David Wallace-Bradley
University of Houston
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by David Wallace-Bradley.
Circulation-cardiovascular Imaging | 2010
Troels Thim; Mette Kallestrup Hagensen; David Wallace-Bradley; Juan F. Granada; Greg L. Kaluza; Ludovic Drouet; William P. Paaske; Hans Erik Bøtker; Erling Falk
Background—Intravascular ultrasound–derived virtual histology (VH IVUS) is used increasingly in clinical research to assess composition and vulnerability of coronary atherosclerotic lesions. However, the ability of VH IVUS to quantify individual plaque components, in particular the size of the destabilizing necrotic core, has never been validated. We tested for correlation between VH IVUS necrotic core size and necrotic core size by histology in porcine coronary arteries with human-like coronary disease. Methods and Results—In adult atherosclerosis-prone minipigs, 18 advanced coronary lesions were assessed by VH IVUS in vivo followed by postmortem microscopic examination (histology). We found no correlation between the size of the necrotic core determined by VH IVUS and histology. VH IVUS displayed necrotic cores in lesions lacking cores by histology. Conclusions—We found no correlation between necrotic core size determined by VH IVUS and real histology, questioning the ability of VH IVUS to detect rupture-prone plaques, so-called thin-cap fibroatheromas.
Circulation-cardiovascular Imaging | 2010
Troels Thim; Mette Kallestrup Hagensen; David Wallace-Bradley; Juan F. Granada; Greg L. Kaluza; Ludovic Drouet; William P. Paaske; Hans Erik Bøtker; Erling Falk
Background—Intravascular ultrasound–derived virtual histology (VH IVUS) is used increasingly in clinical research to assess composition and vulnerability of coronary atherosclerotic lesions. However, the ability of VH IVUS to quantify individual plaque components, in particular the size of the destabilizing necrotic core, has never been validated. We tested for correlation between VH IVUS necrotic core size and necrotic core size by histology in porcine coronary arteries with human-like coronary disease. Methods and Results—In adult atherosclerosis-prone minipigs, 18 advanced coronary lesions were assessed by VH IVUS in vivo followed by postmortem microscopic examination (histology). We found no correlation between the size of the necrotic core determined by VH IVUS and histology. VH IVUS displayed necrotic cores in lesions lacking cores by histology. Conclusions—We found no correlation between necrotic core size determined by VH IVUS and real histology, questioning the ability of VH IVUS to detect rupture-prone plaques, so-called thin-cap fibroatheromas.
Jacc-cardiovascular Imaging | 2010
Akira Murata; David Wallace-Bradley; Armando Tellez; Carlos L. Alviar; Michael S. Aboodi; Alexander Sheehy; Leslie Coleman; Laura Perkins; Gaku Nakazawa; Gary S. Mintz; Greg L. Kaluza; Renu Virmani; Juan F. Granada
OBJECTIVES This study aimed to evaluate the accuracy of optical coherence tomography (OCT) in analyzing the neointimal response to several drug-eluting stent (DES) types by comparing OCT images acquired in vivo with corresponding histological specimens using a nondiseased porcine injury model. BACKGROUND Optical coherence tomography is emerging as a promising endovascular imaging tool for the evaluation of neointimal response after DES implantation. METHODS A total of 84 stents were implanted-22 ML Vision (Abbott Vascular, Santa Clara, California), 22 Xience V (Abbott Vascular), 20 Endeavor (Medtronic, Minneapolis, Minnesota), and 20 Taxus Liberté (Boston Scientific, Natick, Massachusetts) stents-in normal porcine coronary arteries and were harvested at 28 (n=42) and 90 (n=42) days, with the different stent types equally distributed between the 2 follow-up periods. At termination, morphometric evaluation using OCT imaging was performed in all stented arteries. Histological morphometric analysis was performed and correlated with OCT. RESULTS A total of 622 OCT-histology matched frames acquired from all stent designs were analyzed. The luminal (13.7%) and stent (6.1%) areas were consistently larger by OCT compared with histology. The mean neointimal thickness was very similar between techniques (approximately 3.27% variation). There was a high correlation between OCT and histology for the evaluation of neointimal area (R2=0.804), luminal area (R2=0.825), and neointimal thickness (R2=0.789). Correlation for total stent area was poor (R2=0.352). Although the proportion of individual struts determined to be uncovered by OCT and histology was similar, there was significant variation in the estimation of strut coverage between OCT and histology when the neointimal thickness was between 20 and 80 microm. This variation converged for neointimal thicknesses between 80 and 100 microm. CONCLUSIONS Subtle differences in neointimal formation induced by current DES can be reproducibly analyzed in vivo by OCT. However, OCT measurement of stent area seems to have less correlation with histology.
Journal of the American College of Cardiology | 2009
Pawel Buszman; Piotr P. Buszman; R. Stefan Kiesz; Andrzej Bochenek; Blazej Trela; Magda Konkolewska; David Wallace-Bradley; Mirosław Wilczyński; Iwona Banasiewicz-Szkróbka; Ewa Peszek-Przybyła; Marek Król; Marek Kondys; Krzysztof Milewski; Szymon Wiernek; Marcin Dębiński; Aleksander Żurakowski; Jack L. Martin; Michal Tendera
OBJECTIVES The aim of the study was to evaluate early and late outcomes after percutaneous coronary intervention (PCI) of unprotected left main coronary artery disease (ULMCA) and to compare bare-metal stent (BMS) and drug-eluting stent (DES) subgroups. BACKGROUND PCI is an increasingly utilized method of revascularization in patients with ULMCA. METHODS This multicenter prospective registry included 252 patients after ULMCA stenting enrolled between March 1997 and February 2008. Non-ST-segment elevation acute coronary syndrome was diagnosed in 58% of patients; ST-segment elevation myocardial infarction cases were excluded. Drug-eluting stents were implanted in 36.2% of patients. RESULTS Major adverse cardiovascular and cerebral events (MACCE) occurred in 12 (4.8%) patients during the 30-day period, which included 4 (1.5%) deaths. After 12 months there were 17 (12.1%) angiographically confirmed cases of restenosis. During long-term follow-up (1 to 11 years, mean 3.8 years) there were 64 (25.4%) MACCE and 35 (13.9%) deaths. The 5- and 10-year survival rates were 78.1% and 68.9%, respectively. Despite differences in demographical and clinical data in favor of BMS patients, unmatched analysis showed a significantly lower MACCE rate in DES patients (25.9% vs. 14.9%, p = 0.039). This difference was strengthened after propensity score matching. The DES lowered both mortality and MACCE for distal ULMCA lesions when compared with BMS. Ejection fraction <50% was the only independent risk factor influencing long-term survival. CONCLUSIONS Stenting of ULMCA is feasible and offers good long-term outcome. Implantation of DES for ULMCA decreased the risk of long-term MACCE, and particularly improved survival in patients with distal ULMCA disease.
Arteriosclerosis, Thrombosis, and Vascular Biology | 2006
Juan F. Granada; David Wallace-Bradley; Htut K. Win; Carlos L. Alviar; Angela Builes; Eli I. Lev; Roberto Barrios; Daryl G. Schulz; Albert E. Raizner; Greg L. Kaluza
Objective—To determine the accuracy of detection of different tissue types of intravascular ultrasound–virtual histology (IVUS-VH) in a porcine model of complex coronary lesions. Methods and Results—Coronary lesions were induced by injecting liposomes containing human oxidized low-density lipoprotein into the adventitia of the arteries. IVUS-VH imaging was performed in vivo at 8.2±1.6 weeks after injection. A total of 60 vascular lesions were analyzed and compared with their correspondent IVUS-VH images. Correlation analysis was performed using linear regression models. Compared with histology, IVUS-VH correctly identified the presence of fibrous, fibro-fatty, and necrotic tissue in 58.33%, 38.33%, and 38.33% of lesions, respectively. The sensitivity of IVUS-VH for the detection of fibrous, fibro-fatty, and necrotic core tissue was 76.1%, 46%, and 41.1% respectively. A linear regression analysis performed for each individual plaque component did not show strong correlation that would allow significant prediction of individual values. Conclusions—In a porcine model of complex coronary lesions, IVUS-VH was not accurate in detecting the relative amount of specific plaque components within each individual corresponding histological specimen.
Circulation-cardiovascular Interventions | 2010
Juan F. Granada; Shigenobu Inami; Michael S. Aboodi; Armando Tellez; Krzysztof Milewski; David Wallace-Bradley; Sherry Parker; Steve Rowland; Gaku Nakazawa; Marc Vorpahl; Frank D. Kolodgie; Greg L. Kaluza; Martin B. Leon; Renu Virmani
Background—We aimed to demonstrate that, by separating endothelial progenitor cell capture from sirolimus delivery through the application of drug to the abluminal surface of the stent, the degree of endothelialization can be enhanced. Methods and Results—Stainless steel R Stents, with biodegradable SynBiosys polymer coating with sirolimus abluminally applied and surface modified with anti-CD34 antibody were prepared at 2 dosages (low-dose sirolimus [LD-Combo, 2.5 &mgr;g sirolimus/mm] and full-dose sirolimus [Combo, 5 &mgr;g sirolimus/mm). These Combo stents and the Cypher stent (10 &mgr;g sirolimus/mm) were deployed in 98 normal porcine arteries and harvested for pharmacokinetic analysis at 0.25, 1, 3, 7, 14, 28, and 35 days. The LD-Combo stents showed faster early release (50% total dose in 72 hours) than the Combo and Cypher. At 30 days, drug release was near complete with both Combo stents, whereas 20% of drug remained on the Cypher stents. To assess efficacy, a total of 50 stents (Xience V=8, Cypher=8, Genous bioengineered R stent=6, LD-Combo=14, and Combo=14) were implanted in 18 pigs for 14 and 28 days. Optical coherence tomography was performed, and stents were harvested for histology. At 28 days, there was less neointimal thickness with Combo (0.173±0.088 mm) compared with Cypher (0.358±0.225 mm), LD-Combo (0.316±0.228 mm), and Xience V (0.305±0.252 mm; P<0.00001). Immunohistochemical analysis of endothelialization showed that Genous bioengineered R stent had the highest degree of platelet endothelial cell adhesion molecule expression (87%) followed by the Combo (75%), LD-Combo (65%), and Cypher (58%). Conclusions—Both optical coherence tomography and histology demonstrate that anti-CD34 sirolimus-eluting stents promote endothelialization while reducing neointimal formation and inflammation.
Jacc-cardiovascular Imaging | 2011
Jung-Sun Kim; David Wallace-Bradley; Carlos L. Alviar; Gerard Conditt; Krzysztof Milewski; Maxwell Afari; Yanping Cheng; Catalina Gallego; Armando Tellez; Gregg W. Stone; Greg L. Kaluza; Juan F. Granada
OBJECTIVES We aimed to evaluate the correlation of angiographic late loss (LL) with the degree of in-stent neointimal proliferation assessed by optical coherence tomography (OCT) and histology. BACKGROUND Angiographic LL is the most common endpoint used in clinical trials for the evaluation of the efficacy of drug-eluting stents (DES). However, there are few data in regards to the accuracy of angiographic LL in the evaluation of DES displaying lower degrees of neointimal proliferation. METHODS A total of 49 stents (36 DES and 13 bare-metal stents) were deployed in coronary arteries of 23 domestic swine and followed up for 28 or 90 days, thus obtaining different degrees of neointimal proliferation. Each stent was divided into 8 to 9 segments along the longitudinal axis to match corresponding histological cross sections. Angiographic LL was calculated at each segment throughout the entire length of the stent and compared with in-stent neointimal thickness (NT) obtained by OCT and histology. RESULTS A total of 382 angiographic segments were suitable for matched comparison with both OCT and histological findings. The mean LL at follow-up was 0.60 ± 0.57 mm (range: -0.46 to 2.3 mm) for all segments. Approximately 13.9% of stent segments had a LL between -0.5 and 0 mm, and 22.5% had a LL greater than 1.0 mm. The correlation between OCT and histology for the evaluation of NT was adequate regardless the level of angiographic LL. In addition, overall correlations between angiographic LL and NT by OCT or histology were adequate (R = 0.77 and 0.63, respectively). However, angiographic LL showed a poor correlation with NT by OCT or histology at a value <0.55 mm (R = 0.38 and 0.15, respectively). CONCLUSIONS Angiographic LL below a threshold value of 0.55 mm correlates poorly with NT obtained by OCT and histology. These results suggest a cautious interpretation is needed to evaluate angiographic endpoints in DES trials in which LL values below this threshold are reported.
