Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Elena Bergamini is active.

Publication


Featured researches published by Elena Bergamini.


Sensors | 2014

Estimating orientation using magnetic and inertial sensors and different sensor fusion approaches: accuracy assessment in manual and locomotion tasks.

Elena Bergamini; Gabriele Ligorio; Aurora Summa; Giuseppe Vannozzi; Aurelio Cappozzo; Angelo M. Sabatini

Magnetic and inertial measurement units are an emerging technology to obtain 3D orientation of body segments in human movement analysis. In this respect, sensor fusion is used to limit the drift errors resulting from the gyroscope data integration by exploiting accelerometer and magnetic aiding sensors. The present study aims at investigating the effectiveness of sensor fusion methods under different experimental conditions. Manual and locomotion tasks, differing in time duration, measurement volume, presence/absence of static phases, and out-of-plane movements, were performed by six subjects, and recorded by one unit located on the forearm or the lower trunk, respectively. Two sensor fusion methods, representative of the stochastic (Extended Kalman Filter) and complementary (Non-linear observer) filtering, were selected, and their accuracy was assessed in terms of attitude (pitch and roll angles) and heading (yaw angle) errors using stereophotogrammetric data as a reference. The sensor fusion approaches provided significantly more accurate results than gyroscope data integration. Accuracy improved mostly for heading and when the movement exhibited stationary phases, evenly distributed 3D rotations, it occurred in a small volume, and its duration was greater than approximately 20 s. These results were independent from the specific sensor fusion method used. Practice guidelines for improving the outcome accuracy are provided.


Gait & Posture | 2011

Tibio-femoral joint constraints for bone pose estimation during movement using multi-body optimization

Elena Bergamini; H. Pillet; Jérôme Hausselle; Patricia Thoreux; Sandra Guérard; Valentina Camomilla; Aurelie Cappozzo; Wafa Skalli

When using skin markers and stereophotogrammetry for movement analysis, bone pose estimation may be performed using multi-body optimization with the intent of reducing the effect of soft tissue artefacts. When the joint of interest is the knee, improvement of this approach requires defining subject-specific relevant kinematic constraints. The aim of this work was to provide these constraints in the form of plausible values for the distances between origin and insertion of the main ligaments (ligament lengths), during loaded healthy knee flexion, taking into account the indeterminacies associated with landmark identification during anatomical calibration. Ligament attachment sites were identified through virtual palpation on digital bone templates. Attachments sites were estimated for six knee specimens by matching the femur and tibia templates to low-dose stereoradiography images. Movement data were obtained using stereophotogrammetry and pin markers. Relevant ligament lengths for the anterior and posterior cruciate, lateral collateral, and deep and superficial bundles of the medial collateral ligaments (ACL, PCL, LCL, MCLdeep, MCLsup) were calculated. The effect of landmark identification variability was evaluated performing a Monte Carlo simulation on the coordinates of the origin-insertion centroids. The ACL and LCL lengths were found to decrease, and the MCLdeep length to increase significantly during flexion, while variations in PCL and MCLsup length was concealed by the experimental indeterminacy. An analytical model is given that provides subject-specific plausible ligament length variations as functions of the knee flexion angle and that can be incorporated in a multi-body optimization procedure.


Gait & Posture | 2013

Assessing locomotor skills development in childhood using wearable inertial sensor devices: the running paradigm

Ilaria Masci; Giuseppe Vannozzi; Elena Bergamini; Caterina Pesce; Nancy Getchell; Aurelio Cappozzo

Objective quantitative evaluation of motor skill development is of increasing importance to carefully drive physical exercise programs in childhood. Running is a fundamental motor skill humans adopt to accomplish locomotion, which is linked to physical activity levels, although the assessment is traditionally carried out using qualitative evaluation tests. The present study aimed at investigating the feasibility of using inertial sensors to quantify developmental differences in the running pattern of young children. Qualitative and quantitative assessment tools were adopted to identify a skill-sensitive set of biomechanical parameters for running and to further our understanding of the factors that determine progression to skilled running performance. Running performances of 54 children between the ages of 2 and 12 years were submitted to both qualitative and quantitative analysis, the former using sequences of developmental level, the latter estimating temporal and kinematic parameters from inertial sensor measurements. Discriminant analysis with running developmental level as dependent variable allowed to identify a set of temporal and kinematic parameters, within those obtained with the sensor, that best classified children into the qualitative developmental levels (accuracy higher than 67%). Multivariate analysis of variance with the quantitative parameters as dependent variables allowed to identify whether and which specific parameters or parameter subsets were differentially sensitive to specific transitions between contiguous developmental levels. The findings showed that different sets of temporal and kinematic parameters are able to tap all steps of the transitional process in running skill described through qualitative observation and can be prospectively used for applied diagnostic and sport training purposes.


Sensors | 2015

How Angular Velocity Features and Different Gyroscope Noise Types Interact and Determine Orientation Estimation Accuracy.

Ilaria Pasciuto; Gabriele Ligorio; Elena Bergamini; Giuseppe Vannozzi; Angelo M. Sabatini; Aurelio Cappozzo

In human movement analysis, 3D body segment orientation can be obtained through the numerical integration of gyroscope signals. These signals, however, are affected by errors that, for the case of micro-electro-mechanical systems, are mainly due to: constant bias, scale factor, white noise, and bias instability. The aim of this study is to assess how the orientation estimation accuracy is affected by each of these disturbances, and whether it is influenced by the angular velocity magnitude and 3D distribution across the gyroscope axes. Reference angular velocity signals, either constant or representative of human walking, were corrupted with each of the four noise types within a simulation framework. The magnitude of the angular velocity affected the error in the orientation estimation due to each noise type, except for the white noise. Additionally, the error caused by the constant bias was also influenced by the angular velocity 3D distribution. As the orientation error depends not only on the noise itself but also on the signal it is applied to, different sensor placements could enhance or mitigate the error due to each disturbance, and special attention must be paid in providing and interpreting measures of accuracy for orientation estimation algorithms.


Journal of Biomechanics | 2017

Overcoming the limitations of the Harmonic Ratio for the reliable assessment of gait symmetry

Ilaria Pasciuto; Elena Bergamini; Marco Iosa; Giuseppe Vannozzi; Aurelio Cappozzo

The Harmonic Ratio (HR) is an index based on the spectral analysis of lower trunk accelerations that is commonly used to assess the quality of gait. However, it presents several issues concerning reliability and interpretability. As a consequence, the literature provides very different values albeit corresponding to the same populations. In the present work, an improved harmonic ratio (iHR) was defined, relating the power of the intrinsic harmonics (i.e. associated with the symmetric component of gait) to the total power of the signal for each stride, leading to a normalised index ranging from 0 to 100%. The effect of the considered number of harmonics and strides on the estimate of both HR and iHR was assessed. The gait of three groups of volunteers was investigated: young healthy adults, elderly women and male trans-femoral amputees. Both HR and iHR were able to discriminate gait deviations from the gait of young healthy adults. Moreover, iHR proved to be more robust with respect to the number of considered harmonics and strides, and to exhibit a lower inter-stride variability. Additionally, using a normalised index as iHR led to a more straightforward interpretation and improved comparability. The importance of standardised conditions for the index evaluation was unveiled, and, in order to enhance the future comparability of the index, the following guidelines were presented: considering at least 20 harmonics and 20 strides; expressing the acceleration components in a repeatable, anatomical, local system of reference; and evaluating the iHR index, rather than the traditional HR.


Sensors | 2016

Assessing the Performance of Sensor Fusion Methods: Application to Magnetic-Inertial-Based Human Body Tracking.

Gabriele Ligorio; Elena Bergamini; Ilaria Pasciuto; Giuseppe Vannozzi; Aurelio Cappozzo; Angelo M. Sabatini

Information from complementary and redundant sensors are often combined within sensor fusion algorithms to obtain a single accurate observation of the system at hand. However, measurements from each sensor are characterized by uncertainties. When multiple data are fused, it is often unclear how all these uncertainties interact and influence the overall performance of the sensor fusion algorithm. To address this issue, a benchmarking procedure is presented, where simulated and real data are combined in different scenarios in order to quantify how each sensor’s uncertainties influence the accuracy of the final result. The proposed procedure was applied to the estimation of the pelvis orientation using a waist-worn magnetic-inertial measurement unit. Ground-truth data were obtained from a stereophotogrammetric system and used to obtain simulated data. Two Kalman-based sensor fusion algorithms were submitted to the proposed benchmarking procedure. For the considered application, gyroscope uncertainties proved to be the main error source in orientation estimation accuracy for both tested algorithms. Moreover, although different performances were obtained using simulated data, these differences became negligible when real data were considered. The outcome of this evaluation may be useful both to improve the design of new sensor fusion methods and to drive the algorithm tuning process.


PLOS ONE | 2016

Multilevel Upper Body Movement Control during Gait in Children with Cerebral Palsy

Aurora Summa; Giuseppe Vannozzi; Elena Bergamini; Marco Iosa; Daniela Morelli; Aurelio Cappozzo

Upper body movements during walking provide information about balance control and gait stability. Typically developing (TD) children normally present a progressive decrease of accelerations from the pelvis to the head, whereas children with cerebral palsy (CP) exhibit a general increase of upper body accelerations. However, the literature describing how they are transmitted from the pelvis to the head is lacking. This study proposes a multilevel motion sensor approach to characterize upper body accelerations and how they propagate from pelvis to head in children with CP, comparing with their TD peers. Two age- and gender-matched groups of 20 children performed a 10m walking test at self-selected speed while wearing three magneto-inertial sensors located at pelvis, sternum, and head levels. The root mean square value of the accelerations at each level was computed in a local anatomical frame and its variation from lower to upper levels was described using attenuation coefficients. Between-group differences were assessed performing an ANCOVA, while the mutual dependence between acceleration components and the relationship between biomechanical parameters and typical clinical scores were investigated using Regression Analysis and Spearman’s Correlation, respectively (α = 0.05). New insights were obtained on how the CP group managed the transmission of accelerations through the upper body. Despite a significant reduction of the acceleration from pelvis to sternum, children with CP do not compensate for large accelerations, which are greater than in TD children. Furthermore, those with CP showed negative sternum-to-head attenuations, in agreement with the documented rigidity of the head-trunk system observed in this population. In addition, the estimated parameters proved to correlate with the scores used in daily clinical practice. The proposed multilevel approach was fruitful in highlighting CP-TD gait differences, supported the in-field quantitative gait assessment in children with CP and might prove beneficial to designing innovative intervention protocols based on pelvis stabilization.


BioMed Research International | 2015

Wheelchair Propulsion Biomechanics in Junior Basketball Players: A Method for the Evaluation of the Efficacy of a Specific Training Program

Elena Bergamini; Francesca Morelli; Flavia Marchetti; Giuseppe Vannozzi; Lorenzo Polidori; Francesco Paradisi; Marco Traballesi; Aurelio Cappozzo; Anna Sofia Delussu

As participation in wheelchair sports increases, the need of quantitative assessment of biomechanical performance indicators and of sports- and population-specific training protocols has become central. The present study focuses on junior wheelchair basketball and aims at (i) proposing a method to identify biomechanical performance indicators of wheelchair propulsion using an instrumented in-field test and (ii) developing a training program specific for the considered population and assessing its efficacy using the proposed method. Twelve athletes (10 M, 2 F, age = 17.1 ± 2.7 years, years of practice = 4.5 ± 1.8) equipped with wheelchair- and wrist-mounted inertial sensors performed a 20-metre sprint test. Biomechanical parameters related to propulsion timing, progression force, and coordination were estimated from the measured accelerations and used in a regression model where the time to complete the test was set as dependent variable. Force- and coordination-related parameters accounted for 80% of the dependent variable variance. Based on these results, a training program was designed and administered for three months to six of the athletes (the others acting as control group). The biomechanical indicators proved to be effective in providing additional information about the wheelchair propulsion technique with respect to the final test outcome and demonstrated the efficacy of the developed program.


Sensors | 2018

Trends Supporting the In-Field Use of Wearable Inertial Sensors for Sport Performance Evaluation: A Systematic Review

Valentina Camomilla; Elena Bergamini; Silvia Fantozzi; Giuseppe Vannozzi

Recent technological developments have led to the production of inexpensive, non-invasive, miniature magneto-inertial sensors, ideal for obtaining sport performance measures during training or competition. This systematic review evaluates current evidence and the future potential of their use in sport performance evaluation. Articles published in English (April 2017) were searched in Web-of-Science, Scopus, Pubmed, and Sport-Discus databases. A keyword search of titles, abstracts and keywords which included studies using accelerometers, gyroscopes and/or magnetometers to analyse sport motor-tasks performed by athletes (excluding risk of injury, physical activity, and energy expenditure) resulted in 2040 papers. Papers and reference list screening led to the selection of 286 studies and 23 reviews. Information on sport, motor-tasks, participants, device characteristics, sensor position and fixing, experimental setting and performance indicators was extracted. The selected papers dealt with motor capacity assessment (51 papers), technique analysis (163), activity classification (19), and physical demands assessment (61). Focus was placed mainly on elite and sub-elite athletes (59%) performing their sport in-field during training (62%) and competition (7%). Measuring movement outdoors created opportunities in winter sports (8%), water sports (16%), team sports (25%), and other outdoor activities (27%). Indications on the reliability of sensor-based performance indicators are provided, together with critical considerations and future trends.


Knee | 2016

A new method for the evaluation of the end-to-end distance of the knee ligaments and popliteal complex during passive knee flexion

G. Rochcongar; H. Pillet; Elena Bergamini; S. Moreau; Patricia Thoreux; Wafa Skalli; Philippe Rouch

BACKGROUND Accurate knowledge about the length variation of the knee ligaments (ACL, PCL, MCL and LCL) and the popliteal complex during knee flexion/extension is essential for modelling and clinical applications. The aim of the present study is to provide this information by using an original technique able to faithfully reproduce the continuous passive knee flexion-extension kinematics and to reliably identify each ligament/tendon attachment site. METHODS Twelve lower limbs (femur, tibia, fibula, patella) were tested and set in motion (0-120°) using an ad hoc rig. Tibio-femoral kinematics was obtained using an optoelectronic system. A 3D digital model of each bone was obtained using low-dosage stereoradiography. Knee specimens were dissected and the insertion of each ligament and popliteal complex were marked with radio opaque paint. ACL, PCL and MCL were separated into two bundles. Bone epiphyses were CT-scanned to obtain a digital model of each ligament insertion. Bones and attachment site models were registered and the end-to-end distance variation of each ligament/tendon was computed over knee flexion. RESULTS A tibial internal rotation of 18°±4° with respect to the femur was observed. The different bundles of the ACL, MCL and LCL shortened, whereas all bundles of the PCL lengthened. The popliteal complex was found to shorten until 30° of knee flexion and then to lengthen. CONCLUSION The end-to-end distance variation of the knee ligaments and popliteal complex can be estimated during knee flexion using a robust and reliable method based on marking the ligaments/tendon insertions with radiopaque paint. LEVEL OF EVIDENCE Level IV.

Collaboration


Dive into the Elena Bergamini's collaboration.

Top Co-Authors

Avatar

Giuseppe Vannozzi

Sapienza University of Rome

View shared research outputs
Top Co-Authors

Avatar

Aurelio Cappozzo

Sapienza University of Rome

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Angelo M. Sabatini

Sant'Anna School of Advanced Studies

View shared research outputs
Top Co-Authors

Avatar

Gabriele Ligorio

Sant'Anna School of Advanced Studies

View shared research outputs
Top Co-Authors

Avatar

Valeria Belluscio

Sapienza University of Rome

View shared research outputs
Top Co-Authors

Avatar

Patricia Thoreux

Arts et Métiers ParisTech

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

H. Pillet

Arts et Métiers ParisTech

View shared research outputs
Researchain Logo
Decentralizing Knowledge