Deanna Fuller
Indiana University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Deanna Fuller.
Sexually Transmitted Diseases | 2005
Julius Schachter; Max Chernesky; Dean E. Willis; Paul M. Fine; David H. Martin; Deanna Fuller; Jeanne A. Jordan; William M. Janda; Edward W. Hook
Background: Vaginal swabs were recently U.S. Food and Drug Administration-cleared for detecting Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (GC) using Gen-Probe Incorporated’s APTIMA COMBO2 Assay (AC2). We assessed the APTIMA CT Assay (ACT) for CT, APTIMA GC Assay (AGC) for GC, and AC2 for both organisms using patient- and clinician-collected vaginal swabs. Method: Women attending family planning, obstetrics and gynecology, or sexually transmitted disease (STD) clinics had first-catch urines (FCUs), patient-collected vaginal swabs, clinician-collected vaginal swabs, and endocervical swabs tested by ACT, AGC, and AC2. A second endocervical swab and FCU were tested using BD ProbeTec (Becton Dickinson) for CT and GC. We calculated sensitivity and specificity using vaginal swabs to detect CT and GC. Results: Of 1464 subjects enrolled, 180 had CT and 78 GC. ACT sensitivities and specificities for patient-collected vaginal swabs were 98.3% and 96.5%, respectively; for clinician-collected vaginal swabs, 97.2% and 95.2%, respectively. AGC sensitivities and specificities for patient-collected vaginal swabs were 96.1% and 99.3%, respectively; for clinician-collected vaginal swabs, 96.2% and 99.3%, respectively. AC2 results were similar. If an FCU tested positive for CT or GC, >94% of matching vaginal swabs were positive. Positive endocervical swabs showed slightly less concordance (>90% and >88%, respectively). More infected patients were identified using vaginal swabs than FCUs. With AC2, 171 CT-infected patients were identified using FCUs and 196 using patient-collected vaginal swabs. This difference was more pronounced for CT than for GC. Conclusions: Vaginal swab specimens allowed sensitive and specific detection of CT and GC in the APTIMA assays. Vaginal swabs identified as many infected patients as endocervical swabs and more than FCUs, and may well be the specimen of choice for screening.
Sexually Transmitted Diseases | 2005
Max Chernesky; Edward W. Hook; David H. Martin; Jeannine Lane; Randy Johnson; Jeanne A. Jordan; Deanna Fuller; Dean E. Willis; Paul M. Fine; William M. Janda; Julius Schachter
Background: Self-collected specimens can be used to screen asymptomatic women for Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (GC). We surveyed women’s opinions on ease and preferences as to sampling after collecting their own vaginal swab and urine and a physician collection of vaginal swab and cervical swab. Methods: In 7 North American cities, a questionnaire was used for women after they participated in a clinical trial of nucleic acid amplification testing of various specimens. A total of 1090 women consenting to gynecologic sampling for CT and GC (82% of those sampled) volunteered to complete the survey. We analyzed the data for ease of self-collection and preferences for a vaginal swab, urine, or cervical swab. Results: The average age was 26.6 years; 59.6% were black, 25.5% white, 11% Hispanic, 1.9% Asian, and 2% unknown. Thirty-five percent had more than one sex partner in the past 6 months, 84.9% had been previously tested for a sexually transmitted infection (STI), and 49.2% had experienced an STI. A total of 90.4% found it very easy to self-collect a vaginal swab. This was not influenced by age, education, or study site. Seventy-six percent preferred a vaginal swab over a pelvic examination, 60% over a urine collection, and 94% indicated that they would be tested more often if a vaginal swab was available. Conclusion: Self-collected vaginal swabs were easy to collect and patients preferred them over urine and cervical swabs.
Antimicrobial Agents and Chemotherapy | 2001
L. Joseph Wheat; Gretchen Cloud; Philip C. Johnson; Patricia Connolly; Mitchell Goldman; Ann Le Monte; Deanna Fuller; Thomas E. Davis; Richard Hafner
ABSTRACT Animal studies have shown that fungal burden correlates with survival during treatment with new antifungal therapies for histoplasmosis. The purpose of this report is to compare the clearance of fungal burden in patients with histoplasmosis treated with liposomal amphotericin B versus itraconazole. In two separate closed clinical trials that evaluated the efficacy of liposomal amphotericin B and itraconazole treatment of disseminated histoplasmosis in patients with AIDS, blood was cultured for fungus and blood and urine were tested forHistoplasma antigen. The clinical response rates were similar; 86% with liposomal amphotericin B (n = 51) versus 85% with itraconazole (n = 59). Of the patients with positive blood cultures at enrollment, after 2 weeks of therapy cultures were negative in over 85% of the liposomal amphotericin B group versus 53% of the itraconazole group (P = 0.0008). Furthermore, after 2 weeks, median antigen levels in serum fell by 1.6 U in the liposomal amphotericin B group versus 0.1 U in the itraconazole group (P = 0.02), and those in urine fell by 2.1 U in the liposomal amphotericin B group and 0.2 U in the itraconazole group (P = 0.0005). The more rapid clearance of fungemia supports the use of liposomal amphotericin B rather than itraconazole for initial treatment of moderately severe or severe histoplasmosis.
Journal of Clinical Microbiology | 2005
Max Chernesky; David H. Martin; Edward W. Hook; Dean E. Willis; Jeanne A. Jordan; S. Wang; J. R. Lane; Deanna Fuller; Julius Schachter
ABSTRACT A clinical evaluation was conducted in six North American centers to determine the ability of APTIMA CT (ACT) and APTIMA GC (AGC) nucleic acid amplification assays to detect Chlamydia trachomatis and Neisseria gonorrhoeae infections in 1,322 men by testing their urethral swabs and first-catch urine (FCU). The results obtained with ACT and AGC assays were compared to an infected patient status determined by testing the specimens with the APTIMA Combo 2 and the BD ProbeTec energy transfer multiplex assays. Symptoms did not influence the values. Positive and negative agreements of the ACT and AGC assays for individual specimens were high, with each comparator assay ranging between 94.3 and 100% for positives and 93.9 and 99.4% for negatives. The ACT and AGC assays performed on noninvasive specimens such as FCU effectively identified C. trachomatis or N. gonorrhoeae infections in symptomatic and asymptomatic men and should be suitable for screening male populations.
Journal of Clinical Microbiology | 2005
Julius Schachter; Edward W. Hook; David H. Martin; Dean E. Willis; Paul M. Fine; Deanna Fuller; Jeanne A. Jordan; William M. Janda; Max Chernesky
ABSTRACT The Centers for Disease Control and Prevention recommended confirming positive screening tests for Chlamydia trachomatis when positive predictive values are <90%. It is accepted that less sensitive tests (i.e., culture and immunoassays) should not be used to confirm the results of more sensitive nucleic acid amplification tests (NAATs). We show that the same principle applies when NAATs are used for confirmation.
Chest | 2010
Chadi A. Hage; Thomas E. Davis; Deanna Fuller; Lindsey Egan; John Witt; L. Joseph Wheat; Kenneth S. Knox
BACKGROUND Detection of antigen in BAL is useful for diagnosis of histoplasmosis. The MVista Histoplasma antigen enzyme immunoassay has been modified to permit quantification. The purpose of this study is to compare the sensitivity of the quantitative antigen detection assay with cytopathology and culture of BAL specimens. METHODS BAL from patients with histoplasmosis who were evaluated at the Indiana University Medical Center and controls without histoplasmosis were studied. BAL fluid was tested in the quantitative Histoplasma antigen assay. RESULTS Antigen was detected in the BAL in 93.5% of patients with histoplasmosis, 80% with blastomycosis, and 0% of controls with nonfungal infections. Antigen was detected in the urine of 79% and serum in 65% of patients with histoplasmosis. Cytopathology was positive in 48% and culture in 48% of patients with histoplasmosis, and 40% and 60% of patients with blastomycosis, respectively. Serology was positive in 65%. Combining BAL antigen detection and BAL cytopathology, both methods for rapid diagnosis, the sensitivity was 96.8% in histoplasmosis and 80% in blastomycosis. CONCLUSIONS Detection of antigen in BAL complements antigen detection in serum and urine as an objective diagnostic test for histoplasmosis.
Journal of Clinical Microbiology | 2012
Melissa K. Deck; Erica S. Anderson; Rebecca J. Buckner; Georgia Colasante; James M. Coull; Benjamin Crystal; Phyllis Della Latta; Martin Fuchs; Deanna Fuller; Will Harris; Kevin C. Hazen; Lisa L. Klimas; Daniel Lindao; Michelle C. Meltzer; Margie Morgan; Janeen Shepard; Sharon Stevens; Fann Wu; Mark J. Fiandaca
ABSTRACT A novel rapid peptide nucleic acid fluorescence in situ hybridization (FISH) method, Staphylococcus QuickFISH, for the direct detection of Staphylococcus species from positive blood culture bottles was evaluated in a multicenter clinical study. The method utilizes a microscope slide with predeposited positive- and negative-control organisms and a self-reporting 15-min hybridization step, which eliminates the need for a wash step. Five clinical laboratories tested 722 positive blood culture bottles containing Gram-positive cocci in clusters. The sensitivities for detection of Staphylococcus aureus and coagulase-negative staphylococci (CoNS) were 99.5% (217/218) and 98.8% (487/493), respectively, and the combined specificity of the assay was 89.5% (17/19). The combined positive and negative predictive values of the assay were 99.7% (696/698) and 70.8% (17/24), respectively. Studies were also performed on spiked cultures to establish the specificity and performance sensitivity of the method. Staphylococcus QuickFISH has a turnaround time (TAT) of <30 min and a hands-on time (HOT) of <5 min. The ease and speed of the method have the potential to improve the accuracy of therapeutic intervention by providing S. aureus/CoNS identification simultaneously with Gram stain results.
Sexually Transmitted Diseases | 2011
Stephanie N. Taylor; Barbara Van Der Pol; Rebecca Lillis; Edward W. Hook; William D. LeBar; Thomas Davis; Deanna Fuller; Leandro Mena; Paul Fine; Charlotte A. Gaydos; David H. Martin
Background: This study evaluated the performance of the BD ProbeTec Chlamydia trachomatis Qx (CTQ) Amplified DNA Assay on the BD Viper System with XTR Technology in a multicenter study. Methods: Specimens were collected at 7 geographically diverse clinical sites from 1538 women and men attending sexually transmitted disease, family planning, and obstetrics and gynecology clinics. There were 1465 evaluable participants, 993 women and 472 men. CTQ assay results from female endocervical, self-collected vaginal, male urethral swab specimens, and male and female neat (unpreserved) urine specimens as well as those obtained using the Urine Preservative Transport (UPT) tube for the CTQ assay were compared with patient-infected status (PIS). PIS was determined based on the combined results from Aptima Combo 2 and BD ProbeTec ET CT Amplified DNA Assay. Results: The sensitivity versus PIS for endocervical, vaginal, and both female urine samples was 91.3%, 96.5%, and 93.0%, respectively. The specificity for the same specimen types was 98.3%, 99.2%, and 99.4% (urine neat) and 99.2% (UPT), respectively. The sensitivity versus PIS for male urethral swabs and both male neat and UPT urine were 92.1% and 98%, respectively, with specificities of 98.4%, 99.2%, and 98.1%, respectively. Conclusions: The CTQ assay demonstrated performance characteristics comparable with other commercially available nucleic acid-based tests such as Aptima Combo 2 and BD ProbeTec ET CT-Amplified DNA assay. Vaginal swabs and male urine specimens, the sample types recommended by the Centers for Disease Control for chlamydia screening, both performed at least as well as other sample types evaluated.
Journal of Clinical Microbiology | 2014
Barbara Van Der Pol; James A. Williams; Stephanie N. Taylor; Catherine L. Cammarata; Charles A. Rivers; Barbara A. Body; Melinda B. Nye; Deanna Fuller; Jane R. Schwebke; Mathilda Barnes; Charlotte A. Gaydos
ABSTRACT Trichomonas vaginalis is the most prevalent nonviral sexually transmitted infection worldwide, and improved diagnostic methods are critical for controlling this pathogen. Diagnostic assays that can be used in conjunction with routine chlamydia/gonorrhea nucleic acid-based screening are likely to have the most impact on disease control. Here we describe the performance of the new BD T. vaginalis Qx (TVQ) amplified DNA assay, which can be performed on the automated BD Viper system. We focus on data from vaginal swab samples, since this is the specimen type routinely used for traditional trichomonas testing and the recommended specimen type for chlamydia/gonorrhea screening. Vaginal swabs were obtained from women attending sexually transmitted disease or family planning clinics at 7 sites. Patient-collected vaginal swabs were tested by the TVQ assay, and the Aptima T. vaginalis (ATV) assay was performed using clinician-collected vaginal swabs. Additional clinician-collected vaginal swabs were used for the wet mount and culture methods. Analyses included comparisons versus the patient infection status (PIS) defined by positive results with the wet mount method or culture, direct comparisons assessed with κ scores, and latent class analysis (LCA) as an unbiased estimator of test accuracy. Data from 838 women, 116 of whom were infected with T. vaginalis, were analyzed. The TVQ assay sensitivity and specificity estimates based on the PIS were 98.3% and 99.0%, respectively. The TVQ assay was similar to the ATV assay (κ = 0.938) in direct analysis. LCA estimated the TVQ sensitivity and specificity as 98.3 and 99.6%, respectively. The TVQ assay performed well using self-collected vaginal swabs, the optimal sample type, as recommended by the CDC for chlamydia/gonorrhea screening among women.
Medical Mycology | 2008
Lindsey Egan; Patricia Connolly; L. Joseph Wheat; Deanna Fuller; Thomas E. Davis; Kenneth S. Knox; Chadi A. Hage
We evaluated the Fungitell beta-glucan (BG) test with specimens from patients with presumed histoplasmosis. The sensitivity of the test was 87% in histoplasmosis cases and had a specificity of 68% with controls. Histoplasmosis should be considered as a possible cause for a positive BG test, but such results may be found with many other conditions that are clinically similar to this fungal disease. Therefore, there is a need to conduct confirmatory tests for histoplasmosis in the appropriate clinical setting.