs; Colten T. Smith; Timothy J. Sobering; Cody J. Rietcheck; R.D. Taylor; J. Kenneth Shultis; Douglas S. McGregor

Microstructured semiconductor neutron detectors (MSNDs) have long been investigated as a replacement for inefficient thin-film-coated semiconductor neutron detectors. Thin-film-coated semiconductor thermal neutron detection efficiency is restricted to 4-5%. MSNDs improved upon these devices with etched perforations into the diode backfilled with neutron conversion material. Neutron absorption and reaction-product detection efficiency was greatly improved, leading to theoretical intrinsic thermal neutron detection efficiencies greater than 45%. Previous attempts at double-stacking MSNDs to increase the detection efficiency were successful, but were accomplished with great difficulty, where device alignment and proved to be challenging. The development of the dual-sided microstructured semiconductor neutron detector (DSMSND) provides the simplicity of a single device with the detection efficiency of a double-stacked detector. Trenches were etched into the top and bottom of a single vertical pvn-junction Si diode and backfilled with 6LiF neutron conversion material. The first such devices fabricated yielded thermal neutron detection efficiencies between 9.6-16.6%. Theoretical intrinsic thermal neutron detection efficiencies of greater than 79% are possible with a single 1-mm thick silicon diode.


nuclear science symposium and medical imaging conference | 2015

Advancements on dual-sided microstructured semiconductor neutron detectors (DSMSNDs)

Ryan G. Fronk; Steven L. Bellinger; Luke C. Henson; David E. Huddleston; Taylor R. Ochs; Cody J. Rietcheck; Colten T. Smith; J. Kenneth Shultis; Timothy J. Sobering; Douglas S. McGregor

Microstructured semiconductor neutron detectors (MSNDs) represent a low-cost, high-efficiency means of solid-state thermal neutron detection. Trenches are etched into a pn-junction diode and backfilled with nano-sized 6LiF neutron converting material. Neutrons absorbed within the conversion material produce charged particle reaction products that interact within the semiconductor substrate and generate electron-hole pairs. The electron-hole pairs are collected by the applied bias, generating an electronic pulse and indicating a neutron event. Presently, single-sided MSNDs performance is approaching the theoretical maximum detection efficiency, with devices nearing 35% intrinsic thermal neutron detection efficiency. Single-sided MSNDs are limited in their detection efficiency due to neutron streaming between the trenches; incident neutrons will pass through the semiconductor substrate without detection. Dual-side microstructured semiconductor neutron detectors (DSMSNDs) alleviate this issue with an additional set of trenches etched into the backside of the diode. Neutrons streaming through the first set of trenches can be absorbed in the second set of trenches. Careful design of DSMSNDs can allow for detection efficiencies exceeding 70% for a single 1-mm thick detector. DSMSNDs etched 20-μm wide, 350-μm deep trenches, and 10-μm wide fins have achieved an intrinsic thermal neutron detection efficiency of 53.54±0.61% for neutrons normally incident on the front face of the detector using p-type contacts on both the front- and back-side fins.


nuclear science symposium and medical imaging conference | 2012

Portable neutron energy spectrometer utilizing microstructured semiconductor neutron detectors (MSND)

Brian W Cooper; Steven L. Bellinger; Simon R. Bolding; Anthony N. Caruso; Ryan G. Fronk; William H. Miller; Thomas M. Oakes; J. Kenneth Shultis; Timothy J. Sobering; R.D. Taylor; David E. Huddleston; Douglas S. McGregor

The portable neutron energy spectrometer is designed to identify an unknown neutron source. The spectrometer is cylindrical in shape with a diameter of 12 cm and a length of 33 cm. This allows for a large surface area for incident neutrons to interact with and sufficient moderating material to thermalize neutrons up to 14.1 MeV in energy. The spectrometer utilizes eleven 2 cm × 2 cm high-efficiency microstructured semiconductor neutron detector (MSND) devices. The detectors are arranged linearly along the central axis of the spectrometer. The spectrometers volume consists of alternating layers of MSNDs, high-density polyethylene (HDPE), and cadmium. The HDPE acts as a moderator for the epithermal and fast neutrons, allowing them to disperse energy linearly within the spectrometers volume thereby, becoming thermalized and counted by the detectors. The 2 mm thick cadmium layer after each detector prevents thermal neutrons from backscattering to a previous detector. Extensive modeling of the portable spectrometer was conducted using MCNPS. The modeling was used to optimize the number of MSNDs and the thickness of the HDPE layers. Also, reference library templates for a variety neutron sources were simulated, including; 252Cf, 252Cf + D2O, PuBe, AmBe, and a 14.1 MeV fusion neutron source. A Figure-of-Merit calculation was used to identify the experimental neutron source. The spectrometer is a light-weight, portable, self-contained unit, weighing less than 20 lbs. It is powered by a rechargeable 6V battery contained within the main housing. The measurement data and identified neutron source information is displayed on the built-in LCD screen.


