Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Edgar Gutierrez is active.

Publication


Featured researches published by Edgar Gutierrez.


Lab on a Chip | 2008

Microfluidic devices for studies of shear-dependent platelet adhesion

Edgar Gutierrez; Brian G. Petrich; Sanford J. Shattil; Mark H. Ginsberg; Alex Groisman; Ana Kasirer-Friede

Adhesion of platelets to blood vessel walls is a shear stress dependent process that promotes arrest of bleeding and is mediated by the interaction of receptors expressed on platelets with various extracellular matrix (ECM) proteins that may become exposed upon vascular injury. Studies of dynamic platelet adhesion to ECM-coated substrates in conventional flow chambers require substantial fluid volumes and are difficult to perform with blood samples from a single laboratory mouse. Here we report dynamic platelet adhesion assays in two new microfluidic devices made of PDMS. Small cross-sections of the flow chambers in the devices reduce the blood volume requirements to <100 microl per assay, making the assays compatible with samples of whole blood obtained from a single mouse. One device has an array of 8 flow chambers with shear stress varying by a factor of 1.93 between adjacent chambers, covering a 100-fold range from low venous to arterial. The other device allows simultaneous high-resolution fluorescence imaging of dynamic adhesion of platelets from two different blood samples. Adhesion of platelets in the devices to three common ECM substrate coatings was verified to conform with published results. The devices were subsequently used to study the roles of extracellular and intracellular domains of integrin alphaIIbbeta3, a platelet receptor that is a central mediator of platelet aggregation and thrombus formation. The study involved wild-type mice and two genetically modified mouse strains and showed that the absence of the integrin impaired adhesion at all shear stresses, whereas a mutation in its intracellular domain reduced the adhesion only at moderate and high stresses. Because of small sample volumes required, the devices could be employed in research with genetically-modified model organisms and for adhesion tests in clinical settings with blood from neonates.


Nature Cell Biology | 2011

Protein Kinase A Governs a RhoA-RhoGDI Protrusion-Retraction Pacemaker in Migrating Cells

Eugene Tkachenko; Mohsen Sabouri-Ghomi; Olivier Pertz; Chungho Kim; Edgar Gutierrez; Matthias Machacek; Alex Groisman; Gaudenz Danuser; Mark H. Ginsberg

The cyclical protrusion and retraction of the leading edge is a hallmark of many migrating cells involved in processes such as development, inflammation and tumorigenesis. The molecular identity of the signalling mechanisms that control these cycles has remained unknown. Here, we used live-cell imaging of biosensors to monitor spontaneous morphodynamic and signalling activities, and employed correlative image analysis to examine the role of cyclic-AMP-activated protein kinase A (PKA) in protrusion regulation. PKA activity at the leading edge is closely synchronized with rapid protrusion and with the activity of RhoA. Ensuing PKA phosphorylation of RhoA and the resulting increased interaction between RhoA and RhoGDI (Rho GDP-dissociation inhibitor) establish a negative feedback mechanism that controls the cycling of RhoA activity at the leading edge. Thus, cooperation between PKA, RhoA and RhoGDI forms a pacemaker that governs the morphodynamic behaviour of migrating cells.


Nature | 2012

/`Slings/' enable neutrophil rolling at high shear

Prithu Sundd; Edgar Gutierrez; Ekaterina K. Koltsova; Yoshihiro Kuwano; Satoru Fukuda; Maria K. Pospieszalska; Alex Groisman; Klaus Ley

Most leukocytes can roll along the walls of venules at low shear stress (1 dyn cm−2), but neutrophils have the ability to roll at tenfold higher shear stress in microvessels in vivo. The mechanisms involved in this shear-resistant rolling are known to involve cell flattening and pulling of long membrane tethers at the rear. Here we show that these long tethers do not retract as postulated, but instead persist and appear as ‘slings’ at the front of rolling cells. We demonstrate slings in a model of acute inflammation in vivo and on P-selectin in vitro, where P-selectin-glycoprotein-ligand-1 (PSGL-1) is found in discrete sticky patches whereas LFA-1 is expressed over the entire length on slings. As neutrophils roll forward, slings wrap around the rolling cells and undergo a step-wise peeling from the P-selectin substrate enabled by the failure of PSGL-1 patches under hydrodynamic forces. The ‘step-wise peeling of slings’ is distinct from the ‘pulling of tethers’ reported previously. Each sling effectively lays out a cell-autonomous adhesive substrate in front of neutrophils rolling at high shear stress during inflammation.


Lab on a Chip | 2009

Fine temporal control of the medium gas content and acidity and on-chip generation of series of oxygen concentrations for cell cultures

Mark E. Polinkovsky; Edgar Gutierrez; Andre Levchenko; Alex Groisman

We describe the design, operation, and applications of two microfluidic devices that generate series of concentrations of oxygen, [O(2)], by on-chip gas mixing. Both devices are made of polydimethylsiloxane (PDMS) and have two layers of channels, the flow layer and the gas layer. By using in-situ measurements of [O(2)] with an oxygen-sensitive fluorescent dye, we show that gas diffusion through PDMS leads to equilibration of [O(2)] in an aqueous solution in the flow layer with [O(2)] in a gas injected into the gas layer on a time scale of approximately 1 sec. Injection of carbon dioxide into the gas layer causes the pH in the flow layer to drop within approximately 0.5 sec. Gas-mixing channel networks of both devices generate series of 9 gas mixtures with different [O(2)] from two gases fed to the inlets, thus creating regions with 9 different [O(2)] in the flow layer. The first device generates nitrogen-oxygen mixtures with [O(2)] varying linearly between 0 and 100%. The second device generates nitrogen-air mixtures with [O(2)] varying exponentially between 0 and 20.9%. The flow layers of the devices are designed for culturing bacteria in semi-permeable microchambers, and the second device is used to measure growth curves of E. coli colonies at 9 different [O(2)] in a single experiment. The cell division rates at [O(2)] of 0, 0.2, and 0.5% are found to be significantly different, further validating the capacity of the device to set [O(2)] in the flow layer with high precision and resolution. The degree of control of [O(2)] achieved in the devices and the robustness with respect to oxygen consumption due to respiration would be difficult to match in a traditional large-scale culture. The proposed devices and technology can be used in research on bacteria and yeast under microaerobic conditions and on mammalian cells under hypoxia.


Lab on a Chip | 2009

An easy to assemble microfluidic perfusion device with a magnetic clamp

Eugene Tkachenko; Edgar Gutierrez; Mark H. Ginsberg; Alex Groisman

We have built and characterized a magnetic clamp for reversible sealing of PDMS microfluidic chips against cover glasses with cell cultures and a microfluidic chip for experiments on shear stress response of endothelial cells. The magnetic clamp exerts a reproducible uniform pressure on the microfluidic chip, achieving fast and reliable sealing for liquid pressures up to 40 kPa inside the chip with <10% deformations of microchannels and minimal variations of the substrate shear stress in perfusion flow. The microfluidic chip has 8 test regions with the substrate shear stress varying by a factor of 2 between each region, thus covering a 128-fold range from low venous to arterial. The perfusion is driven by differential pressure, which makes it possible to create pulsatile flows mimicking pulsing in the vasculature. The setup is tested by 15-40 hours perfusions over endothelial monolayers with shear stress in the range of 0.07-9 dyn/cm(2). Excellent cell viability at all shear stresses and alignment of cells along the flow at high shear stresses are repeatedly observed. A scratch wound healing assay under a shear flow is demonstrated and cell migration velocities are measured. Transfection of cells with a fluorescent protein is performed, and migrating fluorescent cells are imaged at a high resolution under shear flow in real time. The magnetic clamp can be closed with minimal mechanical perturbation to cells on the substrate and used with a variety of microfluidic chips for experiments with adherent and non-adherent cells.


PLOS ONE | 2011

Acute Drug Treatment in the Early C. elegans Embryo

Ana C. de Carvalho; Sara K. Olson; Edgar Gutierrez; Kelly Zhang; Lisa B. Noble; Esther Zanin; Arshad Desai; Alex Groisman; Karen Oegema

Genetic and genome-wide RNAi approaches available in C. elegans, combined with tools for visualizing subcellular events with high-resolution, have led to increasing adoption of the early C. elegans embryo as a model for mechanistic and functional genomic analysis of cellular processes. However, a limitation of this system has been the impermeability of the embryo eggshell, which has prevented the routine use of small molecule inhibitors. Here, we present a method to permeabilize and immobilize embryos for acute inhibitor treatment in conjunction with live imaging. To identify a means to permeabilize the eggshell, we used a dye uptake assay to screen a set of 310 candidate genes defined by a combination of bioinformatic criteria. This screen identified 20 genes whose inhibition resulted in >75% eggshell permeability, and 3 that permeabilized embryos with minimal deleterious effects on embryo production and early embryonic development. To mount permeabilized embryos for acute drug addition in conjunction with live imaging, we combined optimized inhibition of one of these genes with the use of a microfabricated chamber that we designed. We demonstrate that these two developments enable the temporally controlled introduction of inhibitors for mechanistic studies. This method should also open new avenues of investigation by allowing profiling and specificity-testing of inhibitors through comparison with genome-wide phenotypic datasets.


Nature Methods | 2010

Quantitative dynamic footprinting microscopy reveals mechanisms of neutrophil rolling

Prithu Sundd; Edgar Gutierrez; Maria K. Pospieszalska; Hong Zhang; Alex Groisman; Klaus Ley

We introduce quantitative dynamic footprinting microscopy to resolve neutrophil rolling on P-selectin. We observed that the footprint of a rolling neutrophil was fourfold larger than previously thought, and that P-selectin–PSGL-1 bonds were relaxed at the leading edge of the rolling cell, compressed under the cell center, and stretched at the trailing edge. Each rolling neutrophil formed three to four long tethers that extended up to 16 μm behind the rolling cell.


Circulation Research | 2008

Localized α4 Integrin Phosphorylation Directs Shear Stress–Induced Endothelial Cell Alignment

Lawrence E. Goldfinger; Eleni Tzima; Rebecca A. Stockton; William B. Kiosses; Kayoko Kinbara; Eugene Tkachenko; Edgar Gutierrez; Alex Groisman; Phu Nguyen; Shu Chien; Mark H. Ginsberg

Vascular endothelial cells respond to laminar shear stress by aligning in the direction of flow, a process which may contribute to atheroprotection. Here we report that localized &agr;4 integrin phosphorylation is a mechanism for establishing the directionality of shear stress–induced alignment in microvascular endothelial cells. Within 5 minutes of exposure to a physiological level of shear stress, endothelial &agr;4 integrins became phosphorylated on Ser988. In wounded monolayers, phosphorylation was enhanced at the downstream edges of cells relative to the source of flow. The shear-induced &agr;4 integrin phosphorylation was blocked by inhibitors of cAMP-dependent protein kinase A (PKA), an enzyme involved in the alignment of endothelial cells under prolonged shear. Moreover, shear-induced localized activation of the small GTPase Rac1, which specifies the directionality of endothelial alignment, was similarly blocked by PKA inhibitors. Furthermore, endothelial cells bearing a nonphosphorylatable &agr;4(S988A) mutation failed to align in response to shear stress, thus establishing &agr;4 as a relevant PKA substrate. We thereby show that shear-induced PKA-dependent &agr;4 integrin phosphorylation at the downstream edge of endothelial cells promotes localized Rac1 activation, which in turn directs cytoskeletal alignment in response to shear stress.


PLOS ONE | 2011

Measurements of Elastic Moduli of Silicone Gel Substrates with a Microfluidic Device

Edgar Gutierrez; Alex Groisman

Thin layers of gels with mechanical properties mimicking animal tissues are widely used to study the rigidity sensing of adherent animal cells and to measure forces applied by cells to their substrate with traction force microscopy. The gels are usually based on polyacrylamide and their elastic modulus is measured with an atomic force microscope (AFM). Here we present a simple microfluidic device that generates high shear stresses in a laminar flow above a gel-coated substrate and apply the device to gels with elastic moduli in a range from 0.4 to 300 kPa that are all prepared by mixing two components of a transparent commercial silicone Sylgard 184. The elastic modulus is measured by tracking beads on the gel surface under a wide-field fluorescence microscope without any other specialized equipment. The measurements have small and simple to estimate errors and their results are confirmed by conventional tensile tests. A master curve is obtained relating the mixing ratios of the two components of Sylgard 184 with the resulting elastic moduli of the gels. The rigidity of the silicone gels is less susceptible to effects from drying, swelling, and aging than polyacrylamide gels and can be easily coated with fluorescent tracer particles and with molecules promoting cellular adhesion. This work can lead to broader use of silicone gels in the cell biology laboratory and to improved repeatability and accuracy of cell traction force microscopy and rigidity sensing experiments.


PLOS ONE | 2012

Innate non-specific cell substratum adhesion.

William F. Loomis; Danny Fuller; Edgar Gutierrez; Alex Groisman; Wouter-Jan Rappel

Adhesion of motile cells to solid surfaces is necessary to transmit forces required for propulsion. Unlike mammalian cells, Dictyostelium cells do not make integrin mediated focal adhesions. Nevertheless, they can move rapidly on both hydrophobic and hydrophilic surfaces. We have found that adhesion to such surfaces can be inhibited by addition of sugars or amino acids to the buffer. Treating whole cells with αlpha-mannosidase to cleave surface oligosaccharides also reduces adhesion. The results indicate that adhesion of these cells is mediated by van der Waals attraction of their surface glycoproteins to the underlying substratum. Since glycoproteins are prevalent components of the surface of most cells, innate adhesion may be a common cellular property that has been overlooked.

Collaboration


Dive into the Edgar Gutierrez's collaboration.

Top Co-Authors

Avatar

Alex Groisman

University of California

View shared research outputs
Top Co-Authors

Avatar

Klaus Ley

University of Virginia

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Prithu Sundd

University of Pittsburgh

View shared research outputs
Top Co-Authors

Avatar

Maria K. Pospieszalska

La Jolla Institute for Allergy and Immunology

View shared research outputs
Top Co-Authors

Avatar

Alex Marki

La Jolla Institute for Allergy and Immunology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge