Featured researches published by Elwood Armour.


International Journal of Radiation Oncology Biology Physics | 2008

High-Resolution, Small Animal Radiation Research Platform With X-Ray Tomographic Guidance Capabilities

John Wong; Elwood Armour; Peter Kazanzides; Iulian Iordachita; Erik Tryggestad; Hua Deng; Mohammad Matinfar; Christopher W. Kennedy; Zejian Liu; Timothy A. Chan; Owen Gray; Frank Verhaegen; T.R. McNutt; Eric Ford; Theodore L. DeWeese

PURPOSE To demonstrate the computed tomography, conformal irradiation, and treatment planning capabilities of a small animal radiation research platform (SARRP). METHODS AND MATERIALS The SARRP uses a dual-focal spot, constant voltage X-ray source mounted on a gantry with a source-to-isocenter distance of 35 cm. Gantry rotation is limited to 120 degrees from vertical. X-rays of 80-100 kVp from the smaller 0.4-mm focal spot are used for imaging. Both 0.4-mm and 3.0-mm focal spots operate at 225 kVp for irradiation. Robotic translate/rotate stages are used to position the animal. Cone-beam computed tomography is achieved by rotating the horizontal animal between the stationary X-ray source and a flat-panel detector. The radiation beams range from 0.5 mm in diameter to 60 x 60 mm(2). Dosimetry is measured with radiochromic films. Monte Carlo dose calculations are used for treatment planning. The combination of gantry and robotic stage motions facilitate conformal irradiation. RESULTS The SARRP spans 3 ft x 4 ft x 6 ft (width x length x height). Depending on the filtration, the isocenter dose outputs at a 1-cm depth in water were 22-375 cGy/min from the smallest to the largest radiation fields. The 20-80% dose falloff spanned 0.16 mm. Cone-beam computed tomography with 0.6 x 0.6 x 0.6 mm(3) voxel resolution was acquired with a dose of <1 cGy. Treatment planning was performed at submillimeter resolution. CONCLUSION The capability of the SARRP to deliver highly focal beams to multiple animal model systems provides new research opportunities that more realistically bridge laboratory research and clinical translation.


Molecular Cancer Therapeutics | 2007

Targeting the apoptotic machinery in pancreatic cancers using small-molecule antagonists of the X-linked inhibitor of apoptosis protein

Collins Karikari; Indrajit Roy; Eric Tryggestad; Georg Feldmann; Clemencia Pinilla; Kate Welsh; John C. Reed; Elwood Armour; John Wong; Joseph M. Herman; Dinesh Rakheja; Anirban Maitra

Resistance to apoptosis is a hallmark of many solid tumors, including pancreatic cancers, and may be the underlying basis for the suboptimal response to chemoradiation therapies. Overexpression of a family of inhibitor of apoptosis proteins (IAP) is commonly observed in pancreatic malignancies. We determined the therapeutic efficacy of recently described small-molecule antagonists of the X-linked IAP (XIAP) in preclinical models of pancreatic cancer. Primary pancreatic cancers were assessed for XIAP expression by immunohistochemistry, using a pancreatic cancer tissue microarray. XIAP small-molecule antagonists (“XAntag”; compounds 1396-11 and 1396-12) and the related compound 1396-28 were tested in vitro in a panel of human pancreatic cancer cell lines (Panc1, Capan1, and BxPC3) and in vivo in s.c. xenograft models for their ability to induce apoptosis and impede neoplastic growth. In addition, pancreatic cancer cell lines were treated with XAntags in conjunction with either tumor necrosis factor–related apoptosis-inducing ligand (TRAIL) or with radiation to determine potential synergy for such dual targeting of the apoptotic machinery. XIAP was overexpressed in 14 of 18 (77%) of primary pancreatic cancers. The XAntags1396-11 and 1396-12, but not the inactive isomer 1396-28, induced profound apoptosis in multiple pancreatic cancer cell lines tested in vitro, with a IC50 in the range of 2 to 5 μmol/L. Mechanistic specificity of the XAntags for the baculoviral IAP repeat-2 domain of XIAP was shown by preferential activation of downstream “effector” caspases (caspase-3 and caspase-7) versus the upstream “initiator” caspase-9. S.c. BxPC3 xenograft growth in athymic mice was significantly inhibited by monotherapy with XAntags; treated xenografts showed marked apoptosis and increased cleavage of caspase-3. Notably, striking synergy was demonstrable when XAntags were combined with either TRAIL or radiation therapy, as measured by growth inhibition in vitro and reduced colony formation in soft agar of pancreatic cancer cell lines, at dosages where these therapeutic modalities had minimal to modest effects when used alone. Finally, XAntags in combination with the standard-of-care agent for advanced pancreatic cancer, gemcitabine, resulted in significantly greater inhibition of in vitro growth than gemcitabine alone. Our results confirm that pharmacologic inhibition of XIAP is a potent therapeutic modality in pancreatic cancers. These antagonists are independently capable of inducing pancreatic cancer cell death and also show synergy when combined with proapoptotic ligands (TRAIL), with radiation, and with a conventional antimetabolite, gemcitabine. These preclinical results suggest that targeting of the apoptotic machinery in pancreatic cancers with XAntags is a promising therapeutic option that warrants further evaluation. [Mol Cancer Ther 2007;6(3):957–66]


Physics in Medicine and Biology | 2007

The small-animal radiation research platform (SARRP): dosimetry of a focused lens system

Hua Deng; Christopher W. Kennedy; Elwood Armour; Erik Tryggestad; Eric W. Ford; T.R. McNutt; Licai Jiang; John Wong

A small animal radiation platform equipped with on-board cone-beam CT and conformal irradiation capabilities is being constructed for translational research. To achieve highly localized dose delivery, an x-ray lens is used to focus the broad beam from a 225 kVp x-ray tube down to a beam with a full width half maximum (FWHM) of approximately 1.5 mm in the energy range 40-80 keV. Here, we report on the dosimetric characteristics of the focused beam from the x-ray lens subsystem for high-resolution dose delivery. Using the metric of the average dose within a 1.5 mm diameter area, the dose rates at a source-to-surface distance (SSD) of 34 cm are 259 and 172 cGy min(-1) at 6 mm and 2 cm depths, respectively, with an estimated uncertainty of +/-5%. The per cent depth dose is approximately 56% at 2 cm depth for a beam at 34 cm SSD.


Anesthesia & Analgesia | 2009

A novel process for introducing a new intraoperative program: A multidisciplinary paradigm for mitigating hazards and improving patient safety

Jose Rodriguez-Paz; Lynette J. Mark; Kurt R. Herzer; James D. Michelson; Kelly L. Grogan; Joseph M. Herman; David Hunt; Linda Wardlow; Elwood Armour; Peter J. Pronovost

BACKGROUND: Since the Institute of Medicine’s report, To Err is Human, was published, numerous interventions have been designed and implemented to correct the defects that lead to medical errors and adverse events; however, most efforts were largely reactive. Safety, communication, team performance, and efficiency are areas of care that attract a great deal of attention, especially regarding the introduction of new technologies, techniques, and procedures. We describe a multidisciplinary process that was implemented at our hospital to identify and mitigate hazards before the introduction of a new technique: high-dose-rate intraoperative radiation therapy, (HDR-IORT). METHODS: A multidisciplinary team of surgeons, anesthesiologists, radiation oncologists, physicists, nurses, hospital risk managers, and equipment specialists used a structured process that included in situ clinical simulation to uncover concerns among care providers and to prospectively identify and mitigate defects for patients who would undergo surgery using the HDR-IORT technique. RESULTS: We identified and corrected 20 defects in the simulated patient care process before application to actual patients. Subsequently, eight patients underwent surgery using the HDR-IORT technique with no recurrence of simulation-identified or unanticipated defects. CONCLUSION: Multiple benefits were derived from the use of this systematic process to introduce the HDR-IORT technique; namely, the safety and efficiency of care for this select patient population was optimized, and this process mitigated harmful or adverse events before the inclusion of actual patients. Further work is needed, but the process outlined in this paper can be universally applied to the introduction of any new technologies, treatments, or procedures.


