Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Diane A. Blake is active.

Publication


Featured researches published by Diane A. Blake.


Biosensors and Bioelectronics | 2001

Antibody-based sensors for heavy metal ions

Diane A. Blake; R. Mark Jones; Robert C. Blake; Andrey R. Pavlov; Ibrahim A. Darwish; Haini Yu

Competitive immunoassays for Cd(II), Co(II), Pb(II) and U(VI) were developed using identical reagents in two different assay formats, a competitive microwell format and an immunosensor format with the KinExA 3000. Four different monoclonal antibodies specific for complexes of EDTA-Cd(II), DTPA-Co(II), 2,9-dicarboxyl-1,10-phenanthroline-U(VI), or cyclohexyl-DTPA-Pb(II) were incubated with the appropriate soluble metal-chelate complex. In the microwell assay format, the immobilized version of the metal-chelate complex was present simultaneously in the assay mixture. In the KinExA format, the antibody was allowed to pre-equilibrate with the soluble metal-chelate complex, then the incubation mixture was rapidly passed through a microcolumn containing the immobilized metal-chelate complex. In all four assays, the KinExA format yielded an assay with 10-1000-fold greater sensitivity. The enhanced sensitivity of the KinExA format is most likely due to the differences in the affinity of the monoclonal antibodies for the soluble versus the immobilized metal-chelate complex. The KinExA 3000 instrument and the Cd(II)-specific antibody were used to construct a prototype assay that could correctly assess the concentration of cadmium spiked into a groundwater sample. Mean analytical recovery of added Cd(II) was 114.25+/-11.37%. The precision of the assay was satisfactory; coefficients of variation were 0.81-7.77% and 3.62-14.16% for within run and between run precision, respectively.


Journal of Biological Chemistry | 1996

METAL BINDING PROPERTIES OF A MONOCLONAL ANTIBODY DIRECTED TOWARD METAL-CHELATE COMPLEXES

Diane A. Blake; Pampa Chakrabarti; Mehraban Khosraviani; Frank Hatcher; Connie M. Westhoff; Peter Goebel; Dwane E. Wylie; Robert C. Blake

A monoclonal antibody that recognizes cadmium-EDTA complexes has been produced by the injection of BALB/c mice with a metal-chelate complex covalently coupled to a carrier protein. The ability of purified antibody to recognize 16 different metal-EDTA complexes was assessed by measuring equilibrium binding constants using a KinExA™ immunoassay instrument. The antibody bound to cadmium- and mercury-EDTA complexes with equilibrium dissociation constants of 21 and 26 nM, respectively. All other metal-EDTA complexes tested, including those of Mn(II), In(III), Ni(II), Zn(II), Co(II), Cu(II), Ag(I), Fe(III), Pb(II), Au(III), Tb(III), Ga(III), Mg(II), and Al(III) bound with affinities from 20- to 40,000-fold less than that determined for the cadmium-EDTA complex. With the exception of mercury and magnesium, the binding of divalent metal-chelate complexes was well-correlated with the size of the metal ion. The amino acid sequences of the heavy and light chain variable regions were deduced from polymerase chain reaction-amplified regions of the corresponding genes and subsequently used to construct molecular models of the antigen binding region. The key residue for cadmium binding in the model for 2A81G5 appeared to be histidine 96 in the heavy chain.


Environmental Health Perspectives | 2005

Serum Cadmium Levels in Pancreatic Cancer Patients from the East Nile Delta Region of Egypt

Alison M. Kriegel; Amr S. Soliman; Qing Zhang; Nabih El-Ghawalby; Farouk A. Ezzat; Ahmed Soultan; Mohamed Abdel-Wahab; Omar Fathy; Gamal Ebidi; Nadia Bassiouni; Stanley R. Hamilton; James L. Abbruzzese; Michelle Lacey; Diane A. Blake

The northeast Nile Delta region exhibits a high incidence of early-onset pancreatic cancer. It is well documented that this region has one of the highest levels of pollution in Egypt. Epidemiologic studies have suggested that cadmium, a prevalent pollutant in the northeast Nile Delta region, plays a role in the development of pancreatic cancer. Objective: We aimed to assess serum cadmium levels as markers of exposure in pancreatic cancer patients and noncancer comparison subjects from the same region in Egypt. Design and Participants: We assessed serum cadmium levels of 31 newly diagnosed pancreatic cancer patients and 52 hospital comparison subjects from Mansoura, Egypt. Evaluation/Measurements: Serum cadmium levels were measured using a novel immunoassay procedure. Results: We found a significant difference between the mean serum cadmium levels in patients versus comparison subjects (mean ± SD, 11.1 ± 7.7 ng/mL vs. 7.1 ± 5.0 ng/mL, respectively; p = 0.012) but not in age, sex, residence, occupation, or smoking status. The odds ratio (OR) for pancreatic cancer risk was significant for serum cadmium level [OR = 1.12; 95% confidence interval (CI), 1.04–1.23; p = 0.0089] and farming (OR = 3.25; 95% CI, 1.03–11.64; p = 0.0475) but not for age, sex, residence, or smoking status. Conclusions: The results from this pilot study suggest that pancreatic cancer in the East Nile Delta region is significantly associated with high levels of serum cadmium and farming. Relevance to Clinical Practice/Public Health: Future studies should further investigate the etiologic relationship between cadmium exposure and pancreatic carcinogenesis in cadmium-exposed populations.


Analytical Chemistry | 2013

All-integrated and highly sensitive paper based device with sample treatment platform for Cd2+ immunodetection in drinking/tap waters.

Adaris M. López_Marzo; Josefina Pons; Diane A. Blake; Arben Merkoçi

Nowadays, the development of systems, devices, or methods that integrate several process steps into one multifunctional step for clinical, environmental, or industrial purposes constitutes a challenge for many ongoing research projects. Here, we present a new integrated paper based cadmium (Cd(2+)) immunosensing system in lateral flow format, which integrates the sample treatment process with the analyte detection process. The principle of Cd(2+) detection is based on competitive reaction between the cadmium-ethylenediaminetetraacetic acid-bovine serum albumin-gold nanoparticles (Cd-EDTA-BSA-AuNP) conjugate deposited on the conjugation pad strip and the Cd-EDTA complex formed in the analysis sample for the same binding sites of the 2A81G5 monoclonal antibody (mAb), specific to Cd-EDTA but not Cd(2+) free, which is immobilized onto the test line. This platform operates without any sample pretreatment step for Cd(2+) detection thanks to an extra conjugation pad that ensures Cd(2+) complexation with EDTA and interference masking through ovalbumin (OVA). The detection and quantification limits found for the device were 0.1 and 0.4 ppb, respectively, these being the lowest limits reported up to now for metal sensors based on paper. The accuracy of the device was evaluated by addition of known quantities of Cd(2+) to different drinking water samples and subsequent Cd(2+) content analysis. Sample recoveries ranged from 95 to 105% and the coefficient of variation for the intermediate precision assay was less than 10%. In addition, the results obtained here were compared with those obtained with the well-established inductively coupled plasma emission spectroscopy (ICPES) and the analysis of certificate standard samples.


Analytica Chimica Acta | 1998

Immunoassays for metal ions

Diane A. Blake; Robert C. Blake; Mehraban Khosraviani; Andrey R. Pavlov

Abstract Antibodies that recognize chelated forms of metal ions have been used to construct immunoassays for Cd(II), Hg(II), Pb(II), and Ni(II). In this paper, the format of these immunoassays is described and the binding properties of three monoclonal antibodies directed towards metal–chelate complexes are reviewed.


Biosensors and Bioelectronics | 2013

High sensitive gold-nanoparticle based lateral flow Immunodevice for Cd2+ detection in drinking waters

