Medical Physics | 2010

Ion recombination for ionization chamber dosimetry in a helical tomotherapy unit

Hugo Palmans; R. Thomas; Simon Duane; E. Sterpin; Stefaan Vynckier

PURPOSEnIon recombination for ionization chambers in pulsed high-energy photon beams is a well-studied phenomenon. Despite this, the correction for ion recombination is often determined inaccurately due to the inappropriate combination of using a high polarizing voltage and the simple two-voltage method. An additional complication arises in new treatment modalities such as IMRT and tomotherapy, where the dosimetry of a superposition of many constituting fields becomes more relevant than of single static fields. For these treatment modalities, the irradiation of the ion chamber geometry can be instantaneously inhomogeneous and time dependent.nnnMETHODSnThis article presents a study of ion recombination in ionization chambers used for dosimetry in a helical tomotherapy beam. Models are presented for studying the recombination correction factors in a continuous beam, in pulsed large and small fields, and in helical fields. Measurements using Exradin A1SL, NE2571, and NE2611 type chambers and Monte Carlo simulations usingPENELOPE are performed in support of these models.nnnRESULTSnInitial recombination and charge multiplication are found to be the same in C60o and in the pulsed high-energy photon beam for the chambers and operating voltages used in this study. Applying the two-voltage technique for the A1SL chamber at its recommended operating voltage of 300 V leads to an overestimation of the recombination. Operating at a voltage of 100 V yields larger but more accurate values for the recombination correction. The recombination correction measured for this chamber in the TomoTherapy HiArt unit is lower than the 1% applied in the routine dosimetry for this treatment unit. For a helical dose delivery with a small slice width, lateral electron scatter in the cavity makes that the recombination is smaller than for an open beam delivering the same total dose. In a Farmer type chamber, a helical delivery with a 1 cm slice field results in a time and spatially integrated volume recombination of 55% of that with a 2.5 cm slice field. The relative recombination corrections for different slice widths and different field offsets with respect to the chamber center obtained from the developed models are in good agreement with experimental data.nnnCONCLUSIONSnBecause of the presence of charge multiplication, it is more accurate to determine the recombination correction at lower operating voltages than are often applied using the two-voltage method. Models and experiments for partial irradiation conditions of the ion chamber show that resulting recombination corrections are reduced compared to those for an open field. A model for helical dose deliveries results in recombination corrections that get lower with smaller slice widths. This model could be adapted to any IMRT delivery where the ion chamber is instantaneously partial and/or inhomogeneously irradiated, and could provide a practical procedure to calculate the recombination for complex deliveries for which it is difficult to be measured.


Cancers | 2015

Tumour Movement in Proton Therapy: Solutions and Remaining Questions: A Review

Dirk De Ruysscher; E. Sterpin; Karin Haustermans; Tom Depuydt

Movement of tumours, mostly by respiration, has been a major problem for treating lung cancer, liver tumours and other locations in the abdomen and thorax. Organ motion is indeed one component of geometrical uncertainties that includes delineation and target definition uncertainties, microscopic disease and setup errors. At present, minimising motion seems to be the easiest to implement in clinical practice. If combined with adaptive approaches to correct for gradual anatomical variations, it may be a practical strategy. Other approaches such as repainting and tracking could increase the accuracy of proton therapy delivery, but advanced 4D solutions are needed. Moreover, there is a need to perform clinical studies to investigate which approach is the best in a given clinical situation. The good news is that existing and emerging technology and treatment planning systems as will without doubt lead in the forthcoming future to practical solutions to tackle intra-fraction motion in proton therapy. These developments may also improve motion management in photon therapy as well.


Cancer Radiotherapie | 2014

Metabolic imaging in non-small-cell lung cancer radiotherapy

X. Geets; E. Sterpin; Marie Wanet; Dario Di Perri; John Aldo Lee

Metabolic imaging by positrons emission tomography (PET) offers new perspectives in the field of non-small-cell lung cancer radiation therapy. First, it can be used to refine the way nodal and primary tumour target volumes are selected and delineated, in better agreement with the underlying tumour reality. In addition, the non-invasive spatiotemporal mapping of the tumour biology and the organs at risk function might be further used to steer radiation dose distribution. Delivering higher dose to low responsive tumour area, in a way that better preserves the normal tissue function, should thus reconcile the tumour radiobiological imperatives (maximising tumour local control) with dose related to the treatment safety (minimising late toxicity). By predicting response early in the course of radiation therapy, PET may also participate to better select patients who are believed to benefit most from treatment intensification. Altogether, these technological advances open avenues to in-depth modify the way the treatment plan is designed and the dose is delivered, in better accordance with the radiobiology of individual solid cancers and normal tissues.


Physica Medica | 2017

Experimental assessment of proton dose calculation accuracy in inhomogeneous media

Jefferson Sorriaux; M Testa; Harald Paganetti; J. Orban de Xivry; John Aldo Lee; E. Traneus; Kevin Souris; Stefaan Vynckier; E. Sterpin

PURPOSEnProton therapy with Pencil Beam Scanning (PBS) has the potential to improve radiotherapy treatments. Unfortunately, its promises are jeopardized by the sensitivity of the dose distributions to uncertainties, including dose calculation accuracy in inhomogeneous media. Monte Carlo dose engines (MC) are expected to handle heterogeneities better than analytical algorithms like the pencil-beam convolution algorithm (PBA). In this study, an experimental phantom has been devised to maximize the effect of heterogeneities and to quantify the capability of several dose engines (MC and PBA) to handle these.nnnMETHODSnAn inhomogeneous phantom made of water surrounding a long insert of bone tissue substitute (1×10×10 cm3) was irradiated with a mono-energetic PBS field (10×10 cm2). A 2D ion chamber array (MatriXX, IBA Dosimetry GmbH) lied right behind the bone. The beam energy was such that the expected range of the protons exceeded the detector position in water and did not attain it in bone. The measurement was compared to the following engines: Geant4.9.5, PENH, MCsquare, as well as the MC and PBA algorithms of RayStation (RaySearch Laboratories AB).nnnRESULTSnFor a γ-index criteria of 2%/2mm, the passing rates are 93.8% for Geant4.9.5, 97.4% for PENH, 93.4% for MCsquare, 95.9% for RayStation MC, and 44.7% for PBA. The differences in γ-index passing rates between MC and RayStation PBA calculations can exceed 50%.nnnCONCLUSIONnThe performance of dose calculation algorithms in highly inhomogeneous media was evaluated in a dedicated experiment. MC dose engines performed overall satisfactorily while large deviations were observed with PBA as expected.


Medical Physics | 2017

Evaluation of Motion Mitigation using Abdominal Compression in the Clinical Implementation of Pencil Beam Scanning Proton Therapy of Liver Tumors

Liyong Lin; Kevin Souris; Minglei Kang; Adam Glick; Haibo Lin; Sheng Huang; Kristin Stützer; Guillaume Janssens; E. Sterpin; John Aldo Lee; Timothy D. Solberg; J McDonough; Charles B. Simone; Edgar Ben-Josef

Purpose: To determine whether individual liver tumor patients can be safely treated with pencil beam scanning proton therapy. This study reports a planning preparation workflow that can be used for beam angle selection and the evaluation of the efficacy of abdominal compression (AC) to mitigate motion. Methods: Four‐dimensional computed tomography scans (4DCT) with and without AC were available from 10 liver tumor patients with fluoroscopy‐proven motion reduction by AC, previously treated using photons. For each scan, the motion amplitudes and the motion‐induced variation of water‐equivalent thickness (ΔWET) in each voxel of the target volume were evaluated during treatment plan preparation. Optimal proton beam angles were selected after volume analysis of the respective beam‐specific planning target volume (BSPTV). M⊥80 and ΔWET80 derived from the 80th percentiles of perpendicular motion amplitude (M⊥) and ΔWET were compared with and without AC. Proton plans were created on the average CT to achieve target coverage similar to that of the conventional photon treatments. 4D dynamic dose calculation was performed postplan by synchronizing proton beam delivery timing patterns to the 4DCT phases to assess interplay and fractionation effects, and to determine motion criteria for subsequent patient treatment. Results: Selected coplanar beam angles ranged between 180° and 39°, primarily from right lateral (oblique) and posterior (oblique) directions. While AC produced a significant reduction in mean Liver‐GTV dose, any reduction in mean heart dose was patient dependent and not significant. Similarly, AC resulted in reductions in M⊥, ΔWET, and BSPTV volumes and improved dose degradation (ΔD95 and ΔD1) within the CTV. For small motion (M⊥80 < 7 mm and ΔWET80 < 5 mm), motion mitigation was not needed. For moderate motion (M⊥80 7–10 mm or ΔWET80 5–7 mm), AC produced a modest improvement. For large motion (M⊥80 > 10 mm or ΔWET80 > 7 mm), AC and/or some other form of mitigation strategies were required. Conclusion: A workflow for screening patients’ motion characteristics and optimizing beam angle selection was established for the pencil beam scanning proton therapy treatment of liver tumors. Abdominal compression was found to be useful at mitigation of moderate and large motion.


Medical Physics | 2018

Performance of a hybrid Monte Carlo‐Pencil Beam dose algorithm for proton therapy inverse planning

Ana Maria Barragan Montero; Kevin Souris; Daniel Sanchez‐Parcerisa; E. Sterpin; John Aldo Lee

PURPOSEnAnalytical algorithms have a limited accuracy when modeling very heterogeneous tumor sites. This work addresses the performance of a hybrid dose optimizer that combines both Monte Carlo (MC) and pencil beam (PB) dose engines to get the best trade-off between speed and accuracy for proton therapy plans.nnnMETHODSnThe hybrid algorithm calculates the optimal spot weights (w) by means of an iterative optimization process where the dose at each iteration is computed by using a precomputed dose influence matrix based on the conventional PB plus a correction term c obtained from a MC simulation. Updates of c can be triggered as often as necessary by calling the MC dose engine with the last corrected values of w as input. In order to analyze the performance of the hybrid algorithm against dose calculation errors, it was applied to a simplistic water phantom for which several test cases with different errors were simulated, including proton range uncertainties. Afterwards, the algorithm was used in three clinical cases (prostate, lung, and brain) and benchmarked against full MC-based optimization. The influence of different stopping criteria in the final results was also investigated.nnnRESULTSnThe hybrid algorithm achieved excellent results provided that the estimated range in a homogeneous material is the same for the two dose engines involved, i.e., PB and MC. For the three patient cases, the hybrid plans were clinically equivalent to those obtained with full MC-based optimization. Only a single update of c was needed in the hybrid algorithm to fulfill the clinical dose constraints, which represents an extra computation time to obtain c that ranged from 1 (brain) to 4xa0min (lung) with respect to the conventional PB-based optimization, and an estimated average gain factor of 14 with respect to full MC-based optimization.nnnCONCLUSIONnThe hybrid algorithm provides an improved trade-off between accuracy and speed. This algorithm can be immediately considered as an option for improving dose calculation accuracy of commercial analytical treatment planning systems, without a significant increase in the computation time (≪5xa0min) with respect to current PB-based optimization.


Radiotherapy and Oncology | 2017

Patient-specific bolus for range shifter air gap reduction in intensity-modulated proton therapy of head-and-neck cancer studied with Monte Carlo based plan optimization

Steven Michiels; A. Barragan; Kevin Souris; K. Poels; Wouter Crijns; John Aldo Lee; E. Sterpin; Sandra Nuyts; Karin Haustermans; Tom Depuydt

BACKGROUND & PURPOSEnIntensity-modulated proton therapy (IMPT) of superficial lesions requires pre-absorbing range shifter (RS) to deliver the more shallow spots. RS air gap minimization is important to avoid spot size degradation, but remains challenging in complex geometries such as in head-and-neck cancer (HNC). In this study, clinical endpoints were investigated for patient-specific bolus and for conventional RS solutions, making use of a Monte Carlo (MC) dose engine for IMPT optimization.nnnMETHODS AND MATERIALSnFor 5 oropharyngeal cancer patients, IMPT spot maps were generated using beamlets calculated with MC. The plans were optimized for three different RS configurations: 3D printed on-skin bolus, snout- and nozzle-mounted RS. Organ-at-risk (OAR) doses and late toxicity probabilities were compared between all configuration-specific optimized plans.nnnRESULTSnThe use of bolus reduced the mean dose to all OARs compared to snout and nozzle-mounted RS. The contralateral parotid gland and supraglottic larynx received on average 2.9Gy and 4.2Gy less dose compared to the snout RS. Bolus reduced the average probability for xerostomia by 3.0%. For dysphagia, bolus reduced the probability by 2.7%.nnnCONCLUSIONSnQuantification of the dosimetric advantage of patient-specific bolus shows significant reductions compared to conventional RS solutions for xerostomia and dysphagia probability. These results motivate the development of a patient-specific bolus solution in IMPT for HNC.


Medical Physics | 2015

SU-F-BRD-15: Quality Correction Factors in Scanned Or Broad Proton Therapy Beams Are Indistinguishable

Jefferson Sorriaux; M Testa; Harald Paganetti; Damien Bertrand; J. Orban de Xivry; John Aldo Lee; Hugo Palmans; Stefaan Vynckier; E. Sterpin

Purpose: The IAEA TRS-398 code of practice details the reference conditions for reference dosimetry of proton beams using ionization chambers and the required beam quality correction factors (kQ). Pencil beam scanning (PBS) requires multiple spots to reproduce the reference conditions. The objective is to demonstrate, using Monte Carlo (MC) calculations, that kQ factors for broad beams can be used for scanned beams under the same reference conditions with no significant additional uncertainty. We consider hereafter the general Alfonso formalism (Alfonso et al, 2008) for non-standard beam. Methods: To approach the reference conditions and the associated dose distributions, PBS must combine many pencil beams with range modulation and shaping techniques different than those used in passive systems (broad beams). This might lead to a different energy spectrum at the measurement point. In order to evaluate the impact of these differences on kQ factors, ion chamber responses are computed with MC (Geant4 9.6) in a dedicated scanned pencil beam (Q_pcsr) producing a 10×10cm2 composite field with a flat dose distribution from 10 to 16 cm depth. Ion chamber responses are also computed by MC in a broad beam with quality Q_ds (double scattering). The dose distribution of Q _pcsr matches the dose distribution of Q_ds. k_(Q_pcsr,Q_ds) is computed for a 2×2×0.2cm3 idealized air cavity and a realistic plane-parallel ion chamber (IC). Results: Under reference conditions, quality correction factors for a scanned composite field versus a broad beam are the same for air cavity dose response, k_(Q_pcsr,Q_ds) =1.001±0.001 and for a Roos IC, k_(Q_pcsr,Q_ds) =0.999±0.005. Conclusion: Quality correction factors for ion chamber response in scanned and broad proton therapy beams are identical under reference conditions within the calculation uncertainties. The results indicate that quality correction factors published in IAEA TRS-398 can be used for scanned beams in the SOBP of a high-energy proton beam. Jefferson Sorriaux is financed by the Walloon Region under the convention 1217662. Jefferson Sorriaux is sponsored by a public-private partnership IBA - Walloon Region


Medical Physics | 2014

SU-E-T-464: On the Equivalence of the Quality Correction Factor for Pencil Beam Scanning Proton Therapy

Jefferson Sorriaux; Harald Paganetti; M Testa; D Giantsoudi; Jan Schuemann; Damien Bertrand; J. Orban de Xivry; John Aldo Lee; Hugo Palmans; Stefaan Vynckier; E. Sterpin

PURPOSEnIn current practice, most proton therapy centers apply IAEA TRS-398 reference dosimetry protocol. Quality correction factors (kQ) take into account in the dose determination process the differences in beam qualities used for calibration unit and for treatment unit. These quality correction factors are valid for specific reference conditions. TRS-398 reference conditions should be achievable in both scattered proton beams (i.e. DS) and scanned proton beams (i.e. PBS). However, it is not a priori clear if TRS-398 kQ data, which are based on Monte Carlo (MC) calculations in scattered beams, can be used for scanned beams. Using TOPAS-Geant4 MC simulations, the study aims to determine whether broad beam quality correction factors calculated in TRS-398 can be directly applied to PBS delivery modality.nnnMETHODSnAs reference conditions, we consider a 10×10×10 cm3 homogeneous dose distribution delivered by PBS system in a water phantom (32/10 cm range/modulation) and an air cavity placed at the center of the spread-out-Bragg-peak. In order to isolate beam differences, a hypothetical broad beam is simulated. This hypothetical beam reproduces exactly the same range modulation, and uses the same energy layers than the PBS field. Ion chamber responses are computed for the PBS and hypothetical beams and then compared.nnnRESULTSnFor an air cavity of 2×2×0.2 cm3 , the ratio of ion chamber responses for the PBS and hypothetical beam qualities is 0.9991 ± 0.0016.nnnCONCLUSIONnQuality correction factors are insensitive to the delivery pattern of the beam (broad beam or PBS), as long as similar dose distributions are achieved. This investigation, for an air cavity, suggests that broad beam quality correction factors published in TRS-398 can be applied for scanned beams. J. Sorriaux is financially supported by a public-private partnership involving the company Ion Beam Applications (IBA).


Physics in Medicine and Biology | 2018

Feasibility of online IMPT adaptation using fast, automatic and robust dose restoration

Kinga Bernatowicz; Xavier Geets; A. Barragan; Guillaume Janssens; Kevin Souris; E. Sterpin

Intensity-modulated proton therapy (IMPT) offers excellent dose conformity and healthy tissue sparing, but it can be substantially compromised in the presence of anatomical changes. A major dosimetric effect is caused by density changes, which alter the planned proton range in the patient. Three different methods, which automatically restore an IMPT plan dose on a daily CT image were implemented and compared: (1) simple dose restoration (DR) using optimization objectives of the initial plan, (2) voxel-wise dose restoration (vDR), and (3) isodose volume dose restoration (iDR). Dose restorations were calculated for three different clinical cases, selected to test different capabilities of the restoration methods: large range adaptation, complex dose distributions and robust re-optimization. All dose restorations were obtained in less than 5u2009min, without manual adjustments of the optimization settings. The evaluation of initial plans on repeated CTs showed large dose distortions, which were substantially reduced after restoration. In general, all dose restoration methods improved DVH-based scores in propagated target volumes and OARs. Analysis of local dose differences showed that, although all dose restorations performed similarly in high dose regions, iDR restored the initial dose with higher precision and accuracy in the whole patient anatomy. Median dose errors decreased from 13.55 Gy in distorted plan to 9.75 Gy (vDR), 6.2 Gy (DR) and 4.3 Gy (iDR). High quality dose restoration is essential to minimize or eventually by-pass the physician approval of the restored plan, as long as dose stability can be assumed. Motion (as well as setup and range uncertainties) can be taken into account by including robust optimization in the dose restoration. Restoring clinically-approved dose distribution on repeated CTs does not require new ROI segmentation and is compatible with an online adaptive workflow.

Collaboration


Dive into the E. Sterpin's collaboration.

Top Co-Authors

Avatar

Stefaan Vynckier

Cliniques Universitaires Saint-Luc

View shared research outputs
Top Co-Authors

Avatar

John Aldo Lee

Université catholique de Louvain

View shared research outputs
Top Co-Authors

Avatar

Kevin Souris

Université catholique de Louvain

View shared research outputs
Top Co-Authors

Avatar

Guillaume Janssens

Université catholique de Louvain

View shared research outputs
Top Co-Authors

Avatar

Gustavo H. Olivera

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar

Jefferson Sorriaux

Université catholique de Louvain

View shared research outputs
Top Co-Authors

Avatar

Xavier Geets

Université catholique de Louvain

View shared research outputs
Top Co-Authors

Avatar

A. Barragan

Université catholique de Louvain

View shared research outputs
Top Co-Authors

Avatar

X. Geets

Cliniques Universitaires Saint-Luc

View shared research outputs
Top Co-Authors

Avatar

Hugo Palmans

National Physical Laboratory

View shared research outputs
Researchain Logo
Decentralizing Knowledge