Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Eberhard Grube is active.

Publication


Featured researches published by Eberhard Grube.


Circulation | 2003

Randomized Study to Assess the Effectiveness of Slow- and Moderate-Release Polymer-Based Paclitaxel-Eluting Stents for Coronary Artery Lesions

Antonio Colombo; Janusz Drzewiecki; Adrian P. Banning; Eberhard Grube; Karl E. Hauptmann; Sigmund Silber; Dariusz Dudek; Stephen Fort; Francois Schiele; Krysztof Zmudka; Giulio Guagliumi; Mary E. Russell

Background—Early clinical studies demonstrated the feasibility of local paclitaxel delivery in reducing restenosis after treatment of de novo coronary lesions in small patient populations. Methods and Results—We conducted a randomized, double-blind trial of 536 patients at 38 medical centers evaluating slow-release (SR) and moderate-release (MR) formulations of a polymer-based paclitaxel-eluting stent (TAXUS) for revascularization of single, primary lesions in native coronary arteries. Cohort I compared TAXUS-SR with control stents, and Cohort II compared TAXUS-MR with a second control group. The primary end point was 6-month percent in-stent net volume obstruction measured by intravascular ultrasound. Secondary end points were 6-month angiographic restenosis and 6- and 12-month incidence of major adverse cardiac events, a composite of cardiac death, myocardial infarction, and repeat revascularization. At 6 months, percent net volume obstruction within the stent was significantly lower for TAXUS stents (7.9% SR and 7.8% MR) than for respective controls (23.2% and 20.5%; P <0.0001 for both). This corresponded with a reduction in angiographic restenosis from 17.9% to 2.3% in the SR cohort (P <0.0001) and from 20.2% to 4.7% in the MR cohort (P =0.0002). The incidence of major adverse cardiac events at 12 months was significantly lower (P =0.0192) in the TAXUS-SR (10.9%) and TAXUS-MR (9.9%) groups than in controls (22.0% and 21.4%, respectively), predominantly because of a significant reduction in repeat revascularization of the target lesion in TAXUS-treated patients. Conclusions—Compared with a bare metal stent, paclitaxel-eluting stents reduced in-stent neointimal formation and restenosis and improved 12-month clinical outcome of patients with single de novo coronary lesions.


Circulation | 2003

TAXUS I Six- and Twelve-Month Results From a Randomized, Double-Blind Trial on a Slow-Release Paclitaxel-Eluting Stent for De Novo Coronary Lesions

Eberhard Grube; Sigmund Silber; Karl Eugen Hauptmann; Ralf Mueller; Lutz Buellesfeld; Ulrich Gerckens; Mary E. Russell

Background—The TAXUS NIRx stent (Boston Scientific Corp) provides local delivery of paclitaxel via a slow-release polymer coating. The TAXUS I trial was the first in-human experience evaluating safety and feasibility of the TAXUS NIRx stent system compared with bare NIR stents (control) (Boston Scientific Corp) for treatment of coronary lesions. Methods and Results—The TAXUS I trial was a prospective, double-blind, three-center study randomizing 61 patients with de novo or restenotic lesions (≤12 mm) to receive a TAXUS (n=31) versus control (n=30) stent (diameter 3.0 or 3.5 mm). Demographics, lesion characteristics, clinical outcomes were comparable between the groups. The 30-day major adverse cardiac event (MACE) rate was 0% in both groups (P =NS). No stent thromboses were reported at 1, 6, 9, or 12 months. At 12 months, the MACE rate was 3% (1 event) in the TAXUS group and 10% (4 events in 3 patients) in the control group (P =NS). Six-month angiographic restenosis rates were 0% for TAXUS versus 10% for control (P =NS) patients. There were significant improvements in minimal lumen diameter (2.60±0.49 versus 2.19±0.65 mm), diameter stenosis (13.56±11.77 versus 27.23±16.69), and late lumen loss (0.36±0.48 versus 0.71±0.48 mm) in the TAXUS group (all P <0.01). No evidence of edge restenosis was seen in either group. Intravascular ultrasound analysis showed significant improvements in normalized neointimal hyperplasia in the TAXUS (14.8 mm3) group compared with the control group (21.6 mm3) (P <0.05). Conclusions—In this feasibility trial, the TAXUS slow-release stent was well tolerated and showed promise for treatment of coronary lesions, with significant reductions in angiographic and intravascular ultrasound measures of restenosis.


