Annals of Biomedical Engineering | 2016

Fluid-Structure Interaction Model of a Percutaneous Aortic Valve: Comparison with an In Vitro Test and Feasibility Study in a Patient-Specific Case.

Wei Wu; Desiree Pott; Beniamino Mazza; Tommaso Sironi; Elena Dordoni; Claudio Chiastra; Lorenza Petrini; Giancarlo Pennati; Gabriele Dubini; Ulrich Steinseifer; Simon J. Sonntag; Maximilian Kuetting; Francesco Migliavacca

Transcatheter aortic valve replacement (TAVR) represents an established recent technology in a high risk patient base. To better understand TAVR performance, a fluid–structure interaction (FSI) model of a self-expandable transcatheter aortic valve was proposed. After an in vitro durability experiment was done to test the valve, the FSI model was built to reproduce the experimental test. Lastly, the FSI model was used to simulate the virtual implant and performance in a patient-specific case. Results showed that the leaflet opening area during the cycle was similar to that of the in vitro test and the difference of the maximum leaflet opening between the two methodologies was of 0.42%. Furthermore, the FSI simulation quantified the pressure and velocity fields. The computed strain amplitudes in the stent frame showed that this distribution in the patient-specific case is highly affected by the aortic root anatomy, suggesting that the in vitro tests that follow standards might not be representative of the real behavior of the percutaneous valve. The patient-specific case also compared in vivo literature data on fast opening and closing characteristics of the aortic valve during systolic ejection. FSI simulations represent useful tools in determining design errors or optimization potentials before the fabrication of aortic valve prototypes and the performance of tests.


Asaio Journal | 2012

A novel approach to an anatomical adapted stent design for the percutaneous therapy of tricuspid valve diseases: preliminary experiences from an engineering point of view.

Desiree Pott; Margarita Malasa; Ute Urban; Maximilian Kütting; Yara Safi; Jan Roggenkamp; Ulrich Steinseifer; Nima Hatam; Rüdiger Autschbach; Jan Spillner; Andrea Amerini

Tricuspid valve regurgitation mostly occurs as result of dilation of the right ventricle, secondary to left heart valve diseases. Until recently, little attention has been given to the development of percutaneous therapeutic tools exclusively designed for tricuspid valve disease. A new approach to the interventional therapy of tricuspid regurgitation, in particular, the design of a conceptual new valve-bearing, self-expansible stent, is presented here. A three-dimensional computer model of a right porcine heart was developed to gain a realistic anatomical geometry. The new design consists of two tubular stent elements, one inside the superior vena cava and the other inside the tricuspid valve annulus after being eventually equipped with a biological valve prosthesis, which are connected by struts. Anchoring to the heart structure is provided primarily by the vena cava stent, strengthened by the struts. The stents are designed to be cut from a 10 mm tube and later expanded to their designated diameter. Simulation software analyzing the expansion process with respect to the intended geometrical design is used in an iterative process. A validation of the anatomical geometry and function of the stent design inside a silicone model within in vitro tests and a random porcine heart shows an accurate anatomical fitting.


International Journal for Numerical Methods in Biomedical Engineering | 2018

Fluid-structure interaction of a pulsatile flow with an aortic valve model: A combined experimental and numerical study

Julien Sigüenza; Simon Mendez; Tim A.S. Kaufmann; Simon J. Sonntag; Desiree Pott; Ulrich Steinseifer; Franck Nicoud

The complex fluid-structure interaction problem associated with the flow of blood through a heart valve with flexible leaflets is investigated both experimentally and numerically. In the experimental test rig, a pulse duplicator generates a pulsatile flow through a biomimetic rigid aortic root where a model of aortic valve with polymer flexible leaflets is implanted. High-speed recordings of the leaflets motion and particle image velocimetry measurements were performed together to investigate the valve kinematics and the dynamics of the flow. Large eddy simulations of the same configuration, based on a variant of the immersed boundary method, are also presented. A massively parallel unstructured finite-volume flow solver is coupled with a finite-element solid mechanics solver to predict the fluid-structure interaction between the unsteady flow and the valve. Detailed analysis of the dynamics of opening and closure of the valve are conducted, showing a good quantitative agreement between the experiment and the simulation regarding the global behavior, in spite of some differences regarding the individual dynamics of the valve leaflets. A multicycle analysis (over more than 20 cycles) enables to characterize the generation of turbulence downstream of the valve, showing similar flow features between the experiment and the simulation. The flow transitions to turbulence after peak systole, when the flow starts to decelerate. Fluctuations are observed in the wake of the valve, with maximum amplitude observed at the commissure side of the aorta. Overall, a very promising experiment-vs-simulation comparison is shown, demonstrating the potential of the numerical method.


Interactive Cardiovascular and Thoracic Surgery | 2014

A personalized approach to interventional treatment of tricuspid regurgitation: experiences from an acute animal study

Andrea Amerini; Nima Hatam; Margarita Malasa; Desiree Pott; Lachmandath Tewarie; Peter Isfort; Andreas Goetzenich; Martin Hildinger; Rüdiger Autschbach; Jan Spillner

OBJECTIVES Interventional treatment of tricuspid valve disease has so far received little attention due to the anatomical challenges in a thrombogenic surrounding. In the present study, we present an imaging-based, personalized interventional approach to the therapy of tricuspid regurgitation. METHODS In our porcine model, we used rapid prototyping to build a matrix reproducing the geometry of the right atrium that was previously derived from computer tomography (CT) scans. Over this matrix, a braided nitinol device fitting almost completely the right atrium was crafted. An additional tubular stent component was developed to carry a tissue valve prosthesis. This part was designed to be connectable to the annular portion of the main device. In our feasibility study, the crimped device was implanted via jugular access into the right atrium of 12 pigs and expanded subsequently. Following isolated implantation of the device without the valve-carrying component, further procedures included implantation of the whole composite device, including the mentioned tissue valve. Representing a only feasibility study, all implantations were performed under full bypass and direct sight. On-site visualization was performed by both echocardiography and fluoroscopy. Additional imaging was realized by postoperative CT scans. RESULTS Following implantation, 9 of 12 animals were weaned from cardiopulmonary bypass. Correct positioning of the device and orthodromic blood flow as maintained by the valve prosthesis were demonstrated by echocardiography and fluoroscopy. Postoperative contrast CT evaluation demonstrated proper fitting of the device into the right-sided heart cavities without obstruction of the outflow tract. Autopsy additionally confirmed its correct positioning without major trauma to surrounding structures. CONCLUSIONS We demonstrated the feasibility in principle of a personalized interventional treatment for tricuspid regurgitation using a braided stent, based on individual cardiac imaging, with anchoring forces mainly exerted on the venae cavae and on the inner surface of the right atrium. The design process of this device is a good indicator of the growing potential of an imaging-based personalized simulation and production approach for the treatment of tricuspid valve disease.


Artificial Organs | 2015

Development of a Transcatheter Tricuspid Valve Prosthesis Through Steps of Iterative Optimization and Finite Element Analysis.

Desiree Pott; Maximilian Kütting; Zhaoyang Zhong; Andrea Amerini; Jan Spillner; Rüdiger Autschbach; Ulrich Steinseifer

The development of a transcatheter tricuspid valve prosthesis for the treatment of tricuspid regurgitation (TR) is presented. The design process involves an iterative development method based on computed tomography data and different steps of finite element analysis (FEA). The enhanced design consists of two self-expandable stents, one is placed inside the superior vena cava (SVC) for primary device anchoring, the second lies inside the tricuspid valve annulus (TVA). Both stents are connected by flexible connecting struts (CS) to anchor the TVA-stent in the orthotopic position. The iterative development method includes the expansion and crimping of the stents and CS with FEA. Leaflet performance and leaflet-stent interaction were studied by applying the physiologic pressure cycle of the right heart onto the leaflet surfaces. A previously implemented nitinol material model and a new porcine pericardium material model derived from uniaxial tensile tests were used. Maximum strains/stresses were approx. 6.8% for the nitinol parts and 2.9 MPa for the leaflets. Stent displacement because of leaflet movement was ≤1.8 mm at the commissures and the coaptation height was 1.6-3 mm. This led to an overall good performance of the prosthesis. An anatomic study showed a good anatomic fit of the device inside the human right heart.


Interactive Cardiovascular and Thoracic Surgery | 2018

The flutter-by effect: a comprehensive study of the fluttering cusps of the Perceval heart valve prosthesis

Ali Aljalloud; Mohamed Shoaib; Sandrine Egron; Jessica Arias; Lachmandath Tewarie; Heike Schnoering; Shahram Lotfi; Andreas Goetzenich; Nima Hatam; Desiree Pott; Zhaoyang Zhong; Ulrich Steinseifer; R. Zayat; R. Autschbach

OBJECTIVES Sutureless aortic valve prostheses are gaining popularity due to the substantial reduction in cross-clamp time. In this study, we report our observations on the cusp-fluttering phenomenon of the Perceval bioprosthesis (LivaNova, London, UK) using a combination of technical and medical perspectives. METHODS Between August 2014 and December 2016, a total of 108 patients (69% women) with a mean age of 78 years had aortic valve replacement using the Perceval bioprosthesis (34 combined procedures). All patients underwent transoesophageal echocardiography (TOE) intraoperatively. TOE was performed postoperatively to detect paravalvular leakage and to measure gradients, acceleration time, Doppler velocity indices (Vmax and LVOT/Vmax AV) and effective orifice area indices. In addition, a TOE examination was performed in 21 patients postoperatively. Data were collected retrospectively from our hospital database. RESULTS The retrospective evaluation of the intraoperative TOE examinations revealed consistent fluttering in all patients with the Perceval bioprosthesis. The echocardiographic postoperative measurements showed a mean effective orifice area index of 0.91 ± 0.12 cm2/m2. The overall mean pressure and peak pressure gradients were in a higher range (13.5 ± 5.1 mmHg and 25.5 ± 8.6 mmHg, respectively), whereas acceleration time (62.8 ± 16.4 ms) and Doppler velocity indices (0.43 ± 0.11) were within the normal range according to the American Society of Echocardiography or european association of echocardiography (EAE) guidelines. The 2-dimensional TOE in Motion Mode (M-Mode) that was performed in patients with elevated lactate dehydrogenase (LDH) levels revealed remarkable fluttering of the cusps of the Perceval bioprosthesis. CONCLUSIONS In our study cohort, we observed the fluttering phenomenon in all patients who received the Perceval bioprosthesis, which was correlated with elevated LDH levels and higher pressure gradients.


CMBBE 2016 | 2018

Fluid–Structure Simulation of a Transcatheter Aortic Valve Implantation: Potential Application to Patient-Specific Cases

Wei Wu; Desiree Pott; Claudio Chiastra; Lorenza Petrini; Giancarlo Pennati; Gabriele Dubini; Ulrich Steinseifer; Simon J. Sonntag; Maximilian Kuetting; Francesco Migliavacca

Valve diseases are more and more treated with transcatheter aortic valves. This work is based on an experimental setup with the corresponding fluid–structure interaction model to show the feasibility of performing accurate simulations which is able to capture the main behavior of a transcatheter valve both from structural and fluid dynamic points of view. The application of this methodology to patient-specific cases is also illustrated.


Expert Review of Medical Devices | 2015

Right heart transcatheter valve therapies - a review of prostheses for the pulmonary and tricuspid positions

Maximilian Kuetting; Desiree Pott; Alexander Sedaghat; Yue Ann Ng; Sandrine Egron; Christiane Rosefort; Nikos Werner; Joerg S. Sachweh; Ulrich Steinseifer

Minimally invasive, catheter-based treatment of valvular dysfunction has become an integral part of clinical routine. As left heart valvular disease is much more common and thus commercially of interest, transcatheter solutions for the treatment of aortic and mitral valvular defects were the first to become broadly clinically available, while even today options for the right heart valve are rare. This review looks at innovative attempts at developing effective transcatheter heart valve prostheses for the pulmonary and tricuspid heart valves, details their experience and highlights those that have made their way to application in humans.


Experiments in Fluids | 2013

Analysis of basic flow regimes in a human airway model by stereo-scanning PIV

Thomas Soodt; Desiree Pott; Michael Klaas; Wolfgang Schröder


Journal of Medical Devices-transactions of The Asme | 2017

Simplified Multistage Computational Approach to Assess the Fatigue Behavior of a Niti Transcatheter Aortic Valve During In Vitro Tests: A Proof-of-Concept Study

Lorenza Petrini; Elena Dordoni; Dario Allegretti; Desiree Pott; Maximilian Kütting; Francesco Migliavacca; Giancarlo Pennati

Collaboration


Dive into the Desiree Pott's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Nima Hatam

RWTH Aachen University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge