E. Espinar
University of Seville
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by E. Espinar.
Journal of Materials Science: Materials in Medicine | 2011
E. Espinar; J.M. Llamas; A. Michiardi; Maria-Pau Ginebra; F.J. Gil
This work studies NiTi orthodontic archwires that have been treated using a new oxidation treatment for obtaining Ni-free surfaces. The titanium oxide on the surface significantly improves corrosion resistance and decreases nickel ion release, while barely affecting transformation temperatures. This oxidation treatment avoids the allergic reactions or toxicity in the surrounding tissues produced by the chemical degradation of the NiTi. In the other hand, the lack of low friction coefficient for the NiTi superelastic archwires makes difficult the optimal use of these materials in Orthodontic applications. In this study, the decrease of this friction coefficient has been achieved by means of oxidation treatment. Transformation temperatures, friction coefficient and ion release have been determined.
Journal of The Mechanical Behavior of Biomedical Materials | 2012
F.J. Gil; E. Espinar; J.M. Llamas; J. M. Manero; Maria-Pau Ginebra
Reuse of NiTi orthodontic wires has become increasingly common in dental clinics. For sterilization and recovery of the original superelastic properties of the wires, a heat treatment is usually performed between 500 and 600 °C. The aim of this study was to analyze the effect of these thermal treatments on the mechanical behavior and the microstructure of NiTi archwires of different compositions. A reduction of the Ni content was observed in the matrix of the thermally treated archwires, due to the formation of Ti(3)Ni(4) precipitates. The nickel-rich precipitates were observed and characterized by Transmission Electron Microscopy (TEM) and electron diffraction. They were found to alter the mechanical properties of the wires, decreasing the transformation stresses, and causing a loss of activation of the NiTi archwires. The release of nickel was higher in the original archwires than in the reused ones, due to the matrix nickel depletion caused by the precipitation of Ti(3)Ni(4).
Materials Science and Engineering: C | 2013
J. Briceño; A. Romeu; E. Espinar; J.M. Llamas; F.J. Gil
The aim of this work was to determine the influence of the present phases and the chemical composition on the corrosion behavior and the nickel ion release of the NiTi orthodontic archwires. Eight Ni-Ti archwires from six commercial brands, in the as-received condition, were studied. The chemical composition, roughness, microstructure and the proportion of the phases as well as the corrosion behavior were analyzed for each archwire. The nickel ion release was characterized in artificial saliva immersion settings ranging up to 4 weeks. The results show that the presence of the martensitic phase improves corrosion resistance and significantly decreases Ni release into exterior medium in comparison with the austenitic specimens. In spite of the partial loss of superelasticity produced in the martensitic phase, it could be of great interest for biomedical applications, as it could minimize sensitization and allergies and improve biocompatibility and corrosion resistance of NiTi shape memory alloys.
Materials Science and Engineering: C | 2014
Juan Carlos Varela; Marcos Velo; E. Espinar; J.M. Llamas; Elisa Rupérez; J. M. Manero; F. Javier Gil
A new thermoplastic polymer for orthodontic applications was obtained and extruded into wires with round and rectangular cross sections. We evaluated the potential of new aesthetic archwire: tensile, three point bending, friction and stress relaxation behaviour, and formability characteristics were assessed. Stresses delivered were generally slightly lower than typical beta-titanium and nickel-titanium archwires. The polymer wire has good instantaneous mechanical properties; tensile stress decayed about 2% over 2h depending on the initial stress relaxation for up to 120h. High formability allowed shape bending similar to that associated with stainless steel wires. The friction coefficients were lower than the metallic conventional archwires improving the slipping with the brackets. This new polymer could be a good candidate for aesthetic orthodontic archwires.
Journal of Materials Science: Materials in Medicine | 2012
F.J. Gil; L. Delgado; E. Espinar; J.M. Llamas
The aim of this work was to determine the influence of laser surface modification treatments on mechanical and electrochemical behavior in Ti and Ti–6Al–4V implants. For each metal, different samples were laser modified simulating the markings according to the international requirements. (It is necessary in each metallic biomaterial to mark the serial, batch and company numbers.) Microstructural changes produced by this treatment were observed: (a) the melting zone with small grain sizes and martensitic structures in above-mentioned metals and (b) the heat-affected zone (HAZ) with alpha phase in cp-Titanium with bigger grain sizes and Widmanstatten structure in Ti–6Al–4V. Positive tensile residual stress was determined by means X-ray analysis in the zones marked by laser. Furthermore, corrosion behavior was studied in a simulated body fluid at 37°C. Pitting was observed in different zones near the HAZ and the results showed a decrease of the corrosion resistance in the laser treated samples. Residual stresses and the martensitic microstructures favoured the decrease of the corrosion-fatigue life around 20% of both metals under physiological conditions.
Materials Science and Engineering: C | 2013
M. Arciniegas; J. M. Manero; E. Espinar; J.M. Llamas; J.M. Barrera; F.J. Gil
A potential new Ni-free Ti alloy for biomedical applications was assessed in order to investigate the superelastic behavior, corrosion resistance and the biocompatibility. The alloy studied was Ti19.1Nb8.8Zr. The chemical composition was determined by X-ray microanalysis, the thermoelastic martensitic transformation was characterized by high sensitivity calorimeter. The critical stresses were determined by electromechanical testing machine and the corrosion behavior was analyzed by potentiostatic equipment in artificial saliva immersion at 37°C. The results were compared with six different NiTi orthodontic archwire brands. The biocompatibility was studied by means of cultures of MG63 cells. Ni-free Ti alloy exhibits thermoelastic martensitic transformation with Ms=45°C. The phase present at 37°C was austenite which under stress can induce martensite. The stress-strain curves show a superelastic effect with physiological critical stress (low and continuous) and a minimal lost of the recovery around 150 mechanical cycles. The corrosion resistance improves the values obtained by different NiTi alloys avoiding the problem of the Ni adverse reactions caused by Ni ion release. Cell culture results showed that adhered cell number in new substrate was comparable to that obtained in a commercially pure Ti grade II or beta-titanium alloy evaluated in the same conditions. Consequently, the new alloy presents an excellent in-vitro response.
Clinical Implant Dentistry and Related Research | 2014
F. Javier Gil; E. Espinar; J.M. Llamas; Pablo Sevilla
OBJECTIVE This study focuses on the fatigue behavior of titanium dental implants as-received, with a grit-blasted surface and with a new bioactive surface treatment (2Steps). BACKGROUND The 2Step process consists of (1) an initial grit-blasting process to produce a micro-rough surface, followed by (2) a combined thermo-chemical treatment that produces a potentially bioactive surface, that is, that can form an apatitic layer when exposed to biomimetic conditions in vitro. The 2Step treatment produced micro-rough and apatitic coating implants. METHODS Residual stresses were determined by means of X-ray diffraction. The fatigue tests were carried out at 37°C on 500 dental implants, and the S-N curve was determined. The fatigue-crack nucleation for the different treatments was analyzed. RESULTS The fatigue tests show that the grit-blasting process improves the fatigue life. This is a consequence of the layer of compressive residual stresses that the treatment generates in titanium surfaces. Dental implants that had its surfaced prepared with the 2Step procedure (grit-blasting and thermo-chemical treatment) had its fatigue life decreased by 10% due to the incorporation of oxygen to the surface and the relaxation of the compressive residual stress produced by the heat treatment. CONCLUSIONS Thermo-chemical treatment is an excellent compromise between the improvement of bioactive and mechanical long-life behaviors.
Materials | 2016
Elisa Rupérez; J. M. Manero; Luis-Alberto Bravo-González; E. Espinar; F.J. Gil
A bioactive layer, free of nickel, has been performed for its greater acceptability and reliability in clinical applications for NiTi shape memory alloys. In the first step, a safe barrier against Ni release has been produced on the surface by means of a thicker rutile/anastase protective layer free of nickel. In the second step, a sodium alkaline titanate hydrogel, which has the ability to induce apatite formation, has been performed from oxidized surface. An improvement of host tissue–implant integration has been achieved in terms of Ni ions release and the bioactivity of the treated NiTi alloys has been corroborated with both in vitro and in vivo studies. The transformation temperatures (As, Af, Ms, and Mf), as well as the critical stresses (σβ⇔M), have been slightly changed due to this surface modification. Consequently, this fact must be taken into account in order to design new surface modification on NiTi implants.
Medicina Oral Patologia Oral Y Cirugia Bucal | 2013
José-María Barrera; José-María Llamas; E. Espinar; Carlos Sáenz-Ramírez; Vanesa Paredes; Juan-Carlos Pérez-Varela
The anatomy of dental compensation curve in the frontal plane described by George H. Wilson is one of the occlusal determinants of orthodontic treatment. However, there is few published comparing malocclusion and normocclusion individuals. Objectives: The aim of this study is to compare the curve of Wilson at first and second maxillary molars, normocclusion pattern and malocclusion pattern, with and without bilateral posterior crossbite, using angular references in CBCT studies. Material and Methods: We analyzed 10 cases of malocclusion with bilateral posterior crossbite, 10 cases of malocclusion without bilateral posterior crossbite and 10 cases with non orthodontic normocclusion (patients who underwent cone beam study for other reasons than orthodontic). All of them were adults, more than 19 years. Angular variables from left and right axis (line connecting the occlusal and furcation groove) of first and second molars towards a perpendicular to the frontal palate were measured. There was carried out an Anova test, Bonferroni analysis and Levene´s statistics. Results: The descriptive analysis of the results shows an average values of total maxillary curve of Wilson for first molars (sum of left and right angle) of 8.1° for normocclusion group, 0.4° for the malocclusion pattern with bilateral posterior crossbite and 16.9° for the malocclusion pattern without this alteration. The mean differences was statistical significant (P<0,042) between between malocclusion pattern groups with and without crossbite . Conclusion: The curve of Wilson, measured at maxillary first molars in patients with bilateral posterior crossbite is more concave than the other groups, suggesting no dentoalveolar compensations. Key words:Wilson curve, CBCT, buccal posterior occlusion, posterior crossbite.
Clinical Implant Dentistry and Related Research | 2014
F. Javier Gil; E. Espinar; J.M. Llamas; Pablo Sevilla
OBJECTIVE This study focuses on the fatigue behavior of titanium dental implants as-received, with a grit-blasted surface and with a new bioactive surface treatment (2Steps). BACKGROUND The 2Step process consists of (1) an initial grit-blasting process to produce a micro-rough surface, followed by (2) a combined thermo-chemical treatment that produces a potentially bioactive surface, that is, that can form an apatitic layer when exposed to biomimetic conditions in vitro. The 2Step treatment produced micro-rough and apatitic coating implants. METHODS Residual stresses were determined by means of X-ray diffraction. The fatigue tests were carried out at 37°C on 500 dental implants, and the S-N curve was determined. The fatigue-crack nucleation for the different treatments was analyzed. RESULTS The fatigue tests show that the grit-blasting process improves the fatigue life. This is a consequence of the layer of compressive residual stresses that the treatment generates in titanium surfaces. Dental implants that had its surfaced prepared with the 2Step procedure (grit-blasting and thermo-chemical treatment) had its fatigue life decreased by 10% due to the incorporation of oxygen to the surface and the relaxation of the compressive residual stress produced by the heat treatment. CONCLUSIONS Thermo-chemical treatment is an excellent compromise between the improvement of bioactive and mechanical long-life behaviors.