Neurourology and Urodynamics | 2015

Do different vaginal tapes need different suburethral incisions? The one-half rule

Volker Viereck; Andrzej Kuszka; Oliver Rautenberg; Edyta Wlaźlak; Grzegorz Surkont; Reinhard Hilgers; Jakob Eberhard; Jacek Kociszewski

Despite a wide array of vaginal tapes to treat stress urinary incontinence (SUI), evidence suggesting that both patient characteristics and tape positioning influence outcomes, and differing tape insertion pathways (retropubic vs. transobturator), it remains unclear if the same incision location is effective for all tapes. The aim of the study was to compare outcomes using two different surgical incision locations when inserting a transobturator vaginal tape (TOT) to treat SUI.


Neurourology and Urodynamics | 2017

Role of intrinsic sphincter deficiency with and without urethral hypomobility on the outcome of tape insertion

Edyta Wlaźlak; Volker Viereck; Jacek Kociszewski; Andrzej Kuszka; Oliver Rautenberg; Claudia Walser; Grzegorz Surkont; Marianne Gamper; Mathias K. Fehr

Intrinsic sphincter deficiency (ISD) is a known risk factor for therapy failure after tension‐free vaginal tape (TVT) insertion. The purpose of this study was to investigate if the severity of ISD alone or other factors such as urethral mobility and tape localization influence outcomes.


Ginekologia Polska | 2017

Novel biomarkers of overactive bladder syndrome

Andrzej Wróbel; Tomasz Kluz; Grzegorz Surkont; Edyta Wlaźlak; Paweł Skorupski; Aleksandra Filipczak; Tomasz Rechberger

The social aspect of overactive bladder syndrome (OAB) and the lack of objective diagnostic methods for this syndrome have spurred research into its potential biomarkers which can constitute useful diagnostic tools, while also allowing the evaluation of the intensity of clinical symptoms and the efficacy of implemented pharmacotherapy in OAB patients. Due to the complex etiopathogenesis of this syndrome, the researchers are seeking biomarkers connected with inflammation or nerve growth. The aim of this review was to analyse the latest literature data regarding potential biomarkers in OAB. The most promising opportunities are connected with the diagnostic use of the nerve growth factor (NGF), the brain derived neurotrophic factor (BDNF), C-reactive protein (CRP), prostaglandins and cytokines. Despite the most promising results to date having been obtained with regards to neurotrophic factors, it seems that, at the moment, none of these meets the criteria for becoming an isolated OAB marker. It is also suggested that the combined use of several biomarkers will facilitate obtaining the appropriate level of specificity and selectivity to allow their use in clinical practice.


Journal of Ultrasonography | 2016

Urethral length measurement in women during sonographic urethrocystography – an analysis of repeatability and reproducibility

Edyta Wlaźlak; Jacek Kociszewski; Jacek Suzin; Maria Magdalena Dresler; Grzegorz Surkont

There has been a rise in the use of sonographic urethrocystography in patients with a full bladder. So far, no publications have been made on the analysis of repeatability and reproducibility of the measurements performed during this procedure. Aim An assessment of repeatability and reproducibility of urethral length measurements during sonographic urethrocystography in females with a full bladder in the introital approach, using real-time two-dimensional transvaginal ultrasound. Material and methods The ultrasound was performed in accordance with a standardized technique in female patients with a full bladder containing 200–300 mL of liquid. A total of 92 patients were included in the analysis. Results The Intraclass Correlation Coefficient for repeatability and reproducibility of urethral length measurements in sonographic urethrocystography ranged between 0.9217 and 0.9873 (p = 0.0000). The analysis of ultrasound urethral length measurements taken by two different physicians at an interval of several months confirmed their very high compatibility (ICC = 0.81, p = 0.000). Conclusions Very good repeatability and reproducibility of urethral length findings during sonographic urethrocystography performed in accordance with the presented technique support the possible use of this type of examination in both clinical practice and research.


Neurotoxicity Research | 2018

Blebbistatin, a Myosin II Inhibitor, Exerts Antidepressant-Like Activity and Suppresses Detrusor Overactivity in an Animal Model of Depression Coexisting with Overactive Bladder

Andrzej Wróbel; Urszula Doboszewska; Ewa Rechberger; Małgorzata Bańczerowska-Górska; Piotr Czuczwar; Ewa Poleszak; Jarosław Dudka; Piotr Wlaź; Paweł Miotła; Edyta Wlaźlak; Tomasz Rechberger

Overactive bladder (OAB) coexists with depression in women. Here, we assessed the effects of a 1-week treatment with blebbistatin, a myosin II inhibitor, on changes in behavior and detrusor overactivity (DO) symptoms induced by a 6-week administration of 13-cis-retinoic acid (13-cis-RA), with the aid of the forced swim test (FST), spontaneous locomotor activity test, and in vivo cystometric investigations in female Wistar rats. 13-cis-RA-induced depressive-like behavior and DO symptoms were associated with increased corticotropin-releasing factor (CRF) level in the plasma, prefrontal cortex (PFC), hippocampus (Hp), Barrington’s nucleus (BN), and urinary bladder. Moreover, 13-cis-RA decreased brain-derived neurotrophic factor (BDNF) and nerve growth factor (NGF) levels in plasma, PFC, Hp, and BN, while it increased BDNF and NGF levels in urinary bladder. Blebbistatin exerted antidepressant-like effect and attenuated changes in the cystometric parameters as well as the central and peripheral levels of CRF, BDNF, and NGF that were induced by 13-cis-RA, while it did not affect urine production, mean, systolic or diastolic blood pressure, or heart rate. The results point to blebbistatin as a potential treatment option for OAB coexisting with depression.


Journal of Ultrasonography | 2017

Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe

Maria Magdalena Dresler; Jacek Kociszewski; Edyta Wlaźlak; Piotr Pędraszewski; Agnieszka Trzeciak; Grzegorz Surkont

Introduction Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. Aim of the study The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes.


Ginekologia Polska | 2017

The analysis of repeatability and reproducibility of bladder neck mobility measurements obtained during pelvic floor sonography performed introitally with 2D transvaginal probe

Edyta Wlaźlak; Tomasz Kluz; Jacek Kociszewski; Karolina Frachowicz; Magdalena Janowska; Wiktor Wlaźlak; Grzegorz Surkont

OBJECTIVES The aim of the study was the evaluation of repeatability and reproducibility of chosen urethral neck mobility measurements obtained during introital pelvic floor sonography performed with a 2D transvaginal probe. MATERIAL AND METHODS In order to assess the repeatability and reproducibility, independent measurements on the ultra-sound image were taken by two specialists on 92 female patients at rest and at strain (Valsalva maneuver). 2D ultrasound examination was performed introitally with a transvaginal probe (PFS-TV). The location of the urethral internal orifice was defined with coordinates of two points. Point CI marks the urethral anterior edge visualized on ultrasound as closer to the pubic symphysis. Point CII marks the posterior edge visualized more peripherally from pubic symphysis. RESULTS Repeatability and reproducibility measurements of point CI location and mobility were good and very good (0.6710-0.9961), while of point CII - were medium, good and very good (0.5738-0.9944). Point CI was clearly visible in all cases. It was not possible to accurately mark point CII in 4.3-17.4% of cases. CONCLUSIONS The possibility to visualize point CI in every single case with very good and good repeatability and reproduc-ibility of measurements of this points location and mobility allows the usage of CI point as a universal reference point for evaluation of bladder neck mobility and position during PFS-TV in the clinical practice and for research purposes.


Ginekologia Polska | 2017

The effectiveness of a pre-pubic four-arm NAZCA-TC mesh in treating cystocele and stress urinary incontinence simultaneously — results controlled with a pelvic floor ultrasound. A preliminary study

Edyta Wlaźlak; Tomasz Kluz; Andrzej Wróbel; Magda Krzycka; Grzegorz Surkont

OBJECTIVES It is controversial whether pelvic organ prolapse and stress urinary incontinence (SUI) should be treated simultaneously with a single surgery or separately with two procedures. The pre-pubic four-arm NAZCA-TC® mesh was invented to treat cystocele and SUI with a single procedure. The objective of this study is to analyze short-term results after the implantation of NAZCA-TC mesh. MATERIAL AND METHODS A total of 18 women underwent the evaluation of results of mesh implantation within a 24 to 36 months follow-up. Pre-operatively, patients were examined under standardized conditions. Postoperatively we analyzed the following: standardized interview and examination as well as pelvic floor ultrasound: 2D with a transvaginal probe and 4D with an abdominal probe. RESULTS There was one case of intraoperative bladder damage noticed and repaired followed with NAZCA implantation. In 2 cases vaginal erosion was found that healed successfully after re-operation. In 3 cases hematomas were observed but resolved spontaneously. After the surgery there was a statistically significant improvement of prolapse in anterior (p < 0.0003) and in central (p < 0.001) compartment. Six women (33.3%) had no stress urinary incontinence symptoms during the control visit but we did not find a statistically significant improvement in SUI symptoms after the procedure. We recorded no case of hypomobile urethra after the surgery. The mesh covered > 50% of the urethral length in all of the patients. CONCLUSIONS Mid-term results showed that implantation of NAZCA TC mesh allows to achieve statistically significant im-provement in reducing cystocele coexisting with enterocele in over 65% of patients. A complete cure from stress urinary incontinence was confirmed in 1/3 of patients. NAZCA-TC covered more than 50% of the urethral length, which can possibly have a negative influence on the effectiveness of the suburethral tape.


Ginekologia Polska | 2017

Transvaginal six-arm mesh OPUR in women with apical pelvic organ prolapse — analysis of short-term results, pelvic floor ultrasound evaluation

Tomasz Kluz; Edyta Wlaźlak; Grzegorz Surkont

OBJECTIVES Analysis of feasibility, efficacy and short-term results after six-arm transvaginal mesh OPUR implantation in women with apical prolapse. MATERIAL AND METHODS The same surgeon operated all of 39 women using mesh OPUR. Preoperatively patients had a standardized interview and clinical examination. Intraoperative and postoperative complications were analyzed. Postoperative evaluation included standardized interview, clinical examination and standardized pelvic floor ultrasound performed with 2D transvaginal probe and 4D abdominal probe. RESULTS There was no complication that needed operative intervention. Hematomas in 3 patients resolved spontaneously. Transient voiding difficulties which lasted less than 7 days were observed in 5 patients. No erosion was observed. Comparison of pre- and postoperative results in 34 women revealed that in all 3 compartments improvement in POP-Q scale was statistically significant (p < 0.0000). One patient with malposition and rolled up mesh needed re-operation. During PFS-TV in 94.1% of patients urethra was normobile or hypermobile. In all of the patients urethral end of the mesh was positioned far enough from the middle part of the urethra (ultrasound) to implant suburethral sling without risk of collision. Sexually active women did not inform of any important discomfort or pain during intercourse. CONCLUSIONS It seems that six-arm OPUR mesh, if implanted under strict surgical rules, gives low risk of complications and high chance to successfully reduce POP symptoms in short term after the operation. It seems that OPUR mesh should not have negative influence on the results after anti-incontinence suburethral sling.


Ginekologia Polska | 2017

Adjustable single incision sling Ajust — the effects of first operations controlled by pelvic floor sonography

Tomasz Kluz; Edyta Wlaźlak; Andrzej Wróbel; Wiktor Wlaźlak; Michał Pazdrak; Grzegorz Surkont

OBJECTIVE The aim of this study is to evaluate using PFS-TV the mid-term results of our first operative experience with implanting a single incision sling - Ajust™. MATERIAL AND METHODS One and the same surgeon has operated all the patients with symptoms of stress urinary incontinence. Ajust was the only performed procedure. Postoperative evaluation consisted of: a standardized interview and examination, a cough test and a PFS-TV for evaluation of urinary continence and tape location. PFS-TV was performed under standardized conditions at rest and during maximum Valsalva maneuver. RESULTS This is a retrospective analysis of data from a total of 31 patients who attended a control visit between the 36th and the 50th month following the operation. Sixteen patients (51.6%) were cured. There were statistically significant differences in urethral mobility (p < 0.0007) and tape-urethra distance (p < 0.002) between cured and not-cured group. The difference in urethral length was not statistically significant. 77.8% of women with a hypermobile urethra was cured in contrast to 15.4% with a normobile urethra. Neither of the groups had a hypomobile urethra patient. There were no significant complications intra- or post-operatively. De novo urgency was observed in 1 patient only. CONCLUSIONS Implantation of Ajust tape seems to be a safe mode of operative treatment for SUI in women. Our mid-term results suggest that long term effects might be worse compared to retropubic or transobturator tapes, especially at first operative experience with Ajust. Urethral mobility seems to be an important risk factor for treatment failure after Ajust implantation. It seems that patients that may benefit from Ajust most are women with urethral hypomobility but this needs to be verified with a prospective study.

Collaboration


Dive into the Edyta Wlaźlak's collaboration.

Top Co-Authors

Avatar

Grzegorz Surkont

Medical University of Łódź

View shared research outputs
Top Co-Authors

Avatar

Jacek Suzin

Medical University of Łódź

View shared research outputs
Top Co-Authors

Avatar

Tomasz Stetkiewicz

Memorial Hospital of South Bend

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Andrzej Wróbel

Medical University of Lublin

View shared research outputs
Top Co-Authors

Avatar

Tomasz Rechberger

Medical University of Lublin

View shared research outputs
Top Co-Authors

Avatar

Wiesław Tyliński

Medical University of Łódź

View shared research outputs
Top Co-Authors

Avatar

Anna Sobczuk

Memorial Hospital of South Bend

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Paweł Miotła

Medical University of Lublin

View shared research outputs
Researchain Logo
Decentralizing Knowledge