Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Dilraj Singh is active.

Publication


Featured researches published by Dilraj Singh.


Current Medical Research and Opinion | 2010

Characteristics of a capsule based dry powder inhaler for the delivery of indacaterol

Richard Pavkov; Stefan Mueller; Katrin Fiebich; Dilraj Singh; Frank Stowasser; Giovanni Pignatelli; Benoît Walter; Dominik Ziegler; Mukul Dalvi; Juergen Dederichs; Ilse Rietveld

Abstract Objective: To report performance characteristics and robustness of the Breezhaler device, a new capsule based dry powder inhaler (DPI) with low resistance (0.07 cm H2O½/L/min) facilitating high inspiratory flow rates. This device was developed to deliver the novel, inhaled once-daily ultra long-acting β2-agonist indacaterol, formulated as an inhalation powder in a capsule, and other investigational drugs including NVA237 and QVA149. Research design and methods: Peak inspiratory flow rates via the DPI device were determined in patients with chronic obstructive pulmonary disease (COPD) using an Inhalation Profile Recorder. The flow-rate dependency of the in vitro performance (delivered dose and fine particle mass) of indacaterol in the DPI device was examined. Data on patient experience were captured throughout the indacaterol phase III registration program, and the robustness of the device was investigated after mechanical stress. Results: Twenty-six patients with COPD that ranged from mild to very severe were recruited (aged 49–84 years); 25 patients were able to generate flow rates in excess of 60 L/min via the DPI device. The mean delivered dose of indacaterol (150 and 300 µg) remained within 15% of the target dose, with a consistent fine particle mass at flow rates of 50–100 L/min. In the indacaterol registration program, patients with mild to very severe COPD were able to use the device successfully, with a low device complaint rate (<0.03%) and no device failures from approximately 90 000 devices. In mechanical stress tests, drop testing resulted in, at most, only cosmetic damage, with no effect on the delivered dose. Conclusion: The capsule based DPI device is a low resistance device, suitable for use by patients with a wide range of COPD severities, delivering a consistent dose irrespective of disease severity and age. The device provided consistent delivery of indacaterol with no reported device failures in clinical trials.


Aaps Pharmscitech | 2008

Minimizing Variability of Cascade Impaction Measurements in Inhalers and Nebulizers

Matthew Bonam; David Christopher; David Cipolla; Brent A. Donovan; David Goodwin; Susan Holmes; Svetlana Lyapustina; Jolyon P. Mitchell; Steve Nichols; Gunilla Pettersson; Chris Quale; Nagaraja Rao; Dilraj Singh; Terrence Tougas; Mike Van Oort; Bernd Walther; Bruce Wyka

The purpose of this article is to catalogue in a systematic way the available information about factors that may influence the outcome and variability of cascade impactor (CI) measurements of pharmaceutical aerosols for inhalation, such as those obtained from metered dose inhalers (MDIs), dry powder inhalers (DPIs) or products for nebulization; and to suggest ways to minimize the influence of such factors. To accomplish this task, the authors constructed a cause-and-effect Ishikawa diagram for a CI measurement and considered the influence of each root cause based on industry experience and thorough literature review. The results illustrate the intricate network of underlying causes of CI variability, with the potential for several multi-way statistical interactions. It was also found that significantly more quantitative information exists about impactor-related causes than about operator-derived influences, the contribution of drug assay methodology and product-related causes, suggesting a need for further research in those areas. The understanding and awareness of all these factors should aid in the development of optimized CI methods and appropriate quality control measures for aerodynamic particle size distribution (APSD) of pharmaceutical aerosols, in line with the current regulatory initiatives involving quality-by-design (QbD).


Current Medical Research and Opinion | 2007

Inhalation devices for long-acting β2-agonists: efficiency and ease of use of dry powder formoterol inhalers for use by patients with asthma and COPD

Mathieu Molimard; Denise Till; Stephan Stenglein; Dilraj Singh; Markus Krummen

ABSTRACT Background: Since the long-acting β2-agonist bronchodilator, formoterol, first became available for the treatment of subjects with asthma or chronic obstructive pulmonary disease (COPD), generic forms of this agent have been launched in a variety of devices. It is timely to review the characteristics of the original dry powder delivery device, the single-dose Aerolizer*, its in vitro performance and its comparability with other inhaler devices that are now available for delivery of formoterol. Scope: This review focuses on the performance of the formoterol Aerolizer inhaler in comparison with other inhalers. Publically available data (PubMed) on the device performance characteristics of the Aerolizer were reviewed and summarized, together with the results of comparative studies performed by the authors. Published studies (PubMed) on patient handling and inhaler technique that include the Aerolizer are described and studies comparing the clinical effect of formoterol in the Aerolizer with formoterol delivered via other devices were reviewed and are summarized. Findings: The Aerolizer performs consistently in dosing efficiency across a range of inspiratory flow rates, suggesting its suitability for use by patients with differing inspiratory flow abilities. The single-dose, capsule-based nature of the device provides patients with obvious feedback on whether the drug has been taken successfully and the Aerolizer has been shown to be one of the more easily used devices in comparative patient handling studies. Studies comparing the clinical effect of formoterol delivered by different inhalation devices show that formoterol via Aerolizer has an equivalent therapeutic effect. Conclusion: Judged on the basis of dosing efficiency, ease of use and clinical equivalence, formoterol Aerolizer remains a useful option in the management of patients with asthma or COPD.


Archive | 2014

The History and Performance of the Breezhaler Device

David Young; Lee Wood; Dilraj Singh; Juergen Dederichs

The device used for marketed indacaterol maleate is a single-dose dry powder inhaler (SDDPI) known as the Onbrez® Breezhaler®. The device was designed such that patients receive immediate feedback that the dose has been taken correctly, as they can hear a distinctive ‘whirring’ noise on correct inhalation, can check that the clear capsule is empty, and most will feel the lactose excipient against the back of their throats.


International Journal of Pharmaceutics | 2016

From single excipients to dual excipient platforms in dry powder inhaler products.

Jagdeep Shur; Robert Price; David Lewis; Paul M. Young; Grahame Woollam; Dilraj Singh; Stephen Edge


american thoracic society international conference | 2010

Dose Delivery Characterization Of Indacaterol Following Inhalation By COPD Patients

Dilraj Singh; Katrin Fiebich; Juergen Dederichs; Richard Pavkov; Martina Schulte; Knut Sommerer


Archive | 2008

Process for preparing particulates of crystalline drug substance

Gerhard Muhrer; Thomas Kieckbusch; Dilraj Singh; Ranjit Thakur; Kurt Schaffluetzel; Norbert Rasenack


Archive | 2008

Verfahren zur herstellung eines partikulären und kristallinen wirkstoffes

Gerhard Muhrer; Thomas Kieckbusch; Dilraj Singh; Ranjit Thakur; Kurt Schaffluetzel; Norbert Rasenack


Archive | 2008

Procede de preparation de particules de substance medicamenteuse cristalline

Gerhard Muhrer; Thomas Kieckbusch; Dilraj Singh; Ranjit Thakur; Kurt Schaffluetzel; Norbert Rasenack


Archive | 2008

Process for preparing a particulate and crystalline drug substance

Gerhard Muhrer; Thomas Kieckbusch; Dilraj Singh; Ranjit Thakur; Kurt Schaffluetzel; Norbert Rasenack

Collaboration


Dive into the Dilraj Singh's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

David Lewis

Chiesi Farmaceutici S.p.A.

View shared research outputs
Researchain Logo
Decentralizing Knowledge