Journal of Bone and Joint Surgery-british Volume | 2010

Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: A CONSEQUENCE OF EXCESS WEAR

Dj Langton; Ss Jameson; T. J. Joyce; Nadim J. Hallab; Sonali Natu; A. V. F. Nargol

Early failure associated with adverse reactions to metal debris is an emerging problem after hip resurfacing but the exact mechanism is unclear. We analysed our entire series of 660 metal-on-metal resurfacings (Articular Surface Replacement (ASR) and Birmingham Hip Resurfacing (BHR)) and large-bearing ASR total hip replacements, to establish associations with metal debris-related failures. Clinical and radiological outcomes, metal ion levels, explant studies and lymphocyte transformation tests were performed. A total of 17 patients (3.4%) were identified (all ASR bearings) with adverse reactions to metal debris, for which revision was required. This group had significantly smaller components, significantly higher acetabular component anteversion, and significantly higher whole concentrations of blood and joint chromium and cobalt ions than asymptomatic patients did (all p < 0.001). Post-revision lymphocyte transformation tests on this group showed no reactivity to chromium or cobalt ions. Explants from these revisions had greater surface wear than retrievals for uncomplicated fractures. The absence of adverse reactions to metal debris in patients with well-positioned implants usually implies high component wear. Surgeons must consider implant design, expected component size and acetabular component positioning in order to reduce early failures when performing large-bearing metal-on-metal hip resurfacing and replacement.


Journal of Bone and Joint Surgery-british Volume | 2011

Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear.

Dj Langton; T. J. Joyce; Ss Jameson; James Lord; M. Van Orsouw; James P. Holland; A. V. F. Nargol; K. De Smet

We sought to establish the incidence of joint failure secondary to adverse reaction to metal debris (ARMD) following metal-on-metal hip resurfacing in a large, three surgeon, multicentre study involving 4226 hips with a follow-up of 10 to 142 months. Three implants were studied: the Articular Surface Replacement; the Birmingham Hip Resurfacing; and the Conserve Plus. Retrieved implants underwent analysis using a co-ordinate measuring machine to determine volumetric wear. There were 58 failures associated with ARMD. The median chromium and cobalt concentrations in the failed group were significantly higher than in the control group (p < 0.001). Survival analysis showed a failure rate in the patients with Articular Surface Replacement of 12.8% [corrected] at five years, compared with < 1% at five years for the Conserve Plus and 1.5% at ten years for the Birmingham Hip Resurfacing. Two ARMD patients had relatively low wear of the retrieved components. Increased wear from the metal-on-metal bearing surface was associated with an increased rate of failure secondary to ARMD. However, the extent of tissue destruction at revision surgery did not appear to be dose-related to the volumetric wear.


Journal of Bone and Joint Surgery-british Volume | 2011

Accelerating failure rate of the ASR total hip replacement

Dj Langton; Ss Jameson; T. J. Joyce; J. N. Gandhi; R. P. Sidaginamale; P. Mereddy; James Lord; A. V. F. Nargol

There is widespread concern regarding the incidence of adverse soft-tissue reactions after metal-on-metal (MoM) hip replacement. Recent National Joint Registry data have shown clear differences in the rates of failure of different designs of hip resurfacing. Our aim was to update the failure rates related to metal debris for the Articular Surface Replacement (ASR). A total of 505 of these were implanted. Kaplan-Meier analysis showed a failure rate of 25% at six years for the ASR resurfacing and of 48.8% for the ASR total hip replacement (THR). Of 257 patients with a minimum follow-up of two years, 67 (26.1%) had a serum cobalt concentration which was greater than 7 μg/l. Co-ordinate measuring machine analysis of revised components showed that all patients suffering adverse tissue reactions in the resurfacing group had abnormal wear of the bearing surfaces. Six THR patients had relatively low rates of articular wear, but were found to have considerable damage at the trunion-taper interface. Our results suggest that wear at the modular junction is an important factor in the development of adverse tissue reactions after implantation of a large-diameter MoM THR.


Journal of Bone and Joint Surgery-british Volume | 2008

The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip

Dj Langton; Ss Jameson; T. J. Joyce; J. Webb; A. V. F. Nargol

Increased concentrations of metal ions after metal-on-metal resurfacing arthroplasty of the hip remain a concern. Although there has been no proven link to long-term health problems or early prosthetic failure, variables associated with high metal ion concentrations should be identified and, if possible, corrected. Our study provides data on metal ion levels from a series of 76 consecutive patients (76 hips) after resurfacing arthroplasty with the Articular Surface Replacement. Chromium and cobalt ion concentrations in the whole blood of patients with smaller (<or= 51 mm) femoral components were significantly higher than in those with the larger (>or= 53 mm) components (p < 0.01). Ion concentrations in the former group were significantly related to the inclination (p = 0.01) and anteversion (p = 0.01) of the acetabular component. The same relationships were not significant in the patients with larger femoral components (p = 0.61 and p = 0.49, respectively). Accurate positioning of the acetabular component intra-operatively is essential in order to reduce the concentration of metal ions in the blood after hip resurfacing arthroplasty with the Articular Surface Replacement implant.


Journal of Bone and Joint Surgery-british Volume | 2011

HIGH FAILURE RATES WITH A LARGE DIAMETER HYBRID METAL ON METAL TOTAL HIP REPLACEMENT: CLINICAL, RADIOLOGICAL AND RETRIEVAL ANALYSIS

B.J.R.F. Bolland; David Culliford; Dj Langton; J. P. S. Millington; N K Arden; Jeremy Latham

This study reports the mid-term results of a large-bearing hybrid metal-on-metal total hip replacement in 199 hips (185 patients) with a mean follow-up of 62 months (32 to 83). Two patients died of unrelated causes and 13 were lost to follow-up. In all, 17 hips (8.5%) have undergone revision, and a further 14 are awaiting surgery. All revisions were symptomatic. Of the revision cases, 14 hips showed evidence of adverse reactions to metal debris. The patients revised or awaiting revision had significantly higher whole blood cobalt ion levels (p = 0.001), but no significant difference in acetabular component size or position compared with the unrevised patients. Wear analysis (n = 5) showed increased wear at the trunnion-head interface, normal levels of wear at the articulating surfaces and evidence of corrosion on the surface of the stem. The cumulative survival rate, with revision for any reason, was 92.4% (95% confidence interval 87.4 to 95.4) at five years. Including those awaiting surgery, the revision rate would be 15.1% with a cumulative survival at five years of 89.6% (95% confidence interval 83.9 to 93.4). This hybrid metal-on-metal total hip replacement series has shown an unacceptably high rate of failure, with evidence of high wear at the trunnion-head interface and passive corrosion of the stem surface. This raises concerns about the use of large heads on conventional 12/14 tapers.


Journal of Bone and Joint Surgery-british Volume | 2009

Blood metal ion concentrations after hip resurfacing arthroplasty: A COMPARATIVE STUDY OF ARTICULAR SURFACE REPLACEMENT AND BIRMINGHAM HIP RESURFACING ARTHROPLASTIES

Dj Langton; Andrew P. Sprowson; T. J. Joyce; M. R. Reed; I Carluke; Paul Partington; A. V. F. Nargol

There have been no large comparative studies of the blood levels of metal ions after implantation of commercially available hip resurfacing devices which have taken into account the effects of femoral size and inclination and anteversion of the acetabular component. We present the results in 90 patients with unilateral articular surface replacement (ASR) hip resurfacings (mean time to blood sampling 26 months) and 70 patients with unilateral Birmingham Hip Resurfacing (BHR) implants (mean time 47 months). The whole blood and serum chromium (Cr) and cobalt (Co) concentrations were inversely related to the size of the femoral component in both groups (p < 0.05). Cr and Co were more strongly influenced by the position of the acetabular component in the case of the ASR, with an increase in metal ions observed at inclinations > 45 degrees and anteversion angles of < 10 degrees and > 20 degrees. These levels were only increased in the BHR group when the acetabular component was implanted with an inclination > 55 degrees. A significant relationship was identified between the anteversion of the BHR acetabular component and the levels of Cr and Co (p < 0.05 for Co), with an increase observed at anteversion angles < 10 degrees and > 20 degrees. The median whole blood and serum Cr concentrations of the male ASR patients were significantly lower than those of the BHR men (p < 0.001). This indicates that reduced diametral clearance may equate to a reduction in metal ion concentrations in larger joints with satisfactory orientation of the acetabular component.


Bone and Joint Research | 2012

Taper junction failure in large-diameter metal-on-metal bearings

Dj Langton; R. P. Sidaginamale; James Lord; A. V. F. Nargol; T. J. Joyce

Objectives An ongoing prospective study to investigate failing metal-on-metal hip prostheses was commenced at our centre in 2008. We report on the results of the analysis of the first consecutive 126 failed mated total hip prostheses from a single manufacturer. Methods Analysis was carried out using highly accurate coordinate measuring to calculate volumetric and linear rates of the articular bearing surfaces and also the surfaces of the taper junctions. The relationship between taper wear rates and a number of variables, including bearing diameter and orientation of the acetabular component, was investigated. Results The measured rates of wear and distribution of material loss from the taper surfaces appeared to show that the primary factor leading to taper failure is the increased lever arm acting on this junction in contemporary large-diameter metal-on-metal hip replacements. Conclusions Our analysis suggests that varus stems, laterally engaging taper systems and larger head diameters all contribute to taper failure.


Journal of Clinical Pathology | 2012

Adverse reactions to metal debris: histopathological features of periprosthetic soft tissue reactions seen in association with failed metal on metal hip arthroplasties

Sonali Natu; R. P. Sidaginamale; Jamshid Gandhi; Dj Langton; Antoni V.F. Nargol

Aim To describe the histopathology of localised adverse reactions to metal debris (ARMD) seen in association with failed metal on metal (MoM) hip arthroplasties. The nature of aseptic lymphocytic vasculitis associated lesion (ALVAL) is investigated. Methods Periprosthetic soft tissues biopsied at time of revision from failed MoM hip arthroplasties from January 2007 to March 2011 were analysed. The inflammatory cell response was categorised into perivascular lymphocytic cuffing (ALVAL), lymphoid aggregate formation with or without germinal centres, metallosis characterised by sheets of macrophages with intracytoplasmic metallic debris and well-defined granulomas. Results 123 patient samples were analysed, 36 males (29.2%) and 87 females (70.8%). Three cases showing complete tissue necrosis were excluded. Patients were reviewed between 3.27 to 69.6 months postarthroplasty, with an average of 30.92 months. 103 cases (85.8%) showed ALVAL, 18 cases also showed well-defined granulomas. Of the 103 cases with ALVAL, 60 cases also showed a diffuse chronic lymphocytic synovitis, and 40 cases showed lymphoid aggregates with germinal centres. 17 cases (14.2%) showed pure metallosis. Small vessels showing ALVAL expressed peripheral node addressin. Conclusions ARMD is a spectrum of changes comprising of pure metallosis, ALVAL and granulomatous inflammation. ALVAL, a distinctive inflammatory response seen in ARMD, is a precursor of lymphoid neogenesis. Lymphoid neogenesis documented in a variety of chronic inflammatory conditions most probably contributes to tissue necrosis and prosthetic failure seen in MoM hip arthroplasties. The role of vascular changes in contributing to necrosis is unclear at this stage.


Orthopaedics & Traumatology-surgery & Research | 2013

European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing.

F. Hannemann; A. Hartmann; Jochen Schmitt; Jörg Lützner; A. Seidler; P. Campbell; C.P. Delaunay; Hans Drexler; Harmen B. Ettema; Eduardo García-Cimbrelo; H. Huberti; K. Knahr; Joachim Kunze; Dj Langton; Wolfgang Lauer; I.D. Learmonth; Christoph H. Lohmann; Michael M. Morlock; Markus A. Wimmer; Luigi Zagra; Klaus-Peter Günther

INTRODUCTION There is an ongoing debate about the optimal use of metal-on-metal (MoM) bearings in total hip replacement, since there are uncertainties about local and systemic adverse effects due to wear and corrosion of these bearings. Despite various national recommendations, efforts to achieve international harmonization of specific evidence-based recommendations for best practice are still lacking. HYPOTHESIS An international consensus study group should be able to develop recommendations on the use and monitoring of MoM bearings, preferably at the European level, through a multidisciplinary approach, by integrating the perspectives of various stakeholders. MATERIALS AND METHODS Twenty-one experts representing three stakeholder groups and eight countries participated in this European consensus study, which consisted of a consensus meeting, subsequent structured discussion, and consensus voting. RESULTS The current statement defines first of all benefits, local and systemic risks, as well as uncertain issues related to MoM bearings. Safety assessment after implantation of MoM comprises all patients. A closer follow-up is recommended for large head MoM (≥36mm) and resurfacing. In these implants basic follow-up should consist of x-rays and metal ion measurement of cobalt in whole blood, performed with GF-AAS or ICP-MS. Clinical and/or radiographic abnormality as well as elevated ion levels needs additional imaging (ultrasound, CT-scan and/or MARS-MRI). Cobalt values less than 2 μg/L are probably devoid of clinical concern, the threshold value for clinical concern is expected to be within the range of 2-7 μg/L. DISCUSSION This is the first multinational, interdisciplinary, and multiprofessional approach for developing a recommendation for the use and monitoring of MoM bearings in total hip replacement. The current recommendations are in partial agreement with previous statements regarding the extent of follow-up and imaging techniques. They however differ from previous communications regarding measurement of metal ions and especially the investigated medium, technique, and eventual threshold levels. LEVEL OF EVIDENCE Level V, expert opinion/agreement conference.


Journal of Arthroplasty | 2010

Cup Anteversion in Hip Resurfacing: Validation of EBRA and the Presentation of a Simple Clinical Grading System

Dj Langton; Andrew P. Sprowson; Dhirendra Mahadeva; Sharad Bhatnagar; James P. Holland; Antoni V.F. Nargol

The use of large metal on metal bearings has led to a reduction in the risk of dislocation post hip arthroplasty. Because of this, and also because of the technical difficulties associated with resurfacing surgery in particular, it could be argued that a less meticulous approach to acetabular cup placement has developed in comparison with conventional metal on polyethylene arthroplasty. Resurfacing cups may produce significant clinical problems when placed at the extremes of version, including increased production of metal debris and psoas tendonitis. Presented in this article is evidence that EBRA software (Einzel-Bild-Roentgen-Analysis, University of Innsbruck, Austria) can be used to reliably assess the version of resurfacing cups, when radiographs are of sufficient quality. The cups have characteristic appearances when placed at the extremes of version. These characteristics can allow the surgeon to identify poorly positioned cups without the use of software.

Collaboration


Dive into the Dj Langton's collaboration.

Top Co-Authors

Avatar

A. V. F. Nargol

University Hospital of North Tees

View shared research outputs
Top Co-Authors

Avatar

Ss Jameson

University Hospital of North Tees

View shared research outputs
Top Co-Authors

Avatar

Antoni V.F. Nargol

University Hospital of North Tees

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Sonali Natu

University Hospital of North Tees

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Avf Nargol

University Hospital of North Tees

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Anthony Nargol

University Hospital of North Tees

View shared research outputs
Top Co-Authors

Avatar

I Carluke

Northumbria Healthcare NHS Foundation Trust

View shared research outputs
Researchain Logo
Decentralizing Knowledge