IEEE Transactions on Nuclear Science | 2017

Present Status of the Microstructured Semiconductor Neutron Detector-Based Direct Helium-3 Replacement

Taylor R. Ochs; Steven L. Bellinger; Ryan G. Fronk; Luke C. Henson; David E. Huddleston; Zoairia I. Lyric; J. Kenneth Shultis; Colten T. Smith; Timothy J. Sobering; Douglas S. McGregor

A small form-factor, third-generation microstructured semiconductor neutron detector (MSND)-based <sup>3</sup>He replacement (HeRep Mk III) detector has been developed to serve as a direct replacement to expensive small-diameter, high-pressure <sup>3</sup>He gas-filled proportional neutron counters. Previously, the larger, 2-in diameter by 6-in-long HeRep Mk II utilized thirty 4-cm<sup>2</sup> active area single-sided MSNDs to replace a similarly sized 4-atm <sup>3</sup>He counter. The net count rate of the HeRep Mk II was 95.15% ± 9.04% of the net count rate of a similarly sized 4-atm <sup>3</sup>He detector for bare <sup>252</sup>Cf at a distance of 1 m. The HeRep Mk II net count rate measured 102.71% ±2.65% of the <sup>3</sup>He detector net count rate when each were placed in 6-in diameter by 9-in-long cylindrical high-density polyethylene (HDPE) moderator casks. The HeRep Mk III was developed as a test bed for new-generation dual-sided MSNDs (DSMSNDs), as well as for reduced-power electronics. The 0.75-in diameter by 4.50-in-long HeRep Mk III was populated with twelve 1-cm<sup>2</sup> active area DSMSNDs. The pvp-type diodes have thus far realized 53.54% ± 0.61% intrinsic thermal-neutron detection efficiency. The HeRep Mk III was tested against a 0.75-in diameter by 3.0-in-long 10-atm <sup>3</sup>He detector with a 30-ng <sup>252</sup>Cf source at a distance of 0.25 m. The HeRep Mk III reported 45.4% ± 0.3% and 56.7% ± 0.2% of the count rate of the 10-atm <sup>3</sup>He detector for detectors with no exterior moderator and in a 3-in by 5.75-in cylindrical HDPE moderator cask, respectively. The HeRep Mk III gamma-ray sensitivity was measured at a dose rate of 50 mR/hr from <sup>137</sup>Cs resulting in a net count rate of 0.01 cps, which corresponds to a gamma-ray rejection ratio of approximately 5:10<sup>7</sup>.


nuclear science symposium and medical imaging conference | 2016

Fourth-generation microstructured semiconductor neutron detector (MSND)-based 3 He replacement (HeRep) for high pressure 3 He detectors

Taylor R. Ochs; Steven L. Bellinger; Ryan G. Fronk; Luke C. Henson; David E. Huddleston; Graham E. Schlaikier; Timothy J. Sobering; Adam Van Bergeijk; Douglas S. McGregor

