Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where de Mja Martien Voigt is active.

Publication


Featured researches published by de Mja Martien Voigt.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1995

A novel compact Ge-BGO Compton-suppression spectrometer

de Mja Martien Voigt; Jc Bacelar; Sl Micek; P Schotanus; Baw Verhoef; Yje Yves Wintraecken; P Vermeulen

Abstract A novel Compton-suppression spectrometer has been designed and its performance has been tested experimentally. The device consists of a single BGO crystal with a cylindrical well that holds a Ge crystal without interfering material between the crystals. Both crystals are cooled to an equilibrium temperature of 104 K which allows a proper performance of the Ge detector. The BGO crystal is read out by a single PM tube. Photodiodes have been applied to investigate the light yield and timing properties of BGO at low temperature. The light transport phenomena were well reproduced by computer simulations. The photopeak-to-total ratio amounts to 0.74 with an average suppression factor of 10.1 for a 137 Cs source and 0.60 and 6.4, respectively, for a 60 Co source. These results are well reproduced by Monte Carlo codes simulating the γ-ray interactions, also taking into account some charge-collection inefficiency.


Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms | 1999

A system for on-line monitoring of light element concentration distributions in thin samples

Pjm Peter Brands; Pha Peter Mutsaers; de Mja Martien Voigt

At the Cyclotron Laboratory, a scanning proton microprobe is used to determine concentration distributions in biomedical samples. The data acquired in these measurements used to be analysed in a time consuming off-line analysis. To avoid the loss of valuable measurement and analysis time, DYANA was developed. DYANA is an on-line method for the analysis of data from biomedical measurements. By using a database of background shapes, light elements such as Na and Mg, can be fitted even more precisely than in conventional fitting procedures. The entire analysis takes only several seconds and is performed while the acquisition system is gathering a new subset of data. Data acquisition must be guaranteed and may not be interfered by other parallel processes. Therefore, the analysis, the data acquisition and the experiment control is performed on a PCI-based Pentium personal computer (PC), running a real-time operating system. A second PC is added to run a graphical user interface for interaction with the experimenter and the monitoring of the analysed results. The system is here illustrated using atherosclerotic tissue but is applicable to all kinds of thin samples.


Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms | 1998

Co(III)EDTA as extra-cellular marker in μPIXE-analysis of rat cardiomyocytes

Ja John Quaedackers; Rmgj Rene Queens; Pha Peter Mutsaers; de Jjm Jeroen Goeij; de Mja Martien Voigt; van der Gj Ger Vusse

In previous studies no clear difference was found between the intra- and extra-cellular compartment in nuclear microprobe elemental distribution maps of freeze-dried cryo sections of heart tissue. Probably due to artefacts during the preparation of these samples, the intra-cellular and the extra-cellular content of elements are mixed up. In this article a method, using NaCo(III)EDTA as an extra-cellular marker, was applied to deconvolute the total ion content in an extra- and intra-cellular contribution. This method was both applied to normoxic heart tissue and low-flow ischemic heart tissue. Intra-cellular ion concentrations calculated from the corrected ion contents of the normoxic tissue agrees well with literature values. Moreover a clear elevation of the intra-cellular sodium and chlorine concentration was found in low-flow ischemic tissue.


Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms | 1998

Micro-PIXE and FT–IR microscopic studies of mineralized nodules formed in rat bone marrow stromal cell cultures

E. Rokita; Pha Peter Mutsaers; Ja John Quaedackers; G. Taton; de Mja Martien Voigt

Abstract A proton microprobe in combination with Proton Induced X-ray Emission (micro-PIXE) and Fourier transform–infrared (FT–IR) microscopy are used for examination of the elemental composition and structure of inorganic deposits formed in cell cultures of rat bone marrow. The results show that micro-PIXE is well suited for prior recognition of the localization and for the determination of the elemental composition of the deposits while FT–IR microscopy may be used to determine the structure of deposits in situ with a spatial resolution of about 20 μm. It is demonstrated that nodules in the cell culture are composed of different Ca compounds. In contrast to physiological mineralization, Ca–P compounds do not dominate the mineral phase. Discrepancies are observed between histomorphometric and micro-PIXE data.


Catalysis Letters | 1998

Imaging of hydrocarbon reactions in zeolite packed-bed reactors using positron emission profiling

Bg Bruce Anderson; Nj Noordhoek; D Danny Schuring; de Fjmm Gauw; de Am Arthur Jong; de Mja Martien Voigt; van Ra Rutger Santen

The ability of positron emission profiling (PEP) to measure concentration profiles of molecules labelled with positron-emitting nuclei, such as 11C, 13N, and 15O, inside chemical reactors has been demonstrated for the system n-hexane–Pt/H-zeolites under conditions typical of the hydroisomerization reaction. Data obtained in the absence of reaction were first measured and used to model mass transport processes in these biporous, packed-bed reactors. Images obtained under conditions where injected, labelled pulses underwent reaction revealed that the products did not exit the reactor and thus demonstrated the need for in situ measurement. Such experiments should provide a valuable new tool in the study of transient, initial phenomena so often of importance in heterogeneous catalysis, such as “preconditioning” and deactivation.


Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms | 1998

On-line elemental mapping in biomedical research

Pjm Peter Brands; Pha Peter Mutsaers; de Mja Martien Voigt

In biomedical research, elemental maps give valuable information about the role of elements in the aetiology of many diseases. For creating such elemental maps we use a scanning proton microprobe set-up to perform Particle Induced X-ray Emission (PIXE), Nuclear Backscattering Spectroscopy (NBS) and Nuclear Forward Scattering Spectroscopy (NFS) experiments simultaneously, preceded by a Scanning Transmission Ion Microscopy (STIM) experiment to localise the area of interest. PIXE is used to detect trace elements and NBS/NFS or STIM is used to determine local areal mass densities. Transferring experimental list-mode data into the thick target corrected concentration distributions is a time-consuming process. However, it would be advantageous to display continuously updated elemental maps as the data accumulate. This paper introduces a data processing method for use in biomedical research, based on dynamic analysis. For calculating concentrations, dynamic analysis uses a matrix transform technique instead of the nonlinear least squares fitting procedures in conventional methods. Applying dynamic analysis reduces the processing time from several hours to less than 1 min. The matrix correction factors for use in thick target corrections, are calculated using the local areal mass densities. The over all time reduction of this method is sufficient to calculate the intermediate, peak overlap resolved, background subtracted and thick target corrected concentration distributions while the data acquisition system is gathering a new subset of data.


Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms | 1998

Optimisation of Pt sensitivity in PIXE analysis of thin biological samples

Tb Tiourina; Pha Peter Mutsaers; de Mja Martien Voigt

Abstract To obtain Pt concentration distributions in tumor biopsies, micro-PIXE is used. The Limit of Detection (LOD) for Pt is determined by the background production cross section together with the production cross section for the Pt–L lines. Both are functions of the type and energy of the projectile. In order to optimise the experimental conditions, the proton energy is varied from 2.5 to 5 MeV and the corresponding X-ray spectra are analysed. The optimum LOD is about 1 μg/g for a sample thickness of 1 mg/cm2 and a total charge of 100 μC. A study is performed to investigate the possibility of elemental analysis by means of α excitation. The corresponding LOD is 6 μg/g with 200 μC charge (He++ was used). For α excitation, sample damage limits the beam current and, thus, causes a tremendous increase in the measurement time.


Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms | 1995

PIXE microanalysis of trace elements of the normoxic, ischemic and reperfused rat heart

Baw Verhoef; Peter M. Frederik; Phh Paul Bomans; van der Gj Ger Vusse; Pha Peter Mutsaers; de Ecp Lepper; de Mja Martien Voigt

With a 3 x 3 mu m(2) proton microbeam spatial distributions of Na, Mg, P, S, K, Ca and Fe were measured via PIXE in 50 x 50 mu m(2) areas of rat heart, sliced into 10-15 mu m thick cryosections. The isolated rat hearts were subjected to normal perfusion, ischemia and reperfusion. Substantial changes in the elemental distribution were found in tissue after 40 min. of reperfusion, particularly indicated by locally elevated Ca and decreased K levels. Electron microscopic examination was used for assessment of artefacts due to sample preparation and handling. Results of stained cryosections analyzed via STIM demonstrated that this latter technique can be employed prior to PIXE analysis to localize individual cells in freeze-dried cryosections.


Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms | 1999

State and history of heart tissue preparation for proton microprobe elemental analysis at the Eindhoven Cyclotron Laboratory

Ja John Quaedackers; Pha Peter Mutsaers; de Jjm Jeroen Goeij; de Mja Martien Voigt; van der Gj Ger Vusse

Proton microprobe techniques are useful in investigating ischemia-reperfusion induced ion shifts between cardiac muscle cells and interstitial fluid. Preliminary results have shown that proper analysis of ion concentrations in various cardiac compartments is hampered by dislocation of elements during sample preparation. In this study the different stages of the preparation were evaluated as possible sources of artifacts. After improvements of the sample preparation procedure, sharp ion concentration gradients within heart tissue preparations were obtained, indicating no noticeable ion dislocation at the scale of the measurements.


Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms | 1998

PROTON AND X-RAY MICROPROBES IN THE STUDIES OF THE MINERALIZATION PROCESS

E. Rokita; P Chevallier; Pha Peter Mutsaers; P Populus; G. Taton; de Mja Martien Voigt

Abstract A proton microprobe in combination with proton induced X-ray emission and a X-ray microprobe are used in the study of the mineralization process. It is demonstrated that the application of both methods enables the determination of the crystallographic structure of the inorganic phase in biological samples with a spatial resolution of about 20 μm.

Collaboration


Dive into the de Mja Martien Voigt's collaboration.

Top Co-Authors

Avatar

Pha Peter Mutsaers

Eindhoven University of Technology

View shared research outputs
Top Co-Authors

Avatar

Ja John Quaedackers

Eindhoven University of Technology

View shared research outputs
Top Co-Authors

Avatar

de Jjm Jeroen Goeij

Eindhoven University of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Baw Verhoef

Eindhoven University of Technology

View shared research outputs
Top Co-Authors

Avatar

E. Rokita

Jagiellonian University

View shared research outputs
Top Co-Authors

Avatar

de Am Arthur Jong

Eindhoven University of Technology

View shared research outputs
Top Co-Authors

Avatar

van Ra Rutger Santen

Eindhoven University of Technology

View shared research outputs
Top Co-Authors

Avatar

Bg Bruce Anderson

Eindhoven University of Technology

View shared research outputs
Top Co-Authors

Avatar

Jc Bacelar

Eindhoven University of Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge