Devon D. Goetz
University of Iowa
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Devon D. Goetz.
Journal of Bone and Joint Surgery, American Volume | 2000
John J. Callaghan; Jay C. Albright; Devon D. Goetz; Jason P. Olejniczak; Richard C. Johnston
Background: This report presents the results of the senior authors initial twenty-five-year experience with the use of Charnley total hip arthroplasty with cement. The purpose of this paper was to evaluate the long-term results of total hip arthroplasty. Methods: Between July 1970 and April 1972, the senior author (R. C. J.) performed 330 Charnley total hip replacements with cement using a hand-packing cement technique in 262 patients. Fifty-one patients (sixty-two hips) who were alive at least twenty-five years postoperatively were evaluated from a clinical standpoint with use of a standard-terminology questionnaire. The average age of this group at the time of surgery was fifty-six years (range, thirty-five to seventy-one years) compared with sixty-five years (range, twenty-one to eighty-nine years) for the entire group. All patients were evaluated for radiographic changes at the time of their most recent follow-up. Of the fifty-one patients (sixty-two hips) who were alive at least twenty-five years postoperatively, thirty-one (thirty-six hips) had a follow-up radiograph made at a minimum of twenty-five years after the surgery. The average duration of radiographic follow-up for the fifty-one patients was 22.7 years (range, two to twenty-seven years). Results: Of the sixty-two hips in the fifty-one patients who were alive at least twenty-five years postoperatively, fourteen (23 percent) had been revised. Three (5 percent) had the revision because of loosening with infection; eleven (18 percent), because of aseptic loosening; and none, because of dislocation. The prevalence of revision due to aseptic loosening of the acetabular component in all 316 hips (excluding those that were lost to follow-up or that were revised for infection or dislocation) was 6 percent (eighteen hips), whereas the prevalence in the fifty-nine hips (excluding the three revised for infection) in the patients who were alive at least twenty-five years after the arthroplasty was 15 percent (nine hips). The prevalence of revision because of aseptic loosening of the femoral component in all 316 hips was 3 percent (nine hips), and the prevalence in the fifty-nine hips in the living patients was 7 percent (four hips). In the group of living patients, osteolysis occurred in Gruen zone 1 or 7 in thirty-three hips and in Gruen zones 2 through 6 in two hips. Ballooning acetabular osteolysis occurred in five hips. Of the 327 hips for which the outcome was known after a minimum of twenty-five years, 295 (90 percent) had retained the original implants until the patient died or until the most recent follow-up examination. Of the sixty-two hips in patients who lived for at least twenty-five years after the surgery, forty-eight (77 percent) had retained the original prosthesis. Conclusions: Our follow-up study at twenty-five years following Charnley total hip arthroplasty with cement demonstrates the durability of the results of the procedure. These results should provide a means for comparison with the results of newer cementing techniques as well as those associated with newer cemented and cementless hip designs.
Clinical Orthopaedics and Related Research | 1999
Matthew W. Squire; John J. Callaghan; Devon D. Goetz; Patrick M. Sullivan; Richard C. Johnston
One hundred forty Marmor cemented unicompartmental knee replacements were inserted in 103 patients between 1975 and 1982. Fifty-two patients were women and 51 were men. One hundred twenty-five were medial compartment knee replacements and 15 were lateral knee replacements. At minimum 15 year followup 34 patients with 48 knee replacements were living; only four patients with four knee replacements were lost to followup. Average preoperative and final followup Hospital for Special Surgery knee scores were 57 and 82 points, respectively for the knees of living patients. Average preoperative and final followup Knee Society clinical and Knee Society functional scores were 31 and 42, and 85 and 71 points, respectively. For all knees, 10.2% (14 knees) were revised [4.4% (six knees) for tibial loosening, 5.1% (seven knees) for disease progression, and .7% (one knee) for pain]. For patients living 15 years, 12.5% (six knees) were revised [2.1% (one knee) for tibial loosening, and 10.4% (five knees) for disease progression]. Revision for failure of fixation of these unicompartmental replacements was comparable with that reported for fixed bearing total knee replacement. Disease progression (46%; 62 of 136 knees) and tibial subsidence with wear (10.4%; 15 of 136 knees, five of which required revision) were the major long term problems in this group of patients.
Journal of Bone and Joint Surgery, American Volume | 2005
John J. Callaghan; Christopher W. Wells; Steve S. Liu; Devon D. Goetz; Richard C. Johnston
We previously evaluated 119 consecutive total knee arthroplasties that were performed in eighty-six patients with use of the cemented LCS (low contact stress) rotating-platform system with an all-polyethylene patellar component. The average age of the patients at the time of surgery was seventy years (range, thirty-seven to eighty-eight years). The purpose of this study was to report the updated results at a minimum follow-up of fifteen years. Thirty-seven patients (fifty-three knees) were living, and no patient was lost to follow-up. No knee was revised because of loosening, osteolysis, or wear. Three knees required a reoperation (two for periprosthetic fractures and one for infection). No component was revised as a part of the reoperations. Osteolysis was present in three knees. No knee had radiographic signs of component loosening, and there were no dislocated bearings. The average range of motion was from 1 degrees of extension to 105 degrees of flexion. The average clinical and functional Knee Society scores were 43 and 49, respectively, at the preoperative evaluation and 85 and 58 at the time of the final follow-up. We concluded that the cemented LCS rotating-platform knee performed well, with durable clinical and radiographic results at a minimum follow-up of fifteen years.
Journal of Bone and Joint Surgery, American Volume | 2000
John J. Callaghan; Matt W. Squire; Devon D. Goetz; Patrick M. Sullivan; Richard C. Johnston
Background: Although the LCS (low contact stress) rotating-platform mobile-bearing knee replacement has been used extensively, there have been few intermediate or long-term clinical and radiographic follow-up studies evaluating the device. The purpose of this study was to report the nine to twelve-year results of a consecutive series of patients who had a primary total knee replacement performed with this device. Methods: Between November 1985 and November 1988, the senior author (R. C. J.) performed 119 consecutive total knee arthroplasties in eighty-six patients with LCS rotating-platform femoral and tibial components and a Townley all-polyethylene dome patellar component. All components were fixed with cement. The average age of the patients at the time of the operation was seventy years (range, thirty-seven to eighty-eight years). Fifty-two patients (seventy-six knees) were female, and thirty-four patients (forty-three knees) were male. The patients were evaluated with clinical knee ratings and radiographic analysis nine to twelve years following the knee replacement. Results: At the time of the nine to twelve-year follow-up, sixty-four patients (eighty-six knees) were alive, eighteen patients (twenty-eight knees) had died, and four patients (five knees) had been lost to follow-up. Of the 114 knees in the eighty-two patients for whom the final outcome was known, none required a reoperation and none had a dislocation of the mobile-bearing prosthesis. For the forty-five patients (sixty-six knees) who returned for final clinical and radiographic follow-up examinations at nine to twelve years, the average clinical and functional Knee Society ratings were 30 points (range, 2 to 70 points) and 44 points (range, 0 to 80 points) preoperatively and 90 points (range, 63 to 102 points) and 75 points (range, 30 to 100 points) at the final follow-up evaluation. The average Hospital for Special Surgery knee rating was 57 points (range, 28 to 80 points) preoperatively and 84 points (range, 59 to 97 points) at the final follow-up evaluation. The average active range of knee flexion was from 0 degrees (range, 0 to 10 degrees) to 102 degrees (range, 15 to 120 degrees) at the final follow-up evaluation. Seven of the sixty-six knees were painful anteriorly. There was no periprosthetic osteolysis and no evidence of loosening on follow-up radiographs. Conclusions: After nine to twelve years of follow-up, the cemented LCS rotating-platform knee replacement was found to be performing well, with durable clinical and radiographic results.
Journal of Bone and Joint Surgery, American Volume | 1998
John J. Callaghan; Erin E. Forest; Jason P. Olejniczak; Devon D. Goetz; Richard C. Johnston
We evaluated the results twenty to twenty-five years after ninety-three consecutive, non-selected Charnley total hip arthroplasties performed with cement by the senior one of us in sixty-nine patients who were less than fifty years old at the time of the procedure. Seventy of the seventy-two hips in the living patients were followed radiographically for at least twenty years. Twenty-seven hips (29 per cent) had a revision or a resection of the prosthesis during the follow-up period. The revision or the resection was performed because of aseptic loosening in twenty-one hips (23 per cent), infection in four (4 per cent), dislocation in one (1 per cent), and fracture of the femur in one. Eighteen acetabular components (19 per cent) and five femoral components (5 per cent) were revised because of aseptic loosening, and an additional fourteen acetabular components (15 per cent) and seven femoral components (8 per cent) demonstrated definite or probable radiographic loosening. The present study demonstrates the long-term durability of total hip arthroplasty performed with cement in an active population of patients. The fixation of the femoral component was found to perform better than that of the acetabular component at twenty to twenty-five years after the procedure.
Journal of Bone and Joint Surgery, American Volume | 2004
John J. Callaghan; Jesse E. Templeton; Steve S. Liu; Douglas R. Pedersen; Devon D. Goetz; Patrick M. Sullivan; Richard C. Johnston
The purpose of the current study was to update the results of a prospective, single-surgeon series of primary Charnley total hip arthroplasties performed with cement. This investigation is one of the first studies in which hips treated with total hip arthroplasty with cement were followed for a minimum of thirty years. Twenty-seven patients (thirty-four [10.3%] of the hips in the initial study group) were alive at a minimum of thirty years postoperatively. These patients served as the focus of the present study. Revision because of aseptic loosening of the acetabular component was performed in 7.3% (twenty-three) of the hips from the original study group (excluding those revised because of infection or dislocation) and 26% (eight) of the hips in the living cohort. Revision because of aseptic loosening of the femoral component was performed in 3.2% (ten) of the hips from the original study group (excluding those revised because of infection or dislocation) and 10% (three) of the hips in the living patients. Since the twenty-five-year review, three hips were revised (one because of acetabular loosening, one because of femoral loosening, and one because of instability). This end-result study demonstrated the remarkable durability of cemented Charnley total hip replacements over a span of three decades, with 88% of the original prostheses intact at the time of the final follow-up or at the patients death.
Journal of Bone and Joint Surgery, American Volume | 2002
Michael R. O'rourke; John J. Callaghan; Devon D. Goetz; Patrick M. Sullivan; Richard C. Johnston
Background: Most intermediate and long-term studies of cemented posterior-cruciate-substituting total knee prostheses were performed with nonmodular tibial components. The purpose of this study was to evaluate the intermediate-term results of posterior-cruciate-substituting total knee arthroplasties in which a cemented modular tibial component had been used, with a particular focus on evaluating the prevalence of radiographic osteolysis.Methods: Between 1992 and 1995, 176 consecutive primary total knee arthroplasties with use of the Insall-Burstein II system were performed in 134 patients at our institution. A modular metal-backed tibial component was inserted in 145 knees, and an all-polyethylene tibial component of the same design was inserted in thirty-one. Standard-terminology questionnaires were completed or Knee Society and The Hospital for Special Surgery scores were determined preoperatively and at the time of final follow-up, at an average of 6.4 years (range, 5.0 to 7.9 years). Initial postoperative radiographs were compared with those made at the time of final follow-up to assess component position, wear, radiolucent lines, and osteolysis.Results: Ninety-two patients (128 knees) treated with the modular tibial component were alive at the time of final follow-up. No patient was lost to follow-up. Radiographs were available for 105 knees (82%). Three knees had been revised because of instability or infection; none had been revised because of loosening or osteolysis. The mean Knee Society clinical and functional scores were 85 points (range, 41 to 100 points) and 79 points (range, 30 to 100 points), respectively, at the time of final follow-up. According to The Hospital for Special Surgery score, 94% of the knees had a good or excellent result. Knee flexion averaged 113° (range, 90° to 130°) at the time of final follow-up. Osteolysis was present in seventeen (16%) of the knees with radiographic follow-up. Osteolysis did not develop in any knee in which an all-polyethylene tibial component had been used. Two knees (in one patient) were revised because of osteolytic lesions found at the time of follow-up for the study. Both of these knees had anterior wear of the tibial post due to impingement and backside tibial polyethylene wear.Conclusions: Modular Insall-Burstein II total knee prostheses were found to function well after five to eight years of follow-up. However, the high prevalence of osteolysis in patients who had good or excellent clinical scores is worrisome. Particular attention should be paid to preventing flexion of the femoral component, posterior slope of the tibial component, or hyperextension of the knee when posterior-cruciate-substituting total knee arthroplasty is performed. We also recommend routine follow-up radiographs after all total joint arthroplasties to detect asymptomatic osteolytic changes.
Journal of Bone and Joint Surgery, American Volume | 2014
Jay D. Keener; John J. Callaghan; Devon D. Goetz; Douglas R. Pederson; Patrick M. Sullivan; Richard C. Johnston
Abstract: We report the updated results for a previously evaluated cohort of patients who were less than fifty years old when they underwent Charnley total hip arthroplasty with cement. The original cohort consisted of ninety-three total hip arthroplasties performed in sixty-nine patients. The patients were followed for a minimum of twenty-five years after surgery or until death. The present report describes the findings of the radiographic and functional follow-up, which was performed for forty-two of the forty-three living patients. At the time of the latest follow-up, twenty-nine (31%) of the ninety-three total hip replacements had been revised or removed. Eighteen acetabular and five femoral components were revised secondary to aseptic loosening. The combined prevalence of radiographic failure or revision because of aseptic loosening was 13% for the femoral components and 34% for the acetabular components. Comorbid medical conditions significantly hindered results on each functional subscale (p < 0.05). This study demonstrates the durability of cemented total hip replacements in a young patient population. Sixty-nine percent of the original hip replacements were functioning well at the latest follow-up examination or at the time of death, and only 5% required more than one revision arthroplasty. Level of Evidence: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.We report the updated results for a previously described cohort of patients who were less than fifty years old at the time of the index Charnley total hip arthroplasty with cement. The original cohort consisted of ninety-three consecutive hips in sixty-nine patients. The patients were followed for a minimum of thirty-five years after surgery or until death. At the latest follow-up evaluation, there were forty-one total hip replacements (44%) in thirty-two living patients. Thirty-four (37%) of the ninety-three total hip replacements in the original cohort had been revised or removed. Twenty acetabular (22%) and seven femoral (8%) components had been revised for aseptic loosening. Since the twenty-five-year follow-up, the average six-minute-walk distance decreased from 395 m to 171 m, and this decrease correlated with increasing comorbidity. This study demonstrates the durability of cemented total hip replacements in a young patient population. Although 63% (fifty-nine) of the ninety-three original hip replacements were functioning at the latest follow-up or at the time of death, a significant decrease in activity level was seen over time (p < 0.001). Of the forty-one original implants in the patients who were alive at the time of the thirty-five-year follow-up, only 46% (nineteen) were retained.
Clinical Orthopaedics and Related Research | 2002
John J. Callaghan; Michael R. O'rourke; Devon D. Goetz; Thomas P. Schmalzried; Pat Campbell; Richard C. Johnston
Reports of posterior-stabilized total knee replacements have shown excellent clinical success. However, tibial post-femoral cam impingement has been seen in modular component retrievals. This finding has been associated with transmission of rotational forces to the modular tray-polyethylene interface with subsequent backside polyethylene wear and the development of osteolysis. Femoral cam-tibial post designs that allow hyperextension and limit rotational constraint may minimize this impingement. Technical considerations including the avoidance of femoral component flexion and posterior tibial slope will minimize anterior tibial post impingement.
Journal of Bone and Joint Surgery, American Volume | 1997
Steven M. Madey; John J. Callaghan; Jason P. Olejniczak; Devon D. Goetz; Richard C. Johnston
Three hundred and fifty-seven consecutive Charnley total hip arthroplasties were performed in 320 patients with use of a so-called second-generation technique of cementing between July 1976 and June 1978. This technique includes use of a distal femoral intramedullary cement plug, hand-mixing of the cement, and use of a cement gun to deliver the cement into the femoral canal in a retrograde fashion. At the time of the latest follow-up evaluation, a minimum of fifteen years after the arthroplasty, 130 patients (142 hips) were still alive, 189 patients (214 hips) had died, and one patient (one hip) had been lost to follow-up. A radiograph was made for 116 (82 per cent) of the 142 hips in the 130 surviving patients. Of the 356 hips that had not been lost to follow-up, thirty-three (9 per cent) had had a revision and two (1 per cent), a Girdlestone resection arthroplasty during the follow-up period. Nineteen hips (5 per cent) were revised because of aseptic loosening of the femoral or acetabular component, or both (two hips); seven (2 per cent), because of loosening with infection; and seven (2 per cent), because of dislocation. The two resection arthroplasties were performed because of loosening with infection; both were done in patients who died before the time of the latest follow-up evaluation. Of the 142 hips in the 130 patients who were alive at a minimum of fifteen years, twenty-two (15 per cent) had been revised: fifteen (11 per cent), because of aseptic loosening; three (2 per cent), because of loosening with infection; and four (3 per cent), because of dislocation. Revision of the femoral component because of aseptic loosening (excluding components that were revised because of dislocation or infection) was performed in four (1 per cent) of the entire series of 356 hips and in three (2 per cent) of the 142 hips in the 130 patients who survived for at least fifteen years. Two of the 356 hips and two of the 142 hips had aseptic loosening of the acetabular as well as the femoral component at the time of the revision. Loosening of the femoral component, defined as aseptic loosening leading to revision or as definite or probable radiographic loosening, occurred in ten (3 per cent) of the 356 hips and in six (5 per cent) of the 116 hips for which radiographs were made at a minimum of fifteen years. The acetabular component was revised because of aseptic loosening in seventeen (5 per cent) of the entire series of 356 hips and in fourteen (10 per cent) of the 142 hips in the 130 patients who survived for at least fifteen years. The acetabular component loosened without infection in forty-one (12 per cent) of the 356 hips and in twenty-six (22 per cent) of the 116 hips for which radiographs were made at a minimum of fifteen years. In two of these patients, the femoral component was also revised. Thus, of the entire series of 356 hips, two had a revision of the femoral component alone because of aseptic loosening; fifteen, a revision of the acetabular component alone; and two, a revision of both components. Of the 142 hips in the 130 patients who survived for at least fifteen years, one was revised for loosening of the femoral component alone; twelve, for loosening of the acetabular component alone; and two, for loosening of both components. These findings demonstrate long-term durability of fixation of the femoral component but less reliable fixation of the acetabular component, even when the surgeon is experienced and improved techniques of cementing are used.