Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Dorota Rudomina is active.

Publication


Featured researches published by Dorota Rudomina.


Cancer Cytopathology | 2012

Predicting pulmonary adenocarcinoma outcome based on a cytology grading system

Carlie Sigel; Dorota Rudomina; Camelia S. Sima; Natasha Rekhtman; William D. Travis; Kim R. Geisinger; Andre L. Moreira

Pulmonary adenocarcinoma (AD) has a variety of architectural patterns. Recently, a 3‐tiered histological pattern‐based grading system was developed for stage I lung AD, stratifying patients into low, intermediate, and high risk for recurrence. However, cytology may serve as the primary method for diagnosis in patients with inoperable disease. Attempts to correlate architecture between parallel cytological and histological preparations have not been successful. Therefore, we evaluated cytomorphologic features of previously histologically graded AD to identify features of potential prognostic significance.


Diagnostic Cytopathology | 2009

Cytologic diagnosis of pulmonary adenocarcinoma with micropapillary pattern: Does it correlate with the histologic findings?

Dorota Rudomina; Oscar Lin; Andre L. Moreira

Micropapillary adenocarcinoma is associated with poor‐prognosis in several organs including the lung. The presence of small tight balls of neoplastic cells devoid of fibrovascular core in cytological preparations (micropapillary tufts) has been described as characteristic of micropapillary adenocarcinoma. In the lung, however, this criterion has not been validated. The cytological material of 46 cases of histologically proven pulmonary adenocarcinoma with a micropapillary component was compared to 33 cases with no micropapillary component to determine the specificity of micropapillary tufts for the histologic diagnosis of micropapillary adenocarcinoma. Other histologic patterns of invasive pulmonary adenocarcinomas (acinar, papillary, and solid) were also compared with patterns of neoplastic cell aggregates in cytological preparations. There were no significant differences in the distribution of micropapillary clusters between the two groups. The positive predictive value for the cytologic diagnosis of a micropapillary component in lung adenocarcinomas was of 64%. Similar findings were observed for other invasive patterns. Therefore, the detection of micropapillary tufts in cytology is not specific for the diagnosis of a pulmonary micropapillary adenocarcinoma in the lung. Diagn. Cytopathol. 2009.


Cancer Cytopathology | 2014

Impact of touch preparations on core needle biopsies

Leung Chu B. Tong; Dorota Rudomina; Natasha Rekhtman; Oscar Lin

Touch preparations (TPs) can be performed for on‐site adequacy assessment of core needle biopsies (CNBs). Although TPs can play a role in decreasing the number of nondiagnostic core biopsies, the impact of TPs on CNB has not been extensively evaluated.


Journal of Pathology Informatics | 2017

Successful secure high-definition streaming telecytology for remote cytologic evaluation

Sahussapont Joseph Sirintrapun; Dorota Rudomina; Allix Mazzella; Rusmir Feratovic; Oscar Lin

Background: The use of minimally invasive procedures to obtain material for diagnostic purposes has become more prevalent in recent years. As such, there is increased demand for immediate cytologic adequacy assessment of minimally invasive procedures. The array of different locations in which rapid on-site evaluation (ROSE) is expected requires an ever-increasing number of cytology personnel to provide support for adequacy assessment. In our study, we describe the implementation process of a telecytology (TC) system in a high case volume setting and evaluate the performance of this activity. Methods: We performed retrospectively an analysis of all consecutive remote TC ROSE evaluations obtained for 15 months. The specimens were evaluated using a TC system. The ROSE adequacy assessment obtained at the time of the procedure was compared to the final cytopathologist-rendered adequacy assessment when all the material was available for review, including the alcohol-fixed preparations. Results: A total of 8106 distinct cases were analyzed. TC-assisted preliminary adequacy assessment was highly concordant with the final cytopathologist-rendered adequacy assessment. Perfect concordance or accuracy was at 93.1% (7547/8106). The adequacy upgrade rate (inadequate specimen became adequate) was 6.8% (551/8106), and the initial adequacy downgrade (adequate specimen became inadequate) was <0.1% (8/8106). Conclusions: The TC outcome demonstrates high concordance between the initial adequacy assessment and final cytopathologist-rendered adequacy assessment. Adequacy upgrades were minor but, more importantly, our results demonstrate a minimal adequacy downgrade. The process implemented effectively eliminated the need for an attending pathologist to be physically present onsite during a biopsy procedure.


Archives of Pathology & Laboratory Medicine | 2017

Novel Modification of HistoGel-Based Cell Block Preparation Method: Improved Sufficiency for Molecular Studies

Natasha Rekhtman; Darren J. Buonocore; Dorota Rudomina; Maria A. Friedlander; Crisbane Dsouza; Gitika Aggarwal; Maria E. Arcila; Marcia Edelweiss; Oscar Lin

CONTEXT - Cell block preparation methods vary substantially across institutions and are frequently suboptimal. The growing importance of biomarker testing in the era of targeted therapies makes optimization of cell block preparation critically important. OBJECTIVE - To develop an improved cell block preparation method. DESIGN - Ex vivo fine-needle aspirates and scrapes from surgically resected tumors were used to develop an improved HistoGel (Thermo Fisher Scientific, Waltham, Massachusetts)-based cell block preparation method. Cellularity yield with the new versus the standard method was assessed in ex vivo split samples and in consecutive clinical fine-needle aspirates processed before (n = 100) and after (n = 100) the new method was implemented in our laboratory. Sufficiency of cell block material for potential molecular studies was estimated by manual cell quantitation. RESULTS - The key modification in the new method was pretreatment of the pelleted cells with 95% ethanol before the addition of HistoGel (HistoGel + ethanol method). In addition, we optimized the melting conditions of HistoGel and added a dark, inorganic marker to the cell pellets to highlight the desired level of sectioning during microtomy. Cell blocks from ex vivo split samples showed that the HistoGel + ethanol method yielded, on average, an 8.3-fold (range, 1-20) greater cellularity compared with the standard HistoGel-only method. After the switch from the standard HistoGel method to the modified method in our clinical practice, sufficiency of positive fine-needle aspirates for some molecular studies increased from 72% to 97% ( P = .002). CONCLUSIONS - We describe a simple and readily adoptable modification of the HistoGel method, which results in substantial improvement in cell capture in cell blocks, leading to a significant increase in sufficiency for potential molecular and other ancillary studies.


Journal of Pathology Informatics | 2017

Robotic telecytology for remote cytologic evaluation without an on-site cytotechnologist or cytopathologist: A tale of implementation and review of constraints

Sahussapont Joseph Sirintrapun; Dorota Rudomina; Allix Mazzella; Rusmir Feratovic; William Alago; R.H. Siegelbaum; Oscar Lin

Background: The first satellite center to offer interventional radiology procedures at Memorial Sloan Kettering Cancer Center opened in October 2014. Two of the procedures offered, fine needle aspirations and core biopsies, required rapid on-site cytologic evaluation of smears and biopsy touch imprints for cellular content and adequacy. The volume and frequency of such evaluations did not justify hiring on-site cytotechnologists, and therefore, a dynamic robotic telecytology (TC) solution was created. In this technical article, we present a detailed description of our implementation of robotic TC. Methods: Pathology devised the remote robotic TC solution after acknowledging that it would not be cost effective to staff cytotechnologists on-site at the satellite location. Sakura VisionTek was selected as our robotic TC solution. In addition to configuration of the dynamic robotic TC solution, pathology realized integrating the technology solution into operations would require a multidisciplinary effort and reevaluation of existing staffing and workflows. Results: Extensively described are the architectural framework and multidisciplinary process re-design, created to navigate the constraints of our technical, cultural, and organizational environment. Also reviewed are the benefits and challenges associated with available desktop sharing solutions, particularly accounting for information security concerns. Conclusions: Dynamic robotic TC is effective for immediate evaluations performed without on-site cytotechnology staff. Our goal is providing an extensive perspective of the implementation process, particularly technical, cultural, and operational constraints. Through this perspective, our template can serve as an extensible blueprint for other centers interested in implementing robotic TC without on-site cytotechnologists.


Journal of Pathology Informatics | 2017

Robotic telecytology for remote cytologic evaluation without an on-site cytotechnologist or cytopathologist: an active quality assessment and experience of over 400 cases

Sahussapont Joseph Sirintrapun; Dorota Rudomina; Allix Mazzella; Rusmir Feratovic; William Alago; R.H. Siegelbaum; Oscar Lin

Background: The first satellite center to offer interventional radiology procedures at Memorial Sloan Kettering Cancer Center opened in October 2014. Two of the procedures offered, fine needle aspirations and core biopsies, required a rapid on-site cytologic evaluation of smears and biopsy touch imprints for cellular content and adequacy. The volume and frequency of such evaluations did not justify hiring on-site cytotechnologists, and therefore, a dynamic robotic telecytology (TC) solution was created. In this article, we provide data on our experience with this active implementation. Sakura VisionTek was selected as our robotic TC solution. Methods: A retrospective analysis of all TC evaluations from this satellite site was performed. Information was collected on demographics, lesion location, imaging modality; a comparison of TC-assisted adequacy with final adequacy was also conducted. Results: An analysis of 439 cases was performed over a period of 23 months with perfect correlation in 92.7% (407/439) of the cases. An adequacy upgrade (inadequate specimen becomes adequate) in 6.6% (29/439) of the cases. An adequacy downgrade (adequate specimen becomes inadequate), is near zero at 0.7% (3/439) of the cases. Conclusions: Dynamic robotic TC is effective for immediate evaluations performed without on-site cytotechnology staff. The overall intent of this article is to present data and concordance rates as outcome metrics. Thus far, such outcome metrics have exceeded our expectations. Our TC implementation shows high, perfect concordance. Adequacy upgrades are minor but more relevant and impressive is a near zero adequacy downgrade. Our full implementation has been so successful that plans are in place for configurations at future satellite sites.


Diagnostic Cytopathology | 2018

Rapid on-site evaluation using telecytology: A major cancer center experience

Oscar Lin; Dorota Rudomina; Rusmir Feratovic; S. Joseph Sirintrapun

Rapid on‐site evaluation (ROSE) with cytology preparations plays a critical role in minimally invasive procedures. The time spent by a pathologist performing ROSE is unpredictable and could be used for more cost‐effective activities. The solution encountered by several institutions to address this issue is the use of telecytology (TC). This study analyzes the experience of using telecytology for ROSE in a major cancer center over a period of over 2 years.


Cancer | 2000

SpinThin, a simple, inexpensive technique for preparation of thin-layer cervical cytology from liquid-based specimens: data on 791 cases.

Walid Khalbuss; Dorota Rudomina; Noah D. Kauff; Linus Chuang; Myron R. Melamed


Cancer | 2007

Effectiveness of the Thin Prep® Imaging System in the Detection of Adenocarcinoma of the Gynecologic System

Maria A. Friedlander; Dorota Rudomina; Oscar Lin

Collaboration


Dive into the Dorota Rudomina's collaboration.

Top Co-Authors

Avatar

Oscar Lin

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Rusmir Feratovic

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Maria A. Friedlander

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Natasha Rekhtman

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Sahussapont Joseph Sirintrapun

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Allix Mazzella

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

R.H. Siegelbaum

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

William Alago

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Andre L. Moreira

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Crisbane Dsouza

Memorial Sloan Kettering Cancer Center

View shared research outputs
Researchain Logo
Decentralizing Knowledge