Eliézer Quadro Oreste
Universidade Federal de Pelotas
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Eliézer Quadro Oreste.
Journal of Analytical Atomic Spectrometry | 2012
Caroline Santos da Silva; Eliézer Quadro Oreste; Adriane Medeiros Nunes; Mariana Antunes Vieira; Anderson Schwingel Ribeiro
A new procedure based on exposure of ethanol biofuel samples to UV radiation in the presence of low molecular weight organic acids was developed for the determination of total Hg (inorganic and organometallic species: Hg2+, CH3Hg+ and CH3CH2Hg+) by photochemical vapor generation coupled with atomic absorption spectrometry (photo-CV-AAS). For each species, the optimum conditions for photochemical generation were investigated, including the effects of medium composition, exposure time to the UV radiation and transfer gas flow rate. The accuracy was evaluated by assessing the recoveries of species-specific spikes (91–107%) as well as by assessing recovery from a mixture of all species of the mercury added to the ethanol biofuel samples based on calibration standards prepared in high purity bidistilled ethanol. The limits of detection ranged from 0.05 to 0.09 μg L−1 for all addition and recovery tests, enabling the determination of total Hg. The proposed method is sensitive, simple (no sample pretreatment) and provides a direct approach to the generation of mercury vapor from ethanol biofuel samples while promoting “green” chemistry.
Analytical Methods | 2013
Eliézer Quadro Oreste; Richard Macedo de Oliveira; Adriane Medeiros Nunes; Mariana Antunes Vieira; Anderson Schwingel Ribeiro
The aim of this study was to present three sample preparation methods for the determination of Cd, Pb and Sn in meat by Graphite Furnace Atomic Absorption Spectrometry (GFAAS): acid digestion, solubilization with tetramethylammonium hydroxide and formic acid. For the digestion with HNO3, a conventional open system with a cold finger was used. This system helped to avoid losses of analytes and reagents by volatilization, permitting to operate at high temperatures applied at a digester block and reducing the digestion time (∼1 h). Solubilizations were performed at room temperature. The slurry was left standing overnight and remained closed until achieving complete solubilization. The temperature program of the graphite furnace was optimized for each element in the different means of preparation samples using a mixture of Pd–Mg. The figures of merit were similar for all sample preparation methods evaluated. The limits of detection obtained for the acid digestion procedure were 0.0006, 0.0164 and 0.0520 μg g−1 for Cd, Pb and Sn, respectively. In order to evaluate the accuracy of the results obtained by the three sample preparation methods, recovery tests for four real meat samples were performed and the recoveries ranged from 93.7 to 109%, supporting the accuracy of the method. Also, different certified reference materials of meat were analyzed and the results obtained were in agreement with the certified value at 95% of confidence (t-test). The best results were obtained by the acid digestion procedure with the cold finger system. This procedure is faster, the system is semi-closed with no significant contamination or loss of analytes by volatilization and it provides a better signal/noise ratio.
Journal of the Brazilian Chemical Society | 2013
Meibel T. Lisboa; Caroline Dutra Clasen; Daiane C. de Sousa Vellar; Eliézer Quadro Oreste; Tatiana D. Saint'Pierre; Anderson Schwingel Ribeiro; Mariana Antunes Vieira
It is presented an alternative procedure for preparation of biodiesel samples for elemental determination by inductively coupled plasma optical emission spectrometry (ICP OES), based on the sample (10% m/v) emulsion formation with formic acid (15% v/v) and Triton X-100 (0.1% m/v). These concentrations were optimized and the stability of emulsified aqueous standards and samples was found to be of at least 3 h. Experimental conditions (1500 W of RF power and 0.5 L min-1 of Ar nebulizer flow rate) were optimized from those recommended by the equipment manufacturer, with a solution containing 10 mg L-1 of each analyte prepared with mineral oil in the same conditions of the emulsion. Matrix effects were investigated by observing the slopes of analyte addition curves for different biodiesel samples. Results showed that external calibration with inorganic aqueous standard solutions in the emulsion medium should be used. Limits of detection obtained (in mg kg-1) were 0.121, 0.008, 0.006, 0.001, 0.006, 0.071, 0.241 and 0.024 for Ca, Cu, Fe, Mn, Mg, Na, K and Si, respectively. The accuracy of the procedure for Ca, Mg, K and Na was assessed by the analysis of a multi-element standards B100 biodiesel (Conostan) and the recoveries ranged from 91 to 107%. The proposed procedure used low toxicity reagents and showed to be a simple and straightforward alternative of sample preparation for metal determination in biodiesel by ICP OES with limits of detection adequate for those analyses.
Journal of the Brazilian Chemical Society | 2012
Caroline Santos da Silva; Adriane Medeiros Nunes; Eliézer Quadro Oreste; Tanize S. Acunha; Mariana Antunes Vieira; Anderson Schwingel Ribeiro
Foram avaliados dois metodos diferentes de preparo de amostras de carnes baseados na solubilizacao em meios alcalino ou acido. O objetivo deste estudo foi determinar os teores de Na e K apos solubilizacao com hidroxido de tetrametilamonio (TMAH) temperatura ambiente, e com acido formico e aquecimento em bloco de digestao a 50 oC por cerca de 2 h. A solubilizacao alcalina se apresentou como uma metodologia simples e robusta e a melhor alternativa frente aos procedimentos de mineralizacao convencional, permitindo a solubilizacao completa das amostras usando pequenas quantidades de TMAH. O metodo foi validado empregando-se materiais de referencia certificada assim como pela comparacao com metodo de digestao convencional com acido nitrico. Os limites de deteccao obtidos foram de 0,8 e 2,0 mg g-1 para Na e K, respectivamente, e se mostraram adequados para o objetivo das analises.
Journal of the Brazilian Chemical Society | 2011
Adriane Medeiros Nunes; Tanize S. Acunha; Eliézer Quadro Oreste; Fábio Grandis Lepri; Mariana Antunes Vieira; Adilson José Curtius; Anderson Schwingel Ribeiro
Um metodo simples para o tratamento de amostras de carne fresca e processada com hidroxido de tetrametilamonio (TMAH) e proposto para a determinacao de Ca, Fe e Mg por espectrometria de absorcao atomica com chama (FAAS) e Cu por espectrometria de absorcao atomica com forno de grafite (GFAAS). A exatidao foi avaliada por comparacao dos resultados usando outros dois procedimentos de preparo de amostra e por analise de materiais de referencia certificados. Nao houve diferenca significativa entre os resultados obtidos, em um nivel de confianca de 95%. Os limites de deteccao para Ca, Cu, Fe e Mg foram 45,0, 0,2, 16,0 e 0,3 µg g -1 , respectivamente. A espectrometria de absorcao atomica de alta resolucao com fonte continua em forno de grafite (HR-CS GFAAS) foi empregada para avaliar as interferencias espectrais na determinacao de Cu. Entretanto, nenhuma interferencia foi encontrada. O metodo proposto e simples, rapido e confiavel para analise de produtos carneos e nao requer o uso de equipamentos especiais nem de acidos fortes no preparo das amostras. A simple method for treating fresh and processed meat with tetramethylammonium hydroxide (TMAH) is proposed for the determination of Ca, Fe and Mg by flame atomic absorption spectrometry (FAAS) and Cu by graphite furnace atomic absorption spectrometry (GFAAS). The accuracy was evaluated by comparison of the results by using two other sample preparation procedures and by the analysis of certified reference materials. No significant differences between the results were found at the 95% confidence level. Limits of detection for Ca, Cu, Fe and Mg were 45.0, 0.2, 16.0 and 0.3 µg g -1 , respectively. High-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS) was employed to evaluate the spectral interference in the determination of Cu. However, no interference was found. The proposed method is simple, fast and reliable for meat products analysis and does not require especial equipment, neither strong acid for sample preparation.
Food Chemistry | 2018
Ana Paula Mörschbächer; Anja Dullius; Carlos Henrique Dullius; Cassiano Ricardo Bandt; Daniel Kuhn; Débora Tairini Brietzke; Fernando José Malmann Kuffel; Henrique Pretto Etgeton; Taciélen Altmayer; Tamara Engelmann Gonçalves; Eliézer Quadro Oreste; Anderson Schwingel Ribeiro; Claucia Fernanda Volken de Souza; Lucélia Hoehne
The present paper describes the validation of a spectrophotometry method involving molecular absorption in the visible ultraviolet-visible (UV-Vis) region for selenium (Se) determination in the bacterial biomass produced by lactic acid bacteria (LAB). The method was found to be suitable for the target application and presented a linearity range from 0.025 to 0.250 mg/L Se. The angular and linear coefficients of the linear equation were 1.0678 and 0.0197 mg/L Se, respectively, and the linear correlation coefficient (R2) was 0.9991. Analyte recovery exceeded 96% with a relative standard deviation (RSD) below 3%. The Se contents in LAB ranged from 0.01 to 20 mg/g. The Se contents in the bacterial biomass determined by UV-Vis were not significantly different (p > 0.05) those determined by graphite furnace atomic absorption spectrometry. Thus, Se can be quantified in LAB biomass using this relatively simpler technique.
Journal of the Brazilian Chemical Society | 2015
Michele B. da Rosa; Eliézer Quadro Oreste; Daísa H. Bönemann; Amanda Ávila Rodrigues; Claire Tondo Vendruscolo; Angelita da Silveira Moreira; Anderson Schwingel Ribeiro; Adriane Medeiros Nunes
The aim of this study was to evaluate the performance of a reflux system adapted in the digestion tubes in sample preparation of xanthan gum for subsequent determination of Ca, Cu, K, Mg, Na and Zn by using spectrometric techniques. Through the proposed method, the samples were digested with HNO3 for 3 h in a digester block at 220 °C. The accuracy of the method was evaluated by comparing the results with another sample preparation method and by using recovery tests, which results vary between 83 and 103%. The efficiency of digestion was assessed and significant results were verified through residual carbon values, which were five times lower compared to conventional acid digestion in open system, with use of HNO3 and HClO4. The proposed methodology is a simple and accurate analytical strategy, which does not require the use of special equipment, neither a mixture of strong oxidizing acid in the sample preparation.
Journal of the Brazilian Chemical Society | 2015
Camila Corrêa Pereira; Alexander Ossanes de Souza; Eliézer Quadro Oreste; Mirla Cidade; Solange Cadore; Anderson Schwingel Ribeiro; Mariana Antunes Vieira
In the first part of this paper, two acid decomposition procedures for the determination of Al, Ca, Fe, Mg, Mn and Zn contents in yerba mate samples by inductively coupled plasma optical emission spectrometry (ICP OES) were compared. Using a reflux system, the samples were treated with a mixture of HNO3 and H2O2 for 3 hours at 220 °C in the digester block. The results from five commercial yerba mate samples were compared with the results obtained from microwave digestion. Good agreement between the procedures at a 95% confidence level was obtained with relative standard deviation (RSD) values lower than 10.0%. The accuracy was evaluated using addition and recovery experiments (80.5 to 112.8%). In the second part, Ca, Cd, Cr, Cu, Fe, K, Mg, Na, Pb and Zn concentrations were evaluated in the yerba mate infusion. The results showed that elements such as Na, K, Mg and Zn are easily transferred to the hot water used for the infusion. For Pb and Cd, the concentrations found in the analyzed samples were lower than the values established by Brazilian legislation.
Food Chemistry | 2018
Camila Corrêa Pereira; Alexander Ossanes de Souza; Eliézer Quadro Oreste; Mariana Antunes Vieira; Anderson Schwingel Ribeiro
The acid decomposition method was applied for the sample preparation of processed fruit juice. The decomposition of 15mL of juice sample using HNO3 and H2O2 was performed in a digester block with reflux system and heated at 200°C for 150min. The limits of detection were 0.03; 0.24; 0.8; 0.008; 0.026 and 0.056mgL-1 for Cr, Cu, K, Mg, Na and Zn, respectively and for Pb was 0.99μgL-1. The accuracy was evaluated by spiked experiments (80 to 119%). Four processed fruit juice samples commercialized in Brazil (strawberry, mango, peach, and orange) were analyzed and indicated the absence of Cr, Zn and Cu in the samples, except for Cu in strawberry juice. Pb was found in the mango juice sample (17.8±0.9μgL-1) and the concentration is below the maximum values recommended by Brazilian legislation for juices of citric fruits (0.3mgkg-1).
Química Nova | 2014
Alexander Ossanes de Souza; Camila Corrêa Pereira; Bruna M. Jado; Eliézer Quadro Oreste; Mariana Antunes Vieira; Anderson Schwingel Ribeiro; Claire Tondo Vendruscolo; Adriane Medeiros Nunes
This paper describes the evaluation of a method for determination of Cd and Pb in xanthan gum samples by Graphite Furnace Atomic Absorption Spectrometry (GF AAS) using NH4H2PO4 as the chemical modifier. The sample preparation was performed using a reflux system adapted in the digestion tubes. With this system it was possible to increase the temperature of the digester block above the boiling point of the reaction medium, preventing loss of analyte and excessive evaporation of acids during heating. Samples were digested with HNO3 for 3 h in a digester block at 220 oC. The limits of detection for Cd and Pb were 2.2 and 33.8 ng g-1, respectively. The RSDs for both analytes were, on average, lower than 5.0% and accuracy was verified by recovery tests, yielding values in the 83-100% range.