Two fourth-generation <sup>3</sup>He replacement (HeRep Mk IV) detectors based on microstructured semiconductor neutron detector (MSND) technology have been fabricated and characterized against a 0.75-in diameter by 3.0-in long, 10-atm <sup>3</sup>He neutron proportional counter. The HeRep Mk IV detectors have a 0.75-in by 0.75-in square form factor with one HeRep Mk IV measuring 3.1-in long and the other measuring 6.1-in long. Each HeRep Mk IV was populated with 15 DS-MSNDs that have an intrinsic thermal-neutron detection efficiency of approximately 50%. The void spaces between adjacent detectors in the 6.1-in long HeRep Mk IV were filled with HDPE moderator. The 3.1-in long HeRep Mk IV recorded 92.8 ± 1.8% of the count rate of the 10-atm <sup>3</sup>He detector for bare 26.5-ng <sup>252</sup>Cf, bare detector and 82.2 ± 0.9% for moderated <sup>252</sup>Cf source, moderated detector configurations. The 6.1-in long HeRep Mk IV count rate was 108.5 ± 2.0% and 113.8 ± 1.2% of the count rate of the 10-atm <sup>3</sup>He detector for bare <sup>252</sup>Cf, bare detector and moderated <sup>252</sup>Cf, moderated detector, respectively. The gamma-ray rejection ratio was determined for <sup>137</sup>Cs at a dose rate of 50 mR/hr. The gamma-ray rejection ratio was 1:1.5×10<sup>8</sup> and 1:4.6×10<sup>8</sup> for the 3.1-in long and 6.1-in long HeRep Mk IV, respectively. The HeRep Mk IVs exhibit a 116% (3.1-in long) and 33% (6.1-in long) improvement in intrinsic detection efficiency over the 0.75-in diameter by 4.5-in long HeRep Mk III for moderated <sup>252</sup>Cf at 25 cm.


nuclear science symposium and medical imaging conference | 2016

Improved low power, modular thermal neutron counter based on microstructured semiconductor neutron detectors (MSND)

Ryan G. Fronk; Steven L. Bellinger; Luke C. Henson; David E. Huddleston; Taylor R. Ochs; Timothy J. Sobering; Douglas S. McGregor

A modular, mass-producible, low-power, compact thermal-neutron counter has been developed to meet the needs for modern detector instruments and to compete with aging 3He-based counter systems. The Domino™ V5.4 neutron detector package is populated with four 1-cm2 active-area microstructured semiconductor neutron detectors (MSNDs). The detectors are calibrated to an intrinsic thermal neutron detection efficiency of 30% over its 4 cm2 active area. A gamma-ray rejection ratio of at least 1:10”8 is achieved at this calibration level. Total device dimensions measure 2.5-cm wide by 3.8-cm tall and 0.47-cm thick, weighing 9.5 g. Individual Dominoes™ can be tiled together into strings and then arrayed laterally to form large-area instruments. In this form, the small sensor can populate instruments up to 1 m2, with a cost that is comparable to a similar 3He-based array. The addition of I2C-based bias and threshold controllers reduces sensor cost and complexity over the previously-reported Domino™ versions (V3.0 and V4.0) and allows for user-end calibrations and modifications. Furthermore, the Domino™ has realized 10× reduced power consumption over previous versions, to nearly 90μW at 3.3 volts, while also reducing sensitivity to thermal- and capacitance-induced noise from the MSNDs, making the Domino™ an ideal candidate for 3He replacement and implementation in low-power, portable neutron-detector instruments.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2009

Design and operation of a 2-D thin-film semiconductor neutron detector array for use as a beamport monitor

Troy Unruh; Steven L. Bellinger; David E. Huddleston; W.J. McNeil; E. Patterson; Timothy J. Sobering; Douglas S. McGregor


Radiation Physics and Chemistry | 2015

Development of compact high efficiency microstructured semiconductor neutron detectors

Douglas S. McGregor; Steven L. Bellinger; Ryan G. Fronk; Luke C. Henson; David E. Huddleston; Taylor R. Ochs; J.K. Shultis; Timothy J. Sobering; R.D. Taylor


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2015

High-efficiency microstructured semiconductor neutron detectors for direct 3He replacement

Ryan G. Fronk; Steven L. Bellinger; Luke C. Henson; David E. Huddleston; Taylor R. Ochs; Timothy J. Sobering; Douglas S. McGregor


nuclear science symposium and medical imaging conference | 2015

Advancements in microstructured semiconductor neutron detector (MSND)-based instruments

Ryan G. Fronk; Steven L. Bellinger; Luke C. Henson; David E. Huddleston; Taylor R. Ochs; Michael A. Reichenberger; Cody J. Rietcheck; Colten T. Smith; Timothy J. Sobering; J. Kenneth Shultis; Douglas S. McGregor

Collaboration


Dive into the David E. Huddleston's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

R.D. Taylor

Kansas State University

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge