E. Vagena
Aristotle University of Thessaloniki
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by E. Vagena.
Environmental Science & Technology | 2011
Olivier Masson; A. Baeza; J. Bieringer; K. Brudecki; S. Bucci; M. Cappai; Fernando P. Carvalho; O. Connan; C. Cosma; A. Dalheimer; D. Didier; G. Depuydt; L.E. De Geer; A. de Vismes; L. Gini; Flavia Groppi; K. Gudnason; R. Gurriaran; D. Hainz; Ó. Halldórsson; D. Hammond; O. Hanley; K. Holeý; Zs. Homoki; A. Ioannidou; K. Isajenko; M. Jankovic; C. Katzlberger; M. Kettunen; R. Kierepko
Radioactive emissions into the atmosphere from the damaged reactors of the Fukushima Dai-ichi nuclear power plant (NPP) started on March 12th, 2011. Among the various radionuclides released, iodine-131 ((131)I) and cesium isotopes ((137)Cs and (134)Cs) were transported across the Pacific toward the North American continent and reached Europe despite dispersion and washout along the route of the contaminated air masses. In Europe, the first signs of the releases were detected 7 days later while the first peak of activity level was observed between March 28th and March 30th. Time variations over a 20-day period and spatial variations across more than 150 sampling locations in Europe made it possible to characterize the contaminated air masses. After the Chernobyl accident, only a few measurements of the gaseous (131)I fraction were conducted compared to the number of measurements for the particulate fraction. Several studies had already pointed out the importance of the gaseous (131)I and the large underestimation of the total (131)I airborne activity level, and subsequent calculations of inhalation dose, if neglected. The measurements made across Europe following the releases from the Fukushima NPP reactors have provided a significant amount of new data on the ratio of the gaseous (131)I fraction to total (131)I, both on a spatial scale and its temporal variation. It can be pointed out that during the Fukushima event, the (134)Cs to (137)Cs ratio proved to be different from that observed after the Chernobyl accident. The data set provided in this paper is the most comprehensive survey of the main relevant airborne radionuclides from the Fukushima reactors, measured across Europe. A rough estimate of the total (131)I inventory that has passed over Europe during this period was <1% of the released amount. According to the measurements, airborne activity levels remain of no concern for public health in Europe.
Radiation Effects and Defects in Solids | 2016
P. Koseoglou; E. Vagena; S. Stoulos; M. Manolopoulou
ABSTRACT Neutron spectrum of the sub-critical nuclear assembly-reactor of Aristotle University of Thessaloniki was measured at three radial distances from the reactor core. The neutron activation technique was applied irradiating 15 thick foils – disc of various elements at each position. The data of 38 (n, γ), (n, p) and (n, α) reactions were analyzed for specific activity determination. Discs instead of foils were used due to the relevant low neutron flux, so the gamma self-absorption as well as the neutron self-shielding factors has been calculated using GEANT simulations in order to determine the activity induced. The specific activities calculated for all isotopes studied were the input to the SANDII code, which was built specifically for the neutron spectrum de-convolution when the neutron activation technique is used. For the optimization of the results a technique was applied in order to minimize the influence of the initial-“guessed” spectrum shape SANDII uses. The neutron spectrum estimated presents a peak in the regions of (i) thermal neutrons ranged between 0.001 and 1 eV peaking at neutron energy ∼0.1 eV and (ii) fast neutrons ranged between 0.1 and 20 MeV peaking at neutron energy ∼1.2 MeV. The reduction of thermal neutrons is higher than the fast one as the distance from the reactor core increases since thermal neutrons capture by natural U-fuel has higher cross section than the fast neutrons.
Journal of Physics: Conference Series | 2012
M. Manolopoulou; M. Fragopoulou; S. Stoulos; E. Vagena; W. Westmeier; M. Zamani
Helium filled proportional counters are widely used in the field of neutron detection and spectrometry. In this work the response of a commercially available He-3 counter is studied experimentally and calculated with Monte Carlo for the neutron energy range from 230 keV up to about 7 MeV. The calculated response of the system is used to determine neutron yield energy distribution emitted from an extended natU/Pb assembly irradiated with 1.6 GeV deuterons. The results are in acceptable agreement with the calculated neutron distribution with DCM-DEM code.
Journal of Environmental Radioactivity | 2011
M. Manolopoulou; E. Vagena; S. Stoulos; A. Ioannidou; C. Papastefanou
Journal of Radioanalytical and Nuclear Chemistry | 2012
M. Manolopoulou; S. Stoulos; A. Ioannidou; E. Vagena; C. Papastefanou
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2016
E. Vagena; S. Stoulos; M. Manolopoulou
Radiation Physics and Chemistry | 2016
E. Vagena; S. Stoulos; M. Manolopoulou
Atmospheric Environment | 2013
A. Ioannidou; E. Giannakaki; M. Manolopoulou; S. Stoulos; E. Vagena; C. Papastefanou; L. Gini; S. Manenti; Flavia Groppi
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2018
E. Vagena; Kyriaki Theodorou; S. Stoulos
Journal of Radioanalytical and Nuclear Chemistry | 2014
A. Ioannidou; E. M. Manolopoulou; S. Stoulos; E. Vagena; C. Papastefanou; M. Bonardi; Luigi Gini; Simone Manenti; Flavia Groppi