Eurointervention | 2010
Carlos L. Alviar; Armando Tellez; David Wallace-Bradley; Gabriel Lopez-Berestein; Angela Sanguino; Daryl Schulz; Angela Builes; Christie M. Ballantyne; Chao Yuh Yang; Greg L. Kaluza; Juan F. Granada
AIMS There is little in vivo data in regards to the impact of adventitial neovascularisation on vascular remodelling and plaque composition. Using a porcine model of coronary atherosclerosis, we aimed to determine the impact of adventitial neovascularisation on plaque composition and vascular remodelling evaluated by IVUS. METHODS AND RESULTS Coronary atherosclerosis was induced by adventitial delivery of lipids and a high cholesterol diet. At termination all vessels were analysed using IVUS to determine the degree of remodelling of each individual segment containing atherosclerotic lesions. Then, each segment was correlated with its correspondent histological frame for plaque composition and neovessel density. A total of 57 atherosclerotic lesions at different stages of development were analysed. The total neovessel count (TNC) correlated to the degree of plaque burden (15.6+/-7.2 TNC in 60% stenosis, p<0.01) and to the amount of intra-plaque collagen (32.4+/-14.1%, lower TNC tertile versus 47.5+/-8.9% upper TNC tertile, p< 0.01). The amount of intra-plaque SMC content inversely correlated with the TNC (49.7+/-18.9% versus 36.4+/-14.4%, lower versus upper tertiles, p<0.05). Plaques with the highest TNC showed higher remodelling indexes by IVUS (0.89+/-0.32 in lower TNC tertile versus 1.36+/-0.73 in upper TNC tertile, p<0.05) and higher macrophage cell content (161.42+/-157.6 in lower TNC tertile versus 340.6+/-127.2 in upper TNC tertile, p<0.05) compared to non-remodelled segments. CONCLUSIONS Adventitial neovascularisation is more prominent in positively remodelled segments and appears to be associated to SMC loss, increase collagen deposition and localised macrophage infiltration.
Cell Transplantation | 2013
Yanping Cheng; Geng-Hua Yi; Gerard Conditt; Alexander Sheehy; Frank D. Kolodgie; Armando Tellez; Igor Polyakov; Anguo Gu; Michael S. Aboodi; David Wallace-Bradley; Michael D. Schuster; Timothy P. Martens; Silviu Itescu; Greg L. Kaluza; Shubhayu Basu; Renu Virmani; Juan F. Granada; Warren Sherman
The administration of bone marrow-derived stem cells may provide a new treatment option for patients with heart failure. Transcatheter cell injection may require multi-imaging modalities to optimize delivery. This study sought to evaluate whether endomyocardial injection of mesenchymal precursor cells (MPCs) could be guided by real-time 3D echocardiography (RT3DE) in treating chronic, postinfarction (MI) left ventricular (LV) dysfunction in sheep. Four weeks after induction of an anterior wall myocardial infarction in 39 sheep, allogeneic MPCs in doses of either 25 × 106 (n = 10), 75 × 106 (n = 9), or 225 × 106 (n = 10) cells or nonconditioned control media (n = 10) were administered intramyocardially into infarct and border zone areas using a catheter designed for combined fluoroscopic and RT3DE-guided injections. LV function was assessed before and after injection. Infarct dimension and vascular density were evaluated histologically. RT3DE-guided injection procedures were safe. Compared to controls, the highest dose MPC treatment led to increments in ejection fraction (3±3% in 225M MPCs vs. −5±4% in the control group, p < 0.01) and wall thickening in both infarct (4±4% in 225M MPCs vs. −3±6% in the control group, p = 0.02) and border zones (4±6% in 225M MPCs vs. −8±9% in the control group, p = 0.01). Histology analysis demonstrated significantly higher arteriole density in the infarct and border zones in the highest dose MPC-treated animals compared to the lower dose or control groups. Endomyocardial implantation of MPCs under RT3DE guidance was safe and without observed logistical obstacles. Significant increases in LV performance (ejection fraction and wall thickening) and neovascularization resulted from this technique, and so this technique has important implications for treating patients with postischemic LV dysfunction.
Circulation-cardiovascular Imaging | 2010
Troels Thim; Mette Kallestrup Hagensen; David Wallace-Bradley; Juan F. Granada; Greg L. Kaluza; Ludovic Drouet; William P. Paaske; Hans Erik Bøtker; Erling Falk
We appreciate this opportunity to respond to the comments provided by Drs Gregg Stone and Gary Mintz. They question the conclusion of our study, in which no correlation was found between the size of the necrotic core determined by virtual histology intravascular ultrasound (VH IVUS) and real histology in a porcine model of coronary artery disease.1 First, Drs Stone and Mintz stress the importance of reliable alignment and matching of corresponding images and state that “ … it is inappropriate to align a given histological section to an IVUS frame and expect high correlation in quantification of individual tissue components.” We acknowledge the potential limitations of such alignment, but we do not agree that the method is inappropriate, because this approach forms the general base for validation of VH IVUS for quantitative tissue mapping.2,3 Second, Drs Stone and Mintz argue that our …