Dilsat Ozkan
Ege University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Dilsat Ozkan.
Analytica Chimica Acta | 2002
Kagan Kerman; Dilsat Ozkan; Pinar Kara; Burcu Meric; J. Justin Gooding; Mehmet Ozsoz
An electrochemical DNA biosensor based on the recognition of single stranded DNA (ssDNA) by hybridization detection with immobilized complementary DNA oligonucleotides is presented. DNA and oligonucleotides were covalently attached through free amines on the DNA bases using N-hydroxysulfosuccinimide (NHS) and N-(3-dimethylamino)propyl-N′-ethylcarbodiimide hydrochloride (EDC) onto a carboxylate terminated alkanethiol self-assembled monolayers (SAM) preformed on a gold electrode (AuE). Differential pulse voltammetry (DPV) was used to investigate the surface coverage and molecular orientation of the immobilized DNA molecules. The covalently immobilized probe could selectively hybridize with the target DNA to form a hybrid on the surface despite the bases being attached to the SAM. The changes in the peak currents of methylene blue (MB), an electroactive label, were observed upon hybridization of probe with the target. Peak currents were found to increase in the following order: hybrid-modified AuE, mismatched hybrid-modified AuE, and the probe-modified AuE which indicates the MB signal is determined by the extent of exposed bases. Control experiments were performed using a non-complementary DNA sequence. The effect of the DNA target concentration on the hybridization signal was also studied. The interaction of MB with inosine substituted probes was investigated. Performance characteristics of the sensor are described.
Electrochemistry Communications | 2002
Pinar Kara; Kagan Kerman; Dilsat Ozkan; Burcu Meric; Arzum Erdem; Zeynep Özkan; Mehmet Ozsoz
Described here are the chronocoulometric and voltammetric parameters for methylene blue [3,7-bis(dimethylamino)phenothiazin-5-ium chloride, MB] on binding to DNA at carbon paste electrode (CPE) surface. MB, which interacts with the immobilized calf thymus DNA was detected by using single stranded DNA modified CPE (ssDNA modified CPE), bare CPE and double stranded DNA modified CPE (dsDNA modified CPE) in combination with chronocoulometry and differential pulse voltammetry (DPV) techniques. The effect of ionic strength to the behavior of MB with dsDNA and ssDNA was also studied by means of voltammetry. These results demonstrated that MB could be used as an effective electroactive hybridization indicator for DNA biosensors. Performance characteristics of the sensor are described, along with future prospects.
Talanta | 2002
Burcu Meric; Kagan Kerman; Dilsat Ozkan; Pinar Kara; Selda Erensoy; U.S. Akarca; Marco Mascini; Mehmet Ozsoz
DNA biosensors based on nucleic acid hybridization processes are rapidly being developed towards the goal of rapid and inexpensive diagnosis of genetic and infectious diseases. Electrochemical transducers are often being used for detecting the DNA hybridization event, due to their high sensitivity, small dimensions, low cost, and compatibility with microfabrication technology. In this study, an electrochemical biosensor for the voltammetric detection of DNA sequences related to the Hepatitis B virus (HBV) and TT virus (TTV) from polymerase chain reaction (PCR) amplified real samples is described for the first time. The biosensor relies on the immobilization of the 21- or 24-mer single stranded oligonucleotides (probe) related to the HBV and TTV sequences and hybridization of these oligonucleotides with their complementary sequences (target) at carbon paste electrode (CPE). The extent of hybridization between the probe and target sequences was determined by using square wave voltammetry (SWV) with moving average baseline correction and methylene blue (MB) as the hybridization indicator. As a result of the interaction between MB and the bound guanine bases of hybrid at CPE surface, the MB signal decreased, when it was compared with the MB signal, which was observed with probe modified CPE. The difference between the MB signals, obtained from the hybrid modified and the probe modified CPE is used to detect the DNA sequences of the infectious diseases from PCR amplified real samples. Numerous factors affecting the target hybridization and indicator binding reactions are optimized to maximize the sensitivity.
