Denis V. Petrenko
National Research Nuclear University MEPhI
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Denis V. Petrenko.
Proceedings of SPIE | 2014
Alexander S. Novikov; S. E. Ulin; I. V. Chernysheva; V. V. Dmitrenko; V. M. Grachev; Denis V. Petrenko; Alexander E. Shustov; Z. M. Uteshev; K. F. Vlasik
A description of the xenon detector (XD) for gamma-ray line emission registration is presented. The detector provides high energy resolution and is able to operate under extreme environmental conditions (wide temperature range and unfavorable acoustic action). Resistance to acoustic noise as well as improvement in energy resolution has been achieved by means of real-time digital pulse processing. Another important XD feature is the ionization chamber’s thin wall with composite housing, which significantly decreases the mass of the device and expands its energy range, especially at low energies.
Proceedings of SPIE | 2015
Alexander S. Novikov; S. E. Ulin; V. V. Dmitrenko; V. M. Grachev; Viktor N. Stekhanov; K. F. Vlasik; Z. M. Uteshev; I. V. Chernysheva; Alexander E. Shustov; Denis V. Petrenko
In the experiment SIGNAL, which is planned to take place on board spacecraft INTERHELIOPROBE, a xenon gammaray spectrometer is to be used. The gamma-ray spectrometer in question has been chosen because of its characteristics permitting detailed study of solar gamma-radiation under rough experimental conditions. The equipment is able to provide: high energy resolution (5-6-fold better than that of scintillation detectors), performance at high temperatures, steady operation under significant vibroacoustic load, and high radiation resistance of the working medium. The aforesaid properties of the xenon gamma-ray spectrometer meet goals and objectives of the experiment SIGNAL. The description of ballistics scenario and operation orbit of the INTERHELIOPROBE spacecraft (SC) are presented.
Journal of Physics: Conference Series | 2016
P Wai; V. V. Dmitrenko; S. S. Grabchikov; K. F. Vlasik; Alexander S. Novikov; Denis V. Petrenko; V Trukhanov; S. E. Ulin; Z. M. Uteshev; V Chernysheva; Alexander E. Shustov
In different materials for magnetic shields, the maximum permeability is achieved for different values of the magnetic field. This determines the choice of material. So for protection from magnetic fields strength of 10 - 150 A/m it is advisable to apply the amorphous ribbon 84KXCP. For stronger fields (more than 400 A/m) it is recommended to use MFS based on Ni20Fe80. Use of these materials allows creating an effective shield working in a wide range of magnetic field strengths.
Journal of Applied Remote Sensing | 2015
Alexander S. Novikov; S. E. Ulin; I. V. Chernysheva; V. V. Dmitrenko; V. M. Grachev; Denis V. Petrenko; Alexander E. Shustov; Z. M. Uteshev; K. F. Vlasik
Abstract. A description of the xenon detector (XD) for ecological applications is presented. The detector provides high energy resolution and is able to operate under extreme environmental conditions (wide temperature range and unfavorable acoustic action). Resistance to acoustic noise as well as improvement in energy resolution has been achieved by means of real-time digital pulse processing. Another important XD feature is the ionization chamber’s thin wall with composite housing, which significantly decreases the mass of the device and expands its energy range, especially at low energies.
Bulletin of the Lebedev Physics Institute | 2014
S. N. P’ya; K. F. Vlasik; V. M. Grachev; V. V. Dmitrenko; Alexander S. Novikov; Denis V. Petrenko; Alexander E. Shustov; Z. M. Uteshev; S. E. Ulin; I. V. Chernysheva
The results of the calculation of the detection efficiency of gamma-rays for the xenon gamma spectrometer (XGS) obtained using the GEANT4 Monte Carlo simulation are presented. The gamma spectra of the set of basic standard gamma-sources (OSGI) are analyzed for a real detector, and the calculated and actual detection efficiencies are compared. The XGS spectra are analyzed to determine the minimum concentration of the 152Eu radio nuclide in the 137Cs and 60Co mixture. It is shown that the xenon gamma spectrometer is capable of detecting the isotope at concentrations above 40% in the mixture.
Proceedings of SPIE | 2016
Alexander S. Novikov; S. E. Ulin; V. V. Dmitrenko; K. F. Vlasik; Z. M. Uteshev; Alexander E. Shustov; Denis V. Petrenko; Oksana V. Bychkova
Xenon gamma-ray spectrometer for monitoring of 222Rn concentration by means of measurement of its daughter nuclei gamma-ray emission intensity and the main characteristics of this device are presented. Time variations of radon concentration can be interpreted as possible precursors of the Earth’s seismic activity, such as an earthquake, several days prior to these events. The results of the first experiments that were carried out in the Caucasus region of Russia show the possibility of using the described xenon gamma-ray spectrometer for this task.
Proceedings of SPIE | 2016
S. E. Ulin; Alexander S. Novikov; V. V. Dmitrenko; K. F. Vlasik; Z. M. Uteshev; Alexander E. Shustov; Denis V. Petrenko
A gamma-ray spectrometer for radioactive waste sorting is presented. The equipment is based on a new “thin-walled” xenon gamma-ray detector with sensitive volume of 4 liters and a digital electronics unit. Use of the thin wall (0.5 mm of stainless steel covered with fiberglass) provides lower absorption of gamma-rays by the detector’s walls and expansion of the energy range of radiation being registered. The digital electronics unit makes it possible to use the equipment in unfavorable field conditions such as high levels of acoustic influence.
Journal of Physics: Conference Series | 2016
M Smirnova; E Shmanin; A Galavanov; Alexander E. Shustov; S. E. Ulin; K. F. Vlasik; V. V. Dmitrenko; Alexander S. Novikov; A Orlov; Denis V. Petrenko; S Shmurak; Z. M. Uteshev
Results of developing of a gamma-ray detector based on LaBr3(Ce) scintillation crystal for neutron capture therapy are presented. An energy resolution of the detector measured by photomultiplier tube Hamamatsu R6233-100 is showed. It was 2.93% for gamma line 662 keV from a source 137Cs. For radiative capture gamma line of isotope 10B (478 keV) and annihilation line (511 keV) the values were 3.33 and 3.24% respectively. Data analysis of gamma spectra for an estimation of energy resolution threshold required for visual identification gamma lines 478 and 511 keV was made.
Bulletin of the Lebedev Physics Institute | 2015
V. V. Dmitrenko; Phyo Wai Nyunt; K. F. Vlasik; V. M. Grachev; S. S. Grabchikov; S. S. Muravyev-Smirnov; Alexander S. Novikov; Denis V. Petrenko; S. E. Ulin; Z. M. Uteshev; I. V. Chernysheva; Alexander E. Shustov
Protection of scientific equipment aboard spacecrafts against both natural and artificial constant magnetic fields is an urgent problem. Multilayer film electromagnetic shields produced by electrodeposition showed high shielding efficiency during laboratory tests. To test their application prospects under conditions of real space flights, a “Nanomag” scintillation telescope was developed and fabricated. Laboratory tests which demonstrated its operability at magnetic field induction to 4 mT are presented in this paper.
Bulletin of the Lebedev Physics Institute | 2015
S. N. P’ya; K. F. Vlasik; V. M. Grachev; V. V. Dmitrenko; Alexander S. Novikov; Denis V. Petrenko; Alexander E. Shustov; Z. M. Uteshev; S. E. Ulin; I. V. Chernysheva
A xenon gamma spectrometer (XGS) with a sensitive volume of 6 liters is described. Physico-technical characteristics of the gamma spectrometer, determined using radioactive sources of the set of standard spectrometric gamma sources, are presented. Gamma spectra of radioactive waste in a 3.4-m3 container for solid radioactive waste are measured, and isotope activities are determined. The XGS is simulated by the Monte Carlo method using the GEANT4 package. The activities are determined by a combined method with an analysis of experimental spectra and simulated data. It is shown that the XGS has good metrological capabilities for characterizing radioactive waste, including nuclide identification and their activity estimation.