Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Dennis Morgan is active.

Publication


Featured researches published by Dennis Morgan.


Journal of Cardiovascular Electrophysiology | 2010

Impact of pharmacological autonomic blockade on complex fractionated atrial electrograms.

Sébastien Knecht; Matthew Wright; Seiichiro Matsuo; Isabelle Nault; Nicolas Lellouche; Frédéric Sacher; Steven J. Kim; Dennis Morgan; Valtino X. Afonso; Miyazaki Shinzuke; Mélèze Hocini; Jacques Clémenty; Sanjiv M. Narayan; Phillipe Ritter; Pierre Jaïs; Michel Haïssaguerre

Autonomic Blockade During Atrial Fibrillation. Introduction: The influence of the autonomic nervous system on the pathogenesis of complex fractionated atrial electrograms (CFAE) during atrial fibrillation (AF) is incompletely understood. This study evaluated the impact of pharmacological autonomic blockade on CFAE characteristics.


IEEE Transactions on Biomedical Engineering | 2017

Orientation-Independent Catheter-Based Characterization of Myocardial Activation

Don Curtis Deno; Ram Kumar Balachandran; Dennis Morgan; Faiz Ahmad; Stephane Masse; Kumaraswarmy Nanthakumar

Cardiac electrogram (EGM) signals and electrophysiologic (EP) characteristics derived from them such as amplitude and timing are central to the diagnosis and therapeutic management of arrhythmias. Bipolar EGMs are often used but possess polarity and shape dependence on catheter orientation contributing to uncertainty. Objective: We describe a novel method to map cardiac activation that resolves signals into meaningful directions and is insensitive to electrode directional effects. Methods: Multielectrode catheters that span 2- and 3-D space are used to derive local electric field (E-field) signals. A traveling wave model of local EGM propagation motivates a new “omnipolar” reference frame in which to understand EGM E-field signals and provide bipolar component EGMs aligned with these anatomic and physiologic directions. We validate the basis of this technology and determine its accuracy using a saline tank in which we simulate physiologic propagation. Results: Omnipole signals from healthy tissue are nearly free of catheter orientation effects and are constrained by biophysics to consistent morphologies and thus consistent measured amplitudes and timings. Using a 3-D EP mapping system, traveling wave treatment, and omnipolar technology (OT) E-field loops, we derived a new and nearly instantaneous means to determine conduction velocity and activation direction. Conclusion: We describe the basis of OT and validate it with ablation and mapping catheters in a saline tank. Finally, we illustrate OT with signals from live subjects. Significance: OTs novel approach with signal processing and real-time visualization allows for a newly detailed characterization of myocardial activation that is insensitive to catheter orientation.


Circulation-arrhythmia and Electrophysiology | 2017

Relationship Between Distance and Change in Surface ECG Morphology During Pacemapping as a Guide to Ablation of Ventricular Arrhythmias: Implications for the Spatial Resolution of Pacemapping.

Anthony Li; Joseph Samuel Davis; Jeremiah Wierwille; Keith Herold; Dennis Morgan; Elijah R. Behr; Stephen R. Shorofsky; Magdi M. Saba

Background— Pacemapping is used to localize the exit site of ventricular arrhythmia. Although the relationship between distance and change in QRS morphology is its basis, this relationship has not been systematically quantified. Methods and Results— Patients (n=68) undergoing ventricular arrhythmia ablation between March 2012 and July 2013 were recruited. Pacemapping was targeted to areas of voltage >0.5 mV. Linear mixed-effects models were constructed of distance against morphology difference measured by the root mean square error sum across all 12 ECG leads (E12). Forty of 68 (58%) patients had structural heart disease, and 21/40 (53%) patients were ischemic. Nine hundred thirty-five pacing points were collected, generating 6219 pacing site pair combinations (3087 [50%] ventricular bodies, 756 [12%] outflow tract, and 162 [3%] epicardial). In multivariable analysis, increase in E12 was predicted by increasing distance (0.07 per mm; 95% confidence interval 0.07–0.08; P<0.001). Compared with the left ventricle, E12 values were lower in the right ventricle (P=0.037) and left ventricular outflow tract (P<0.001) and higher in left ventricle–right ventricle pairs (P=0.021) and left ventricular epicardium (P=0.08). There was no difference in E12 in the right ventricular outflow tract compared with the right–left ventricular outflow tract (P=0.75) pairs. Structural heart disease or inadvertent pacing in scar was not associated with changes in E12; however, the presence of latency and split potentials were associated with higher and lower E12 values, respectively (P<0.001). Conclusions— A robust positive relationship exists between distance and QRS morphological change when restricting pacing points to areas of voltage >0.5 mV. Significant differences in the spatial resolution of pacemapping exist within the heart.


Europace | 2018

Proof of concept study of a novel pacemapping algorithm as a basis to guide ablation of ventricular arrhythmias

Anthony Li; Joseph Samuel Davis; Alexander Grimster; Jeremiah Wierwille; Keith Herold; Dennis Morgan; Elijah R. Behr; Stephen R. Shorofsky; Magdi Saba

Aims To determine if a software algorithm can use an individualized distance-morphology difference model, built from three initial pacemaps, to prospectively locate the exit site (ES) of ventricular arrhythmias (VA). Methods and results Consecutive patients undergoing ablation of VA from a single centre were recruited. During mapping, three initial pacing points were collected in the chamber of interest and the navigation algorithm applied to predict the ES, which was corroborated by conventional mapping techniques. Thirty-two patients underwent ES prediction over 35 procedures. Structural heart disease was present in 16 (7 ischaemic cardiomyopathy, 9 non-ischaemic cardiomyopathy), median ejection fraction 45% [Interquartile range (IQR) 26]. The remainder had normal hearts. The navigation algorithm was applied to 46 VA (24 left ventricle, 11 right ventricular outflow tract, 5 left ventricular outflow tract, 4 right ventricle, 2 epicardial) and successfully located the site of best pacemap match in 45 within a median area of 196.5 mm2 (IQR 161.3, range 46.6-1288.2 mm2). Conclusions In a diverse population of patients with and without structural heart disease, the ES of VA can be accurately and reliably identified to within a clinically useful target area using a simple software navigation algorithm based on pacemapping.


Archive | 2011

System and Method for Diagnosing Arrhythmias and Directing Catheter Therapies

Valtino X. Afonso; Jiazheng Shi; Steven J. Kim; D. Curtis Deno; Dennis Morgan


Europace | 2014

56Linear relationship between distance and ECG similarity during endocardial and epicardial pacing: application in a novel mapping algorithm for the real-time prediciton of the site of origin of ventricular arrhythmias

Anthony Li; Joseph Samuel Davis; Jeremiah Wierwille; Dennis Morgan; Keith Herold; Stephen R. Shorofsky; Elijah R. Behr; Magdi Saba


Archive | 2010

SYSTEM, ARTICLE OF MANUFACTURE, AND METHOD FOR CHARACTERIZING A MEDICAL DEVICE AND/OR ONE OR MORE SENSORS MOUNTED THEREON

Jiazheng Shi; Valtino X. Afonso; Dennis Morgan; Jeffrey A. Schweitzer


Archive | 2016

SYSTEM AND METHOD FOR ARRHYTHMIA DIAGNOSIS AND CATHETER THERAPIES

Valtino X. Afonso; Shi Jiazheng; Steven J. Kim; D. Curtis Deno; Dennis Morgan


Archive | 2016

Methods and systems for identifying and mapping cardiac activation wavefronts

Dongfeng Han; Valtino X. Afonso; Chin-Ann Yang; Dennis Morgan; Carlo Pappone


Archive | 2015

Methods and Systems for Generating Integrated Substrate Maps for Cardiac Arrhythmias

Wenwen Li; Erhan Erdemir; Valtino X. Afonso; Carlo Pappone; Dennis Morgan

Collaboration


Dive into the Dennis Morgan's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge