Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Edwin Lamers is active.

Publication


Featured researches published by Edwin Lamers.


Biomaterials | 2010

The influence of nanoscale grooved substrates on osteoblast behavior and extracellular matrix deposition

Edwin Lamers; X.F. Walboomers; Maciej Domanski; J. te Riet; F.C.M.J.M. van Delft; Regina Lüttge; Aloysius Johannes Antonius Winnubst; Johannes G.E. Gardeniers; John A. Jansen

To fight bone diseases characterized by poor bone quality like osteoporosis and osteoarthritis, as well as in reconstructive surgery, there is a need for a new generation of implantable biomaterials. It is envisioned that implant surfaces can be improved by mimicking the natural extracellular matrix of bone tissue, which is highly a organized nano-composite. In this study we aimed to get a better understanding of osteoblast response to nanometric grooved substrates varying in height, width and spacing. A throughput screening biochip was created using electron beam lithography. Subsequently, uniform large-scale nanogrooved substrates were created using laser interference lithography and reactive ion etching. Results showed that osteoblasts were responsive to nanopatterns down to 75 nm in width and 33nm in depth. SEM and TEM studies showed that an osteoblast-driven calcium phosphate (CaP) mineralization was observed to follow the surface pattern dimensions. Strikingly, aligned mineralization was found on even smaller nanopatterns of 50 nm in width and 17 nm in depth. A single cell based approach for real time PCR demonstrated that osteoblast-specific gene expression was increased on nanopatterns relative to a smooth control. The results indicate that nanogrooves can be a very promising tool to direct the bone response at the interface between an implant and the bone tissue.


Biomaterials | 2010

The interaction between nanoscale surface features and mechanical loading and its effect on osteoblast-like cells behavior

L. Prodanov; J. te Riet; Edwin Lamers; Maciej Domanski; Regina Lüttge; J.J.W.A. van Loon; John A. Jansen; X.F. Walboomers

Osteoblasts respond to mechanical stimulation by changing morphology, gene expression and matrix mineralization. Introducing surface topography on biomaterials, independently of mechanical loading, has been reported to give similar effects. In the current study, using a nanotextured surface, and mechanical loading, we aimed to develop a multi-factorial model in which both parameters interact. Mechanical stimulation to osteoblast-like cells was applied by longitudinal stretch in parallel direction to the nanotexture (300 nm wide and 60 nm deep grooves), with frequency of 1 Hz and stretch magnitude varying from 1% to 8%. Scanning electron microscopy showed that osteoblast-like cells subjected to mechanical loading oriented perpendicularly to the stretch direction. When cultured on nanotextured surfaces, cells aligned parallel to the texture. However, the parallel cell direction to the nanotextured surface was lost and turned to perpendicular when parallel stretch to the nanotexture, greater than 3% was applied to the cells. This phenomenon could not be achieved when a texture with micro-sized dimensions was used. Moreover, a significant synergistic effect on upregulation of fibronectin and Cfba was observed when dual stimulation was used. These findings can lead to a development of new biomimetic materials that can guide morphogenesis in tissue repair and bone remodeling.


Nanomedicine: Nanotechnology, Biology and Medicine | 2012

In vitro and in vivo evaluation of the inflammatory response to nanoscale grooved substrates

Edwin Lamers; X. Frank Walboomers; Maciej Domanski; L. Prodanov; Jacoline Melis; Regina Lüttge; Louis Winnubst; James M. Anderson; Han Gardeniers; John A. Jansen

The immune response to an implanted biomaterial is orchestrated by macrophages. In this study various nanogrooved patterns were created by using laser interference lithography and reactive ion etching. The created nanogrooves mimic the natural extracellular matrix environment. Macrophage cell culture demonstrated that interleukin 1β and TNF-α cytokine production were upregulated on nanogrooved substrates. In vivo subcutaneous implantation in a validated mouse cage model for 14 days demonstrated that nanogrooves enhanced and guided cell adhesion, and few multinucleated cells were formed. In agreement with the in vitro results, cytokine production was found to be nanogroove dependent, as interleukin 1β, TNF-α, TGF-β and osteopontin became upregulated. The results indicate that biomaterial surface texturing, especially at the nanometric scale, can be used to control macrophage activation to induce a wound healing response, rather than a profound inflammatory response. From the Clinical Editor: The authors investigate various nano-grooved patterns that mimic the natural extracellular matrix environment and demonstrate (both in macrophage cultures and in vivo) that interleukin 1β and TNF-α cytokine production is dependent upon surface texturing at the nanometric scale. They propose that modified surfaces may trigger macrophage activation to promote a wound healing response.


Biomaterials Science | 2013

Understanding the role of nano-topography on the surface of a bone-implant

Alexey Klymov; L. Prodanov; Edwin Lamers; John A. Jansen; X. Frank Walboomers

Bone-implant material development is proceeding at a high pace, and has shifted from straightforward biomaterial testing to more advanced cell-targeted approaches for surface modification and design. It has been long known that cells can recognize and respond to topographical features by changing their morphology and behavior. The progress in surface analytical devices, as well as in techniques for production of topographical features on the nanometer scale allow for the characterization of natural tissues and the reproduction of biomimetic nanofeatures in material surfaces. In this review some of the most common surface-characterization and surface-manufacturing techniques will be addressed and results from in vitro and in vivo studies will be presented. Knowledge on biomaterial nanotopography can be exploited for active stimulation and control of cellular behavior like attachment, migration, spreading, gene expression, proliferation, differentiation and secretion of matrix components.


Biomaterials | 2013

The effect of nanometric surface texture on bone contact to titanium implants in rabbit tibia

L. Prodanov; Edwin Lamers; Maciej Domanski; Regina Lüttge; John A. Jansen; X.F. Walboomers

Designing biomaterial surfaces to control the reaction of the surrounding tissue is still considered to be a primary issue, which needs to be addressed systematically. Although numerous in vitro studies have described different nano-metrically textured substrates capable to influence bone cellular response, in vivo studies validating this phenomenon have not been reported. In this study, nano-grooved silicon stamps were produced by laser interference lithography (LIL) and reactive ion etching (RIE) and were subsequently transferred onto the surface of 5 mm diameter Titanium (Ti) discs by nanoimprint lithography (NIL). Patterns with pitches of 1000 nm (500 nm ridge and groove, 150 nm depth), 300 nm (150 nm ridge and groove, 120 nm depth; as well as a 1:3 ratio of 75 nm ridge and 225 nm groove, 120 nm depth) and 150 nm (75 nm ridge and groove, 30 nm depth) were created. These samples were implanted in a rabbit tibia cortical bone. Histological evaluation and histomorphometric measurements were performed, comparing each sample to conventional grit-blasted/acid-etched (GAE) titanium controls. Results showed a significantly higher bone-to-implant contact at 4 weeks for the 300 nm (1:3) specimens, compared to GAE (p = 0.006). At 8 weeks, there was overall more bone contact compared to 4 weeks. However, no significant differences between the nano-textured samples and the GAE occurred. Further studies will need to address biomechanical testing and the use of trabecular bone models.


Clinical Oral Implants Research | 2014

In vivo comparison between laser-treated and grit blasted/acid etched titanium

L. Prodanov; Edwin Lamers; J.G.C. Wolke; R. Huiberts; John A. Jansen; X.F. Walboomers

OBJECTIVE Laser profiling of titanium has been of considerable interest in the field of oral implantology. However, very few pre-clinical and clinical studies have been performed with laser-treated implants, especially focusing on isotropic roughness topography. The aim of the study was to compare the cortical bone response of Ti-implants discs treated with pico-sec pulsed laser (LAS) and conventional grit-blasted/acid-etched (GAE) method. MATERIALS AND METHODS Prior to the in vivo experiment, in vitro cell viability testing of the LAS surface treatment was preformed. Then, 5 mm diameter Titanium (Ti) discs treated with LAS and GAE method were implanted in a pre-validated rabbit tibia cortical bone model and assessed with histology and histomorphometric measurements. In total, eight New Zealand White adult female rabbits were used. RESULTS The in vitro cell viability testing with osteoblast-like cells confirmed cytocompatibility of the LAS surface treatment. Further, the rabbit experiment demonstrated a bone-to-implant contact of 68% (±17) for the laser-treated discs and 49% (±21) for the GAE discs 8 weeks after the implantation, which was statistically not different. CONCLUSION Laser surface treatment gives the same results to the grit-blasting/acid-etched method and thus is a valid alternative to conventional roughening for dental implant materials.


European Cells & Materials | 2010

The influence of nanoscale topographical cues on initial osteoblast morphology and migration

Edwin Lamers; van R Horssen; te J Riet; van Fcmjm Delft; Regina Lüttge; X.F. Walboomers; John A. Jansen


European Cells & Materials | 2012

Dynamic Cell Adhesion and Migration on Nanoscale Grooved Substrates

Edwin Lamers; J. te Riet; Maciej Domanski; Regina Lüttge; Carl G. Figdor; Johannes G.E. Gardeniers; X.F. Walboomers; John A. Jansen


Tissue Engineering Part C-methods | 2011

Cryo DualBeam Focused Ion Beam–Scanning Electron Microscopy to Evaluate the Interface Between Cells and Nanopatterned Scaffolds

Edwin Lamers; X. Frank Walboomers; Maciej Domanski; George McKerr; Barry O'Hagan; Clifford Barnes; Lloyd Peto; Regina Lüttge; Louis Winnubst; Han Gardeniers; John A. Jansen


Journal of Materials Science: Materials in Medicine | 2012

Production and characterization of miro- and nano-features in biomedical alumina and zirconia ceramics using a tape casting route

Maciej Domanski; Louis Winnubst; Regina Lüttge; Edwin Lamers; X. Frank Walboomers; John A. Jansen; Han Gardeniers

Collaboration


Dive into the Edwin Lamers's collaboration.

Top Co-Authors

Avatar

John A. Jansen

Radboud University Nijmegen

View shared research outputs
Top Co-Authors

Avatar

Regina Lüttge

Eindhoven University of Technology

View shared research outputs
Top Co-Authors

Avatar

Maciej Domanski

MESA+ Institute for Nanotechnology

View shared research outputs
Top Co-Authors

Avatar

X.F. Walboomers

Radboud University Nijmegen Medical Centre

View shared research outputs
Top Co-Authors

Avatar

L. Prodanov

Radboud University Nijmegen Medical Centre

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Han Gardeniers

MESA+ Institute for Nanotechnology

View shared research outputs
Top Co-Authors

Avatar

J. te Riet

Radboud University Nijmegen

View shared research outputs
Top Co-Authors

Avatar

Louis Winnubst

MESA+ Institute for Nanotechnology

View shared research outputs
Top Co-Authors

Avatar

Johannes G.E. Gardeniers

MESA+ Institute for Nanotechnology

View shared research outputs
Researchain Logo
Decentralizing Knowledge