Cancer Biology & Therapy | 2013

Novel Hsp90 inhibitor NVP-AUY922 radiosensitizes prostate cancer cells

Nishant Gandhi; Aaron T. Wild; Sivarajan T. Chettiar; Khaled Aziz; Yoshinori Kato; Rajendra P. Gajula; Russell Williams; Jessica Cades; Anvesh Annadanam; Danny Y. Song; Yonggang Zhang; Russell K. Hales; Joseph M. Herman; Elwood Armour; Theodore L. DeWeese; Edward M. Schaeffer; Phuoc T. Tran

Outcomes for poor-risk localized prostate cancers treated with radiation are still insufficient. Targeting the “non-oncogene” addiction or stress response machinery is an appealing strategy for cancer therapeutics. Heat-shock-protein-90 (Hsp90), an integral member of this machinery, is a molecular chaperone required for energy-driven stabilization and selective degradation of misfolded “client” proteins, that is commonly overexpressed in tumor cells. Hsp90 client proteins include critical components of pathways implicated in prostate cancer cell survival and radioresistance, such as androgen receptor signaling and the PI3K-Akt-mTOR pathway. We examined the effects of a novel non-geldanamycin Hsp90 inhibitor, AUY922, combined with radiation (RT) on two prostate cancer cell lines, Myc-CaP and PC3, using in vitro assays for clonogenic survival, apoptosis, cell cycle distribution, γ-H2AX foci kinetics and client protein expression in pathways important for prostate cancer survival and radioresistance. We then evaluated tumor growth delay and effects of the combined treatment (RT-AUY922) on the PI3K-Akt-mTOR and AR pathways in a hind-flank tumor graft model. We observed that AUY922 caused supra-additive radiosensitization in both cell lines at low nanomolar doses with enhancement ratios between 1.4–1.7 (p < 0.01). RT-AUY922 increased apoptotic cell death compared with either therapy alone, induced G2-M arrest and produced marked changes in client protein expression. These results were confirmed in vivo, where RT-AUY922 combination therapy produced supra-additive tumor growth delay compared with either therapy by itself in Myc-CaP and PC3 tumor grafts (both p < 0.0001). Our data suggest that combined RT-AUY922 therapy exhibits promising activity against prostate cancer cells, which should be investigated in clinical studies.


Brachytherapy | 2011

Robotic needle guide for prostate brachytherapy: Clinical testing of feasibility and performance

Danny Y. Song; Everette Clif Burdette; Jonathan Fiene; Elwood Armour; Gernot Kronreif; Anton Deguet; Zhe Zhang; Iulian Iordachita; Gabor Fichtinger; Peter Kazanzides

PURPOSE Optimization of prostate brachytherapy is constrained by tissue deflection of needles and fixed spacing of template holes. We developed and clinically tested a robotic guide toward the goal of allowing greater freedom of needle placement. METHODS AND MATERIALS The robot consists of a small tubular needle guide attached to a robotically controlled arm. The apparatus is mounted and calibrated to operate in the same coordinate frame as a standard template. Translation in x and y directions over the perineum ±40 mm are possible. Needle insertion is performed manually. RESULTS Five patients were treated in an institutional review board-approved study. Confirmatory measurements of robotic movements for initial 3 patients using infrared tracking showed mean error of 0.489 mm (standard deviation, 0.328 mm). Fine adjustments in needle positioning were possible when tissue deflection was encountered; adjustments were performed in 54 (30.2%) of 179 needles placed, with 36 (20.1%) of 179 adjustments of >2mm. Twenty-seven insertions were intentionally altered to positions between the standard template grid to improve the dosimetric plan or avoid structures such as pubic bone and blood vessels. CONCLUSIONS Robotic needle positioning provided a means of compensating for needle deflections and the ability to intentionally place needles into areas between the standard template holes. To our knowledge, these results represent the first clinical testing of such a system. Future work will be incorporation of direct control of the robot by the physician, adding software algorithms to help avoid robot collisions with the ultrasound, and testing the angulation capability in the clinical setting.


The Journal of Nuclear Medicine | 2012

Tumor Dosimetry and Response for 153Sm-Ethylenediamine Tetramethylene Phosphonic Acid Therapy of High-Risk Osteosarcoma

Srinivasan Senthamizhchelvan; R. Hobbs; Hong Song; Eric C. Frey; Zhe Zhang; Elwood Armour; Richard Wahl; David M. Loeb; George Sgouros

153Sm-ethylenediamine tetramethylene phosphonic acid (153Sm-EDTMP) therapy for osteosarcoma is being investigated. In this study, we analyzed the influence of 153Sm-EDTMP administered activity (AA), osteosarcoma tumor density, mass, and the shape of the tumor on absorbed dose (AD). We also studied the biologic implication of the nonuniform tumor AD distribution using radiobiologic modeling and examined the relationship between tumor AD and response. Methods: Nineteen tumors in 6 patients with recurrent, refractory osteosarcoma enrolled in a phase I or II clinical trial of 153Sm-EDTMP were analyzed using the 3-dimensional radiobiologic dosimetry (3D-RD) software package. Patients received a low dose of 153Sm-EDTMP (37.0–51.8 MBq/kg), followed on hematologic recovery by a second, high dose (222 MBq/kg). Treatment response was evaluated using either CT or MRI after each therapy. SPECT/CT of the tumor regions were obtained at 4 and 48 h or 72 h after 153Sm-EDTMP therapy for 3D-RD analysis. Mean tumor AD was also calculated using the OLINDA/EXM unit-density sphere model and was compared with the 3D-RD estimates. Results: On average, a 5-fold increase in the AA led to a 4-fold increase in the mean tumor AD over the high- versus low-dose–treated patients. The range of mean tumor AD and equivalent uniform dose (EUD) for low-dose therapy were 1.48–14.6 and 0.98–3.90 Gy, respectively. Corresponding values for high-dose therapy were 2.93–59.3 and 1.89–12.3 Gy, respectively. Mean tumor AD estimates obtained from OLINDA/EXM were within 5% of the mean AD values obtained using 3D-RD. On an individual tumor basis, both mean AD and EUD were positively related to percentage tumor volume reduction (P = 0.031 and 0.023, respectively). Conclusion: The variations in tumor density, mass, and shape seen in these tumors did not affect the mean tumor AD estimation significantly. The tumor EUD was approximately 2- and 3-fold lower than the mean AD for low- and high-dose therapy, respectively. A dose–response relationship was observed for transient tumor volume shrinkage.


medical image computing and computer assisted intervention | 2007

Intra-operative 3D guidance in prostate brachytherapy using a non-isocentric C-arm

Ameet Kumar Jain; Anton Deguet; Iulian Iordachita; Gouthami Chintalapani; J. Blevins; Yi Le; Elwood Armour; Clif Burdette; Danny Y. Song; Gabor Fichtinger

Intra-operative guidance in Transrectal Ultrasound (TRUS) guided prostate brachytherapy requires localization of inserted radioactive seeds relative to the prostate. Seeds were reconstructed using a typical C-arm, and exported to a commercial brachytherapy system for dosimetry analysis. Technical obstacles for 3D reconstruction on a non-isocentric C-arm included pose-dependent C-arm calibration; distortion correction; pose estimation of C-arm images; seed reconstruction; and C-arm to TRUS registration. In precision-machined hard phantoms with 40-100 seeds, we correctly reconstructed 99.8% seeds with a mean 3D accuracy of 0.68 mm. In soft tissue phantoms with 45-87 seeds and clinically realistic 15 degrees C-arm motion, we correctly reconstructed 100% seeds with an accuracy of 1.3 mm. The reconstructed 3D seed positions were then registered to the prostate segmented from TRUS. In a Phase-1 clinical trial, so far on 4 patients with 66-84 seeds, we achieved intra-operative monitoring of seed distribution and dosimetry. We optimized the 100% prescribed iso-dose contour by inserting an average of 3.75 additional seeds, making intra-operative dosimetry possible on a typical C-arm, at negligible additional cost to the existing clinical installation.


International Journal of Surgical Oncology | 2012

Clinicopathologic Comparison of High-Dose-Rate Endorectal Brachytherapy versus Conventional Chemoradiotherapy in the Neoadjuvant Setting for Resectable Stages II and III Low Rectal Cancer

Jessica A. Smith; Aaron T. Wild; Aatur D. Singhi; Siva P. Raman; Haoming Qiu; Rachit Kumar; Amy Hacker-Prietz; Ralph H. Hruban; Ihab R. Kamel; Jonathan E. Efron; Elizabeth C. Wick; Nilofer Saba Azad; Luis A. Diaz; Yi Le; Elwood Armour; Susan L. Gearhart; Joseph M. Herman

Purpose. To assess for differences in clinical, radiologic, and pathologic outcomes between patients with stage II-III rectal adenocarcinoma treated neoadjuvantly with conventional external beam radiotherapy (3D conformal radiotherapy (3DRT) or intensity-modulated radiotherapy (IMRT)) versus high-dose-rate endorectal brachytherapy (EBT). Methods. Patients undergoing neoadjuvant EBT received 4 consecutive daily 6.5 Gy fractions without chemotherapy, while those undergoing 3DRT or IMRT received 28 daily 1.8 Gy fractions with concurrent 5-fluorouracil. Data was collected prospectively for 7 EBT patients and retrospectively for 25 historical 3DRT/IMRT controls. Results. Time to surgery was less for EBT compared to 3DRT and IMRT (P < 0.001). There was a trend towards higher rate of pathologic CR for EBT (P = 0.06). Rates of margin and lymph node positivity at resection were similar for all groups. Acute toxicity was less for EBT compared to 3DRT and IMRT (P = 0.025). Overall and progression-free survival were noninferior for EBT. On MRI, EBT achieved similar complete response rate and reduction in tumor volume as 3DRT and IMRT. Histopathologic comparison showed that EBT resulted in more localized treatment effects and fewer serosal adhesions. Conclusions. EBT offers several practical benefits over conventional radiotherapy techniques and appears to be at least as effective against low rectal cancer as measured by short-term outcomes.


Brachytherapy | 2011

Dynamic intraoperative dosimetry for prostate brachytherapy using a nonisocentric C-arm

Danny Y. Song; Ameet Kumar Jain; Zhe Zhang; Anton Deguet; Yi Le; Elwood Armour; E. Clif Burdette; Gabor Fichtinger

PURPOSE To evaluate a prototypical system of dynamic intraoperative dosimetry for prostate brachytherapy using registered ultrasound and fluoroscopy (RUF) with a nonisocentric C-arm (GE OEC, Salt Lake City, UT) and to compare intraoperative dosimetry of RUF as well as ultrasound-based seed localization (USD) with Day 0 CT dosimetry. METHODS Seed positions were independently determined using RUF and USD. RUF uses a radio-opaque fiducial for registration to ultrasound and 3-dimensional reconstruction of seeds relative to prostate using nonisocentric C-arm fluoroscopy. Postimplant CT was performed on Day 0. Squared differences between dosimetric measures for RUF vs. CT and USD vs. CT were calculated and mean squared differences evaluated. Paired t test was used to evaluate which method was more closely aligned with CT. Accuracies of USD and RUF compared with CT were estimated using a nonparametric approach. RESULTS Six patients were treated and compared with USD. RUF identified areas of underdosage intraoperatively in all patients and median 5 additional seeds were placed. In 40 of 42 measures, RUF was equally or more closely correlated with CT than USD. USD showed statistically significant variation from CT for 6 of 7 parameters compared with 1 of 7 parameters for RUF. Mean squared differences from CT were significantly smaller for RUF in 4 of 7 parameters compared with USD. CONCLUSIONS Dynamic intraoperative dosimetry is possible with a conventional nonisocentric C-arm. Compared with an USD method, RUF-based intraoperative dosimetry was more closely aligned with immediate postimplant CT. RUF identified areas of underdosage, which were not detected using USD.

Collaboration


Dive into the Elwood Armour's collaboration.

Top Co-Authors

Avatar

Yi Le

Johns Hopkins University

View shared research outputs
Top Co-Authors

Avatar

John Wong

Johns Hopkins University

View shared research outputs
Top Co-Authors

Avatar

Joseph M. Herman

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

T.R. McNutt

Johns Hopkins University

View shared research outputs
Top Co-Authors

Avatar

Danny Y. Song

Johns Hopkins University School of Medicine

View shared research outputs