Adaris M. López_Marzo; Josefina Pons; Diane A. Blake; Arben Merkoçi

In this work for first time a lateral flow immunosensor device (LFID) for Cd(2+) determination in drinking and tap waters using the Cd-EDTA-BSA-AuNP conjugate as signal producer tool is introduced. The principle of working is based on competitive reaction between the Cd-EDTA-BSA-AuNP conjugate deposited on the conjugation pad strip and the Cd-EDTA complex formed in the analysis sample for the same binding sites of the 2A81G5 monoclonal antibody, specific to Cd-EDTA but not Cd(2+) free, which is immobilized onto the test line. The device has a large response range within 0.4-2000ppb, being the linear response between 0.4 and 10ppb. The quantification and detection limits of 0.4 and 0.1ppb, respectively, represent the lowest ones reported so far for paper based metal sensors. The obtained detection limit is 50 times lower than the maximum contamination level required for drinking water. Here we also show a new option for increasing the sensibility in the LFDs with competitive format, through the decreasing in concentrations of the Cd-EDTA-BSA-AuNP conjugate deposited in the conjugation strip and the mAbs deposited in the test and control zones until to reach optimized concentrations. It is an important result take into account that the increase in sensibility is one of the challenges in the field of LFD sensors, where are focused many of the ongoing researches. In addition, a specificity study of the device for several metal interferences, where potential metal interferences are masked with the use of the EDTA and OVA optimized concentrations, is presented too.


Archives of Ophthalmology | 2009

Creation of a Drug-Coated Glaucoma Drainage Device Using Polymer Technology: In Vitro and In Vivo Studies

Nurettin Sahiner; Daniel Kravitz; Rabah Qadir; Diane A. Blake; Salima Haque; Vijay T. John; Curtis E. Margo; Ramesh S. Ayyala

OBJECTIVE To create and test a slow-release antifibrotic drug-coated glaucoma drainage device using in vitro and in vivo experiments. METHODS A slow-release device incorporating mitomycin C in poly(2-hydroxyethyl methacrylate) disks was developed using redox-polymerization techniques. A standardized preparation of this drug delivery device was attached to the Ahmed glaucoma valve (model FP7; New World Medical, Inc, Rancho Cucamonga, California). Semicircular disks (5 x 6 mm) of P(HEMA)-mitomycin C containing varying concentrations of mitomycin C per gram dry weight of the gel were attached to the lower half of an Ahmed glaucoma valve plate. Water was pumped through the modified Ahmed glaucoma valve at a rate comparable to that of aqueous humor outflow, and mitomycin C release was measured. Modified and unmodified Ahmed glaucoma valves were implanted in a rabbit model, and drug release and fibrosis were assessed after 3 months. RESULTS The P(HEMA)-mitomycin C device released mitomycin C in vitro over 1 to 2 weeks. Studies in rabbits revealed that mitomycin C was released from the disks during the 3-month implantation. Histologic analysis demonstrated a significant reduction in inflammatory reaction and fibrosis in the resulting blebs. CONCLUSION Our slow-release drug-coated glaucoma drainage device decreased fibrosis and inflammation in the resulting bleb in a rabbit model. CLINICAL RELEVANCE This device could reduce the failure rate of glaucoma drainage devices.


ACS Applied Materials & Interfaces | 2012

Highly Porous Acrylonitrile-Based Submicron Particles for UO22+ Absorption in an Immunosensor Assay

Nurettin Sahiner; Haini Yu; Grace Tan; Jibao He; Vijay T. John; Diane A. Blake

Our laboratory has previously reported an antibody-based assay for hexavalent uranium (UO(2)(2+)) that could be used on-site to rapidly assess uranium contamination in environmental water samples (Melton, S. J.; et al. Environ. Sci. Technol. 2009, 43, 6703-6709). To extend the utility of this assay to less-characterized sites of uranium contamination, we required a uranium-specific adsorbent that would rapidly remove the uranium from groundwater samples, while leaving the concentrations of other ions in the groundwater relatively unaltered. This study describes the development of hydrogel particles containing amidoxime groups that can rapidly and selectively facilitate the uptake of uranyl ions. A miniemulsion polymerization technique using SDS micelles was employed for the preparation of the hydrogel as linked submicrometer particles. In polymerization, acrylonitrile was used as the initial monomer, ethylene glycol dimethacrylate as the crosslinker and 2-hydroxymethacrylate, 1-vinyl-2-pyrrolidone, acrylic acid, or methacrylic acid were added as co-monomers after the initial seed polymerization of acrylonitrle. The particles were characterized by transmission electron spectroscopy, scanning electron microscopy (SEM) and cryo-SEM. The amidoximated particles were superior to a commercially available resin in their ability to rapidly remove dissolved UO(2)(2+) from spiked groundwater samples.


