Neurorehabilitation and Neural Repair | 2010
Richard B. Stein; Dirk G. Everaert; Aiko K. Thompson; Su Ling Chong; Maura Whittaker; Jenny Robertson; Gerald Kuether
Background. Stimulators applying functional electrical stimulation (FES) to the common peroneal nerve improve walking with a foot drop, which occurs in several disorders. Objective. To compare the orthotic and therapeutic effects of a foot drop stimulator on walking performance of subjects with chronic nonprogressive (eg, stroke) and progressive (eg, multiple sclerosis) disorders. Methods . Subjects with nonprogressive (41) and progressive (32) conditions used a foot drop stimulator for 3 to 12 months while walking in the community. Walking speed was measured with a 10-m test and a 4-minute figure-8 test; physiological cost index (PCI) and device usage were also measured. The subjects were tested with FES on and off (orthotic effect) before and after (therapeutic effect) stimulator use. Results. After 3 months of FES use, the nonprogressive and progressive groups had a similar, significant orthotic effect (5.0% and 5.7%, respectively, P < .003; percentage change in mean values) and therapeutic effect with FES off (17.8% and 9.1%, respectively, P < .005) on figure-8 walking speed. Overall, PCI showed a decreasing trend ( P = .031). The therapeutic effect on figure-8 speed diverged later between both groups to 28.0% (P < .001) and 7.9% at 11 months. The combined therapeutic plus orthotic effect on figure-8 speed at 11 months was, respectively, 37.8% (P < .001) and 13.1% (P = .012); PCI decreased 18.2% (P = .038) and 6.5%, respectively. Conclusions. Subjects with progressive and nonprogressive disorders had an orthotic benefit from FES up to 11 months. The therapeutic effect increased for 11 months in nonprogressive disorders but only for 3 months in progressive disorders. The combined effect remained significant and clinically relevant.
Neurorehabilitation and Neural Repair | 2010
Dirk G. Everaert; Aiko K. Thompson; Su Ling Chong; Richard B. Stein
Background. Long-term use of a foot-drop stimulator applying functional electrical stimulation (FES) to the common peroneal nerve improves walking performance even when the stimulator is off. This “therapeutic” effect might result from neuroplastic changes. Objective. To determine the effect of long-term use of a foot-drop stimulator on residual corticospinal connections in people with central nervous system disorders. Methods. Ten people with nonprogressive disorders (eg, stroke) and 26 with progressive disorders (eg, multiple sclerosis) used a foot-drop stimulator for 3 to 12 months while walking in the community. Walking performance and electrophysiological variables were measured before and after FES use. From the surface electromyogram of the tibialis anterior muscle, we measured the following: (1) motor-evoked potential (MEP) from transcranial magnetic stimulation over the motor cortex, (2) maximum voluntary contraction (MVC), and (3) maximum motor wave (Mmax) from stimulating the common peroneal nerve. Results. After using FES, MEP and MVC increased significantly by comparable amounts, 50% and 48%, respectively, in the nonprogressive group and 27% and 17% in the progressive group; the changes were positively correlated (R 2 = .35; P < .001). Walking speed increased with the stimulator off (therapeutic effect) by 24% (P = .008) and 7% (P = .014) in the nonprogressive and progressive groups, respectively. The changes in Mmax were small and not correlated with changes in MEP. Conclusions. The large increases in MVC and MEP suggest that regular use of a foot-drop stimulator strengthens activation of motor cortical areas and their residual descending connections, which may explain the therapeutic effect on walking speed.
Neurorehabilitation and Neural Repair | 2006
Richard B. Stein; SuLing Chong; Dirk G. Everaert; Robert Rolf; Aiko K. Thompson; Maura Whittaker; Jenny Robertson; Joyce Fung; Richard Preuss; Kimito Momose; Kouji Ihashi
Objectives. To test the efficacy and acceptance of a footdrop stimulator controlled by a tilt sensor. Methods. A nonrandomized, test-retest study of 26 subjects with footdrop of more than 1 year’s duration, resulting from various central nervous system disorders, was performed in 4 centers for at least 3 months. Speed of walking in a straight line, speed around a figure of 8, and physiological cost index (PCI) were measured with and without the device. Hours/day and steps/day using the device were recorded. Results.All but 2 subjects used the tilt sensor at home, rather than a foot switch. Walking speed increased by 15% after 3 months (n = 26; P < 0.01), 32% after 6 months (n = 16; P < 0.01), and 47% after 12 months (n = 8; P < 0.05), while PCI decreased. The number of steps taken per day of use increased significantly over time, and increased speed was directly correlated with usage. Walking speed also increased with the stimulator off, but to a lesser extent, indicating a training effect. Subject feedback from a questionnaire indicated satisfaction with the stimulator. Conclusions. Both efficacy and acceptance of the stimulator were good in a population of subjects with chronic footdrop.
Journal of Neural Engineering | 2007
Douglas J. Weber; Richard B. Stein; Dirk G. Everaert; Arthur Prochazka
Functional electrical stimulation (FES) holds great potential for restoring motor functions after brain and spinal cord injury. Currently, most FES systems are under simple finite state control, using external sensors which tend to be bulky, uncomfortable and prone to failure. Sensory nerve signals offer an interesting alternative, with the possibility of continuous feedback control. To test feasibility, we recorded from ensembles of sensory neurons with microelectrode arrays implanted in the dorsal root ganglion (DRG) of walking cats. Limb position and velocity variables were estimated accurately (average R2 values >0.5) over a range of walking speeds (0.1-0.5 m s(-1)) using a linear combination of firing rates from 10 or more neurons. We tested the feasibility of sensory control of intraspinal FES by recording from DRG neurons during hindlimb movements evoked by intraspinal microstimulation of the lumbar spinal cord in an anesthetized cat. Although electrical stimulation generated artifacts, this problem was overcome by detecting and eliminating events that occurred synchronously across the array of microelectrodes. The sensory responses to limb movement could then be measured and decoded to generate an accurate estimate of the limb state. Multichannel afferent recordings may thus provide FES systems with the feedback needed for adaptive control and perturbation compensation, though long-term stability remains a challenge.
Neurorehabilitation and Neural Repair | 2013
Dirk G. Everaert; Richard B. Stein; Gary Abrams; Alexander W. Dromerick; Gerard E. Francisco; Brian J. Hafner; Thy Huskey; Michael C. Munin; Karen J. Nolan; Conrad Kufta
Background. Studies have demonstrated the efficacy of functional electrical stimulation in the management of foot drop after stroke. Objective. To compare changes in walking performance with the WalkAide (WA) foot-drop stimulator and a conventional ankle–foot orthosis (AFO). Methods. Individuals with stroke within the previous 12 months and residual foot drop were enrolled in a multicenter, randomized controlled, crossover trial. Subjects were assigned to 1 of 3 parallel arms for 12 weeks (6 weeks/device): arm 1 (WA–AFO), n = 38; arm 2 (AFO–WA), n = 31; arm 3 (AFO–AFO), n = 24. Primary outcomes were walking speed and Physiological Cost Index for the Figure-of-8 walking test. Secondary measures included 10-m walking speed and perceived safety during this test, general mobility, and device preference for arms 1 and 2 for continued use. Walking tests were performed with (On) and without a device (Off) at 0, 3, 6, 9, and 12 weeks. Results. Both WA and AFO had significant orthotic (On–Off difference), therapeutic (change over time when Off), and combined (change over time On vs baseline Off) effects on walking speed. An AFO also had a significant orthotic effect on Physiological Cost Index. The WA had a higher, but not significantly different therapeutic effect on speed than an AFO, whereas an AFO had a greater orthotic effect than the WA (significant at 12 weeks). Combined effects on speed after 6 weeks did not differ between devices. Users felt as safe with the WA as with an AFO, but significantly more users preferred the WA. Conclusions. Both devices produce equivalent functional gains.
IEEE Transactions on Neural Systems and Rehabilitation Engineering | 2006
Douglas J. Weber; Richard B. Stein; Dirk G. Everaert; Arthur Prochazka
Sensory feedback is required by biological motor control systems to maintain stability, respond to perturbations, and adapt. Similarly, motor neuroprostheses require feedback to provide natural and complete restoration of motor functions. In this paper, we show that ensemble firing rates from the bodys mechanoreceptors can provide a natural source of kinematic state feedback and could be useful for prosthetic control. Single unit recordings from multiple primary afferent neurons were obtained during walking using multichannel electrode arrays implanted chronically in the L7 dorsal root ganglia of three cats. We typically recorded simultaneously from over 20-30 neurons during the first 7-14 days after surgery, but recordings gradually worsened thereafter. Histology indicates that a ring of inflammatory and connective tissues (100 /spl mu/m thick) develops around each microelectrode and likely contributes to the degradation in recording quality. Accurate estimates of the hindlimb trajectory were made using a linear filter with inputs from only a few neurons highly correlated with limb kinematics. The coefficients for the linear filter were identified in a least-squares fit with 5-10 s of walking data (model training stage). The estimated and actual trajectories of separate walking data generally match well for walking at a range of speeds accounting for 63/spl plusmn/22% (mean/spl plusmn/S.D. for hip, knee, and ankle) of the variance in joint angle and 72/spl plusmn/4% of the variance in joint angular velocities. These results indicate that a neural interface with primary sensory neurons in the dorsal root ganglion can provide accurate kinematic state information that may be useful for closed loop control of a neuroprosthesis.
Journal of Neural Engineering | 2013
B J Holinski; Dirk G. Everaert; Vivian K. Mushahwar; Richard B. Stein
OBJECTIVE The goal of this study was to decode sensory information from the dorsal root ganglia (DRG) in real time, and to use this information to adapt the control of unilateral stepping with a state-based control algorithm consisting of both feed-forward and feedback components. APPROACH In five anesthetized cats, hind limb stepping on a walkway or treadmill was produced by patterned electrical stimulation of the spinal cord through implanted microwire arrays, while neuronal activity was recorded from the DRG. Different parameters, including distance and tilt of the vector between hip and limb endpoint, integrated gyroscope and ground reaction force were modelled from recorded neural firing rates. These models were then used for closed-loop feedback. MAIN RESULTS Overall, firing-rate-based predictions of kinematic sensors (limb endpoint, integrated gyroscope) were the most accurate with variance accounted for >60% on average. Force prediction had the lowest prediction accuracy (48 ± 13%) but produced the greatest percentage of successful rule activations (96.3%) for stepping under closed-loop feedback control. The prediction of all sensor modalities degraded over time, with the exception of tilt. SIGNIFICANCE Sensory feedback from moving limbs would be a desirable component of any neuroprosthetic device designed to restore walking in people after a spinal cord injury. This study provides a proof-of-principle that real-time feedback from the DRG is possible and could form part of a fully implantable neuroprosthetic device with further development.
Journal of Clinical Neurophysiology | 2013
Richard B. Stein; Dirk G. Everaert; François D. Roy; SuLing Chong; Maryam Soleimani
Background: Voluntary contractions (VOL), functional electrical stimulation (FES), and transcranial magnetic stimulation (TMS) can facilitate corticospinal connections. Objective: To find the best methods for increasing corticospinal excitability by testing eight combinations: (1) VOL, (2) FES, (3) FES + VOL, (4) TMS, (5) TMS + VOL, (6) paired associative stimulation (PAS) consisting of FES + TMS, (7) PAS + VOL, and (8) double-pulse TMS + VOL. Methods: Interventions were applied for 3 × 10 minutes in 15 able-bodied subjects, 14 subjects with stable central nervous system lesions (e.g., chronic stroke, and incomplete spinal cord injury) and 16 subjects with progressive central nervous system conditions (e.g., secondary progressive multiple sclerosis). Motor-evoked potentials (MEP), M-waves, and H-reflexes were monitored over a 1-hour period. Results: Three interventions (PAS, PAS + VOL, and double-pulse TMS + VOL) caused 15% to 20% increases (P < 0.05) in the MEP at a stimulus level that initially produced a half-maximal response (MEPhalf) during a contraction. Interventions were less effective in both clinical groups than in the able-bodied group. Interventions with VOL were more effective in increasing the MEPhalf than those without (P = 0.022). When more modalities were combined, the MEP increases were larger (P = 0.022). Conclusions: (1) Short-term application of FES, TMS, and VOL can facilitate corticospinal pathways, particularly when methods are combined. (2) The effects may depend on the total activation of neural pathways, which is reduced in central nervous system disorders.
Journal of Neural Engineering | 2012
Kevin A. Mazurek; B J Holinski; Dirk G. Everaert; Richard B. Stein; Ralph Etienne-Cummings; Vivian K. Mushahwar
The biological central pattern generator (CPG) integrates open and closed loop control to produce over-ground walking. The goal of this study was to develop a physiologically based algorithm capable of mimicking the biological system to control multiple joints in the lower extremities for producing over-ground walking. The algorithm used state-based models of the step cycle each of which produced different stimulation patterns. Two configurations were implemented to restore over-ground walking in five adult anaesthetized cats using intramuscular stimulation (IMS) of the main hip, knee and ankle flexor and extensor muscles in the hind limbs. An open loop controller relied only on intrinsic timing while a hybrid-CPG controller added sensory feedback from force plates (representing limb loading), and accelerometers and gyroscopes (representing limb position). Stimulation applied to hind limb muscles caused extension or flexion in the hips, knees and ankles. A total of 113 walking trials were obtained across all experiments. Of these, 74 were successful in which the cats traversed 75% of the 3.5 m over-ground walkway. In these trials, the average peak step length decreased from 24.9 ± 8.4 to 21.8 ± 7.5 (normalized units) and the median number of steps per trial increased from 7 (Q1 = 6, Q3 = 9) to 9 (8, 11) with the hybrid-CPG controller. Moreover, within these trials, the hybrid-CPG controller produced more successful steps (step length ≤ 20 cm; ground reaction force ≥ 12.5% body weight) than the open loop controller: 372 of 544 steps (68%) versus 65 of 134 steps (49%), respectively. This supports our previous preliminary findings, and affirms that physiologically based hybrid-CPG approaches produce more successful stepping than open loop controllers. The algorithm provides the foundation for a neural prosthetic controller and a framework to implement more detailed control of locomotion in the future.
international conference of the ieee engineering in medicine and biology society | 2011
B J Holinski; Kevin A. Mazurek; Dirk G. Everaert; Richard B. Stein; Vivian K. Mushahwar
The overall objective of this project is to develop a feedback-driven intraspinal microstimulation (ISMS) system. We hypothesize that ISMS will enhance the functionality of stepping by reducing muscle fatigue and producing synergistic movements by activating neural networks in the spinal cord. In the present pilot study, the controller was tested with ISMS and external sensors (force plates, gyroscopes, and accelerometers). Cats were partially supported in a sling and bi-laterally stepped overground on a 4-m instrumented walkway. The walkway had variable friction. Limb angle was controlled to within 10° even in the presence of variable friction. Peak ground reaction forces in each limb were approximately 12% of body weight (12.5% was full load bearing in this experimental setup); rarely, the total supportive force briefly decreased to as low as 4.1%. Magnetic resonance images were acquired of the excised spinal cord and the implanted array. The majority of electrodes (75%) were implanted successfully into their target regions. This represents the first successful application of ISMS for overground walking.