Dawn R. Rabbach
Promega
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Dawn R. Rabbach.
Journal of Forensic Sciences | 2002
Benjamin E. Krenke; Allan Tereba; Stacey J. Anderson; Eric Buel; Sherry Culhane; Carla J. Finis; Christine S. Tomsey; Jeffrey M. Zachetti; Arni Masibay; Dawn R. Rabbach; Elizabeth Amiott; Cynthia J. Sprecher
STR multiplexes have been indispensable for the efficient genotyping of forensic samples. The PowerPlex 16 System contains the coreCODIS loci, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, CSF1PO, FGA, THOI, TPOX, vWA, the sex determinant locus, amelogenin, and two pentanucleotide STR loci, Penta D and Penta E. This multiplex satisfies the locus requirements for most national databases and is the most efficient currently available system due to its single PCR amplification. To provide the groundwork for judicial acceptance, including the publication of primer sequences, and to evaluate laboratory-to-laboratory variation, a developmental validation for casework on this commercially available system was performed in 24 laboratories and produced the following conclusions. Amplification was reliable on a variety of thermal cyclers and product could be analyzed on either an ABI PRISM 310 Genetic Analyzer or an ABI PRISM 377 DNA Sequencer. Genotyping using single source samples was consistent between 0.25 and 2 ng of input DNA template with a few laboratories obtaining complete genotypes at 0.0625 ng. However, heterozygote allele imbalance (<60% peak height balance) caused by stochastic effects was observed at a rate of 13% with 0.125 ng DNA and 22% at 0.0625 ng DNA. Mixture analyses were done using a total of 1 ng of DNA template. Most alleles were detected in mixtures of 4 to 1 and some minor alleles were detected in mixtures of 19 to 1. Optimum amplification cycle number was dependent on the sensitivity of the detection instrument used and could also be adjusted to accommodate larger amounts of DNA on solid supports such as FTA paper. Reaction conditions including volume, annealing temperature, and concentrations of primer, AmpliTaq Gold, and magnesium were shown to be optimal yet robust enough to withstand moderate variations without affecting genotype analysis. Environmental, matrix and standard source analyses revealed an ability to obtain complete genotypes in all sample types except those exposed to 80 degrees C for 12-48 days. Finally, comparison of genotype results from the PowerPlex 16 System with other commercially available systems on non-probative reference and forensic samples showed consistent results.
Forensic Science International-genetics | 2011
Carolyn R. Hill; David L. Duewer; Margaret C. Kline; Cynthia J. Sprecher; Robert S. McLaren; Dawn R. Rabbach; Benjamin E. Krenke; Martin G. Ensenberger; Patricia M. Fulmer; Douglas R. Storts; John M. Butler
The PowerPlex(®) ESX 17 and ESI 17 Systems for short tandem repeat (STR) amplification were developed by the Promega Corporation to meet the European Network of Forensic Science Institutes (ENFSI) and the European DNA Profiling (EDNAP) Group recommendations for increasing the number of STR loci included in the European Standard Set (ESS). The PowerPlex ESX 17 and ESI 17 Systems utilize different PCR primer combinations to co-amplify the following 17 loci: D1S1656, D2S441, D2S1338, D3S1358, D8S1179, D10S1248, D12S391, D16S539, D18S51, D19S433, D21S11, D22S1045, FGA, TH01, vWA, SE33, and the sex-typing locus amelogenin. A total of 1443 U.S. population samples were evaluated with pre-commercialization versions of both kits. Stutter and heterozygote peak height ratios have been used to characterize kit performance. Typing results have been used to estimate the match probabilities provided by the chosen loci as well as in concordance studies. Full concordance between the typing results for the two kits was observed in 99.994% (49,055 out of 49,062) STR allele calls compared. All genotyping discrepancies were confirmed by DNA sequence analysis. As a result of these comparisons, a second forward primer for the D22S1045 locus has been added to the PowerPlex ESX 17 System to address a primer binding site mutation and the D1S1656 locus reverse primer in the PowerPlex ESI 17 System was modified to eliminate an amplification-efficiency reducing primer dimer.
Journal of Forensic Sciences | 1998
Ann M. Lins; Katherine A. Micka; Cynthia J. Sprecher; Jennifer A. Taylor; Jeffery W. Bacher; Dawn R. Rabbach; Robert Bever; Steven D. Creacy; James W. Schumm
Amplification of short tandem repeat (STR) loci has become a useful tool for human identification applications. To improve throughput and efficiency for such uses, the polymorphic STR loci CSF1PO, TPOX, TH01, vWA, D16S539, D7S820, D13S317, D5S818, F13A01, FESFPS, F13B, and LPL have been evaluated, developed, and configured into fluorescently labeled multiplex systems. Eight of these STR loci were combined to generate the PowerPlex System, a two-color multiplex system that supports rapid, accurate, reliable analysis and designation of alleles. The remaining four loci comprise the FFFL System, a one-color multiplex system. The PowerPlex System may be evaluated alternatively as two one-color, four-locus multiplex systems, CTTv Multiplex and GammaSTR Multiplex. The products of multiplex amplification may be analyzed with a variety of fluorescence detection instruments. Determination of genotypes of over 200 individuals from each of three different population/ethnic groups revealed independence of inheritance of the loci and allowed calculation of matching probability, typical paternity index, and power of exclusion for each multiplex.
Forensic Science International-genetics | 2013
Jonelle M. Thompson; Margaret M. Ewing; William E. Frank; Jill J. Pogemiller; Craig Nolde; D. Jody Koehler; Alyssandra M. Shaffer; Dawn R. Rabbach; Patricia M. Fulmer; Cynthia J. Sprecher; Douglas R. Storts
The PowerPlex® Y23 System combines the seventeen Y-STR loci in current commercially available Y-STR kits (DYS19, DYS385a/b, DYS389I/II, DYS390, DYS391, DYS392, DYS393, DYS437, DYS438, DYS439, DYS448, DYS456, DYS458, DYS635, and Y-GATA-H4) with six new highly discriminating Y-STR loci (DYS481, DYS533, DYS549, DYS570, DYS576, and DYS643). These six new loci have higher gene diversities than most of the loci in other commercial Y-STR analysis kits, allowing for further distinction between unrelated male individuals. In addition, the inclusion of two rapidly mutating Y-STR loci may allow for the discrimination of related individuals. The PowerPlex® Y23 System is designed to amplify DNA from purified extracts as well as direct amplification from substrates used to collect database samples (e.g. swabs and storage cards). Validation of the PowerPlex® Y23 System includes all of the studies required by the FBI and SWGDAM. The results demonstrate that the PowerPlex® Y23 System is a robust and reliable amplification kit capable of overcoming high concentrations of commonly encountered inhibitors such as hematin, humic acid, and tannic acid. Full profiles are consistently detected with 62.5 pg of male DNA, even in the presence of excessive amounts of female DNA, establishing the PowerPlex(®) Y23 System as a sensitive method for Y-STR testing. Complete Y-STR profiles are detected from mixed samples with 62.5 pg of male DNA in a background of 400 ng of female DNA or 125 pg of male DNA mixed with 3000 ng of female DNA.
Forensic Science International-genetics | 2013
Carey Davis; Jianye Ge; Cynthia J. Sprecher; Abirami Chidambaram; Jonelle M. Thompson; Margaret M. Ewing; Patricia M. Fulmer; Dawn R. Rabbach; Douglas R. Storts; Bruce Budowle
The Prototype PowerPlex(®) Y23 System (Promega Corporation, Madison, WI) is a polymerase chain reaction-based amplification kit that targets the 23 Y STR loci DYS19, DYS385a/b, DYS389I, DYS389II, DYS390, DYS391, DYS392, DYS393, DYS437, DYS438, DYS439, DYS448, DYS456, DYS458, DYS481, DYS533, DYS549, DYS570, DYS576, DYS635, DYS643, and Y-GATA-H4. A total of 951 samples from six populations were typed to evaluate the kit and examine concordance for 17 of the loci that are in common with those that can be typed using the AmpFlSTR(®) Yfiler™ kit (Life Technologies, Carlsbad, CA). A total of 16,167 loci were analyzed for each multiplex, and overall concordance was observed. Because of different kit designs, and although concordant for the genetic type, discordant calls can occur due to a deletion at the DYS448 locus. Users should take into consideration such nomenclature anomalies when comparing Y STR profiles. This new kit allows a large battery of Y STR loci to be analyzed using the same basic technologies already employed in forensic laboratories.
