Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where David Fish is active.

Publication


Featured researches published by David Fish.


American Journal of Roentgenology | 2011

Preoperative Sentinel Node Identification With Ultrasound Using Microbubbles in Patients With Breast Cancer

Ali Sever; Philippa Mills; Sue Jones; Karina Cox; Jennifer Weeks; David Fish; Peter Jones

OBJECTIVE Sentinel lymph node (SLN) biopsy is the standard procedure for axillary staging in early breast cancer. Lymphatic imaging after peritumoral microbubble injection has been described in animal models. The aim of this study was to identify and localize SLNs preoperatively by contrast-enhanced sonography after intradermal injection of microbubbles in patients with breast cancer. SUBJECTS AND METHODS Eighty consecutive consenting patients with primary breast cancer were recruited. Patients received a periareolar intradermal injection of microbubble contrast agent. Breast lymphatics were visualized by sonography and followed to the axilla to identify SLNs. A guidewire was deployed to localize the SLN. The next day, patients underwent standard tumor excision and SLN biopsy. RESULTS In 71 (89%) of the 80 patients, SLNs were identified and guidewires were inserted. In these patients, operative findings using conventional radioisotope and blue dye techniques confirmed that the wired nodes were SLNs. Fourteen patients were found to have metastases in SLNs. In these patients, the SLNs were identified correctly and were localized with guidewires before surgery. CONCLUSION SLNs may be identified and localized before surgery using contrast-enhanced sonography after injection of microbubbles.


American Journal of Roentgenology | 2012

Preoperative needle biopsy of sentinel lymph nodes using intradermal microbubbles and contrast-enhanced ultrasound in patients with breast cancer.

Ali Sever; Philippa Mills; Jennifer Weeks; Sue Jones; David Fish; Peter Jones; Willem P. Th. M. Mali

OBJECTIVE The purpose of this study was to assess whether sentinel lymph nodes (SLNs) that undergo targeted needle biopsy after identification by contrast-enhanced ultrasound (CEUS) using intradermally injected microbubbles results in more node-positive breast cancer patients being diagnosed preoperatively. Furthermore, we sought to determine whether the addition of CEUS to gray-scale sonography of the axilla reduces the number of patients having axillary lymph node (ALN) dissection as a second procedure. SUBJECTS AND METHODS Intradermal microbubble injection was performed in 136 breast cancer patients who had no abnormal ALNs on routine gray-scale axillary sonography. When an enhancing ALN was visualized, percutaneous sonography-guided fine-needle aspiration cytology or core needle biopsy was performed. Depending on the biopsy results, patients underwent SLN biopsy or ALN dissection. If the putative SLN biopsy was positive or a biopsy tract was seen in the excised SLN, the procedure was defined as successful. RESULTS SLNs were identified and biopsied in 126 of the 136 cases (93%). Seventeen patients had positive sonography-guided biopsy results (13%) and were treated with immediate ALN dissection. In seven patients, the biopsied node was the only positive node. The remaining 109 patients underwent SLN biopsy. In nine cases (8%), a positive lymph node was identified. Four of these false-negative cases had only micrometastases. CONCLUSION SLNs can be identified and biopsied using CEUS to increase the accuracy of preoperative axillary staging. If the needle biopsy result is negative, conventional SLN biopsy is indicated.


Breast Journal | 2010

Axillary ultrasound assessment in primary breast cancer: an audit of 653 cases.

Pippa Mills; Ali Sever; Jenny Weeks; David Fish; S. Jones; Peter Jones

Abstract:  Axillary lymph node status is an important factor in determining the prognosis and treatment in patients with invasive breast cancer. The introduction of the sentinel lymph node biopsy technique in the axilla has significantly reduced the number of patients requiring an axillary clearance procedure. However, a proportion of patients will be found to have axillary metastases after a sentinel node biopsy and will then require a second axillary surgical procedure. A retrospective audit of 653 consecutive patients presenting with invasive breast cancer showed a preoperative diagnosis rate of axillary disease of 23% using axillary ultrasound and fine‐needle aspiration (FNA) together. We performed 232 axillary FNAs to diagnose 150 positive axillae. This avoided the need for a second operation in 150 women. The negative predictive value for axillary metastases using this technique was 79%. Overall accuracy was 84%.


Journal of Ultrasound in Medicine | 2010

Dynamic Visualization of Lymphatic Channels and Sentinel Lymph Nodes Using Intradermal Microbubbles and Contrast-Enhanced Ultrasound in a Swine Model and Patients With Breast Cancer

Ali Sever; Anne Broillet; Michel Schneider; Karina Cox; Sue Jones; Jenny Weeks; Pippa Mills; David Fish; Peter Jones

Objective. Sentinel lymph node (SLN) identification using intradermal micro‐bubbles and contrast‐enhanced ultrasound (CEUS) has been recently reported in swine models and patients with breast cancer. The objective of this study was to investigate the dynamics of intradermally administered microbubbles as they travel to draining SLNs in pigs. We also performed a detailed study of the passage of microbubbles through breast lymphatic channels in a small group of patients with breast cancer. Methods. Nine anesthetized healthy pigs were used for the study, and 5 female patients with primary breast cancer were recruited. Pigs received intradermal injections of a microbubble contrast agent in several territories to access lymphatic drainage to regional lymph nodes. Patients had periareolar intradermal injection of the microbubble contrast agent. Ultrasound examination was performed in the real‐time contrast pulse sequencing mode with a commercial scanner. Results. Sentinel lymph nodes were identified rapidly (<1 minute) and consistently in pigs. Intradermal microbubble injection and CEUS were found to have perfect concordance with the Evans blue dye method in locating swine SLNs. In all 5 patients with breast cancer, the microbubble contrast agent entered breast lymphatic channels and traveled to draining ipsilateral axillary SLNs within 3 minutes. Conclusions. Intradermally injected microbubbles traverse readily though lymphatic channels in pigs and human breast tissue. The ability to rapidly identify SLNs in the diagnostic period would enable targeted biopsy and may facilitate preoperative axillary staging in patients with early breast cancer.


European Radiology | 2012

Percutaneous removal of sentinel lymph nodes in a swine model using a breast lesion excision system and contrast-enhanced ultrasound

Ali Sever; Philippa Mills; Jean-Marc Hyvelin; Jennifer Weeks; Hatice Gümüş; David Fish; Willem P. Th. M. Mali; Sue Jones; Peter Jones; Haresh Devalia

AbstractObjectivesTo investigate the feasibility of percutaneous removal of the entire sentinel lymph node (SLN) in an animal model using a breast lesion excision system after identifying these nodes using contrast-enhanced ultrasound (CEUS) and intradermal microbubbles.MethodsAnimal studies approval was obtained. SLNs were identified using CEUS and intradermal injection of microbubbles in two young pigs. Microbubbles were mixed with blue dye and injected around the mammary papillae to access lymphatic drainage to the superficial inguinal lymph nodes. When enhancing nodes were identified, the breast lesion excision system (BLES) was used to remove these nodes percutaneously. Both animals then underwent surgical lymph node dissection. Histopathological examination of all the samples was performed.ResultsRemoval of the entire SLN was successful in three groins in the pigs. All three nodes were stained with blue dye. No other stained nodes were observed in the node dissection specimens. The nodal architecture of removed lymph nodes was well preserved on microscopy. There were no signs of excess trauma within the biopsy bed.ConclusionThe results obtained from the swine model demonstrated that it is feasible to remove the entire SLN percutaneously under the guidance of CEUS and microbubbles.Key Points• Intradermal injection of microbubbles and CEUS can identify sentinel lymph nodes • Ultrasound could then guide percutaneous removal of intact and complete SLNs • We have shown this was feasible in pigs but not yet in humans • This technique may eventually have the potential to reduce futile SLN biopsies.


Diagnostic and interventional radiology | 2012

Factors that impact the upgrading of atypical ductal hyperplasia.

