Elia Marin
Kyoto Institute of Technology
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Elia Marin.
Journal of The Mechanical Behavior of Biomedical Materials | 2016
Marco Boffelli; A. Doimo; Elia Marin; Leonardo Puppulin; Wenliang Zhu; Nobuhiko Sugano; I.C. Clarke; Giuseppe Pezzotti
Two short-term (two and nine months) retrieved zirconia-toughened alumina (ZTA) femoral heads and nine pristine femoral heads from the same manufacturer have been investigated with respect to their surface stability by means of confocal Raman spectroscopy. Quantitative estimations of monoclinic volume fraction have been carried out in both non-wear and main wear zones of the retrieved heads, which invariantly showed high volume fractions of monoclinic polymorph. In-depth (sub-surface) profiles, non-destructively collected in the main wear zones with the Raman probe in confocal configuration, indeed confirmed that polymorphic transformation was extended down to 100μm below the bearing surface of the femoral heads. Acceleration of tetragonal-to-monoclinic transformation rate leads to unexpectedly high fractions of monoclinic phase within very short-term in-vivo exposures. Phase transformation in-vivo is much more marked than what one could actually predict according to simply simulating a hydrothermal environment in-vitro and could not be simply ascribed to the mechanical stress fields generated during normal service at the bearing surface. Instead, the chemical consequences of metal contamination on the ZTA femoral head surface are shown to play the most detrimental role in phase destabilization.
Scientific Reports | 2017
Giuseppe Pezzotti; Elia Marin; Tetsuya Adachi; Alfredo Rondinella; Francesco Boschetto; Wenliang Zhu; Nobuhiko Sugano; Ryan M. Bock; Bryan J. McEntire; Sonny Bal
While the reciprocity between bioceramics and living cells is complex, it is principally governed by the implant’s surface chemistry. Consequently, a deeper understanding of the chemical interactions of bioceramics with living tissue could ultimately lead to new therapeutic strategies. However, the physical and chemical principles that govern these interactions remain unclear. The intricacies of this biological synergy are explored within this paper by examining the peculiar surface chemistry of a relatively new bioceramic, silicon nitride (Si3N4). Building upon prior research, this paper aims at obtaining new insights into the biological interactions between Si3N4 and living cells, as a consequence of the off-stoichiometric chemical nature of its surface at the nanometer scale. We show here yet unveiled details of surface chemistry and, based on these new data, formulate a model on how, ultimately, Si3N4 influences cellular signal transduction functions and differentiation mechanisms. In other words, we interpret its reciprocity with living cells in chemical terms. These new findings suggest that Si3N4 might provide unique new medicinal therapies and effective remedies for various bone or joint maladies and diseases.
Acta Biomaterialia | 2017
Giuseppe Pezzotti; Naoki Oba; Wenliang Zhu; Elia Marin; Alfredo Rondinella; Francesco Boschetto; Bryan J. McEntire; Kengo Yamamoto; B. Sonny Bal
Silicon nitride (Si3N4) ceramics possesses surface chemistry that accelerates bone repair, as previously established by in vitro experiments using both osteosarcoma and mesenchymal cells. The release of silicic acid and nitrogen compounds from the surface Si3N4 enhanced in vitro cellular activity. The results of this study demonstrate for the first time that the osseointegration behavior previously observed is operative with a peculiar chemistry within the human milieu. Si and N elements stimulated progenitor cell differentiation and osteoblastic activity, which ultimately resulted in accelerated bone ingrowth. At the molecular scale, insight into the effect of silicon and nitrogen ions released from the Si3N4 surface was obtained through combined histomorphometric analyses, Raman, Fourier-transform-infrared, and X-ray photoelectron spectroscopies. Identical analyses conducted on a polyetheretherketone (PEEK) spinal explant showed no chemical changes and a lower propensity for osteogenic activity. Silicon and nitrogen are key elements in stimulating cells to generate bony apatite with crystallographic imperfections, leading to enhanced bioactivity of Si3N4 biomedical devices. STATEMENT OF SIGNIFICANCE This research studies osseointegration processes comparing results from explanted PEEK and Si3N4 spinal spacers. Data show that the formation of hydroxyapatite on silicon nitride bio-ceramic surfaces happens with a peculiar mechanism inside the human body. Silicon and nitrogen were incorporated inside the bony tissue structure allowing the developing of off-stoichiometric bony apatite and stimulating progenitor cell differentiation/osteoblastic activity. Silicon and nitrogen ions released from the Si3N4 surface were detected through combined histologic analyses, Raman microspectroscopy, Fourier-transform-infrared, and X-ray photoelectron spectroscopies.
Journal of The Mechanical Behavior of Biomedical Materials | 2017
Giuseppe Pezzotti; Alfredo Rondinella; Elia Marin; Wenliang Zhu; Nicolò Nicoli Aldini; Gianfranco Ulian; Giovanni Valdrè
This study employed highly spectrally resolved Raman spectroscopy to examine the molecular composition of cortical bone tissue obtained from murine females in their healthy and ovariectomy- (OVX-) induced osteoporotic states. The aim of the study was to identify structural differences at the molecular scale both in apatite mineral and collagen fibrils between the two groups of samples. Raman spectroscopy was used to determine the chemical composition of cortical bone in regions including characteristic bands of both bone mineral and bone matrix. The results demonstrated that the mineral apatite of bone did not undergo significant amorphization in its diseased state, with the Raman microprobe also failing in recognizing a direct role of carbonate content in the embrittlement of OVX-diseased bone. On the other hand, complex off-stoichiometry variations could be detected in the columnar Ca-structure of the bony hydroxyapatite according to morphological variations of the Raman band belonging to the symmetric phosphate stretching (A1) band at ~959cm-1. A fundamental role was also recognized for collagen quality on the process of bone embrittlement. The so-called matrix maturity ratio, as systematically measured on Raman spectra in the Amide I region, increased with statistical significance in OVX-treated samples as compared to control samples. An 8% increase could be associated to a 115% increase in elastic stress intensification in the mineral phase of OVX-diseased tissue as compared to the control one, thus proving a degradation in the (elastic) energy-dissipative capacity of a diseased bone matrix.
Journal of The Mechanical Behavior of Biomedical Materials | 2016
Bryan J. McEntire; Yuto Enomoto; Wenliang Zhu; Marco Boffelli; Elia Marin; Giuseppe Pezzotti
Raman microprobe-assisted indentation, a micromechanics method validated in a companion paper, was used to compare the surface toughening behaviors of silicon nitride (Si3N4) and alumina-based bioceramics employed in joint arthroplasty (i.e., monolithic alumina, Al2O3, and yttria-stabilized zirconia (ZrO2)-toughened alumina, ZTA). Quantitative assessments of microscopic stress fields both ahead and behind the tip of Vickers indentation cracks propagated under increasing indentation loads were systematically made using a Raman microprobe with spatial resolution on the order of a single micrometer. Concurrently, crack opening displacement (COD) profiles were monitored on the same microcracks screened by Raman spectroscopy. The Raman eye clearly visualized different mechanisms operative in toughening Si3N4 and ZTA bioceramics (i.e., crack-face bridging and ZrO2 polymorphic transformation, respectively) as compared to the brittle behavior of monolithic Al2O3. Moreover, emphasis was placed on assessing not only the effectiveness but also the durability of such toughening effects when the biomaterials were aged in a hydrothermal environment. A significant degree of embrittlement at the biomaterial surface was recorded in the transformation-toughened ZTA, with the surface toughness reduced by exposure to the hydrothermal environment. Conversely, the Si3N4 biomaterial experienced a surface toughness value independent of hydrothermal attack. Crack-face bridging thus appears to be a durable surface toughening mechanism for biomaterials in joint arthroplasty.
Journal of The Mechanical Behavior of Biomedical Materials | 2016
Giuseppe Pezzotti; Yuto Enomoto; Wenliang Zhu; Marco Boffelli; Elia Marin; Bryan J. McEntire
Indentation micro-fracture is revisited as a tool for evaluating the surface toughness of silicon nitride (Si3N4) bioceramics for artificial joint applications. Despite being unique and practical from an experimental perspective, a quantitative assessment of surface fracture toughness using this method is challenging. An improved method has been developed, consisting of coupling indentation with confocal (spatially resolved) Raman piezo-spectroscopy. Empowered by the Raman microprobe, the indentation micro-fracture method was found to be capable of providing reliable surface toughness measurements in silicon nitride biomaterials. In designing the microstructures of bioceramic bearing couples for improved tribological performance, surface toughness must be considered as a fundamentally different and distinct parameter from bulk toughness. The coupling of indention crack opening displacements (COD) with local stress field assessments by spectroscopy paves the way to reliably compare the structural properties of bioceramics and to quantitatively monitor their evolution during environmental exposure.
Journal of The Mechanical Behavior of Biomedical Materials | 2017
Elia Marin; Alfredo Rondinella; Wenliang Zhu; Bryan J. McEntire; B. Sonny Bal; Giuseppe Pezzotti
The effect of frictional sliding on the surface degradation of commercially available zirconia-toughened alumina (ZTA) femoral heads was studied using a pin-on-ball wear tester under three different lubricating conditions: dry, water, and squalene. Water and squalene were employed under boundary lubrication regimes. Despite the unique (non-standard) character of this apparatus, standard loading conditions could be applied, which effectively determined dynamic friction coefficients as basic material properties. Two types of surface degradation were observed: (i) the polymorphic tetragonal-to-monoclinic (t→m) transformation of the zirconia (ZrO2) dispersoids, and (ii) the off-stoichiometry drift caused by oxygen vacancy formation within the alumina matrix. Scanning laser microscopy (SLM), Raman spectroscopy (RS), scanning electron microscopy (SEM), cathodoluminescence (CL), and X-ray photoelectron spectroscopy (XPS) were utilized to evaluate the fractions of transformed zirconia phase and the stoichiometric evolution of the oxygen sub-lattice at the surface of wear-tested ZTA components. Wear tracks on the surface of the femoral heads were only detected under dry conditions. Dry wear also showed the highest frictional forces and the most pronounced formation of oxygen vacancies among the tested conditions. Conversely, equivalent or greater amounts of the t→m transformation were observed with water and squalene lubrication when compared to the dry wear condition.
Journal of Biomedical Materials Research Part B | 2018
Ryan M. Bock; Elia Marin; Alfredo Rondinella; Francesco Boschetto; Tetsuya Adachi; Bryan J. McEntire; B. Sonny Bal; Giuseppe Pezzotti
The application of bioactive coatings onto orthopaedic appliances is commonly performed to compensate for the otherwise bioinert nature of medical devices and to improve their osseointegration. Calcium phosphates, hydroxyapatite (HAp), and bioglasses are commercially available for this purpose. Until recently, few other inorganic compounds have been identified with similar biofunctionality. However, silicon nitride (Si3 N4 ) has emerged as a new orthopaedic material whose unique surface chemistry also enhances osteoconductivity. Recent research has confirmed that its minority intergranular phase, consisting of silicon yttrium aluminum oxynitride (SiYAlON), is principally responsible for this improvement. As a result, it was hypothesized that SiYAlON itself might serve as an effective osteoconductive coating or glaze for medical devices. To test this hypothesis, a process inspired by traditional ceramic whiteware glazing was developed. A slurry containing ingredients similar to the intergranular SiYAlON composition was applied to a Si3 N4 surface, which was then subjected to a heat treatment to form a glaze. Various analytical tools were employed to assess its chemistry and morphology. It was found that the glaze was comprised predominately of Y5 Si3 O12 N, a compound commonly referred to as N-apatite, which is isostructural to native HAp. Subsequent exposure of the glazed surface to acellular simulated body fluid led to increased deposition of biomimetic HAp-like crystals, while exposure to Saos-2 osteosarcoma cells in vitro resulted in greater HAp deposition relative to control samples. The observation that SiYAlON exhibits enhanced osteoconductivity portends its potential as a therapeutic aid in bone and tissue repair.
Materials | 2017
Giuseppe Pezzotti; Saverio Affatato; Alfredo Rondinella; Makiko Yorifuji; Elia Marin; Wenliang Zhu; Bryan J. McEntire; B. Sonny Bal; Kengo Yamamoto
A clear discrepancy between predicted in vitro and actual in vivo surface phase stability of BIOLOX®delta zirconia-toughened alumina (ZTA) femoral heads has been demonstrated by several independent research groups. Data from retrievals challenge the validity of the standard method currently utilized in evaluating surface stability and raise a series of important questions: (1) Why do in vitro hydrothermal aging treatments conspicuously fail to model actual results from the in vivo environment? (2) What is the preponderant microscopic phenomenon triggering the accelerated transformation in vivo? (3) Ultimately, what revisions of the current in vitro standard are needed in order to obtain consistent predictions of ZTA transformation kinetics in vivo? Reported in this paper is a new in toto method for visualizing the surface stability of femoral heads. It is based on CAD-assisted Raman spectroscopy to quantitatively assess the phase transformation observed in ZTA retrievals. Using a series of independent analytical probes, an evaluation of the microscopic mechanisms responsible for the polymorphic transformation is also provided. An outline is given of the possible ways in which the current hydrothermal simulation standard for artificial joints can be improved in an attempt to reduce the gap between in vitro simulation and reality.
Journal of The Mechanical Behavior of Biomedical Materials | 2018
Giuseppe Pezzotti; Wenliang Zhu; Nobuhiko Sugano; Elia Marin; Kengo Yamamoto; Naomichi Nishiike; Tsubasa Hori; Alfredo Rondinella; Bryan J. McEntire; Ryan M. Bock; B. Sonny Bal
Experimental evidence demonstrates that a loss of stoichiometry at the surface of oxide bioceramic femoral heads enhances the oxidation rate of polyethylene acetabular liners in artificial hip joints. Contradicting the common notion that ceramics are bioinert, three independent experiments confirmed substantial chemical interactions between the ceramic femoral heads and their polyethylene counterparts. The experiments reported herein included hydrothermal tests, frictional tests, and hip-simulator experiments. It was discovered that oxide and non-oxide femoral heads differently affected the oxidation processes at the surface of the polyethylene liners, all other testing parameters being equal. Analytical data from X-ray photoelectron (XPS), cathodoluminescence (CL), Fourier-transform infrared (FTIR), and Raman spectroscopies unequivocally and consistently showed that the oxidation rate of polyethylene liners was greater when coupled with oxide as opposed to non-oxide ceramic heads. XPS analyses of O-Al-O bond fractions at the surface of a zirconia-toughened alumina (ZTA) short-term (20 months in vivo) femoral heads retrieval showed a ~50% reduction in favor of oxygen vacancy O-Al-VO and hydroxylated Al-O-H bonds. Off-stoichiometry drifts were confirmed in vitro under both static and dynamic conditions. They triggered oxidation and tangibly affected an advanced highly cross-linked sequentially irradiated and annealed ultra-high molecular weight polyethylene (UHMWPE) liner (increase in oxidation index up to ΔOI~1.2 after 5 × 105 cycles under dynamic swing conditions). Second-generation UHMWPE liners infused with vitamin E were also affected by the free flow of oxygen from the oxide femoral heads, although to a lesser extent. The fundamental findings of this study, which were also confirmed on retrievals, call for revised standards in material design and testing. Adopting these new criteria will provide an improved understanding of the importance of off-stoichiometry at the head/liner interface and may lead to significant extensions in artificial joint lifetimes.