Eder Alberto Sigua-Rodriguez
State University of Campinas
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Eder Alberto Sigua-Rodriguez.
International Journal of Dentistry | 2014
Eder Alberto Sigua-Rodriguez; Renato da Costa Ribeiro; Ana Caroline Brito; Natalia Alvarez-Pinzon; Jose Ricardo de Albergaria-Barbosa
Bisphosphonates (BPs) are a class of drugs used to treat osteoporosis and malignant bone metastasis. BPs show high binding capacity to the bone matrix, especially in sites of active bone metabolism. The American Society for Bone and Mineral Research defines BRONJ as “an area of exposed bone in the maxillofacial region that has not healed within 8 weeks after identification by a healthcare provider in a patient who is receiving or has been exposed to a bisphosphonate and has not had radiation therapy to the craniofacial region.” Bisphosphonate-related osteonecrosis of the jaw (BRONJ) can adversely affect quality of life, as it may produce significant morbidity. The American Association of Oral and Maxillofacial Surgeons (AAOMS) considers as vitally important that information on BRONJ be disseminated to other dental and medical specialties. The purpose of this work is to offer a perspective on how dentists should manage patients on BPs, to show the benefits of accurately diagnosing BRONJ, and to present diagnostic aids and treatments strategies for the condition.
Case reports in otolaryngology | 2015
Eder Alberto Sigua-Rodriguez; Douglas Rangel Goulart; Luciana Asprino; Afonso Celso de Moraes Manzano
Lingual thyroid gland is a rare clinical entity. The presence of an ectopic thyroid gland located at the base of the tongue may be presented with symptoms like dysphagia, dysphonia, and upper airway obstruction. We are introducing a case of an 8-year-old girl who had lingual thyroid that presented dysphagia and foreign body sensation in the throat. The diagnostic was reached with clinical examination, thyroid scintigraphy with Tc99m and ultrasound. A laryngoscopy was performed which confirmed a spherical mass at base of tongue. Investigation should include thyroid function tests. In this case we observed subclinical hypothyroidism. There are different types of surgical approaches for the treatment of this condition; however, the treatment with Levothyroxine Sodium allowed the stabilization of TSH levels and clinical improvement of symptoms in a follow-up of 2 years.
International Journal of Dentistry | 2014
Evandro Portela Figueirêdo; Eder Alberto Sigua-Rodriguez; Marcele Jardim Pimentel; Ana Regina Oliveira Moreira; Mauro Antônio de Arruda Nóbilo; Jose Ricardo de Albergaria-Barbosa
The aim of this study was to evaluate by photoelastic analysis stress distribution on short and long implants of two dental implant systems with 2-unit implant-supported fixed partial prostheses of 8 mm and 13 mm heights. Sixteen photoelastic models were divided into 4 groups: I: long implant (5 × 11 mm) (Neodent), II: long implant (5 × 11 mm) (Bicon), III: short implant (5 × 6 mm) (Neodent), and IV: short implants (5 × 6 mm) (Bicon). The models were positioned in a circular polariscope associated with a cell load and static axial (0.5 Kgf) and nonaxial load (15°, 0.5 Kgf) were applied to each group for both prosthetic crown heights. Three-way ANOVA was used to compare the factors implant length, crown height, and implant system (α = 0.05). The results showed that implant length was a statistically significant factor for both axial and nonaxial loading. The 13 mm prosthetic crown did not result in statistically significant differences in stress distribution between the implant systems and implant lengths studied, regardless of load type (P > 0.05). It can be concluded that short implants showed higher stress levels than long implants. Implant system and length was not relevant factors when prosthetic crown height were increased.
Journal of Craniofacial Surgery | 2017
Eder Alberto Sigua-Rodriguez; Douglas Rangel Goulart; Zarina Tatia Santos; Natalia Alvarez-Pinzon; Sergio Olate; Jose Ricardo de Albergaria-Barbosa
Objective: Auricular prostheses are artificial substitutes for facial defects. The retention of these has often been a problem. This study aimed to evaluate the mechanical behavior of 3 retained auricular prosthetic connections when submitted to a mechanical cycling test. Materials and Methods: Twelve samples with installed implants were obtained and divided into 3 groups according to their retention system with 4 samples in each group. I: bar-clip system; II: magnet system; and III: ball/o-ring system. Each of samples was submitted to the pull-out test during 3240 cycles (f = 0.5 Hz) to determine its tensile strength. The mechanical cycling test was performed using the servo-hydraulic machine MTS 810-Flex Test 40 (Eden Prairie, MN) that had a 2.5 mm shift at a 10 mm/s velocity. The retaining strength for each of the samples was obtained at 7 intervals. Results: The tensile strength for the group retained by the bar-clip system (29.60 N) was higher with statistically significant difference (P < 0.05) when compared with the group retained by the ball/o-ring system (9.41 N) and magnets system (8.61 N) for all periods assessed. The ball/o-ring system showed loss of retention during the fatigue test (Kruskal–Wallis, chi-squared = 17.28; P < 0.01). Conclusions: The evaluated systems showed a tensile strength compatible with the clinical use and no fractures of the components were observed.