Hatice Gümüş; Philippa Mills; Metehan Gümüş; David Fish; Sue Jones; Peter Jones; Haresh Devalia; Ali Sever

PURPOSE The purpose of this study was to identify the factors that may have an impact on upgrading atypical ductal hyperplasia (ADH) lesions to malignancy. MATERIALS AND METHODS Between February 1999 and December 2010, the records of 150 ADH lesions that had been biopsied were retrospectively reviewed. The biopsy types included 11-gauge stereotactic vacuum-assisted biopsy (SVAB) (n=102) and ultrasonography (US)-guided 14-gauge automated biopsy (n=48). The patients were divided into two groups: those who had cancer in the final pathology and those who did not. Variables associated with underestimation of ADH lesions were compared between the groups. RESULTS The underestimation rates according to the biopsy types were 41.7% (20/48) for the US-guided 14-gauge automated biopsy and 20.6% (21/102) for the 11-gauge SVAB (P = 0.007). The rate of underestimation was significantly higher in lesions greater than 7 mm than it was in smaller lesions, with both US-guided 14-gauge automated biopsy and 11-gauge SVAB (P = 0.024 and P = 0.042, respectively). The rate of underestimation was significantly higher with the 11-gauge SVAB (P = 0.025) in lesions that were suspicious (R4) and highly suggestive of malignancy (R5) than in those that were probably benign (R3). CONCLUSION The underestimation rate in ADH lesions was significantly higher with US-guided 14-gauge automated biopsy compared to the 11-gauge SVAB. The underestimation rate was also significantly higher in lesions greater than 7 mm regardless of the biopsy type, and in lesions biopsied using SVAB that were regarded as suspicious (R4) or highly suggestive of malignancy (R5) on imaging.


Diagnostic and interventional radiology | 2011

Causes of failure in removing calcium in microcalcification-only lesions using 11-gauge stereotactic vacuum-assisted breast biopsy.

Hatice Gümüş; Metehan Gümüş; Haresh Devalia; Philippa Mills; David Fish; Peter Jones; Aşur Uyar; Ali Sever

PURPOSE The aim of this study was to determine the causes and rate of failure in removing calcification in microcalcification-only lesions using 11-gauge stereotactic vacuum-assisted breast biopsy. MATERIALS AND METHODS In total, 1365 microcalcification-only lesions were included in this study. The breast biopsy database was reviewed retrospectively. The biopsies were divided into two groups based on whether the specimen X-ray showed calcium within the cores. Breast composition, lesion size, calcification distribution, density on mammography, and the number of specimens were compared between the two groups. RESULTS In 11 (0.8%) biopsies, no calcium in the specimen radiography could be identified. Re-biopsy was performed in five cases. The initial biopsy result was unchanged at the second biopsy in three cases containing calcium, while in the other two cases, a benign biopsy result was upgraded to atypical ductal hyperplasia and ductal carcinoma in situ, respectively. In six cases, the biopsy was not repeated despite the absence of calcium in the specimen X-ray. In three of these cases, calcifications were reported histopathologically and deemed to be too small to be identified on specimen X-ray. In two of six patients, sufficient information was found in the cores without microcalcification to indicate the need for surgery. One patient refused re-biopsy. A statistically significant higher failure rate was observed in low-density calcification compared with intermediate or high-density calcification on mammography. CONCLUSION The failure to retrieve microcalcification is uncommon when an 11-gauge vacuum-assisted breast biopsy is used. Low-density calcifications have a higher rate of failure. In cases in which no calcium is observed in specimen radiography, repeated biopsy is recommended.


Wiener Klinische Wochenschrift | 2007

A rare cause of breast mass that mimics carcinoma: Foreign body reaction to amorphous surgical material.

Burhan Yazici; Ali Sever; Philippa Mills; David Fish; Sue Jones; Peter Jones

ZusammenfassungEine durch Fremdkörper ausgelöste granulomatöse Reaktion auf chirurgisches Material ist eine sehr seltene Läsion, kann sich aber in der Brust wie ein Karzinom darstellen. Bisher berichtete chirurgische Fremdmateralien sind Nahtmaterial, Silikon, Paraffin, Streupuder und Karbonpartikel, die zur Lokalisation nicht palpabler Brustläsionen verwendet werden. Unserem Wissen nach ist eine Fremdkörperreaktion auf Gazeschwamm bisher noch nicht berichtet worden. Die vorliegende Arbeit berichtet über eine 58-jährige Frau, die einen wachsenden Tumor hatte, der sich wie ein Mammakarzinom darstellte. Der Tumor war die Folge einer Fremdkörperreaktion auf Gazeschwamm. Zusätzlich wird eine Übersicht über die relevante Literatur gegeben.SummaryA breast mass caused by foreign body type granulomatous reaction to surgical material is a very rare lesion and may mimic carcinoma. Reported foreign materials have included suture materials, silicone, paraffin, gunpowder and carbon particles used for localization of a nonpalpable breast lesions. To our knowledge, a foreign body reaction to gauze sponge has not been reported previously. A 58-year-old woman who had an enlarging mass that mimicked breast carcinoma, due to foreign body reaction to gauze sponge is presented here, and relevant literature is reviewed.


Diagnostic and Interventional Radiology | 2015

Predictive factors for invasive cancer in surgical specimens following an initial diagnosis of ductal carcinoma in situ after stereotactic vacuum-assisted breast biopsy in microcalcification-only lesions

Hatice Gümüş; Philippa Mills; David Fish; Metehan Gümüş; Karina Cox; Haresh Devalia; Sue Jones; Peter Jones; Ali Sever

PURPOSE The aim of this study was to determine the incidence of invasive breast carcinoma in patients with preoperative diagnosis of ductal carcinoma in situ (DCIS) by stereotactic vacuum-assisted biopsy (SVAB) performed for microcalcification-only lesions, and to identify the predictive factors of invasion. METHODS From 2000 to 2010, the records of 353 DCIS patients presenting with microcalcification-only lesions who underwent SVAB were retrospectively reviewed. The mammographic size of microcalcification cluster, presence of microinvasion within the cores, the total number of calcium specks, and the number of calcium specks within the retrieved core biopsy specimen were recorded. Patients were grouped as those with or without invasion in the final pathologic report, and variables were compared between the two groups. RESULTS The median age was 58 years (range, 34-88 years). At histopathologic examination of the surgical specimen, 63 of 353 patients (17.8%) were found to have an invasive component, although SVAB cores had only shown DCIS preoperatively. The rate of underestimation was significantly higher in patients with microcalcification covering an area of 40 mm or more, in the presence of microinvasion at biopsy, and in cases where less than 40% of the calcium specks were removed from the lesion. CONCLUSION Invasion might be underestimated in DCIS cases diagnosed with SVAB performed for microcalcification-only lesions, especially when the mammographic size of calcification is equal to or more than 40 mm or if microinvasion is found within the biopsy specimen and less than 40% of the calcifications are removed. At least 40% of microcalcification specks should be removed from the lesion to decrease the rate of underestimation with SVAB.


Breast Journal | 2013

Breast microcalcification: diagnostic value of calcified and non-calcified cores on specimen radiographs.

Hatice Gümüş; Pippa Mills; David Fish; Metehan Gümüş; Haresh Devalia; Sue Jones; Ali Sever

To determine if the specimen without calcification, as depicted on specimen radiography, made any contribution to the final histopathological diagnosis in comparison to the specimen with calcification. The records of 1312 stereotactic vacuum‐assisted biopsies for breast microcalcifications between February 2000 and December 2010 were reviewed retrospectively. Following specimen x‐ray the biopsy tissues with and without microcalcifications were sent in two separate pots (pot 1 and pot 2 respectively). The number of cores in each pot and the number of calcium specks within the cores were recorded. In 1135 of the 1312 (86%) cases the histopathological findings were similar for pot 1 and pot 2. In 165 cases (13%) the diagnosis was made solely on pot 1 while cores in pot 2 did not reveal any additional pathology. In 12 biopsies (1%) the significant pathology was only present in the specimen without any calcification. For “microcalcification only” breast lesions the specimen containing calcium will yield a correct diagnosis in 99% of cases. Cores containing no calcification rarely contribute to the diagnosis on their own, but in 87% of cases an accurate diagnosis would still have been made even if the targeted calcification had been missed.

Collaboration


Dive into the David Fish's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Karina Cox

The Royal Marsden NHS Foundation Trust

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jenny Weeks

Maidstone and Tunbridge Wells NHS Trust

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge