Dominicus Danardono Dwi Prija Tjahjana
Sebelas Maret University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Hotspot
Dive into the research topics where Dominicus Danardono Dwi Prija Tjahjana is active.
Publication
Featured researches published by Dominicus Danardono Dwi Prija Tjahjana.
INTERNATIONAL CONFERENCE ON ENGINEERING, SCIENCE AND NANOTECHNOLOGY 2016 (ICESNANO 2016) | 2017
B. S. Premono; Dominicus Danardono Dwi Prija Tjahjana; Syamsul Hadi
The aims of this paper are to investigate the characteristic of the wind speed and wind energy potential in the northern coastal region of Semarang, Central Java, Indonesia. The wind data was gained from Meteorological Station of Semarang, with ten-min average time series wind data for one year period, at the height of 10 m. Weibull distribution has been used to determine the wind power density and wind energy density of the site. It was shown that the value of the two parameters, shape parameter k, and scale parameter c, were 3.37 and 5.61 m/s, respectively. The annual mean wind speed and wind speed carrying the maximum energy were 5.32 m/s and 6.45 m/s, respectively. Further, the annual energy density at the site was found at a value of 103.87 W/m2, and based on Pacific North-west Laboratory (PNL) wind power classification, at the height of 10 m, the value of annual energy density is classified into class 2. The commercial wind turbine is chosen to simulate the wind energy potential of the site. The POL...
SUSTAINABLE ENERGY AND ADVANCED MATERIALS : Proceeding of the 4th International Conference and Exhibition on Sustainable Energy and Advanced Materials 2015 (ICE-SEAM 2015) | 2016
Dominicus Danardono Dwi Prija Tjahjana; I. K. Al-Masuun; A. Gustiantono
This paper presents the characteristics of wind speed and wind energy potential in the Pandansimo Beach-Yogyakarta based on Weibull distribution analysis. Ten-min average time series wind-speed data for a period of 2 year, measured at a height 50 m, are used in this study. The continuously recorded wind speed data were averaged over 10 minutes and stored in data logger. The results showed that the annual mean wind speed at location is 6.249 m/s, while the annual mean power densities is 264 W/m². It was further shown that the mean annual value of the most probable wind speed is 5.5 m/s and the mean annual value of the wind speed carrying maximum energy is 9.608 m/s. The performance of selected commercial wind turbine models designed for electricity generation in the site was examined. The wind turbine with the highest value of capacity factor is VESTAS V-110 with 33.97% and can produce 5951.04 M Wh/year.
SUSTAINABLE ENERGY AND ADVANCED MATERIALS : Proceeding of the 4th International Conference and Exhibition on Sustainable Energy and Advanced Materials 2015 (ICE-SEAM 2015) | 2016
Dominicus Danardono Dwi Prija Tjahjana; Abdelkarim Ali Salem; Dwi Aries Himawanto
In this paper the wind energy potential in Al-Fattaih-Darnah, Libya, had been studied. Wind energy is very attractive because it can provide a clean and renewable energy. Due mostly to the uncertainty caused by the chaotic characteristics of wind near the earth’s surface, wind energy characteristic need to be investigated carefully in order to get consistent power generation. This investigation was based on one year wind data measured in 2003. As a result of the analysis, wind speed profile and wind energy potential have been developed. The wind energy potential of the location is looked very promising to generate electricity. The annual wind speed of the site is 8.21 m/s and the wind speed carrying maximum energy is 7.97 m/s. The annual power density of the site is classified into class 3. The Polaris P50-500 wind turbine can produce 768.39 M Wh/year and has capacity factor of 17.54%.
INTERNATIONAL CONFERENCE ON ENGINEERING, SCIENCE AND NANOTECHNOLOGY 2016 (ICESNANO 2016) | 2017
Budi Santoso; Dominicus Danardono Dwi Prija Tjahjana
The thermal comfort in passenger cabins needs an automotive air-conditioning system. The electric vehicle air conditioner system is driven by an electric compressor which includes a compressor and an electric motor. Almost air-conditioning system uses CFC-12, CFC-22 and HFC-134a as refrigerant. However, CFC-12 and CFC-22 will damage the ozone layer. The extreme huge global warming potentials (GWP) values of CFC-12, CFC-22, and HFC-134a represent the serious greenhouse effect of Earth. This article shows new experimental measurements and analysis by using a mixture of HC-134 to replace HFC-134a. The result is a refrigerating effect, the coefficient of performance and energy factor increase along with cooling capacity, both for HFC-134a and HC-134. The refrigerating effect of HC-134 is almost twice higher than HFC-134a. The coefficient of performance value of HC-134 is also 36.42% greater than HFC-134a. Then, the energy factor value of HC-134 is 3.78% greater than HFC-134a.
1st International Conference on Engineering, Science and Nanotechnology 2016, ICESNANO 2016 | 2017
Ubaidillah; Andreas Wibowo; Dimas Adiputra; Dominicus Danardono Dwi Prija Tjahjana; Mohd Azizi Abdul Rahman; Saiful Amri Mazlan
A magnetorheological brake (MRB) with serpentine flux type for ankle-foot orthosis (rehabilitation device) was assessed its performance regarding braking torque and dynamic range. This assessment was conducted based on a problem that the MRB did not generate sufficient braking torque for the orthosis device. The braking capability was appraised through analytical approached based on the prototype design. The magnetic circuit of the MRB design was firstly investigated its capability for generating magnetic flux at braking surface area using finite element method magnetic (FEMM) software. Governing equation was derived to determine the braking performance i.e. braking torque and dynamic range as a function of applied current. The main factors influencing the braking performance were magneto-induced shear stress, the clearance between rotor and stator, and braking surface area. Especially for shear stress, this factor was totally influenced by the magnetic flux generated within the braking area. These all fa...
SUSTAINABLE ENERGY AND ADVANCED MATERIALS : Proceeding of the 4th International Conference and Exhibition on Sustainable Energy and Advanced Materials 2015 (ICE-SEAM 2015) | 2016
Budi Santoso; Didik Djoko Susilo; Dominicus Danardono Dwi Prija Tjahjana
Vehicle cabin in tropical countries requires the cooling during the day for comfort of passengers. Air conditioning machine is commonly driven by an internal combustion engine having a great power, which the conventional compressor is connected to crank shaft. The stage of research done is driving the hermetic compressor with an electric motor, and using block expansion valve. The HFC-134a was used as refrigerant working. The primary parameters observed during the experiment are pressure, temperature, and power consumption for different cooling capacities. The results show that the highest coefficient of performance (COP) and the electric power of system are 6.3 and 638 Watt, respectively.
Archive | 2018
Fahrudin; Dominicus Danardono Dwi Prija Tjahjana; Budi Santoso
This paper present experimental test results of separator and shift angle influence on Crossflow vertical axis wind turbine. Modification by using a separator and shift angle is expected to improve the thrust on the blade so as to improve the efficiency. The design of the wind turbine is tested at different wind speeds. There are 2 variations of crossflow turbine design which will be analyzed using an experimental test scheme that is, 3 stage crossflow and 2 stage crossflow with the shift angle. Maximum power coefficient obtained as Cpmax = 0.13 at wind speed 4.05 m/s for 1 separator and Cpmax = 0.12 for 12° shear angle of wind speed 4.05 m/s. In this study, power characteristics of the crossflow rotor with separator and shift angle have been tested. The experimental data was collected by variation of 2 separator and shift angle 0°, 6°, 12° and wind speed 3.01 – 4.85 m/s.This paper present experimental test results of separator and shift angle influence on Crossflow vertical axis wind turbine. Modification by using a separator and shift angle is expected to improve the thrust on the blade so as to improve the efficiency. The design of the wind turbine is tested at different wind speeds. There are 2 variations of crossflow turbine design which will be analyzed using an experimental test scheme that is, 3 stage crossflow and 2 stage crossflow with the shift angle. Maximum power coefficient obtained as Cpmax = 0.13 at wind speed 4.05 m/s for 1 separator and Cpmax = 0.12 for 12° shear angle of wind speed 4.05 m/s. In this study, power characteristics of the crossflow rotor with separator and shift angle have been tested. The experimental data was collected by variation of 2 separator and shift angle 0°, 6°, 12° and wind speed 3.01 – 4.85 m/s.
Archive | 2018
Dominicus Danardono Dwi Prija Tjahjana; Pradityasari Purbaningrum; Syamsul Hadi; Yoga Arob Wicaksono; Dimas Adiputra
Cross flow turbine can be one of the alternative energies for regions with low wind speed. Collision between wind and the blades which happened two times caused the cross flow turbine to have high power coefficient. Some factors that influence the turbine power coefficient are diameter ratio and blade number. The objective of the research was to study the effect of the diameter ratio and the blade number to the cross flow wind turbine performance. The study was done in two dimensional (2D) computational fluid dynamics (CFD) simulation method using the ANSYS-Fluent software. The turbine diameter ratio were 0.58, 0.63, 0.68 and 0.73. The diameter ratio resulting in the highest power coefficient value was then simulated by varying the number of blades, namely 16, 20 and 24. Each variation was tested on the wind speed of 2 m/s and at the tip speed ratio (TSR) of 0.1 to 0.4 with the interval of 0.1. The wind turbine with the ratio diameter of 0.68 and the number of blades of 20 generated the highest power coefficient of 0.5 at the TSR of 0.3.Cross flow turbine can be one of the alternative energies for regions with low wind speed. Collision between wind and the blades which happened two times caused the cross flow turbine to have high power coefficient. Some factors that influence the turbine power coefficient are diameter ratio and blade number. The objective of the research was to study the effect of the diameter ratio and the blade number to the cross flow wind turbine performance. The study was done in two dimensional (2D) computational fluid dynamics (CFD) simulation method using the ANSYS-Fluent software. The turbine diameter ratio were 0.58, 0.63, 0.68 and 0.73. The diameter ratio resulting in the highest power coefficient value was then simulated by varying the number of blades, namely 16, 20 and 24. Each variation was tested on the wind speed of 2 m/s and at the tip speed ratio (TSR) of 0.1 to 0.4 with the interval of 0.1. The wind turbine with the ratio diameter of 0.68 and the number of blades of 20 generated the highest power coef...
AIP Conference Proceedings | 2018
Yoga Arob Wicaksono; Dominicus Danardono Dwi Prija Tjahjana; Syamsul Hadi
Vertical axis wind turbine like cross-flow rotor have some advantage there are, high self-starting torque, low noise, and high stability; so, it can be installed in the urban area to produce electricity. But, the urban area has poor wind condition, so the cross-flow rotor needs a guide vane to increase its performance. The aim of this study is to determine experimentally the effect of Omni-Directional Guide Vane (ODGV) on the performance of a cross-flow wind turbine. Wind tunnel experiment has been carried out for various configurations. The ODGV was placed around the cross-flow rotor in order to increase ambient wind environment of the wind turbine. The maximum power coefficient is obtained as Cpmax = 0.125 at 60° wind direction. It was 21.46% higher compared to cross-flow wind turbine without ODGV. This result showed that the ODGV able to increase the performance of the cross-flow wind turbine.Vertical axis wind turbine like cross-flow rotor have some advantage there are, high self-starting torque, low noise, and high stability; so, it can be installed in the urban area to produce electricity. But, the urban area has poor wind condition, so the cross-flow rotor needs a guide vane to increase its performance. The aim of this study is to determine experimentally the effect of Omni-Directional Guide Vane (ODGV) on the performance of a cross-flow wind turbine. Wind tunnel experiment has been carried out for various configurations. The ODGV was placed around the cross-flow rotor in order to increase ambient wind environment of the wind turbine. The maximum power coefficient is obtained as Cpmax = 0.125 at 60° wind direction. It was 21.46% higher compared to cross-flow wind turbine without ODGV. This result showed that the ODGV able to increase the performance of the cross-flow wind turbine.
AIP Conference Proceedings | 2018
Diniar Mungil Kurniawati; Dominicus Danardono Dwi Prija Tjahjana; Budi Santoso
Urban living is one of the areas with large electrical power consumption that requires a power supply that is more than rural areas. The number of multi-storey buildings such as offices, hotels and several other buildings that caused electricity power consumption in urban living is very high. Therefore, energy alternative is needed to replace the electricity power consumption from government. One of the utilization of renewable energy in accordance with these conditions is the installation of wind turbines. One type of wind turbine that is now widely studied is a crossflow wind turbines. Crossflow wind turbine is one of vertical axis wind turbine which has good self starting at low wind speed condition. Therefore, the turbine design parameter is necessary to know in order to improve turbine performance. One of wind turbine performance parameter is blades number. The main purpose of this research to investigate the effect of blades number on crossflow wind turbine performance. The design of turbine was 0.4 × 0.4 m2 tested by experimental method with configuration on three kinds of blades number were 8,16 and 20. The turbine investigated at low wind speed on 2 – 5 m/s. The result showed that best performance on 16 blade number.Urban living is one of the areas with large electrical power consumption that requires a power supply that is more than rural areas. The number of multi-storey buildings such as offices, hotels and several other buildings that caused electricity power consumption in urban living is very high. Therefore, energy alternative is needed to replace the electricity power consumption from government. One of the utilization of renewable energy in accordance with these conditions is the installation of wind turbines. One type of wind turbine that is now widely studied is a crossflow wind turbines. Crossflow wind turbine is one of vertical axis wind turbine which has good self starting at low wind speed condition. Therefore, the turbine design parameter is necessary to know in order to improve turbine performance. One of wind turbine performance parameter is blades number. The main purpose of this research to investigate the effect of blades number on crossflow wind turbine performance. The design of turbine was 0.4...