Bioelectrochemistry | 2002
Dilsat Ozkan; Pinar Kara; Kagan Kerman; Burcu Meric; Arzum Erdem; František Jelen; Peter E. Nielsen; Mehmet Ozsoz
Described here are the electrochemical parameters for MB on binding to DNA at hanging mercury drop electrode (HMDE), glassy carbon electrode (GCE), and carbon paste electrode (CPE) in the solution and at the electrode surface. MB, which interacts with the immobilized calf thymus DNA, was detected by using single-stranded DNA-modified HMDE or CPE (ssDNA-modified HMDE or CPE), bare HMDE or CPE, and double-stranded DNA-modified HMDE or CPE (dsDNA-modified HMDE or CPE) in combination with adsorptive transfer stripping voltammetry (AdTSV), differential pulse voltammetry (DPV), and alternating current voltammetry (ACV) techniques. The structural conformation of DNA and hybridization between synthetic peptide nucleic acid (PNA) and DNA oligonucleotides were determined by the changes in the voltammetric peak of MB. The PNA and DNA probes were also challenged with excessive and equal amount of noncomplementary DNA and a mixture that contained one-base mismatched and target DNA. The partition coefficient was also obtained from the signal of MB with probe, hybrid, and ssDNA-modified GCEs. The effect of probe, target, and ssDNA concentration upon the MB signal was investigated. These results demonstrated that MB could be used as an effective electroactive hybridization indicator for DNA biosensors. Performance characteristics of the sensor are described, along with future prospects.
Electrochemistry Communications | 2002
Dilsat Ozkan; Arzum Erdem; Pinar Kara; Kagan Kerman; J. Justin Gooding; Peter E. Nielsen; Mehmet Ozsoz
An electrochemical hybridization biosensor based on peptide nucleic acid (PNA) probes is presented. PNA probes were attached covalently through a competition of free amines on the guanine bases and also at the 5′ end of the probe, using N-(3-dimethylamino)propyl)-N′-ethylcarbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) onto a carboxylate terminated alkanethiol self-assembled monolayer (SAM) preformed on a gold electrode (AuE). The covalently immobilized probe could selectively hybridize with the target DNA to form a hybrid on the surface despite the bases being attached to the SAM. The changes in the peak currents of methylene blue (3,7-bis(dimethylamino)phenothiazin-5-ium chloride, MB), an electroactive label, were observed upon hybridization of probe with the target. Effective discrimination against point mutation was also obtained. Performance characteristics of the sensor are described, along with future prospects.
Electroanalysis | 2002
Burcu Meric; Kagan Kerman; Dilsat Ozkan; Pinar Kara; Mehmet Ozsoz
A novel electrochemical hybridization biosensor protocol without using an external indicator is described. The oxidation signals of adenine and guanine from calf thymus double-stranded DNA (dsDNA) and calf thymus single-stranded DNA (ssDNA) was studied by using differential pulse voltammetry (DPV) at carbon paste electrode (CPE). The oxidation signals of adenine and guanine obtained from the ssDNA modified CPE was higher than that from the dsDNA modified CPE due to the accessible unbound adenine and guanine bases. The electrochemical determination of hybridization between native capture DNA probe and target oligonucleotides and polynucleotides such as poly[G], poly[C], poly[I] and poly[A], poly[T] were also accomplished. The dependence of the peak heights of guanine and adenine signals on the number of the respective bases in oligonucleotides was observed by means of DPV. The dependence of the guanine signal upon the concentration of the target and the noncomplementary DNA sequences was also observed. The use of the intrinsic DNA electrochemical signals for monitoring hybridization events offers several advantages over the common use of carcinogenic external indicators and expensive inosine substituted capture DNA probes, such as a shorter assay time and cost-effective procedure. Performance characteristics of the biosensor are described, along with future prospects.
Analytical Chemistry | 2008
Chan Yean Yean; Balqis Kamarudin; Dilsat Ozkan; Lee Su Yin; Pattabhiraman Lalitha; Asma Ismail; Mehmet Ozsoz, ,‡ and; Manickam Ravichandran
A general purpose enzyme-based amperometric electrochemical genosensor assay was developed wherein polymerase chain reaction (PCR) amplicons labeled with both biotin and fluorescein were detected with peroxidase-conjugated antifluorescein antibody on a screen-printed carbon electrode (SPCE). As a proof of principle, the response selectivity of the genosensor was evaluated using PCR amplicons derived from lolB gene of Vibrio cholerae. Factors affecting immobilization, hybridization, and nonspecific binding were optimized to maximize sensitivity and reduce assay time. On the basis of the background amperometry signals obtained from nonspecific organisms and positive signals obtained from known V. cholerae, a threshold point of 4.20 microA signal was determined as positive. Under the optimum conditions, the limit of detection (LOD) of the assay was 10 CFU/mL of V. cholerae. The overall precision of this assay was good, with the coefficient of variation (CV) being 3.7% using SPCE and intermittent pulse amperometry (IPA) as an electrochemical technique. The assay is sensitive, safe, and cost-effective when compared to conventional agarose gel electrophoresis, real-time PCR, and other enzyme-linked assays for the detection of PCR amplicons. Furthermore, the use of a hand-held portable reader makes it suitable for use in the field.
Analytica Chimica Acta | 2001
Kagan Kerman; Burcu Meric; Dilsat Ozkan; Pinar Kara; Arzum Erdem; Mehmet Ozsoz
The metabolites of the environmental pollutant, benzo[a]pyrene (BaP) are carcinogenic and mutagenic agents. Thus, the determination of additional products (adducts) of the interaction between DNA and BaP, attracts great interest in cancer research. In this study, the determination of interaction between BaP and calf thymus double-stranded DNA (dsDNA) was performed by using differential pulse voltammetry (DPV) and constant current chronopotentiometric stripping analysis (PSA) in connection with carbon paste electrode (CPE) or glassy carbon electrode (GCE). As a result of interaction of BaP with dsDNA, the signal obtained from the oxidation of guanine decreased and a new adduct signal at a more positive potential appeared. This new peak is attributed to the formation of an adduct from the interaction of guanine with BaP. The chemically prepared anti-7,8,9,10-tetrahydrobenzo[a]pyrene-7,8-diol-9,10-epoxide (BPDE) adduct by using iodine oxidation was analyzed and the electrochemical signal of the adduct was observed. When the dsDNA modified GCE was immersed into various concentrations of BaP solution, the oxidation peak of guanine decreased and the adduct peak increased with the increasing BaP concentration. The partition coefficient was also obtained from the peak of BaP with dsDNA. The results revealed that the formation of adducts could be determined by using electrochemical DNA biosensors, which are fast, simple and cost-effective devices. Furthermore, this study promises that the analysis of other important adducts would benefit from the introduction of electrochemical methods.
Clinica Chimica Acta | 2003
Pinar Kara; Dilsat Ozkan; Arzum Erdem; Kagan Kerman; Sacide Pehlivan; Ferda Ozkinay; Duygu Unuvar; Gulcin Itirli; Mehmet Ozsoz
The detection of Achondroplasia G380R mutation from real samples was performed by monitoring the oxidation signal of guanine. Inosine-substituted 12-mer capture probes related to the homozygous or heterozygous alleles of Achondroplasia G380R mutation were adsorbed onto carbon paste electrode (CPE) surface. No guanine signal was obtained from the capture probes, since the inosine bases were electroinactive. Then, these probes were hybridized with the denatured PCR samples on the CPE surface. The hybridization between the probe and target sequences was determined by using the oxidation signal of guanine in connection with differential pulse voltammetry (DPV). The oxidation signal of guanine was observed as a result of the specific hybridization between the probe and PCR sample. The changes in the peak height of the guanine signal provided the information whether the PCR sample contained heterozygous allele or homozygous allele. Numerous factors affecting the hybridization and nonspecific binding events were optimized to detect down to 41.24 fmol/ml target DNA. The electrochemical detection of Achondroplasia G380R mutation from PCR samples greatly shortened and simplified the diagnosis for the homozygous mutant type, which is lethal for the newborn.
international conference of the ieee engineering in medicine and biology society | 2001
Kagan Kerman; Burcu Meric; Dilsat Ozkan; Pinar Kara; Metimet Ozsoz
Nucleic acids have become the ultimate tools in the recognition and monitoring of many important compounds. There is a great demand for a detection system which cannot only determine specific DNA fragments, but can also determine the exact total nucleic acid content of a sample. For more than a decade, DNA biosensor technologies are under intense investigation owing to their great promise for rapid and low-cost detection of specific DNA sequences in human, viral and bacterial nucleic acids. Here we describe an electrochemical DNA biosensor for the detection of DNA hybridization using the oxidation signals of guanine and adenine and the reduction signals of MB in connection with DPV.