Journal of Vacuum Science and Technology | 1998
David H. Holkeboer; T. L. Karandy; F. C. Currier; Louis C. Frees; Robert E. Ellefson
Monitoring of gas composition for processes in the mTorr range is not possible with a conventional residual gas analyzer (RGA) unless a pressure reduction pumping system is used. A miniature sensor, having dimensions compatible with the mean-free path of gas molecules can operate directly at mTorr pressures while being less expensive and more compact than a conventional apparatus. This article describes a quadrupole RGA which is scaled down by a factor of 7 to operate at pressures up to 10 mTorr. This sensor requires different construction methods and drive electronics than a traditional RGA. A unique ion source with high output has been developed. The small sensor has resolution characteristics very similar to standard size models but sensitivity is reduced in proportion to the ratio of cross-sectional area for each quadrupole r0. Response is linear to the mTorr range and a correction method for gas scattering, based on pressure measured by a total pressure gauge included in the ion source design, extend...
Journal of Vacuum Science and Technology | 1993
James A. Basford; Mark D. Boeckmann; Robert E. Ellefson; Albert R. Filippelli; David H. Holkeboer; Laslo Lieszkovsky; Catherine M. Stupak
This Recommended Practice addresses issues involved in the use of partial pressure analyzers (PPAs) for quantitative analysis and describes recommended apparatus and procedures for determining resolution and sensitivity of a PPA so that the instrument can be used quantitatively for partial pressure, partial flow and gas composition analysis. This updates previous material in the AVS Standard 2.3-1972 (tentative) by including reference to current pressure transfer standards and computer controlled PPAs. This document presents an introduction to PPAs and how they work, definitions pertinent to the use of PPAs, equipment needed for calibration, instrument setup prior to calibration and the measurement of sensitivity and linearity by various methods. Four methods of calibration of a PPA are described as follows: (1) the direct comparison of the PPA output with a transfer standard pressure gauge, (2) the indirect comparison of PPA readings with readings of a transfer standard pressure gauge separated by a flow...
Archive | 1997
David H. Holkeboer
Archive | 1985
David H. Holkeboer
Archive | 1998
David H. Holkeboer
Archive | 1997
David H. Holkeboer; Robert E. Ellefson
Archive | 1997
David H. Holkeboer; Louis C. Frees
Archive | 1998
David H. Holkeboer
Journal of Vacuum Science and Technology | 1993
James A. Basford; M. D. Boeckmann; Robert E. Ellefson; Albert R. Filippelli; David H. Holkeboer; L. Lieszkovszky; C. M. Stupak
Archive | 1998
Robert E. Ellefson; David H. Holkeboer; エイチ. ホルクボアー デイビッド; イー. エレフソン ロバート