Journal of Forensic Sciences | 1999
Katherine A. Micka; Elizabeth Amiott; Tara L. Hockenberry; Cynthia J. Sprecher; Ann M. Lins; Dawn R. Rabbach; Jennifer A. Taylor; Jeffrey W. Bacher; Debra E. Glidewell; Sandra Gibson; Cecelia A. Crouse; James W. Schumm
The Gene Print PowerPlex 1.1/Amelogenin and FFFL Fluorescent STR Systems have been validated following the recommendations presented by the Technical Working Group on DNA Analysis Methods (TWGDAM). The PowerPlex 1.1/Amelogenin System supports simultaneous amplification of eight short tandem repeat loci and the Amelogenin gender identification marker. The loci D16S539, D7S820, D13S317, and D5S818 are labeled with fluorescein (FL) while the loci CSF1PO, TP0X, TH01, vWA and Amelogenin are labeled with carboxy-tetramethylrhodamine (TMR). The FFFL Multiplex System is composed of the loci F13A01, FESFPS, F13B, and LPL, each labeled with fluorescein. We have observed no overlap of alleles across loci labeled with an individual fluorescent dye. Samples of each system were amplified and labeled in a single reaction, separated by electrophoresis through a denaturing polyacrylamide gel, and amplified alleles detected using a Hitachi FMBIO Fluorescent Scanner. Alterations from the standard amplification protocols in cycle number and annealing temperature generally produced excellent results. In experiments testing sensitivity as little as 0.2 ng of DNA template could be detected. As expected, different body fluids from the same individuals generated identical DNA profile results. Template DNA derived from blood-strains deposited on a variety of matrix supports displayed robust amplification except for material derived from deposits on wood and Japanese orchid leaves. Mixtures of DNA templates could be interpreted with the minor component present in as little as ten percent of the total sample. Monoplex and multiplex amplifications produced identical amplified allele patterns, indicating that STR multiplex systems save template and increase efficiency in the amplification procedure without loss of quality. Analyses of genotype frequencies in African-American, Caucasian-American and Hispanic-American populations using all twelve loci were used to determine matching probabilities smaller than 1 in 1.14 x 10(8) and 1 in 2658 for the PowerPlex 1.1 and the FFFL Multiplex Systems, respectively. The matching probability achieved with the two systems combined is smaller than 1 in 3.03 x 10(11). The independence of alleles within loci was generally demonstrated by applying the exact test to demonstrate Hardy-Weinberg Equilibrium. All of the studies performed indicate that the PowerPlex 1.1/Amelogenin and FFFL Multiplex Systems are powerful, robust, and reliable investigative tools that can be used in the analysis of forensic samples.
Forensic Science International-genetics | 2011
Valerie C. Tucker; Andrew Hopwood; Cynthia J. Sprecher; Robert S. McLaren; Dawn R. Rabbach; Martin G. Ensenberger; Jonelle M. Thompson; Douglas R. Storts
Forensic Science International-genetics | 2012
Valerie C. Tucker; Andrew Hopwood; Cynthia J. Sprecher; Robert S. McLaren; Dawn R. Rabbach; Martin G. Ensenberger; Jonelle M. Thompson; Douglas R. Storts
Forensic Science International: Genetics Supplement Series | 2009
John M. Butler; Carolyn R. Hill; Margaret C. Kline; David L. Duewer; Cynthia J. Sprecher; Robert S. McLaren; Dawn R. Rabbach; Benjamin E. Krenke; Douglas R. Storts
Archive | 2000
Cindy Sprecher; Ben Krenke; Beth Amiott; Dawn R. Rabbach; Kelly Grooms