Medical Physics | 2014
Éric Poulin; Emmanuel Racine; Dirk Binnekamp; Luc Beaulieu
PURPOSE In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. METHODS For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora(®) Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. RESULTS Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. CONCLUSIONS The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators.
Journal of Contemporary Brachytherapy | 2015
Samir Boutaleb; Emmanuel Racine; Olivier Fillion; Antonio Bonillas; Gilion Hautvast; Dirk Binnekamp; Luc Beaulieu
Purpose Accurate insertion and overall needle positioning are key requirements for effective brachytherapy treatments. This work aims at demonstrating the accuracy performance and the suitability of the Aurora® V1 Planar Field Generator (PFG) electromagnetic tracking system (EMTS) for real-time treatment assistance in interstitial brachytherapy procedures. Material and methods The systems performance was characterized in two distinct studies. First, in an environment free of EM disturbance, the boundaries of the detection volume of the EMTS were characterized and a tracking error analysis was performed. Secondly, a distortion analysis was conducted as a means of assessing the tracking accuracy performance of the system in the presence of potential EM disturbance generated by the proximity of standard brachytherapy components. Results The tracking accuracy experiments showed that positional errors were typically 2 ± 1 mm in a zone restricted to the first 30 cm of the detection volume. However, at the edges of the detection volume, sensor position errors of up to 16 mm were recorded. On the other hand, orientation errors remained low at ± 2° for most of the measurements. The EM distortion analysis showed that the presence of typical brachytherapy components in vicinity of the EMTS had little influence on tracking accuracy. Position errors of less than 1 mm were recorded with all components except with a metallic arm support, which induced a mean absolute error of approximately 1.4 mm when located 10 cm away from the needle sensor. Conclusions The Aurora® V1 PFG EMTS possesses a great potential for real-time treatment assistance in general interstitial brachytherapy. In view of our experimental results, we however recommend that the needle axis remains as parallel as possible to the generator surface during treatment and that the tracking zone be restricted to the first 30 cm from the generator surface.
Physics in Medicine and Biology | 2015
Maxence Borot de Battisti; M. Maenhout; Baudouin Denis de Senneville; Gilion Hautvast; Dirk Binnekamp; Jan J.W. Lagendijk; Marco van Vulpen; Marinus A. Moerland
Focal high-dose-rate (HDR) for prostate cancer has gained increasing interest as an alternative to whole gland therapy as it may contribute to the reduction of treatment related toxicity. For focal treatment, optimal needle guidance and placement is warranted. This can be achieved under MR guidance. However, MR-guided needle placement is currently not possible due to space restrictions in the closed MR bore. To overcome this problem, a MR-compatible, single-divergent needle-implant robotic device is under development at the University Medical Centre, Utrecht: placed between the legs of the patient inside the MR bore, this robot will tap the needle in a divergent pattern from a single rotation point into the tissue. This rotation point is just beneath the perineal skin to have access to the focal prostate tumor lesion. Currently, there is no treatment planning system commercially available which allows optimization of the dose distribution with such needle arrangement. The aim of this work is to develop an automatic inverse dose planning optimization tool for focal HDR prostate brachytherapy with needle insertions in a divergent configuration. A complete optimizer workflow is proposed which includes the determination of (1) the position of the center of rotation, (2) the needle angulations and (3) the dwell times. Unlike most currently used optimizers, no prior selection or adjustment of input parameters such as minimum or maximum dose or weight coefficients for treatment region and organs at risk is required. To test this optimizer, a planning study was performed on ten patients (treatment volumes ranged from 8.5 cm(3)to 23.3 cm(3)) by using 2-14 needle insertions. The total computation time of the optimizer workflow was below 20 min and a clinically acceptable plan was reached on average using only four needle insertions.
Medical Physics | 2016
Maxence Borot de Battisti; Baudouin Denis de Senneville; M. Maenhout; Jan J.W. Lagendijk; Marco van Vulpen; Gilion Hautvast; Dirk Binnekamp; Marinus A. Moerland
PURPOSE The development of MR-guided high dose rate (HDR) brachytherapy is under investigation due to the excellent tumor and organs at risk visualization of MRI. However, MR-based localization of needles (including catheters or tubes) has inherently a low update rate and the required image interpretation can be hampered by signal voids arising from blood vessels or calcifications limiting the precision of the needle guidance and reconstruction. In this paper, a new needle tracking prototype is investigated using fiber Bragg gratings (FBG)-based sensing: this prototype involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. This stylet can be inserted into brachytherapy needles and allows a fast measurement of the needle deflection. This study aims to assess the potential of FBG-based sensing for real-time needle (including catheter or tube) tracking during MR-guided intervention. METHODS First, the MR compatibility of FBG-based sensing and its accuracy was evaluated. Different known needle deflections were measured using FBG-based sensing during simultaneous MR-imaging. Then, a needle tracking procedure using FBG-based sensing was proposed. This procedure involved a MR-based calibration of the FBG-based system performed prior to the interventional procedure. The needle tracking system was assessed in an experiment with a moving phantom during MR imaging. The FBG-based system was quantified by comparing the gold-standard shapes, the shape manually segmented on MRI and the FBG-based measurements. RESULTS The evaluation of the MR compatibility of FBG-based sensing and its accuracy shows that the needle deflection could be measured with an accuracy of 0.27 mm on average. Besides, the FBG-based measurements were comparable to the uncertainty of MR-based measurements estimated at half the voxel size in the MR image. Finally, the mean(standard deviation) Euclidean distance between MR- and FBG-based needle position measurements was equal to 0.79 mm(0.37 mm). The update rate and latency of the FBG-based needle position measurement were 100 and 300 ms, respectively. CONCLUSIONS The FBG-based needle tracking procedure proposed in this paper is able to determine the position of the complete needle, under MR-imaging, with better accuracy and precision, higher update rate, and lower latency compared to current MR-based needle localization methods. This system would be eligible for MR-guided brachytherapy, in particular, for an improved needle guidance and reconstruction.
Physics in Medicine and Biology | 2017
M Borot de Battisti; B Denis de Senneville; Gilion Hautvast; Dirk Binnekamp; J.J.W. Lagendijk; M. Maenhout; Marinus A. Moerland
MR-guided high-dose-rate (HDR) brachytherapy has gained increasing interest as a treatment for patients with localized prostate cancer because of the superior value of MRI for tumor and surrounding tissues localization. To enable needle insertion into the prostate with the patient in the MR bore, a single needle MR-compatible robotic system involving needle-by-needle dose delivery has been developed at our institution. Throughout the intervention, dose delivery may be impaired by: (1) sub-optimal needle positioning caused by e.g. needle bending, (2) intra-operative internal organ motion such as prostate rotations or swelling, or intra-procedural rectum or bladder filling. This may result in failure to reach clinical constraints. To assess the first aforementioned challenge, a recent study from our research group demonstrated that the deposited dose may be greatly improved by real-time adaptive planning with feedback on the actual needle positioning. However, the needle insertion sequence is left to the doctor and therefore, this may result in sub-optimal dose delivery. In this manuscript, a new method is proposed to determine and update automatically the needle insertion sequence. This strategy is based on the determination of the most sensitive needle track. The sensitivity of a needle track is defined as its impact on the dose distribution in case of sub-optimal positioning. A stochastic criterion is thus presented to determine each needle track sensitivity based on needle insertion simulations. To assess the proposed sequencing strategy, HDR prostate brachytherapy was simulated on 11 patients with varying number of needle insertions. Sub-optimal needle positioning was simulated at each insertion (modeled by typical random angulation errors). In 91% of the scenarios, the dose distribution improved when the needle was inserted into the most compared to the least sensitive needle track. The computation time for sequencing was less than 6 s per needle track. The proposed needle insertion sequencing can therefore assist in delivering an optimal dose in HDR prostate brachytherapy.
Physics in Medicine and Biology | 2016
M Borot de Battisti; B Denis de Senneville; M. Maenhout; Gilion Hautvast; Dirk Binnekamp; J.J.W. Lagendijk; M. van Vulpen; Marinus A. Moerland
The development of magnetic resonance (MR) guided high dose rate (HDR) brachytherapy for prostate cancer has gained increasing interest for delivering a high tumor dose safely in a single fraction. To support needle placement in the limited workspace inside the closed-bore MRI, a single-needle MR-compatible robot is currently under development at the University Medical Center Utrecht (UMCU). This robotic device taps the needle in a divergent way from a single rotation point into the prostate. With this setup, it is warranted to deliver the irradiation dose by successive insertions of the needle. Although robot-assisted needle placement is expected to be more accurate than manual template-guided insertion, needle positioning errors may occur and are likely to modify the pre-planned dose distribution.In this paper, we propose a dose plan adaptation strategy for HDR prostate brachytherapy with feedback on the needle position: a dose plan is made at the beginning of the interventional procedure and updated after each needle insertion in order to compensate for possible needle positioning errors. The introduced procedure can be used with the single needle MR-compatible robot developed at the UMCU. The proposed feedback strategy was tested by simulating complete HDR procedures with and without feedback on eight patients with different numbers of needle insertions (varying from 4 to 12). In of the cases tested, the number of clinically acceptable plans obtained at the end of the procedure was larger with feedback compared to the situation without feedback. Furthermore, the computation time of the feedback between each insertion was below 100 s which makes it eligible for intra-operative use.
Medical Physics | 2016
Emmanuel Racine; Gilion Hautvast; Dirk Binnekamp; Luc Beaulieu
PURPOSE To describe the principles and report on the performance of a novel real-time electromagnetic (EM) seed drop detection technology for permanent implants brachytherapy procedures. METHODS A novel EM hollow needle prototype was recently developed by Philips. It possesses standard 3D tracking capability as well as a seed drop detection mechanism, both performed from a single custom built EM sensor. The detection mechanism is based on the magnetic permeability changes in the sensor as the seeds pass through. Drop position estimates are generated by the tracking information at the dropping instants. Three validation experiments were carried out in this study. First, the robustness of the detection mechanism was tested in free air with four different seed types. Detection waveforms were measured and commented. The accuracy of the seed drop position estimates was then evaluated using both 2D and 3D experiments. The procedures consisted of dropping seeds in phantoms, recording the drop position estimates, and finally registering the resulting spatial distributions on reference ones obtained by accurate modalities. Seeds were dropped on a specially designed plastic support adapted to brachytherapy template dimensions for 2D experiments, and true seed positions (reference distribution) were obtained by optical detection. In 3D experiments, seeds were dropped in edible gelatin and reference distributions were obtained by localizing the implants from CT scans of the phantoms. RESULTS All four seed types were correctly detected by the needle prototype. In total, 250 seeds were dropped on the plastic support, and 96 were dropped in gelatin phantoms. The detection rate was 100% in both cases. The minimum, maximum, and average drop position errors were, respectively, 0.1(+1.6/ - 0.1), 2.9(+1.4/ - 1.5), and 0.9(+1.4/ - 0.7) mm for 2D, and 0.1(+1.0/ - 0.1), 2.1(+1.1/ - 0.8), and 0.6(+1.2/ - 0.5) mm for 3D experiments. CONCLUSIONS The hollow needle prototype combines both EM tracking and automatic seed drop detection in a compact and convenient form. The EM detection mechanism is robust, and the seed drop position estimates appear sufficiently accurate for potential integration of the technology to current brachytherapy treatment planning systems. In that context, it would serve as a valuable tool for rapid dosimetry validation in real-time treatment delivery.