Circulation | 2006

Percutaneous Implantation of the CoreValve Self-Expanding Valve Prosthesis in High-Risk Patients With Aortic Valve Disease The Siegburg First-in-Man Study

Eberhard Grube; Jean Claude Laborde; Ulrich Gerckens; Thomas Felderhoff; Barthel Sauren; Lutz Buellesfeld; Ralf Mueller; Maurizio Menichelli; Thomas Andersen Schmidt; Bernfried Zickmann; Stein Iversen; Gregg W. Stone

Background— The morbidity and mortality of surgical aortic valve replacement are increased in elderly patients with multiple high-risk comorbid conditions. Therefore, a prospective, single-center, nonrandomized study was performed in high-risk patients with aortic valve disease to evaluate the feasibility and safety of percutaneous implantation of a novel self-expanding aortic valve bioprosthesis (CoreValve). Methods and Results— Symptomatic high-risk patients with an aortic valve area <1 cm2 were considered for enrollment. CoreValve implantation was performed under general anesthesia with extracorporeal support using the retrograde approach. Clinical follow-up and transthoracic echocardiography were performed after the procedure and at days 15 and 30 after device implantation to evaluate short-term patient and device outcomes. A total of 25 patients with symptomatic aortic valve stenosis (mean gradient before implantation, 44.2±10.8 mm Hg) and multiple comorbidities (median logistic EuroScore, 11.0%) were enrolled. Device success and procedural success were achieved in 22 (88%) and 21 (84%) patients, respectively. Successful device implantation resulted in a marked reduction in the aortic valve gradients (mean gradient after implantation, 12.4±3.0 mm Hg; P<0.0001). The mean aortic regurgitation grade was unchanged. Major in-hospital cardiovascular and cerebral events occurred in 8 patients (32%), including mortality in 5 patients (20%). Among 18 patients with device success surviving to discharge, no adverse events occurred within 30 days after leaving the hospital. Conclusions— Percutaneous implantation of the self-expanding CoreValve aortic valve prosthesis in high-risk patients with aortic stenosis with or without aortic regurgitation is feasible and, when successful, results in marked hemodynamic and clinical improvement.


Eurointervention | 2008

Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval

Nicolo Piazza; Eberhard Grube; Ulrich Gerckens; Peter den Heijer; Axel Linke; Olev Luha; Angelo Ramondo; Giampaolo Ussia; Peter Wenaweser; Stephan Windecker; Jean-Claude Laborde; Peter de Jaegere; Patrick W. Serruys

AIMS To describe the procedural performance and 30-day outcomes following implantation using the 18 Fr CoreValve Revalving System (CRS) as part of the multicentre, expanded evaluation registry, 1-year after obtaining CE mark approval. METHODS AND RESULTS Patients with symptomatic severe aortic stenosis and logistic Euroscore > or =15%, or age > or =75 years, or age > or =65 years associated with pre-defined risk factors, and for whom a physician proctor and a clinical specialist were in attendance during the implantation and who collected the clinical data, were included. From April 2007, to April 2008, 646 patients with a mean age of 81 +/- 6.6 years, mean aortic valve area 0.6 +/- 0.2 cm2, and logistic EuroSCORE of 23.1 +/- 13.8% were recruited. After valve implantation, the mean transaortic valve gradient decreased from 49.4 +/- 13.9 to 3 +/- 2 mmHg. All patients had paravalvular aortic regurgitation < or = grade 2. The rate of procedural success was 97%. The procedural mortality rate was 1.5%. At 30 days, the all-cause mortality rate (i.e, including procedural) was 8% and the combined rate of death, stroke and myocardial infarction was 9.3%. CONCLUSIONS The results of this study demonstrate the high rate of procedural success and a low 30-day mortality in a large cohort of high-risk patients undergoing transcatheter aortic valve implantation (TAVI) with the CRS.


European Heart Journal | 2010

Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis

Francesco Prati; Evelyn Regar; Gary S. Mintz; Eloisa Arbustini; Carlo Di Mario; Ik-Kyung Jang; Takashi Akasaka; Marco A. Costa; Giulio Guagliumi; Eberhard Grube; Yukio Ozaki; Fausto J. Pinto; Patrick W. Serruys

Optical coherence tomography (OCT) is a novel intravascular imaging modality, based on infrared light emission, that enables a high resolution arterial wall imaging, in the range of 10-20 microns. This feature of OCT allows the visualization of specific components of the atherosclerotic plaques. The aim of the present Expert Review Document is to address the methodology, terminology and clinical applications of OCT for qualitative and quantitative assessment of coronary arteries and atherosclerosis.


European Heart Journal | 2011

Transcatheter aortic valve implantation: first results from a multi-centre real-world registry

Ralf Zahn; Ulrich Gerckens; Eberhard Grube; Axel Linke; Horst Sievert; Holger Eggebrecht; Rainer Hambrecht; Stefan Sack; Karl Eugen Hauptmann; Gert Richardt; Hans-Reiner Figulla; Jochen Senges

AIMS Treatment of elderly symptomatic patients with severe aortic stenosis and co-morbidities is challenging. Transcatheter aortic valve interventions [balloon valvuloplasty and transcatheter aortic valve implantation (TAVI)] are evolving as alternative treatment options to surgical valve replacement. We report the first results of the prospective multi-centre German Transcatheter Aortic Valve Interventions-Registry. METHODS AND RESULTS Between January 2009 and December 2009, a total of 697 patients (81.4 ± 6.3 years, 44.2% males, and logistic EuroScore 20.5 ± 13.2%) underwent TAVI. Pre-operative aortic valve area was 0.6 ± 0.2 cm² with a mean transvalvular gradient of 48.7 ± 17.2 mmHg. Transcatheter aortic valve implantation was performed percutaneously in the majority of patients [666 (95.6%)]. Only 31 (4.4%) procedures were done surgically: 26 (3.7%) transapically and 5 (0.7%) transaortically. The Medtronic CoreValve™ prosthesis was used in 84.4%, whereas the Sapien Edwards™ prosthesis was used in the remaining cases. Technical success was achieved in 98.4% with a post-operative mean transaortic pressure gradient of 5.4 ± 6.2 mmHg. Any residual aortic regurgitation was observed in 72.4% of patients, with a significant aortic insufficiency (≥Grade III) in only 16 patients (2.3%). Complications included pericardial tamponade in 1.8% and stroke in 2.8% of patients. Permanent pacemaker implantation after TAVI became necessary in 39.3% of patients. In-hospital death rate was 8.2%, and the 30-day death rate 12.4%. CONCLUSION In this real-world registry of high-risk patients with aortic stenosis, TAVI had a high success rate and was associated with moderate in-hospital complications. However, careful patient selection and continued hospital selection seem crucial to maintain these results.


Circulation | 2005

Percutaneous recanalization of chronically occluded coronary arteries: A consensus document - Part II

Gregg W. Stone; Nicolaus Reifart; Issam Moussa; Angela Hoye; David A. Cox; Antonio Colombo; Donald S. Baim; Paul S. Teirstein; Bradley H. Strauss; Matthew R. Selmon; Gary S. Mintz; Osamu Katoh; Kazuaki Mitsudo; Takahiko Suzuki; Hideo Tamai; Eberhard Grube; Louis Cannon; David E. Kandzari; Mark Reisman; Robert S. Schwartz; Steven R. Bailey; George Dangas; Roxana Mehran; Alexander Abizaid; Jeffrey W. Moses; Martin B. Leon; Patrick W. Serruys

In Part I of this article, the definitions, prevalence, and clinical presentation of chronic total occlusions (CTOs) were reviewed, the histopathology of CTOs was examined, efforts to replicate human CTOs with experimental models were appraised, and the clinical relevance and rationale for CTO revascularization were evaluated.1 In Part II, we summarize the technical approach to and outcomes after percutaneous coronary intervention (PCI) of occluded coronary arteries, describe the novel devices and drugs approved and undergoing investigation for CTO recanalization, and conclude with practical perspectives on managing the patient with 1 or more chronic coronary occlusions. ### Patient Selection and Revascularization Strategies PCI of CTOs constitutes as many as 20% of all angioplasty procedures at selected centers,2 although a rate of &10% is more typical,3–6 suggesting that CTO angioplasty is attempted in 50 000 to 100 000 patients per year in the United States. Many more CTOs are present for which PCI is never attempted, representing one of the most common causes for referral to bypass surgery rather than PCI.6–8 Furthermore, a large proportion of patients with CTOs are managed medically, the prognosis of whom may vary depending on the extent of viable myocardium and ischemia, concomitant atherosclerosis in other coronary and noncoronary vascular territories, and other comorbid conditions. The decision to attempt PCI of a CTO (versus continued medical therapy or surgical revascularization) requires an individualized risk/benefit analysis, encompassing clinical, angiographic, and technical considerations. Clinically, the patient’s age, symptom severity, associated comorbidities (eg, diabetes mellitus and chronic renal insufficiency), and overall functional status are major determinants of treatment strategy. Angiographically, the extent and complexity of coronary artery disease (eg, single-vessel versus multivessel disease, single versus multiple total occlusions, likelihood for complete revascularization), left ventricular function, and the presence and degree of valvular heart disease should be considered. The technical probability of achieving …


Circulation | 2007

Incidence and Predictors of Drug-Eluting Stent Thrombosis During and After Discontinuation of Thienopyridine Treatment

Flavio Airoldi; Antonio Colombo; Nuccia Morici; Azeem Latib; John Cosgrave; Lutz Buellesfeld; Erminio Bonizzoni; Mauro Carlino; Ulrich Gerckens; Cosmo Godino; Gloria Melzi; Iassen Michev; Matteo Montorfano; Giuseppe Sangiorgi; Asif Qasim; Alaide Chieffo; Carlo Briguori; Eberhard Grube

Background— The need for prolonged aspirin and thienopyridine therapy and the risk of stent thrombosis (ST) remain as drawbacks associated with drug-eluting stents. Methods and Results— A prospective observational cohort study was conducted between June 2002 and January 2004 on 3021 patients consecutively and successfully treated in 5389 lesions with drug-eluting stents. Detailed patient information was collected on antiplatelet therapy. We analyzed the incidence of ST throughout the 18-month follow-up period and its relationship with thienopyridine therapy. ST occurred in 58 patients (1.9%) at 18 months. Forty-two patients (1.4%) experienced the event within 6 months of stent implantation. Acute myocardial infarction (fatal or nonfatal) occurred in 46 patients (79%) and death in 23 patients (39%) with ST. The median interval from discontinuation of thienopyridine therapy to ST was 13.5 days (interquartile range 5.2 to 25.7 days) for the first 6 months and 90 days (interquartile range 30 to 365 days) between 6 and 18 months. On multivariable analysis, the strongest predictor for ST within 6 months of stenting was discontinuation of thienopyridine therapy (hazard ratio, 13.74; 95% CI, 4.04 to 46.68; P<0.001). Thienopyridine discontinuation after 6 months did not predict the occurrence of ST (hazard ratio, 0.94; 95% CI, 0.30 to 2.98; P=0.92). Conclusions— Discontinuation of thienopyridine therapy was the major determinant of ST within the first 6 months, but insufficient information is available to determine whether there is benefit in continuing a thienopyridine beyond 6 months.


The New England Journal of Medicine | 2017

Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients

Michael J. Reardon; Nicolas M. Van Mieghem; Jeffrey J. Popma; Neal S. Kleiman; Lars Søndergaard; Mubashir Mumtaz; David H. Adams; G. Michael Deeb; Brijeshwar Maini; Hemal Gada; Stanley Chetcuti; Thomas G. Gleason; John Heiser; Rüdiger Lange; William Merhi; Jae K. Oh; Peter Skov Olsen; Nicolo Piazza; Mathew R. Williams; Stephan Windecker; Steven J. Yakubov; Eberhard Grube; Raj Makkar; Joon S. Lee; John V. Conte; Eric Vang; Hang Nguyen; Yanping Chang; Andrew S. Mugglin; Patrick W. J. C. Serruys

Background Although transcatheter aortic‐valve replacement (TAVR) is an accepted alternative to surgery in patients with severe aortic stenosis who are at high surgical risk, less is known about comparative outcomes among patients with aortic stenosis who are at intermediate surgical risk. Methods We evaluated the clinical outcomes in intermediate‐risk patients with severe, symptomatic aortic stenosis in a randomized trial comparing TAVR (performed with the use of a self‐expanding prosthesis) with surgical aortic‐valve replacement. The primary end point was a composite of death from any cause or disabling stroke at 24 months in patients undergoing attempted aortic‐valve replacement. We used Bayesian analytical methods (with a margin of 0.07) to evaluate the noninferiority of TAVR as compared with surgical valve replacement. Results A total of 1746 patients underwent randomization at 87 centers. Of these patients, 1660 underwent an attempted TAVR or surgical procedure. The mean (±SD) age of the patients was 79.8±6.2 years, and all were at intermediate risk for surgery (Society of Thoracic Surgeons Predicted Risk of Mortality, 4.5±1.6%). At 24 months, the estimated incidence of the primary end point was 12.6% in the TAVR group and 14.0% in the surgery group (95% credible interval [Bayesian analysis] for difference, ‐5.2 to 2.3%; posterior probability of noninferiority, >0.999). Surgery was associated with higher rates of acute kidney injury, atrial fibrillation, and transfusion requirements, whereas TAVR had higher rates of residual aortic regurgitation and need for pacemaker implantation. TAVR resulted in lower mean gradients and larger aortic‐valve areas than surgery. Structural valve deterioration at 24 months did not occur in either group. Conclusions TAVR was a noninferior alternative to surgery in patients with severe aortic stenosis at intermediate surgical risk, with a different pattern of adverse events associated with each procedure. (Funded by Medtronic; SURTAVI ClinicalTrials.gov number, NCT01586910.)


Circulation | 2009

Randomized Study of the Crush Technique Versus Provisional Side-Branch Stenting in True Coronary Bifurcations The CACTUS (Coronary Bifurcations: Application of the Crushing Technique Using Sirolimus-Eluting Stents) Study

Antonio Colombo; Ezio Bramucci; S. Saccà; Roberto Violini; Corrado Lettieri; Roberto Zanini; Imad Sheiban; Leonardo Paloscia; Eberhard Grube; Joachim Schofer; Leonardo Bolognese; Mario Orlandi; Giampaolo Niccoli; Azeem Latib; Flavio Airoldi

Background— Sirolimus-eluting stents have been reported to be effective in the treatment of coronary bifurcations. Still, it has not been fully clarified which strategy would provide the best results with true bifurcation lesions. Methods and Results— The CACTUS trial (Coronary bifurcations: Application of the Crushing Technique Using Sirolimus-eluting stents) is a prospective, randomized, multicenter study comparing 2 different techniques of stenting, with mandatory final kissing-balloon inflation, in true bifurcations: (1) elective “crush” stenting and (2) stenting of only the main branch, with provisional side-branch T-stenting. From August 2004 to June 2007, 350 patients were enrolled in 12 European centers. The primary angiographic end point was the in-segment restenosis rate, and the primary clinical end point was the occurrence of major adverse cardiac events (cardiac death, myocardial infarction, or target-vessel revascularization) at 6 months. At 6 months, angiographic restenosis rates were not different between the crush group (4.6% and 13.2% in the main branch and side branch, respectively) and the provisional stenting group (6.7% and 14.7% in the main branch and side branch, respectively; P=NS). Additional stenting on the side branch in the provisional stenting group was required in 31% of lesions. Rates of major adverse cardiac events were also similar in the 2 groups (15.8% in the crush group versus 15% in the provisional stenting group, P=NS). Conclusions— In most bifurcations with a significant stenosis in both branches, a provisional strategy of stenting the main branch only is effective, with the need to implant a second stent on the side branch occurring in approximately one third of cases. The implantation of 2 stents does not appear to be associated with a higher incidence of adverse events at 6 months.

Collaboration


Dive into the Eberhard Grube's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Georg Nickenig

University Hospital Bonn

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Nikos Werner

University Hospital Bonn

View shared research outputs
Top Co-Authors

Avatar

Antonio Colombo

Vita-Salute San Raffaele University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge