Elżbieta M. Grabczak
Medical University of Warsaw
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Elżbieta M. Grabczak.
Respiration | 2012
Hanna Grubek-Jaworska; Magdalena Paplińska; Joanna Hermanowicz-Salamon; Katarzyna Białek-Gosk; Marta Dąbrowska; Elżbieta M. Grabczak; Joanna Domagała-Kulawik; Julita Stępień; Ryszrda Chazan
Background: IL-6 is strongly implicated in the development of chronic obstructive pulmonary disease (COPD). IL-13 is the well-documented central mediator in allergic asthma. IL-6 is attributed to the proinflammatory activities in COPD as well as asthma. In COPD patients exacerbation is increased by serum IL-6. The association of IL-13 as well as IL-6 with the impaired respiratory function of asthma patients remains controversial. Objectives: The aim of this study was to compare the concentration of IL-6 and IL-13 in the induced sputum of asthma and COPD patients, and to assess the possible association of these cytokines with the impairment of lung function. Methods: Twenty-six subjects with COPD and 18 subjects with asthma were enrolled in this study. IL-6 and IL-13 levels were measured in induced sputum by ELISA and correlated with the results of respiratory tests. Results: The induced sputum of COPD patients had a significantly higher IL-6 level than the sputum of asthma subjects while no significant differences were found in the levels of IL-13. There was a statistically significant negative correlation between IL-6 level and FEV1 or FEV1/FVC in asthma patients (r = –0.59 and –0.54, respectively) and a negative correlation that did not reach statistical significance between IL-6 level and FEV1, FEV1% or FVC in COPD subjects (r = –0.30, –0.30 and –0.38, respectively). There was no relationship between concentrations of IL-13 and impaired respiratory function. Conclusions: Our results confirmed that IL-6, but not of IL-13, is associated with respiratory disorders in both asthma and COPD patients.
The Scientific World Journal | 2011
Rafał Krenke; Elżbieta M. Grabczak
Human lungs are constantly exposed to a large number of Aspergillus spores which are present in ambient air. These spores are usually harmless to immunocompetent subjects but can produce a symptomatic disease in patients with impaired antifungal defense. In a small percentage of patients, the trachea and bronchi may be the main or even the sole site of Aspergillus infection. The clinical entities that may develop in tracheobronchial location include saprophytic, allergic and invasive diseases. Although this review is focused on invasive Aspergillus tracheobronchial infections, some aspects of allergic and saprophytic tracheobronchial diseases are also discussed in order to present the whole spectrum of tracheobronchial aspergillosis. To be consistent with clinical practice, an approach basing on specific conditions predisposing to invasive Aspergillus tracheobronchial infections is used to present the differences in the clinical course and prognosis of these infections. Thus, invasive or potentially invasive Aspergillus airway diseases are discussed separately in three groups of patients: (1) lung transplant recipients, (2) highly immunocompromised patients with hematologic malignancies and/or patients undergoing hematopoietic stem cell transplantation, and (3) the remaining, less severely immunocompromised patients or even immunocompetent subjects.
Chest | 2009
Sebastian Stec; Elżbieta M. Grabczak; Piotr Bielicki; Beata Zaborska; Rafał Krenke; Tomasz Kryński; Marta Dąbrowska; Joanna Domagała-Kulawik; Anna Domeracka-Kołodziej; Agnieszka Sikorska; Piotr Kulakowski; Ryszarda Chazan
BACKGROUND Chronic cough frequently remains unexplained. Although various cardiac arrhythmias have already been reported as a cause of chronic cough, this phenomenon has not been evaluated prospectively. Therefore, we studied the incidence and management of cough associated with premature ventricular complexes (PVCs) in a population of patients with this condition. METHODS Patients without organic heart disease who had been referred for the management of symptomatic PVC were evaluated prospectively. PVC-associated cough was recognized if cough episodes occurred just after spontaneous or induced PVC or observed in an ECG or a multichannel recording system that included ECG. A differential diagnosis of cough was performed according to the guidelines on cough. Afterward, antiarrhythmic therapy was instituted to eliminate PVC and cough. RESULTS Of the 120 patients who were referred for the management of PVC, 10 had a chronic cough. After extensive workup for the cause of chronic cough, the cough was thought to be solely due to PVC in one patient, partially due to PVC plus another cause in five patients, and not due to PVC but to nonasthmatic eosinophilic bronchitis, gastroesophageal reflux disease, and chronic sinusitis in four patients. Patients with PVC-associated cough reported more severe perception of symptoms associated with arrhythmia than patients without cough (mean [+/- SD] visual analog scale score, 8.2 +/- 0.5 vs 5.7 +/- 1.6, respectively; p < 0.01). PVC-associated cough disappeared after antiarrhythmic treatment (radiofrequency ablation [n = 4], oral antiarrhythmic agent [n = 1]), or after spontaneous remission of PVC (n = 1). CONCLUSIONS PVC may be a cause of chronic cough. Interdisciplinary cooperation is warranted for the proper diagnosis and management of PVC-associated cough.
Respiration | 2011
Rafał Krenke; Maciej Guć; Elżbieta M. Grabczak; Marcin Michnikowski; K. J. Pałko; Ryszarda Chazan; Tomasz Gólczewski
Background: Measurement of intrapleural pressure is useful during various pleural procedures. However, a pleural manometer is rarely available. Objectives: The aim of this study was to (1) construct an electronic pleural manometer, (2) assess the accuracy of the measurements done with the new device, (3) calculate the costs of the manometer construction and (4) perform an initial evaluation of the device in a clinical setting. Methods: Only widely accessible elements were used to construct the device. A vascular pressure transducer was used to transform pressure into an electronic signal. Reliability of the measurements was evaluated in a laboratory setting in a prospective, single-blind manner by comparing the results with those measured by a water manometer. Functionality of the device was assessed during therapeutic thoracentesis. The cost of the new pleural manometer was calculated. Results: We built a small, portable device which can precisely measure intrapleural pressure. The measurement results showed very high agreement with those registered with a water manometer (r = 0.999; p < 0.001). The initial evaluation of the electronic manometer during therapeutic thoracentesis showed it was easy to use. The total time needed for 6 measurements after withdrawal of different volumes of pleural fluid in 1 patient did not exceed 6 min. The total cost of the device was calculated to be <2,000 EUR. Conclusions: In the face of very limited offer of commercially available pleural manometers, it is possible to successfully construct a self-made, reliable, electronic pleural manometer at modest costs. The device is easy to use and enables data display and storage in the personal computer.
Respirology | 2015
Monika Zielinska-Krawczyk; Marcin Michnikowski; Elżbieta M. Grabczak; K. J. Pałko; Piotr Korczynski; Tomasz Gólczewski; Rafał Krenke
We report intriguing preliminary observations on the effect of cough on pleural pressure changes during therapeutic thoracentesis. We found that cough‐related elevation of pleural pressure persisted even when the cough had stopped. Thus, we hypothesize that cough during therapeutic thoracentesis may have a beneficial effect preventing the excessive drop in pleural pressure. The true role of cough‐related elevation of pleural pressure is unknown, but it seems to be an interesting subject for further research.
Respiratory Medicine | 2018
Elżbieta M. Grabczak; Rafał Krenke; Monika Zielinska-Krawczyk; Richard W. Light
Although pleural manometry is a relatively simple medical procedure it is only occasionally used to follow pleural pressure (Ppl) changes during a therapeutic thoracentesis and pneumothorax drainage. As some studies showed that pleural pressure monitoring might be associated with significant advantages, pleural manometry has been increasingly evaluated in the last decade. The major clinical applications of pleural pressure measurements include: the prevention of complications associated with large volume thoracentesis, diagnosis and differentiation between various types of an unexpandable lung and a possible prediction of the efficacy of chest tube drainage in patients with spontaneous pneumothorax. It is well known that the therapeutic thoracentesis might be complicated by cough, chest discomfort, and rarely, by a life threatening condition called reexpansion pulmonary edema (RPE). The serious adverse events of thoracentesis are related to pleural pressure drop rather than to the volume of removed pleural effusion. The use of pleural manometry during pleural fluid withdrawal enables the evaluation of the relationship between withdrawn pleural fluid volume, pleural pressure changes and procedure related complications. Pleural pressure measurement is also an important tool to study the different mechanism of pneumothorax complicating the thoracentesis. Pleural manometry is critical for measurement of pleural elastance, diagnosis of an unexpandable lung and differentiation between trapped lung and lung entrapment. This usually has significant clinical implications in terms of further management of patients with pleural effusion. The paper is a comprehensive review presenting different aspects of pleural pressure measurement in clinical practice.
Archives of Medical Science | 2014
Marta Dąbrowska; Elżbieta M. Grabczak; Magdalena Arcimowicz; Anna Domeracka-Kołodziej; Joanna Domagała-Kulawik; Rafał Krenke; Marta Maskey-Warzęchowska; Bożena Tarchalska-Kryńska; Paulina Krasnodębska; Ryszarda Chazan
Introduction Efficacy of chronic cough treatment is ambiguous. The aim of the study was to analyze chronic cough alleviation after specific treatment and the relationship between cough etiology and treatment efficacy. Material and methods A stepwise diagnostic approach was used to diagnose cough etiology in non-smoking adults with chronic cough. In all patients specific treatment was applied. Two different questionnaires – a visual analog scale and a 5-degree scale – were used to assess cough severity before and after 4-6 months of treatment. Results A significant correlation between pre-treatment and post-treatment results of both questionnaires was found (Spearman coefficient 0.43, p = 0.0003 and 0.73, p < 0.0001, respectively). Baseline questionnaire analysis revealed no differences in cough severity between patients with different cough causes or multiple cough causes. Although specific treatment resulted in a significant decrease of cough severity in the entire group, only partial improvement was noted. According to the visual analogue scale, a decrease of cough severity by at least 50% was achieved only in 54.4% of patients (37/68). Similarly, satisfactory improvement was noted in only 54.4% (37/68) of patients when using the 5-point scale. There were three sub-groups of patients, in whom no relevant decrease of cough severity was observed despite treatment: patients with 1. three coexisting cough causes, 2. non-asthmatic eosinophilic bronchitis, and 3. chronic idiopathic cough. Conclusions Cough severity does not depend on its etiology. Efficacy of chronic cough treatment in non-smoking patients is only moderate.
International Journal of Artificial Organs | 2017
Tomasz Gólczewski; Anna Stecka; Marcin Michnikowski; Elżbieta M. Grabczak; Piotr Korczynski; Rafał Krenke
Purpose Influence of therapeutic thoracentesis on the pleural pressure (Pp) has been discussed in many clinical studies, however reasons of Pp changes are not precisely established. The aim of the study was to use a previously elaborated virtual cardiopulmonary patient (VP) in analysis of impact of physiological factors on Pp during the procedure. Methods Simulations were performed on VP with default values of parameters for which VP simulated the respiratory system of the average 50-year-old healthy Polish woman according to spirometric examination. Alterations of Pp and the amplitude of Pp changes related to breathing (AP) were analyzed. Model parameters related to chosen factors were deviated from their default values to analyze the degree of their impact on Pp and AP. The analysis was based on and supported by our own clinical data. Results The Pp and AP alteration intensity appeared to be most sensitive to the compliances of the rib cage and mediastinum, and the nonlinearity of the dependence between the recoil pressure and the lung volume: the lower the compliances and the higher the nonlinearity were, the deeper the Pp fall during the procedure and the bigger the AP increase were observed. Conclusions Experiments in silico are very useful in analyzing sophisticated physiological and medical problems. They made it possible to show which factors are particularly responsible for changes in Pp during thoracentesis. In the future, they may be useful in establishing objective conditions under which thoracentesis needs to be stopped.
Advances in Experimental Medicine and Biology | 2015
Marta Dąbrowska; Elżbieta M. Grabczak; Magdalena Arcimowicz; Anna Domeracka-Kołodziej; Joanna Domagała-Kulawik; Rafał Krenke; Marta Maskey-Warzęchowska; B. Tarchalska; Ryszarda Chazan
Chronic cough is a common medical problem. The aim of the study was to analyze chronic cough causes in non-smoking patients and to search for demographic factors associated with different cough reasons. The etiology of cough was determined by medical history, diagnostic tests and response to specific treatment. Patients with significant abnormalities in the chest radiograph or spirometry were not included. The study included 131 non-smoking patients; median age 54 years, 77 % female. The most frequent causes of cough were gastroesophageal reflux disease (GERD) (62 %) and upper airway cough syndrome (UACS) (46 %). Cough variant asthma and non-asthmatic eosinophilic bronchitis (NAEB) were diagnosed in 32 (25 %) and 19 (15 %) patients, respectively. Other cough causes were found in 27 patients (21 %). Asthma was a significantly more common cause of chronic cough in women than in men (31 % vs. 3 %, p = 0.005). A reverse relationship was demonstrated for UACS (39 % vs. 67 %, p = 0.01). Patients with chronic cough aged >50 yrs were more likely to be diagnosed with less common cough causes. In conclusion, the most common chronic cough reasons are GERD and UACS. Asthma-related cough is diagnosed more frequently in females, while UACS-related cough is more frequent in males.
Respiratory Medicine | 2018
Monika Zielinska-Krawczyk; Rafał Krenke; Elżbieta M. Grabczak; Richard W. Light
Subatmospheric pleural pressure (Ppl), which is approximately -3 to -5 cmH2O at functional residual capacity (FRC) makes pleura a unique organ in the human body. The negative Ppl is critical for maintaining the lungs in a properly inflated state and for proper blood circulation within the thorax. Significant and sudden pleural pressure changes associated with major pleural pathologies, as well as therapeutic interventions may be associated with life-threatening complications. The pleural pressure may show two different values depending on the measurement method applied. These are called pleural liquid pressure and pleural surface pressure. It should also be realized that there are significant differences in pleural pressure distribution in pneumothorax and pleural effusion. In pneumothorax, the pressure is the same throughout the pleural space, while in pleural effusion there is a vertical gradient of approximately 1 cm H2O/cm in the pleural pressure associated with the hydrostatic pressure of the fluid column. Currently, two main methods of pleural pressure measurement are used: simple water manometers and electronic systems. The water manometers are conceptually simple, cheap and user-friendly but they only allow the estimation of the mean values of pleural pressure. The electronic systems for pleural pressure measurement are based on pressure transducers. Their major advantages include precise measurements of instantaneous pleural pressure and the ability to display and to store a large amount of data. The paper presents principles and details of pleural pressure measurement as well as the rationale for its use.