Environmental Health Perspectives | 2013

Evaluation of Polycyclic Aromatic Hydrocarbons Using Analytical Methods, Toxicology, and Risk Assessment Research: Seafood Safety after a Petroleum Spill as an Example

Jeffrey K. Wickliffe; Edward B. Overton; Scott Frickel; Jessi L. Howard; Mark J. Wilson; Bridget R. Simon; Stephen Echsner; Daniel Nguyen; David Gauthe; Diane A. Blake; Charles A. Miller; Cornelis J. Elferink; Shakeel Ansari; Harshica Fernando; Edward J. Trapido; Andrew S. Kane

Background: Polycyclic aromatic hydrocarbons (PAHs) are abundant and widespread environmental chemicals. They are produced naturally and through man-made processes, and they are common in organic media, including petroleum. Several PAHs are toxic, and a subset exhibit carcinogenic activity. PAHs represent a range of chemical structures based on two or more benzene rings and, depending on their source, can exhibit a variety of side modifications resulting from oxygenation, nitrogenation, and alkylation. Objectives: Here we discuss the increasing ability of contemporary analytical methods to distinguish not only different chemical structures among PAHs but also their concentrations in environmental media. Using seafood contamination following the Deepwater Horizon accident as an example, we identify issues that are emerging in the PAH risk assessment process because of increasing analytical sensitivity for individual PAHs, and we describe the paucity of toxicological literature for many of these compounds. Discussion: PAHs, including the large variety of chemically modified or substituted PAHs, are naturally occurring and may constitute health risks if human populations are exposed to hazardous levels. However, toxicity evaluations have not kept pace with modern analytic methods and their increased ability to detect substituted PAHs. Therefore, although it is possible to measure these compounds in seafood and other media, we do not have sufficient information on the potential toxicity of these compounds to incorporate them into human health risk assessments and characterizations. Conclusions: Future research efforts should strategically attempt to fill this toxicological knowledge gap so human health risk assessments of PAHs in environmental media or food can be better determined. This is especially important in the aftermath of petroleum spills. Citation: Wickliffe J, Overton E, Frickel S, Howard J, Wilson M, Simon B, Echsner S, Nguyen D, Gauthe D, Blake D, Miller C, Elferink C, Ansari S, Fernando H, Trapido E, Kane A. 2014. Evaluation of polycyclic aromatic hydrocarbons using analytical methods, toxicology, and risk assessment research: seafood safety after a petroleum spill as an example. Environ Health Perspect 122:6–9; http://dx.doi.org/10.1289/ehp.1306724


Biomatter | 2012

In vitro degradation and release characteristics of spin coated thin films of PLGA with a "breath figure" morphology.

Thiruselvam Ponnusamy; Louise B. Lawson; Lucy C. Freytag; Diane A. Blake; Ramesh S. Ayyala; Vijay T. John

Poly (lactic-co-glycolic acid) (PLGA) coatings on implant materials are widely used in controlled drug delivery applications. Typically, such coatings are made with non-porous films. Here, we have synthesized a thin PLGA film coating with a highly ordered microporous structure using a simple and inexpensive water templating “breath figure” technique. A single stage process combining spin coating and breath figure process was used to obtain drug incorporated porous thin films. The films were characterized by scanning electron microscope (SEM) to observe the surface and bulk features of porosity and also, degradation pattern of the films. Moreover, the effect of addition of small amount of poly (ethylene glycol) (PEG) into PLGA was characterized. SEM analysis revealed an ordered array of ~2 µm sized pores on the surface with the average film thickness measured to be 20 µm. The incorporation of hydrophilic poly (ethylene glycol) (PEG) enhances pore structure uniformity and facilitates ingress of water into the structure. A five week in vitro degradation study showed a gradual deterioration of the breath figure pores. During the course of degradation, the surface pore structure deteriorates to initially flatten the surface. This is followed by the formation of new pinprick pores that eventually grow into a macroporous film prior to film breakup. Salicylic acid (highly water soluble) and Ibuprofen (sparingly water soluble) were chosen as model drug compounds to characterize release rates, which are higher in films of the breath figure morphology rather than in non-porous films. The results are of significance in the design of biodegradable films used as coatings to modulate delivery.

Collaboration


Dive into the Diane A. Blake's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Robert C. Blake

Xavier University of Louisiana

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge