Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Dean C. Carlow is active.

Publication


Featured researches published by Dean C. Carlow.


Journal of Chromatography B | 2015

Development and validation of a turbulent flow chromatography and tandem mass spectrometry method for the quantitation of methotrexate and its metabolites 7-hydroxy methotrexate and DAMPA in serum

Ryan C. Schofield; Lakshmi V. Ramanathan; Kazunori Murata; Marie E. Grace; Martin Fleisher; Melissa S. Pessin; Dean C. Carlow

A rapid and simple turbulent flow liquid chromatography (TFC-LC) method implementing positive heated electrospray ionization (HESI) for the accurate and precise determination of methotrexate (MTX), 7-hydroxy methotrexate (7-OH MTX), and 4-amino-4-deoxy-N(10)-methylpteroic acid (DAMPA) concentrations in serum was developed. MTX was isolated from serum samples (100μL) after protein precipitation with methanol containing formic acid and internal standard (MTX-D3) followed by centrifugation. The supernatant was injected into the turbulent flow liquid chromatography which is followed by electrospray positive ionization tandem mass spectrometry (TFC-LC-MS/MS) and quantified using a six-point calibration curve. For MTX and DAMPA the assays were linear from 10 to 1000nmol/L and for 7-OH MTX from 20 to 2000nmol/L. Dilutions of 10, 100 and 1000-fold were validated giving a clinically reportable range of 10nmol/L to 5×10(5)nmol/L. Within-day and between-day precisions at concentrations spanning the analytical measurement ranges were less than 10% for all three analytes. MTX, DAMPA and 7-OH MTX were sufficiently stable under all relevant analytical conditions. No significant matrix effect was observed during the method validation. The TFC-LC-MS/MS MTX method was also compared with three other clinically validated MTX assays: a dihydrofolate reductase (DHFR) inhibition assay, an immunoassay based on fluorescence polarization and a previously developed LC-MS/MS assay.


Nature Communications | 2017

Topical tacrolimus for the treatment of secondary lymphedema

Jason C. Gardenier; Raghu P. Kataru; Geoffrey E. Hespe; Ira L. Savetsky; Jeremy S. Torrisi; Gabriela D. García Nores; Dawit K. Jowhar; Matthew D. Nitti; Ryan C. Schofield; Dean C. Carlow; Babak J. Mehrara

Secondary lymphedema, a life-long complication of cancer treatment, currently has no cure. Lymphedema patients have decreased quality of life and recurrent infections with treatments limited to palliative measures. Accumulating evidence indicates that T cells play a key role in the pathology of lymphedema by promoting tissue fibrosis and inhibiting lymphangiogenesis. Here using mouse models, we show that topical therapy with tacrolimus, an anti-T-cell immunosuppressive drug, is highly effective in preventing lymphedema development and treating established lymphedema. This intervention markedly decreases swelling, T-cell infiltration and tissue fibrosis while significantly increasing formation of lymphatic collaterals with minimal systemic absorption. Animals treated with tacrolimus have markedly improved lymphatic function with increased collecting vessel contraction frequency and decreased dermal backflow. These results have profound implications for lymphedema treatment as topical tacrolimus is FDA-approved for other chronic skin conditions and has an established record of safety and tolerability.


Journal of Chromatography B | 2017

Sensitive simultaneous quantitation of testosterone and estradiol in serum by LC–MS/MS without derivatization and comparison with the CDC HoSt program

Ryan C. Schofield; Damodara R. Mendu; Lakshmi V. Ramanathan; Melissa S. Pessin; Dean C. Carlow

BACKGROUND Very sensitive measurements of serum estrogens and testosterone are important in adult and pediatric endocrinology and immunoassays are known to lack the required performance at very low levels. Our aim was to develop a sensitive HPLC-MS/MS assay for both estradiol (E2) and testosterone (Te) in serum without the need for chemical derivatization and using commercially available calibrators. METHODS Serum samples were prepared by the addition of internal standards followed by extraction using hexane:ethyl acetate. Chromatographic separation was achieved using a C18 column and mass spectrometry was performed in both positive and negative ion modes. RESULTS The lower limits of quantitation (LLOQs) of E2 and Te were 5pg/mL and 1ng/dL, respectively. The analytical measurement range (AMR) for E2 was 5-600pg/mL and 1-1,170ng/dL for Te. Assay accuracy was determined both by comparison with a LC-MS/MS method performed at a national laboratory and the CDC HoSt program. Comparison with samples analyzed by both methods showed excellent correlation. Within-day (N=10) and between-day (N=20) CVs at concentrations spanning the AMR were less than 7% for both analytes. CONCLUSION We have developed an accurate and highly sensitive assay to measure E2 and Te levels in serum by HPLC-MS/MS without chemical derivatization and using commercially available calibrators.


Clinical Biochemistry | 2015

Analytical performance of the Abaxis Piccolo Xpress® point of care analyzer in whole blood, serum, and plasma.

Kazunori Murata; Laurel Glaser; Mary Nardiello; Shaun Richardson; Lakshmi V. Ramanathan; Dean C. Carlow

OBJECTIVES To examine the analytical performance of 14 comprehensive metabolic panel analytes on the Abaxis Piccolo Xpress® Point of Care analyzer in serum, plasma, and whole blood. DESIGN AND METHODS Precision was evaluated by running two levels of control material over multiple days. Linearity was evaluated using material provided by the manufacturer and the College of American Pathologists (CAP) linearity surveys. Accuracy was evaluated by comparing the results from 60 patient specimens on the Piccolo Xpress® with the Ortho Vitros® 5600 analyzer. The method comparison was performed on all three specimen types intended for use on the Piccolo Xpress®: serum, heparinized plasma, and whole blood. Manufacturer suggested reference ranges for all 14 analytes were tested in serum and plasma specimens from 23 healthy volunteers. RESULTS High precision (CV ≤ 10%) was noted for all the analytes. Linearity was found to span the clinically useful range for all analytes. The method comparison demonstrated minimal proportional bias and good correlation for most of the analytes in all three matrices tested. The only exceptions were for sodium and total CO2, for which either significant proportional bias and/or poor correlation was noted in all three matrices. Significant bias was noted for AST in serum as well as for total bilirubin in plasma and whole blood. CONCLUSION The Piccolo Xpress® allows for the delivery of CMP results in a footprint small enough to be stored in a biological safety cabinet, while providing satisfactory performance for the majority of analytes.


Biology of Blood and Marrow Transplantation | 2018

Effects of Late Toxicities on Outcomes in Long-Term Survivors of Ex-Vivo CD34+-Selected Allogeneic Hematopoietic Cell Transplantation

Michael Scordo; Gunjan L. Shah; Satyajit Kosuri; Diego Adrianzen Herrera; Christina Cho; Sean M. Devlin; Molly Maloy; Jimmy Nieves; Taylor Borrill; Scott T. Avecilla; Richard Meagher; Dean C. Carlow; Richard J. O'Reilly; Esperanza B. Papadopoulos; Ann A. Jakubowski; Guenther Koehne; Boglarka Gyurkocza; Hugo Castro-Malaspina; Roni Tamari; Miguel-Angel Perales; Sergio Giralt; Brian C. Shaffer

The late adverse events in long-term survivors after myeloablative-conditioned allogeneic hematopoietic cell transplantation (HCT) with ex vivo CD34+ cell selection are not well characterized. Using the National Cancer Institutes Common Terminology Criteria for Adverse Events, version 4.0, we assessed all grade ≥3 toxicities from the start of conditioning to the date of death, relapse, or last contact in 131 patients who survived >1 year post-HCT, identifying 285 individual toxicities among 17 organ-based toxicity groups. Pretransplantation absolute lymphocyte count >.5 K/µL and serum albumin >4.0 g/dL were associated with a reduced risk of toxicities, death, and nonrelapse mortality (NRM), whereas serum ferritin >1000 ng/mL was associated with an increased risk of toxicities and NRM after 1 year. An HCT Comorbidity Index (HCT-CI) score ≥3 was associated with an increased risk of all-cause death and NRM, but was not associated with a specific increased toxicity risk after 1 year. Patients who incurred more than the median number of toxicities (n = 7) among all patients within the first year subsequently had an increased risk of hematologic, infectious, and metabolic toxicities, as well as an increased risk of NRM and inferior 4-year overall survival (OS) (67% versus 86%; P = .003) after the 1-year landmark. The development of grade II-IV acute graft-versus-host disease (GVHD) within the first year was associated with incurring >7 toxicities within the first year (P = .016), and also with an increased risk of all-cause death and NRM after 1 year. In multivariate models, cardiovascular, hematologic, hepatic, infectious, metabolic, neurologic, and pulmonary toxicities incurred after 1 year were independently associated with increased risk of death and NRM when adjusting for both HCT-CI and grade II-IV acute GVHD within the first year. One-year survivors of ex vivo CD34+ selection had a favorable 4-year OS of 77%, although the development of grade ≥3 toxicities after the first year was associated with poorer outcomes, emphasizing the fundamental importance of improving survivorship efforts that may improve long-term toxicity burden and outcome.


Biology of Blood and Marrow Transplantation | 2018

Impact of Toxicity on Survival for Older Adult Patients after CD34+ Selected Allogeneic Hematopoietic Stem Cell Transplantation

Gunjan L. Shah; Michael Scordo; Satyajit Kosuri; Diego Adrianzen Herrera; Christina Cho; Sean M. Devlin; Taylor Borrill; Dean C. Carlow; Scott T. Avecilla; Richard Meagher; Richard J. O'Reilly; Ann A. Jakubowski; Esperanza B. Papadopoulos; Guenther Koehne; Boglarka Gyurkocza; Hugo Castro-Malaspina; Brian C. Shaffer; Miguel-Angel Perales; Sergio Giralt; Roni Tamari

Ex vivo CD34+ selection before allogeneic hematopoietic stem cell transplantation (allo-HCT) reduces graft-versus-host disease without increasing relapse but usually requires myeloablative conditioning. We aimed to identify toxicity patterns in older patients and the association with overall survival (OS) and nonrelapse mortality (NRM). We conducted a retrospective analysis of 200 patients who underwent CD34+ selection allo-HCT using the ClinicMACS® system between 2006 and 2012. All grade 3 to 5 toxicities by CTCAE v4.0 were collected. Eighty patients aged ≥ 60 years with a median age of 64 (range, 60 to 73) were compared with 120 patients aged < 60 years. Median follow-up in survivors was 48.2 months. OS and NRM were similar between ages ≥ 60 and <60, with 1-year OS 70% versus 78% (P = .07) and 1-year NRM 23% versus 13% (P = .38), respectively. In patients aged ≥ 60 the most common toxicities by day 100 were metabolic, with a cumulative incidence of 88% (95% CI, 78% to 93%), infectious 84% (95% CI, 73% to 90%), hematologic 80% (95% CI, 69% to 87%), oral/gastrointestinal (GI) 48% (95% CI, 36% to 58%), cardiovascular (CV) 35% (95% CI, 25% to 46%), and hepatic 25% (95% CI, 16% to 35%). Patients aged ≥ 60 had a higher risk of neurologic (HR, 2.63 [95% CI, 1.45 to 4.78]; P = .001) and CV (HR, 1.65 [95% CI, 1.04 to 2.63]; P = .03) toxicities but a lower risk of oral/GI (HR, .58 [95% CI, .41 to .83]; P = .003) compared with those aged < 60. CV, hepatic, neurologic, pulmonary, and renal toxicities remained independent risk factors for the risk of death and NRM in separate multivariate models adjusting for age and hematopoietic cell transplantation-specific comorbidity index. Overall, the toxicity of a more intense regimen is potentially balanced by the absence of toxicity related to methotrexate and calcineurin inhibitors in older patients. Prospective study of toxicities after allo-HCT in older patients is essential.


Biology of Blood and Marrow Transplantation | 2017

The Impact of Toxicities on First-Year Outcomes after Ex Vivo CD34+–Selected Allogeneic Hematopoietic Cell Transplantation in Adults with Hematologic Malignancies

Satyajit Kosuri; Diego Adrianzen Herrera; Michael Scordo; Gunjan L. Shah; Christina Cho; Sean M. Devlin; Molly Maloy; Jimmy Nieves; Taylor Borrill; Dean C. Carlow; Scott T. Avecilla; Richard Meagher; Richard J. O'Reilly; Esperanza B. Papadopoulos; Ann A. Jakubowski; Guenther Koehne; Boglarka Gyurkocza; Hugo Castro-Malaspina; Brian C. Shaffer; Roni Tamari; Sergio Giralt; Miguel-Angel Perales

Factors that impact first-year morbidity and mortality in adults undergoing myeloablative allogeneic hematopoietic cell transplantation with ex vivo CD34+ selection have not been previously reported. We assessed all toxicities ≥ grade 3 from the start of conditioning to date of death, relapse, or last contact in 200 patients during the first year after transplantation, identifying 1885 individual toxicities among 17 organ-based toxicity groups. The most prevalent toxicities in the first year were of infectious, metabolic, hematologic, oral/gastrointestinal, hepatic, cardiac, and pulmonary etiologies. Renal complications were minimal. Grades II to IV and III and IV acute GVHD at day 100 were 11.5% and 3%, respectively. In separate multivariate models, cardiovascular, hematologic, hepatic, neurologic, pulmonary, and renal toxicities negatively impacted nonrelapse mortality (NRM) and overall survival during the first year. A higher-than-targeted busulfan level, patient cytomegalovirus seropositivity, and an Hematopoietic Cell Transplantation-Specific Comorbidity Index of ≥3 were associated with increased risk of NRM and all-cause death. Ex vivo CD34+ selection had a favorable 1-year OS of 75% and NRM of 17% and a low incidence of sinusoidal obstruction syndrome. These data establish a benchmark to focus efforts in reducing toxicity burden while improving patient outcomes.


Methods of Molecular Biology | 2016

Simultaneous Quantitation of Lamotrigine, Levetiracetam, 10-Hydroxycarbazepine, Topiramate, and Zonisamide in Serum Using HPLC-MS/MS.

Dean C. Carlow; Heng Shi; Ryan C. Schofield

Antiepileptic drugs (AEDs) are a diverse group of pharmacological agents used in the treatment of epileptic seizures. Over the past several decades some new AEDs, including lamotrigine (LTG), levetiracetam (LVA), oxcarbazepine (OXC), topiramate (TOP), and zonisamide (ZNS), have become widely used. This chapter describes a very simple and rapid liquid chromatography-tandem mass spectrometry method for simultaneous quantitation of LVA, ZNS, LTG, TOP, and MHD in human serum. The method requires a very small amount of serum (50 μL) for multiple drug measurements and has a total analysis time of 4 min that makes it well suited for routine clinical analysis of several drugs simultaneously. The imprecision (CVs) measured at various concentrations across the analytical measurement range (AMR) are less than 7% for all analytes. The AMR for each analyte is as follows: LVA (1-100 μg/mL), ZNS (0.8-80 μg/mL), TOP (0.5-50 μg/mL), and 0.6-60 μg/mL for LTG and MHD.


Academic Pathology | 2017

The Case for Laboratory Developed Procedures: Quality and Positive Impact on Patient Care

Karen L. Kaul; Linda M. Sabatini; Gregory J. Tsongalis; Angela M. Caliendo; Randall J. Olsen; Edward R. Ashwood; Sherri J. Bale; Robert Benirschke; Dean C. Carlow; Birgit Funke; Wayne W. Grody; Randall T. Hayden; Madhuri Hegde; Elaine Lyon; Kazunori Murata; Melissa S. Pessin; Richard D. Press; Richard B. Thomson

An explosion of knowledge and technology is revolutionizing medicine and patient care. Novel testing must be brought to the clinic with safety and accuracy, but also in a timely and cost-effective manner, so that patients can benefit and laboratories can offer testing consistent with current guidelines. Under the oversight provided by the Clinical Laboratory Improvement Amendments, laboratories have been able to develop and optimize laboratory procedures for use in-house. Quality improvement programs, interlaboratory comparisons, and the ability of laboratories to adjust assays as needed to improve results, utilize new sample types, or incorporate new mutations, information, or technologies are positive aspects of Clinical Laboratory Improvement Amendments oversight of laboratory-developed procedures. Laboratories have a long history of successful service to patients operating under Clinical Laboratory Improvement Amendments. A series of detailed clinical examples illustrating the quality and positive impact of laboratory-developed procedures on patient care is provided. These examples also demonstrate how Clinical Laboratory Improvement Amendments oversight ensures accurate, reliable, and reproducible testing in clinical laboratories.


Methods of Molecular Biology | 2016

Development of an Assay for Methotrexate and Its Metabolites 7-Hydroxy Methotrexate and DAMPA in Serum by LC-MS/MS

Ryan C. Schofield; Lakshmi V. Ramanathan; Kazunori Murata; Martin Fleisher; Melissa S. Pessin; Dean C. Carlow

Methotrexate (MTX) is a folic acid antagonist that is widely used as an immunosuppressant and chemotherapeutic agent. After high-dose administration of MTX serum levels must be monitored to determine when to administer leucovorin, a folic acid analog that bypasses the enzyme inhibition caused by MTX and reverses its toxicity. We describe a rapid and simple turbulent flow liquid chromatography (TFLC) method implementing positive heated electrospray ionization (HESI) for the accurate and precise determination of MTX, 7-hydroxymethotrexate (7-OH MTX), and 4-amino-4-deoxy-N(10)-methylpteroic acid (DAMPA) concentrations in serum. MTX is isolated from serum samples (100 μL) after protein precipitation with a methanolic solution containing internal standard (MTX-D3) followed by centrifugation. The supernatant is injected into the turbulent flow liquid chromatography which is followed by electrospray positive ionization tandem mass spectrometry (TFLC-ESI-MS/MS) and quantified using a six-point calibration curve. For MTX, 7-OH MTX, and DAMPA the assays were linear from 20 to 1000 nmol/L. Dilutions of 10-, 100-, and 1000-fold were validated giving a clinically reportable range of 20 to 1.0 × 10(6) nmol/L. Within-day and between-day precisions at concentrations spanning the analytical measurement ranges were less than 10 % for all three analytes.

Collaboration


Dive into the Dean C. Carlow's collaboration.

Top Co-Authors

Avatar

Ryan C. Schofield

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Guenther Koehne

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Gunjan L. Shah

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Roni Tamari

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Sean M. Devlin

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Sergio Giralt

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Boglarka Gyurkocza

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Hugo Castro-Malaspina

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Christina Cho

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Diego Adrianzen Herrera

Albert Einstein College of Medicine

View shared research outputs
Researchain Logo
Decentralizing Knowledge