Medical Physics | 2016
M Borot de Battisti; B Denis de Senneville; M. Maenhout; Gilion Hautvast; Dirk Binnekamp; J.J.W. Lagendijk; M. van Vulpen; Marinus A. Moerland
PURPOSE This study assesses the potential of Fiber Bragg Grating (FBG)-based sensing for real-time needle (including catheter or tube) tracking during MR-guided HDR brachytherapy. METHODS The proposed FBG-based sensing tracking approach involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. When the stylet is inserted inside the lumen of the needle, the FBG sensing system can measure the needles deflection. For localization of the needle in physical space, the position and orientation of the stylet base are mandatory. For this purpose, we propose to fix the stylet base and determine its position and orientation using a MR-based calibration as follows. First, the deflection of a needle inserted in a phantom in two different configurations is measured during simultaneous MR-imaging. Then, after segmentation of the needle shapes on the MR-images, the position and orientation of the stylet base is determined using a rigid registration of the needle shapes on both MR and FBG-based measurements. The calibration method was assessed by measuring the deflection of a needle in a prostate phantom in five different configurations using FBG-based sensing during simultaneous MR-imaging. Any two needle shapes were employed for the calibration step and the proposed FGB-tracking approach was subsequently evaluated on the other three needles configurations. The tracking accuracy was evaluated by computing the Euclidian distance between the 3D FBG vs. MR-based measurements. RESULTS Over all needle shapes tested, the average(standard deviation) Euclidian distance between the FBG and MR-based measurements was 0.79mm(0.37mm). The update rate and latency of the FBG-based measurements were 100ms and 300ms respectively. CONCLUSION The proposed FBG-based protocol can measure the needle position with an accuracy, precision, update rate and latency eligible for accurate needle steering during MR-guided HDR brachytherapy. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are fulltime employees of Philips Medical Systems Nederland B.V.
Radiotherapy and Oncology | 2016
M. Borot de Battisti; B. Denise de Senneville; M. Maenhout; Gilion Hautvast; Dirk Binnekamp; J.J.W. Lagendijk; M. van Vulpen
Conclusion: The reconstructed seed positions measured by the BV probe demonstrate excellent agreement with seed positions calculated using CT data with a maximum discrepancy of 1.78 mm. It was observed that 75% of seed positions were reconstructed within 1 mm of their nominal location. The DVH study was performed to evaluate the effect of reconstructed seed locations on estimated dose delivered. V100 showed a discrepancy of 0.604 cm3 between CT and BV-derived 3D seed distribution. The BV technique has proven to be an effective tool for quality assurance during LDR brachytherapy, providing anatomical and seed positioning information without need for external irradiation for imaging.
Medical Physics | 2016
M Borot de Battisti; B Denis de Senneville; M. Maenhout; Gilion Hautvast; Dirk Binnekamp; J.J.W. Lagendijk; M. van Vulpen; Marinus A. Moerland
PURPOSE To develop a new method which adaptively determines the optimal needle insertion sequence for HDR prostate brachytherapy involving divergent needle-by-needle dose delivery by e.g. a robotic device. A needle insertion sequence is calculated at the beginning of the intervention and updated after each needle insertion with feedback on needle positioning errors. METHODS Needle positioning errors and anatomy changes may occur during HDR brachytherapy which can lead to errors in the delivered dose. A novel strategy was developed to calculate and update the needle sequence and the dose plan after each needle insertion with feedback on needle positioning errors. The dose plan optimization was performed by numerical simulations. The proposed needle sequence determination optimizes the final dose distribution based on the dose coverage impact of each needle. This impact is predicted stochastically by needle insertion simulations. HDR procedures were simulated with varying number of needle insertions (4 to 12) using 11 patient MR data-sets with PTV, prostate, urethra, bladder and rectum delineated. Needle positioning errors were modeled by random normally distributed angulation errors (standard deviation of 3 mm at the needles tip). The final dose parameters were compared in the situations where the needle with the largest vs. the smallest dose coverage impact was selected at each insertion. RESULTS Over all scenarios, the percentage of clinically acceptable final dose distribution improved when the needle selected had the largest dose coverage impact (91%) compared to the smallest (88%). The differences were larger for few (4 to 6) needle insertions (maximum difference scenario: 79% vs. 60%). The computation time of the needle sequence optimization was below 60s. CONCLUSION A new adaptive needle sequence determination for HDR prostate brachytherapy was developed. Coupled to adaptive planning, the selection of the needle with the largest dose coverage impact increases chances of reaching the clinical constraints. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are fulltime employees of Philips Medical Systems Nederland B.V.