Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Dramane Kania is active.

Publication


Featured researches published by Dramane Kania.


Journal of Acquired Immune Deficiency Syndromes | 2010

Dried blood spot HIV-1 RNA quantification using open real-time systems in South Africa and Burkina Faso.

Johannes Viljoen; Sandrine Gampini; Sivapragashini Danaviah; Diane Valéa; Sureshnee Pillay; Dramane Kania; Nicolas Meda; Marie-Louise Newell; Philippe Van de Perre; François Rouet

There is an urgent need to assess the accuracy/feasibility of using dried blood spots (DBS) for monitoring of HIV-1 viral load in resource-limited settings. A total of 892 DBS from HIV-1-positive pregnant women and their neonates enrolled in the Kesho Bora prevention of mother-to-child transmission trial conducted in Durban (South Africa) and Bobo-Dioulasso (Burkina Faso) between May 2005 and July 2008 were tested for HIV-1 RNA. The combination Nuclisens extraction method (BioMérieux)/Generic HIV Viral Load assay (Biocentric) was performed using one DBS (in Durban) versus 2 DBS (in Bobo-Dioulasso) on 2 distinct open real-time polymerase chain reaction instruments. DBS HIV-1 RNA results were compared with plasma HIV-1 RNA and HIV serology results used as the gold standards. The limits of detection of assays on DBS were 3100 and 1550 copies per milliliter in Durban and Bobo-Dioulasso, respectively. DBS HIV-1 RNA values correlated significantly with plasma levels (n = 327; R = 0.7351) and were uniformly distributed according to duration of DBS storage at −20°C (median duration, 280 days). For early infant diagnosis, the sensitivity and specificity were 100% (95% confidence interval: 97.2 to 100.0 and 96.5 to 100.0, respectively). HIV-1 viral load kinetics in DNase-pretreated DBS were similar to those obtained in plasma specimens among 13 patients receiving antiretroviral treatment. HIV-1 RNA findings from serial infant DBS collected prospectively (n = 164) showed 100% concordance with HIV serology at 18 months of life. Our findings strongly advocate the implementation of DBS HIV-1 RNA testing in remote areas from low-income and middle-income countries.


Journal of Clinical Microbiology | 2014

Field Evaluation of Dried Blood Spots for Routine HIV-1 Viral Load and Drug Resistance Monitoring in Patients Receiving Antiretroviral Therapy in Africa and Asia

Marjorie Monleau; Avelin F. Aghokeng; Sabrina Eymard-Duvernay; Anoumou Dagnra; Dramane Kania; Nicole Ngo-Giang-Huong; Coumba Toure-Kane; Lien X. T. Truong; Marie-Laure Chaix; Eric Delaporte; Ahidjo Ayouba; Martine Peeters

ABSTRACT Dried blood spots (DBS) can be used in developing countries to alleviate the logistic constraints of using blood plasma specimens for viral load (VL) and HIV drug resistance (HIVDR) testing, but they should be assessed under field conditions. Between 2009 and 2011, we collected paired plasma-DBS samples from treatment-experienced HIV-1-infected adults in Burkina Faso, Cameroon, Senegal, Togo, Thailand, and Vietnam. The DBS were stored at an ambient temperature for 2 to 4 weeks and subsequently at −20°C before testing. VL testing was performed on the plasma samples and DBS using locally available methods: the Abbott m2000rt HIV-1 test, generic G2 real-time PCR, or the NucliSENS EasyQ version 1.2 test. In the case of virological failure (VF), i.e., a plasma VL of ≥1,000 copies/ml, HIVDR genotyping was performed on paired plasma-DBS samples. Overall, we compared 382 plasma-DBS sample pairs for DBS VL testing accuracy. The sensitivities of the different assays in different laboratories for detecting VF using DBS varied from 75% to 100% for the m2000rt test in labs B, C, and D, 91% to 93% for generic G2 real-time PCR in labs A and F, and 85% for the NucliSENS test in lab E. The specificities varied from 82% to 97% for the m2000rt and NucliSENS tests and reached only 60% for the generic G2 test. The NucliSENS test showed good agreement between plasma and DBS VL but underestimated the DBS VL. The lowest agreement was observed for the generic G2 test. Genotyping was successful for 96/124 (77%) DBS tested, and 75/96 (78%) plasma-DBS pairs had identical HIVDR mutations. Significant discrepancies in resistance interpretations were observed in 9 cases, 6 of which were from the same laboratory. DBS can be successfully used as an alternative to blood plasma samples for routine VL and HIVDR monitoring in African and Asian settings. However, the selection of an adequate VL measurement method and the definition of the VF threshold should be considered, and laboratory performance should be monitored.


PLOS ONE | 2012

Comparison of Serum HBsAg Quantitation by Four Immunoassays, and Relationships of HBsAg Level with HBV Replication and HBV Genotypes

Edouard Tuaillon; Anne-Marie Mondain; Nicolas Nagot; Laure Ottomani; Dramane Kania; Erika Nogue; Pierre-Alain Rubbo; Georges-Philippe Pageaux; Philippe Van de Perre; Jacques Ducos

Background The decline in hepatitis B virus surface antigen (HBsAg) may be an early predictor of the viral efficacy of Hepatitis B virus (HBV) therapy. The HBsAg levels obtained by different immunoassays now need comparing and the relationships between levels of HBsAg and HBV DNA alongside HBsAg and genotype must be evaluated. Methodology/Principal Findings HBsAg levels were compared among 80 patients using the Abbott Architect assay, a commercial immunoassay approved for HBsAg detection and quantitation, and three other assays derived from immunoassays approved for HBsAg detection (manufactured by Diasorin, Bio-Rad and Roche). Good correlation was found between the Abbot vs. Diasorin, Bio-Rad and Roche assays with narrow 95% limits of agreement and small mean differences: −0.06 to 0.11, −0.09 log10 IU/mL; −0.57 to 0.64, −0.04 log10 IU/mL; −0.09 to 0.45, −0.27 log10 IU/mL, respectively. These agreements were not affected by genotypes A or D. HBsAg was weakly correlated with HBV DNA, whatever the HBsAg assay used: Abbott, ρ = 0.36 p = 0.001, Diasorin ρ = 0.34, p = 0.002; Bio-Rad ρ = 0.37, p<0.001; or Roche ρ = 0.41, p<0.001. This relationship between levels of HBsAg and HBV DNA seemed to depend on genotypes. Whereas HBsAg (Abbott assay) tended to correlate with HBV DNA for genotype A (ρ = 0.44, p = 0.02), no such correlation was significant for genotypes D (ρ = 0.29, p = 0.15). Conclusion/Significance The quantitation of HBsAg in routine clinical samples is comparable between the reference assay and the adapted assays with acceptable accuracy limits, low levels of variability and minimum discrepancy. While HBsAg quantitation is not affected by HBV genotype, the observed association between levels of HBsAg and HBV DNA seems genotype dependent.


Clinical Microbiology and Infection | 2013

Combining rapid diagnostic tests and dried blood spot assays for point-of-care testing of human immunodeficiency virus, hepatitis B and hepatitis C infections in Burkina Faso, West Africa

Dramane Kania; A.M. Bekalé; Nicolas Nagot; Anne-Marie Mondain; Laure Ottomani; Nicolas Meda; M. Traoré; J.B. Ouédraogo; Jacques Ducos; P. Van de Perre; Edouard Tuaillon

People screened for human immunodeficiency virus (HIV) using rapid diagnostic tests (RDTs) in Africa remain generally unaware of their status for hepatitis B (HBV) and hepatitis C (HCV) infections. We evaluated a two-step screening strategy in Burkina Faso, using both HIV RDTs and Dried Blood Spot (DBS) assays to confirm an HIV-positive test, and to test for HBV and HCV infections. HIV counselling and point-of-care testing were performed at a voluntary counselling and testing centre with HBV, HCV status and HIV confirmation using DBS specimens, being assessed at a central laboratory. Serological testing on plasma was used as the reference standard assay to control for the performance of DBS assays. Nineteen out of 218 participants included in the study were positive for HIV using RDTs. A fourth-generation HIV ELISA and immunoblot assays on DBS confirmed HIV status. Twenty-four out of 25 participants infected with HBV were found positive for hepatitis B surface antigen (HBsAg) using DBS. One sample with a low HBsAg concentration on plasma was not detected on DBS. Five participants tested positive for HCV antibodies were confirmed positive with an immunoblot assay using DBS specimens. Laboratory results were communicated within 7 days to participants with no loss to follow up of participants between the first and second post-test counselling sessions. In conclusion, DBS collection during HIV point-of-care testing enables screening and confirmation of HBV, HCV and HIV infections. Diagnosis using DBS may assist with implementation of national programmes for HBV, HCV and HIV screening and clinical care in middle- to low-income countries.


Clinical Infectious Diseases | 2012

Maternal HIV-1 Disease Progression 18–24 Months Postdelivery According to Antiretroviral Prophylaxis Regimen (Triple-Antiretroviral Prophylaxis During Pregnancy and Breastfeeding vs Zidovudine/Single-Dose Nevirapine Prophylaxis): The Kesho Bora Randomized Controlled Trial

Bobo Dioulasso; Burkina Faso; Nicolas Meda; Paulin Fao; Odette Ky-Zerbo; Clarisse Gouem; Paulin Somda; Hervé Hien; Patrice Ouédraogo; Dramane Kania; Armande K. Sanou; Ida Ayassou Kossiwavi; Bintou Sanogo; Moussa Ouedraogo; Issa Siribié; Diane Valéa; Sayouba Ouedraogo; Roseline Somé; François Rouet; Nigel Rollins; Lynne McFetridge; Kevi Naidu; Stanley Luchters; Marcel Reyners; Eunice Irungu; Christine Katingima; Mary Mwaura; Gina Ouattara; Kishor Mandaliya; Sammy Wambua

BACKGROUND Antiretroviral (ARV) prophylaxis effectively reduces mother-to-child transmission of human immunodeficiency virus type 1 (HIV). However, it is unclear whether stopping ARVs after breastfeeding cessation affects maternal HIV disease progression. We assessed 18-24-month postpartum disease progression risk among women in a randomized trial assessing efficacy and safety of prophylactic maternal ARVs. METHODS From 2005 to 2008, HIV-infected pregnant women with CD4(+) counts of 200-500/mm(3) were randomized to receive either triple ARV (zidovudine, lamivudine, and lopinavir/ritonavir during pregnancy and breastfeeding) or AZT/sdNVP (zidovudine until delivery with single-dose nevirapine without postpartum prophylaxis). Maternal disease progression was defined as the combined endpoint of death, World Health Organization clinical stage 4 disease, or CD4(+) counts of <200/mm(3). RESULTS Among 824 randomized women, 789 had at least 1 study visit after cessation of ARV prophylaxis. Following delivery, progression risk up to 24 months postpartum in the triple ARV arm was significantly lower than in the AZT/sdNVP arm (15.7% vs 28.3%; P = .001), but the risks of progression after cessation of ARV prophylaxis (rather than after delivery) were not different (15.0% vs 13.8% 18 months after ARV cessation). Among women with CD4(+) counts of 200-349/mm(3) at enrollment, 24.0% (95% confidence interval [CI], 15.7-35.5) progressed with triple ARV, and 23.0% (95% CI, 17.8-29.5) progressed with AZT/sdNVP, whereas few women in either arm (<5%) with initial CD4(+) counts of ≥350/mm(3) progressed. CONCLUSIONS Interrupting prolonged triple ARV prophylaxis had no effect on HIV progression following cessation (compared with AZT/sdNVP). However, women on triple ARV prophylaxis had lower progression risk during the time on triple ARV. Given the high rate of progression among women with CD4(+) cells of <350/mm(3), ARVs should not be discontinued in this group. CLINICAL TRIALS REGISTRATION ISRCTN71468410.


Journal of Acquired Immune Deficiency Syndromes | 2014

Cervicovaginal HIV-1 shedding in women taking antiretroviral therapy in Burkina Faso: a longitudinal study

Andrea Low; Issouf Konate; Nicolas Nagot; Helen A. Weiss; Dramane Kania; Peter Vickerman; Michel Segondy; David Mabey; Deenan Pillay; Nicolas Meda; Philippe Van de Perre; Philippe Mayaud

Background:Antiretroviral therapy (ART) reduces transmission of HIV-1. However, genital HIV-1 can be detected in patients on ART. We analyzed factors associated with genital HIV-1 shedding among high-risk women on ART in Burkina Faso. Methods:Plasma viral load (PVL) and enriched cervicovaginal lavage HIV-1 RNA were measured every 3–6 months for up to 8 years. Random-effects logistic and linear regression models were used to analyze associations of frequency and quantity of genital HIV-1 RNA with behavioral and biological factors, adjusting for within-woman correlation. The lower limit of detection of HIV-1 RNA in plasma and eCVL samples was 300 copies per milliliter. Results:One hundred and eighty-eight participants initiated ART from 2004 to 2011. PVL was detectable in 16% (171/1050) of visits, in 52% (90/174) of women. Cervicovaginal HIV-1 RNA was detectable in 16% (128/798) of visits with undetectable plasma HIV-1 RNA in 45% (77/170) of women. After adjusting for PVL, detectable cervicovaginal HIV-1 RNA was independently associated with abnormal vaginal discharge and use of nevirapine or zidovudine vs. efavirenz and stavudine, respectively; longer time on ART and hormonal contraception were not associated with increased shedding. The presence of bacterial vaginosis, herpes simplex virus-2 DNA, and the use of nevirapine vs efavirenz were independently associated with an increased quantity of cervicovaginal HIV-1 RNA. Conclusions:Certain ART regimens, abnormal vaginal discharge, bacterial vaginosis, and genital herpes simplex virus-2 are associated with HIV-1 cervicovaginal shedding or quantity in women on ART after adjusting for PVL. This may reduce the effectiveness of ART as prevention in high-risk populations.


Transfusion | 2009

A new strategy to improve the cost‐effectiveness of human immunodeficiency virus, hepatitis B virus, hepatitis C virus, and syphilis testing of blood donations in sub‐Saharan Africa: a pilot study in Burkina Faso

Dramane Kania; Lassana Sangaré; Jean Sakandé; Abdoulaye Koanda; Yacouba Nébié; Oumarou Zerbo; Alain Wilfried Combasséré; Innocent Pierre Guissou; François Rouet

BACKGROUND: In Africa where blood‐borne agents are highly prevalent, cheaper and feasible alternative strategies for blood donations testing are specifically required.


Journal of Virological Methods | 2014

Performance of two real-time PCR assays for hepatitis B virus DNA detection and quantitation

Dramane Kania; Laure Ottomani; Nicolas Meda; Marianne Peries; Pierre Dujols; Karine Bollore; Wendy Rénier; Johannes Viljoen; Jacques Ducos; Philippe Van de Perre; Edouard Tuaillon

In-house developed real-time PCR (qPCR) techniques could be useful conjunctives to the management of hepatitis B virus (HBV) infection in resource-limited settings with high prevalence. Two qPCR assays (qPCR1 and qPCR2), based on primers/probes targeting conserved regions of the X and S genes of HBV respectively, were evaluated using clinical samples of varying HBV genotypes, and compared to the commercial Roche Cobas AmpliPrep/Cobas TaqMan HBV Test v2.0. The lower detection limit (LDL) was established at 104 IU/ml for qPCR1, and 91 IU/ml for qPCR2. Good agreement and correlation were obtained between the Roche assay and both qPCR assays (r = 0.834 for qPCR1; and r = 0.870 for qPCR2). Differences in HBV DNA load of > 0.5 Log10 IU/ml between the Roche and the qPCR assays were found in 49/122 samples of qPCR1, and 35/122 samples of qPCR2. qPCR1 tended to underestimate HBV DNA quantity in samples with a low viral load and overestimate HBV DNA concentration in samples with a high viral load when compared to the Roche test. Both molecular tools that were developed, used on an open real-time PCR system, were reliable for HBV DNA detection and quantitation. The qPCR2 performed better than the qPCR1 and had the additional advantage of various HBV genotype detection and quantitation. This low cost quantitative HBV DNA PCR assay may be an alternative solution when implementing national programmes to diagnose, monitor and treat HBV infection in low- to middle-income countries where testing for HBV DNA is not available in governmental health programmes.


Expert Opinion on Medical Diagnostics | 2011

Current challenges to viral load testing in the context of emerging genetic diversity of HIV-1

François Rouet; Florian Liegeois; Augustin Mouinga-Ondémé; Dramane Kania; Johannes Viljoen; Sammy Wambua; Nicole Ngo-Giang-Huong; Hervé Menan; Martine Peeters; Eric Nerrienet

INTRODUCTION One of the major characteristics of HIV-1 is its extreme genetic diversity. A key factor in assessing the sensitivity of a molecular-based assay measuring HIV-1 RNA viral load (VL) in plasma is its ability to detect/quantify all (or most of) relevant HIV-1 genetic subtype/recombinant forms accurately. AREAS COVERED This review provides an overview of the current commercially available quantitative real-time assays (the Abbott RealTime HIV-1, Roche TaqMan HIV-1 versions 1.0 and 2.0, BioMérieux Nuclisens EasyQ HIV-1, Siemens VERSANT HIV-1 RNA 1.0 kinetic PCR, and Biocentric Generic HIV Viral Load assays). For each assay, studies from 2005 to 2010 assessing the impact of HIV-1 genetic diversity on the reliability of HIV-1 RNA quantification are described. EXPERT OPINION In light of HIV-1 genetic diversity, a general recommendation to favor one test over the other cannot categorically be made. Larger field evaluations of HIV-1 RNA assays should be conducted in areas where HIV-1 genetic diversity is the highest. The large-scale implementation of HIV-1 VL testing is urgently required in the developing world to change HIV infection from a likely death sentence into a manageable chronic infection, as done in Northern countries.


Journal of Clinical Virology | 2015

Performances of fourth generation HIV antigen/antibody assays on filter paper for detection of early HIV infections

Dramane Kania; Tam Nguyen Truong; Ana Montoya; Nicolas Nagot; Philippe Van de Perre; Edouard Tuaillon

BACKGROUND Point-of-care testing and diagnosis of HIV acute infections play important roles in preventing transmission, but HIV rapid diagnosis tests have poor capacity to detect early infections. Filter paper can be used for capillary blood collection and HIV testing using 4th generation immunoassays. OBJECTIVES Antigen/antibody combined immunoassays were evaluated for their capacity to identify early HIV infections using filter paper in comparison with rapid test. STUDY DESIGN Thirty nine serum samples collected from HIV seroconverters were spotted onto filter paper and tested by the Roche Elecsys(®) HIV Combi PT test and the DiaSorin Liaison XL Murex HIV Ab/Ag assay. RESULTS Fourth generation immunoassays identified 34 out of 39 HIV early infections using dried serum spot, whereas the Determine™ HIV-1/2 rapid test detected 24 out of 39 HIV positive serum (87.2% vs 61.5% respectively, p = 0.009). p24 antigen was detected by the Liaison XL in 19 dried serum samples (48.7%). In the group characterized by a negative western blot, 7 out of 8 (87.5%) and 6 out of 8 (75.0%) samples were found positive for HIV using the Elecsys and the Liaison XL, respectively. None of these eight samples classified in this group of early acute infections were found positive by the rapid test. CONCLUSION Fourth generation Ag/Ab immunoassays performed on dried serum spot had good performance for HIV testing during the early phases of HIV infection. This method may be useful to detect HIV early infections in hard-to-reach populations and individuals living in remote areas before rapid tests become positive.

Collaboration


Dive into the Dramane Kania's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Nicolas Meda

University of Ouagadougou

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Nicolas Nagot

University of Montpellier

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Diane Valéa

University of Montpellier

View shared research outputs
Top Co-Authors

Avatar

Jacques Ducos

University of Montpellier

View shared research outputs
Top Co-Authors

Avatar

Karine Bollore

University of Montpellier

View shared research outputs
Top Co-Authors

Avatar

Laure Ottomani

University of Montpellier

View shared research outputs
Researchain Logo
Decentralizing Knowledge