Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Denis Brisbois is active.

Publication


Featured researches published by Denis Brisbois.


Radiology | 2010

MR imaging of iron phagocytosis in intraluminal thrombi of abdominal aortic aneurysms in humans.

Alain Nchimi; Olivier Defawe; Denis Brisbois; Thomas Broussaud; Jean-Olivier Defraigne; Paul Magotteaux; Brigitte Massart; Jean Michel Serfaty; Xavier Houard; Jean Michel; Natzi Sakalihasan

PURPOSE To prospectively determine if superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging could help visualize leukocyte phagocytic activities in human abdominal aortic aneurysms (AAAs). MATERIALS AND METHODS This study was approved by the institutional ethics committee; all patients gave informed consent. Preoperative MR imaging data, including unenhanced and SPIO-enhanced T1-, T2*-, and T2-weighted transverse images of the entire AAA, obtained 1 hour after contrast enhancement from 15 patients (mean age, 72.7 years +/- 8.2; range, 60-83 years), 10 men (mean age, 73.5 years +/- 7.9; range, 60-83 years) and five women (mean age, 71.2 years +/- 9.4; range 60-82), were retrospectively evaluated. Morphologic appearance and semiquantitative and contrast-to-noise ratio (CNR) analyses of the thrombi were performed. Thrombi were analyzed semiquantitatively at microscopy after staining with hematoxylin-eosin, CD68, and CD66b. Levels of promatrix metalloproteinase (pro-MMP)-2 and pro-MMP-9, MMP-2 and MMP-9, and their mRNA located in the thrombus were assessed by using zymography and quantitative reverse transcriptase polymerase chain reaction analysis. Nonparametric statistics of the Spearman rank correlation were calculated to evaluate correlations between the aneurysm thrombus signal level decrease after SPIO and the levels of CD68(+), CD66b(+) cells, pro-MMP-2 and pro-MMP-9, MMP-2 and MMP-9, and MMP-9 mRNA. RESULTS The pre-SPIO CNRs in the luminal sublayer of the thrombus and the deeper thrombus were -10.20 +/- 12.69 and -5.68 +/-10.38, respectively. After SPIO, the CNRs decreased to -21.34 +/-13.07 (P < .001) and -12.44 +/- 14.56, respectively (P < .012). There was a significant linear correlation between the thrombus signal level decrease and the levels of CD68(+) and CD66b(+) cells, pro-MMP-9, and MMP-9 mRNA (P < .05). CONCLUSION MR imaging allows in vivo demonstration of SPIO uptake at the luminal interface of the thrombus. This uptake is correlated to the abundance of leukocytes. SUPPLEMENTAL MATERIAL http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.09090657/-/DC1.


American Journal of Roentgenology | 2006

Quadruple-Phase MDCT of the Liver in Patients with Suspected Hepatocellular Carcinoma: Effect of Contrast Material Flow Rate

Wolfgang Schima; Renate Hammerstingl; Carlo Catalano; Luis Martí-Bonmatí; Ernst J. Rummeny; Francisco Tardáguila Montero; Albert Dirisamer; Bernd Westermayer; Massimo Bellomi; Denis Brisbois; Patrick Chevallier; Martin Dobritz; Jacques Drouillard; Francesco Fraioli; María Jesús Martínez; Sandro Morassut; Thomas J. Vogl

OBJECTIVE The purposes of this study were to evaluate the effect of contrast material flow rate (3 mL/sec vs 5 mL/sec) on the detection and visualization of hepatocellular carcinoma (HCC) with MDCT and the safety profile of iodixanol at different injection rates. SUBJECTS AND METHODS In a prospective, randomized multicenter trial, 97 patients (83 men and 14 women, with a mean age of 64 years) suspected of having HCC underwent quadruple-phase (double arterial, portal venous, delayed phase) 4-16-MDCT. Patients were randomized to receive iodixanol, 320 mg I/mL (1.5 mL/kg body weight), at a flow rate of 3 mL/sec (48 patients) or 5 mL/sec (49 patients). Qualitative (lesion detection, image quality) and quantitative (liver and aortic enhancement, tumor-liver contrast) analyses and safety assessment were performed. RESULTS Overall, 145 HCCs were detected in the 5 mL/sec group and 100 HCCs in the 3 mL/sec group (p < 0.05). More lesions equal to or less than 1 cm were detected at 5 mL/sec (33 vs 16 lesions). The late arterial phase showed significantly more lesions than the early, arterial phase (133 vs 100 and 96 vs 67 lesions, respectively, p < 0.0001). Hyperattenuating HCCs were better visualized in the late arterial phase at 5 mL/sec (excellent visualization: 54% vs 27%). Using a flow of 5 mL/sec did not increase the rate of patient discomfort or contrast media-related adverse events. Most discomfort in both groups was of mild intensity and there was no severe discomfort. CONCLUSION For detection of HCC with MDCT, a higher flow rate of 5 mL/sec is recommended. Visualization of hyperattenuating HCC is improved with no greater discomfort or adverse events.


American Journal of Roentgenology | 2009

Free-Breathing Accelerated Gadolinium-Enhanced MR Angiography in the Diagnosis of Renovascular Disease

Alain Nchimi; Denis Brisbois; Roland Materne; Thomas Broussaud; Isabelle Mancini; Paul Magotteaux

OBJECTIVE The purpose of this study was to assess the feasibility and accuracy of accelerated free-breathing and breath-hold gadolinium-enhanced MR angiography of the main renal arteries compared with digital subtraction angiography. MATERIALS AND METHODS Renal MR angiograms and catheter angiograms of 47 patients (19 men, 28 women; mean age, 68.1 +/- 15.1 years; range, 28-86 years) were reviewed. Thirty-one of the patients underwent free-breathing and 16 underwent breath-hold MR angiography with the same accelerated multiphase imaging protocol. Images were analyzed for examination quality, percentage narrowing of the main renal artery, and visibility of the branches. Diagnostic values of MR angiography were calculated with catheter angiography as the standard of reference. RESULTS Sixty-five arteries, 24 of which (37%) had > 49% narrowing, were evaluated in the free-breathing group, and 37 arteries, six of which (16%) had > 49% narrowing, were evaluated in the breath-hold group. Comparison with digital subtraction angiography showed 100% (24/24) sensitivity and 95% (39/41) specificity for > 49% renal artery stenosis and 88% sensitivity (15/17) and 100% (48/48) specificity for > 74% renal artery stenosis in the free-breathing group. In the breath-hold group, sensitivity was 100% (6/6) and specificity 97% (30/31) for > 49% renal artery stenosis, and sensitivity was 100% (5/5) and specificity 100% (32/32) for > 74% renal artery stenosis. None of the examinations was nondiagnostic for the main renal arteries, but a smaller number of visible arterial tree subdivisions were found in the free-breathing group (average, 3.64 per patient) than in the breath-hold group (average, 5.87 per patient) (p = 0.035). CONCLUSION Like breath-hold examinations, accelerated free-breathing MR angiographic examinations are feasible and accurate in evaluation of the main renal arteries.


EMC - Radiologie et imagerie médicale - Abdominale - Digestive | 2006

Cancers du pancréas exocrine

Unal Duran; Denis Brisbois; R. marterne; Charlemagne Noukoua Tchuisse; Noëlla Bletard; Eugène Mutijima Nzaramba; Alain Nchimi Longang


Réalités Cardiologiques | 2008

Rôle de l'IRM dans la détection de viabilité

B. Raskinet; Denis Brisbois; A. Morar; Thomas Broussaud; Isabelle Mancini; Alain Nchimi Longang


JBR-BTR : organe de la Societe royale belge de radiologie (SRBR) = orgaan van de Koninklijke Belgische Vereniging voor Radiologie (KBVR) | 2007

Detection de la coronaropathie asymptomatique par etude de la perfusion myocardique sous stress a l'adenosine en resonance magnetique: resultats preliminaires.

Denis Brisbois; B. Raskinet; Julien Djekic; A. Morar; Th Broussaud; Isabelle Mancini; Paul Magotteaux; Alain Nchimi Longang


Archive | 2006

Cancer du pancréas exocrine. Traité de Radiodiagnostic IV - Appareil digestif de l’EMC

Alain Nchimi Longang; Denis Brisbois; Roland Materne; Paul Magotteaux


Archive | 2004

Metabolic Assessment of Abdominal Aortic Aneurysms

Alain Nchimi Longang; Denis Brisbois; Benjamin Grayet; Pierre Gomez; Paul Magotteaux


Archive | 2004

Nonbreathhold Gadolinium-enhanced MRA of the Renal Arteries with Partially Parallel 3D Time-resolved Imaging

Alain Nchimi Longang; Denis Brisbois; Roland Materne; Thomas Broussaud; Paul Magotteaux


JBR-BTR : organe de la Societe royale belge de radiologie (SRBR) = orgaan van de Koninklijke Belgische Vereniging voor Radiologie (KBVR) | 2002

Aortofemorographie par resonance magnetique nucleaire versus arteriographie conventionnelle: evaluation prospective.

Alain Nchimi Longang; Denis Brisbois; E. Donkers; J. F. Biquet; C. Saive; A. Jadot; Paul Magotteaux

Collaboration


Dive into the Denis Brisbois's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Roland Materne

Université catholique de Louvain

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge