Journal of Occupational and Environmental Hygiene | 2011
Dennis J. Viscusi; Michael S. Bergman; Debra Novak; Kimberly A. Faulkner; Andrew J. Palmiero; Jeffrey B. Powell; Ronald E. Shaffer
The objective of this study was to determine if ultraviolet germicidal irradiation (UVGI), moist heat incubation (MHI), or microwave-generated steam (MGS) decontamination affects the fitting characteristics, odor, comfort, or donning ease of six N95 filtering facepiece respirator (FFR) models. For each model, 10 experienced test subjects qualified for the study by passing a standard OSHA quantitative fit test. Once qualified, each subject performed a series of fit tests to assess respirator fit and completed surveys to evaluate odor, comfort, and donning ease with FFRs that were not decontaminated (controls) and with FFRs of the same model that had been decontaminated. Respirator fit was quantitatively measured using a multidonning protocol with the TSI PORTACOUNT Plus and the N95 Companion accessory (designed to count only particles resulting from face to face-seal leakage). Participants’ subjective appraisals of the respirators odor, comfort, and donning ease were captured using a visual analog scale survey. Wilcoxon signed rank tests compared median values for fit, odor, comfort, and donning ease for each FFR and decontamination method against their respective controls for a given model. Two of the six FFRs demonstrated a statistically significant reduction (p < 0.05) in fit after MHI decontamination. However, for these two FFR models, post-decontamination mean fit factors were still ≥100. One of the other FFRs demonstrated a relatively small though statistically significant increase (p < 0.05) in median odor response after MHI decontamination. These data suggest that FFR users with characteristics similar to those in this study population would be unlikely to experience a clinically meaningful reduction in fit, increase in odor, increase in discomfort, or increased difficulty in donning with the six FFRs included in this study after UVGI, MHI, or MGS decontamination. Further research is needed before decontamination of N95 FFRs for purposes of reuse can be recommended.
AAOHN Journal | 2016
Kerri Wizner; Lindsay Stradtman; Debra Novak; Ronald E. Shaffer
An online questionnaire was developed to explore respiratory protective device (RPD) prevalence in U.S. health care facilities. The survey was distributed to professional nursing society members in 2014 and again in 2015 receiving 322 and 232 participant responses, respectively. The purpose of this study was to explore if the emergency preparedness climate associated with Ebola virus disease changed the landscape of RPD use and awareness. Comparing response percentages from the two sampling time frames using bivariate analysis, no significant changes were found in types of RPDs used in health care settings. N95 filtering facepiece respirators continue to be the most prevalent RPD used in health care facilities, but powered air-purifying respirators are also popular, with regional use highest in the West and Midwest. Understanding RPD use prevalence could ensure that health care workers receive appropriate device trainings as well as improve supply matching for emergency RPD stockpiling.
AAOHN Journal | 2016
Kristina Peterson; Bonnie Rogers; Lisa M. Brosseau; Julianne Payne; Jennifer Cooney; Lauren Joe; Debra Novak
This article compares hospital managers’ (HM), unit managers’ (UM), and health care workers’ (HCW) perceptions of respiratory protection safety climate in acute care hospitals. The article is based on survey responses from 215 HMs, 245 UMs, and 1,105 HCWs employed by 98 acute care hospitals in six states. Ten survey questions assessed five of the key dimensions of safety climate commonly identified in the literature: managerial commitment to safety, management feedback on safety procedures, coworkers’ safety norms, worker involvement, and worker safety training. Clinically and statistically significant differences were found across the three respondent types. HCWs had less positive perceptions of management commitment, worker involvement, and safety training aspects of safety climate than HMs and UMs. UMs had more positive perceptions of management’s supervision of HCWs’ respiratory protection practices. Implications for practice improvements indicate the need for frontline HCWs’ inclusion in efforts to reduce safety climate barriers and better support effective respiratory protection programs and daily health protection practices.
AAOHN Journal | 2014
Barbara J. Burgel; Debra Novak; Holly Elizabeth Carpenter; MaryAnn Gruden; Ann M. Lachat; Deborah Taormina
Additional findings are presented from a 2012 nationwide survey of 2,072 occupational health nurses regarding how they achieved competence in respiratory protection, their preferred methods of learning, and how they motivated employees to use respiratory protection. On-the-job training, taking a National Institute for Occupational Safety and Health spirometry course, or attending professional conferences were the primary ways occupational health nurses gained respiratory protection knowledge. Attending professional conferences was the preferred method of learning, varying by type of industry and years of occupational health nurse experience. Employee motivational strategies were not widely used; the most common strategy was to tailor respiratory protection training to workplace culture. Designing training methods that match learning preferences, within the context of the organizations safety and quality improvement culture, is a key recommendation supported by the literature and these findings. Including respiratory protection content and competencies in all levels of academic nursing education is an additional recommendation. Additional research is needed to link training strategies with consistent and correct use of respiratory protection by employees.
Journal of Occupational and Environmental Hygiene | 2012
Tony Rozzi; Jay L. Snyder; Debra Novak
Disposable filtering facepiece respirators (FFRs) used by health care workers are not designed to reduce the inhalation of volatile organic compounds (VOCs). Smoke-generating surgical procedures release VOCs and have been associated with the following complaints: foul smell, headaches, nausea, irritated throat and lungs, and asthma. Organic vapor FFRs that contain activated carbon are used by industrial workers to provide odor relief. These respirators remove irritating odors but are not marketed as respirators that provide respiratory protection against a gas or vapor. This study investigated the aromatic hydrocarbon adsorption capabilities of nuisance organic vapor (OV) FFRs. Three OV FFR models were tested to determine the 10% breakthrough time of three aromatic hydrocarbons at ambient room temperature and relative humidity. All respirator models were exposed to each vapor separately in three duplicate tests (n = 27). The respirator was sealed with silicone to an AVON-ISI headform that was placed in a chamber and exposed to VOC-laden air (20 ppm, 37 L/min). Periodically, gas samples were directed to an SRI gas chromatograph (Model 8610C) for analysis. All respirators performed similarly. The average 10% breakthrough values for all tests were at least 64 min, 96 min, and 110 min for benzene, toluene, and xylene, respectively. Respirators were tested with challenge concentrations at nuisance levels (20 ppm) and did not exceed 10% breakthrough values for at least 61 min. While the results of this pilot study hold promise, there is a need for further investigation and validation to determine the effectiveness of nuisance FFRs in mitigating organic vapors such as benzene, toluene, and xylene.
Annals of Occupational Hygiene | 2014
Nina L. Turner; Jeffrey B. Powell; Edward J. Sinkule; Debra Novak
The goal of this study was to evaluate the respiratory and metabolic stresses of air-fed ensembles used by workers in the nuclear, chemical, and pharmaceutical industries during rest, low-, and moderate-intensity treadmill exercise. Fourteen men and six women wore two different air-fed ensembles (AFE-1 and AFE-2) and one two-piece supplied-air respirator (SA) at rest (REST) and while walking for 6min at oxygen consumption (V.O2) rates of 1.0 (LOW) and 2.0 l min(-1) (MOD). Inhaled CO2 (FICO2), inhaled O2 (FIO2), pressure, and temperature were measured continuously breath-by-breath. For both LOW and MOD, FICO2 was significantly lower (P < 0.03) and FIO2 was significantly greater (P < 0.008) for SA compared with AFE-1 and AFE-2 in women, while in men, similar trends were observed. Significantly lower FICO2 (P < 0.009) and significantly greater FIO2 (P < 0.04) were consistently observed in AFE-1 compared with AFE-2 in men during LOW and MOD. For both men and women, average FICO2 exceeded 2.0% in AFE-2 during MOD. During LOW and MOD, average FIO2 in AFE-1 and AFE-2 dropped <19.5% in men and women. For men and women, average inhalation pressures (PIave) were significantly greater in both air-fed ensembles than SA (P < 0.001) during REST, LOW, and MOD. Inhaled gas temperature was significantly lower in SA than in either air-fed ensemble (P < 0.001). When the air supply was shut off during walking, the time taken for minimum FICO2 to reach 2.0% was <38 s for all three ensembles in both men and women, an observation that has implications for the design of emergency escape protocols for air-fed ensemble wearers. Results show that inhaled gas concentrations may reach physiologically stressful levels in air-fed ensembles during moderate-intensity treadmill walking.
American Journal of Infection Control | 2013
Stella Beckman; Barbara L. Materna; Suzi Goldmacher; Jennifer Zipprich; Maryann D'Alessandro; Debra Novak; Robert Harrison
American Journal of Infection Control | 2015
Kristina Peterson; Debra Novak; Lindsay Stradtman; David Wilson; Lance Couzens
AAOHN Journal | 2013
Barbara J. Burgel; Debra Novak; Candace Burns; Annette Byrd; Holly Elizabeth Carpenter; MaryAnn Gruden; Ann M. Lachat; Deborah Taormina
Archive | 2016
Jaclyn Krah; Debra Novak; Lindsay Stradtman