Journal of Craniofacial Surgery | 2017
Eder Alberto Sigua-Rodriguez; Douglas Rangel Goulart; Afonso Celso de Moraes Manzano; Luciana Asprino
Malignant fibrous histiocytoma is a sarcoma with rare occurrence in the oral and maxillofacial region; surgery is the most reliable treatment. Inadequate resection of the sarcoma on the oral and maxillofacial region is associated with a high incidence of local recurrence and a poor prognosis. Only few patients of malignant fibrous histiocytoma of the malar region have been previously reported in the literature. The authors report a new patient of malignant fibrous histiocytoma on the right malar region that treated a complete tumor surgical excision without lymph node dissection. Examination of the resected specimen revealed that the tumor was completely removed.Malignant fibrous histiocytoma is a sarcoma with rare occurrence in the oral and maxillofacial region; surgery is the most reliable treatment. Inadequate resection of the sarcoma on the oral and maxillofacial region is associated with a high incidence of local recurrence and a poor prognosis. Only few patients of malignant fibrous histiocytoma of the malar region have been previously reported in the literature. The authors report a new patient of malignant fibrous histiocytoma on the right malar region that treated a complete tumor surgical excision without lymph node dissection. Examination of the resected specimen revealed that the tumor was completely removed.
Journal of The Korean Association of Oral and Maxillofacial Surgeons | 2016
Antonio Lanata-Flores; Eder Alberto Sigua-Rodriguez; Douglas Rangel Goulart; Veber Luiz Bomfim-Azevedo; Sergio Olate; Jose Ricardo de Albergaria-Barbosa
Objectives This study aimed to evaluate the stability of prosthetic screws from three types of craniofacial prostheses retention systems (bar-clip, ball/O-ring, and magnet) when submitted to mechanical cycling. Materials and Methods Twelve models of acrylic resin were used with implants placed 20 mm from each other and separated into three groups: (1) bar-clip (Sistema INP, São Paulo, Brazil), (2) ball/O-ring (Sistema INP), and (3) magnet (Metalmag, São Paulo, Brazil), with four samples in each group. Each sample underwent a mechanical cycling removal and insertion test (f=0.5 Hz) to determine the torque and the detorque values of the retention screws. A servo-hydraulic MTS machine (810-Flextest 40; MTS Systems, Eden Prairie, MN, USA) was used to perform the cycling with 2.5 mm and a displacement of 10 mm/s. The screws of the retention systems received an initial torque of 30 Ncm and the torque values required for loosening the screw values were obtained in three cycles (1,080, 2,160, and 3,240). The screws were retorqued to 30 Ncm before each new cycle. Results The sample was composed of 24 screws grouped as follows: bar-clip (n=8), ball/O-ring (n=8), and magnet (n=8). There were significant differences between the groups, with greater detorque values observed in the ball/O-ring group when compared to the bar-clip and magnet groups for the first cycle. However, the detorque value was greater in the bar-clip group for the second cycle. Conclusion The results of this study indicate that all prosthetic screws will loosen slightly after an initial tightening torque, also the bar-clip retention system demonstrated greater loosening of the screws when compared with ball/O-ring and magnet retention systems.
The Open Dentistry Journal | 2015
Gabriel Leonardo Magrin; Eder Alberto Sigua-Rodriguez; Douglas Rangel Goulart; Luciana Asprino
The piezosurgery has been used with increasing frequency and applicability by health professionals, especially those who deal with dental implants. The concept of piezoelectricity has emerged in the nineteenth century, but it was applied in oral surgery from 1988 by Tomaso Vercellotti. It consists of an ultrasonic device able to cut mineralized bone tissue, without injuring the adjacent soft tissue. It also has several advantages when compared to conventional techniques with drills and saws, such as the production of a precise, clean and low bleed bone cut that shows positive biological results. In dental implants surgery, it has been used for maxillary sinus lifting, removal of bone blocks, distraction osteogenesis, lateralization of the inferior alveolar nerve, split crest of alveolar ridge and even for dental implants placement. The purpose of this paper is to discuss the use of piezosurgery in bone augmentation procedures used previously to dental implants placement.
Journal of Craniofacial Surgery | 2018
Douglas Rangel Goulart; Eder Alberto Sigua-Rodriguez; Rodrigo Fariña; Sergio Olate
Journal of Cranio-maxillofacial Surgery | 2018
Eder Alberto Sigua-Rodriguez; Raquel Correia de Medeiros; Douglas Rangel Goulart; Veber Luiz Bomfim-Azevedo; Sergio Olate; Jose Ricardo de Albergaria-Barbosa
International journal of odontostomatology | 2018
Natalia Alvarez-Pinzon; Eder Alberto Sigua-Rodriguez; Douglas Rangel Goulart; Sergio Olate; Gustavo Jacobucci Farah; Liogi Iwaki-Filho