Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Emiko Shimamura is active.

Publication


Featured researches published by Emiko Shimamura.


Journal of Cataract and Refractive Surgery | 2007

Influence of the signal-to-noise ratio on the accuracy of IOLMaster measurements

Chikako Suto; Chiaki Sato; Emiko Shimamura; Hiroshi Toshida; Kazuo Ichikawa; Sadao Hori

PURPOSE: To evaluate the relationship between the sound‐to‐noise ratio (SNR) and the reliability of axial length (AL) measurements obtained with the IOLMaster (Carl Zeiss Meditec AG). SETTING: Department of Ophthalmology, Saiseikai Kurihashi Hospital, Saitama, Japan. METHODS: In a clinical prospective study, 216 consecutive eyes of 144 patients scheduled for cataract surgery were evaluated for the type and severity of cataract using the Lens Opacities Classification System III. Preoperative and postoperative AL measurements were performed with the IOLMaster. The preoperative SNR values were used to divide the eyes into 5 groups. The following were compared between the groups: preoperative logMAR best spectacle‐corrected visual acuity (BSCVA), difference in AL between preoperatively and postoperatively, error in the postoperative predicted refraction, and type and severity of cataract. RESULTS: The preoperative logMAR BSCVA was significantly worse in eyes with an SNR <2 (P<.05). The AL was longer preoperatively than postoperatively in all groups, and there was a significant difference in the <2 SNR group and the 2 to <5 group (P<.05). There were no significant differences in the error in postoperative predicted refraction. The percentage of patients with P4 or worse posterior subcapsular cataract (PSC) increased significantly with a decrease in the SNR (P<.01). However, there was no correlation between nuclear color grade and the SNR. CONCLUSION: The SNR value was useful in confirming the good quality of AL readings taken with the IOLMaster, even though the SNR value correlated significantly with the preoperative logMAR BSCVA and PSC severity.


Journal of Cataract and Refractive Surgery | 2015

Comparison of 2 optical biometers and evaluation of the Camellin-Calossi intraocular lens formula for normal cataractous eyes.

Chikako Suto; Emiko Shimamura; Itsumi Watanabe

Purpose To compare the measurements and intraocular lens (IOL) power calculations obtained with an optical biometer (AL‐Scan) and partial coherence interferometry (PCI) device (IOLMaster 500), and to evaluate the accuracy of the Camellin‐Calossi IOL formula in virgin eyes. Setting Saiseikai Kurihashi Hospital, Saitama, Japan. Design Prospective comparative study. Methods Measurements were compared from 262 patients (450 eyes) scheduled for cataract surgery. Axial length (AL), keratometry (K), anterior chamber depth (ACD), and number of eyes that were successfully measured were compared. Comparisons were performed of the residual postoperative refractive error with the SRK/T, Haigis, and Camellin‐Calossi IOL formulas with optical biometer data. The IOL constant was optimized for 81 eyes that had iSertMicro 251 IOL implantation. Results The mean difference in AL between biometers was −0.012 mm ± 0.031 (SD) (P < .0001). Correlation coefficients (r) for AL, keratometry, and ACD were 0.9997, 0.9836, and 0.9571, respectively. The calculated IOL constant for the Camellin‐Calossi formula was 119.3. The optimized IOL constant for the SRK/T was 118.8, the same as that of the User Group for Laser Interference Biometry for the PCI device. For the Haigis formula, only a0 was optimized, and it was 1.390. After optimizing the A‐constant for the Camellin‐Calossi formula, the residual postoperative refractive error of the Camellin‐Calossi formula was not statistically significantly different in comparison to those obtainied with the Haigis and SRK/T formulas. Conclusion Ocular biometry measurements were equivalent for both devices, indicating that the AL‐Scan can be used for routine preoperative cataract assessment. The predictive accuracy of the Camellin‐Calossi formula included in the optical biometer was equivalent to common IOL formulas for virgin eyes. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned.


Japanese orthoptic journal | 2005

Postoperative outcomes using IOLMaster™ with varying signal-to-noise ratios (SNR)

Chiaki Sato; Chikako Suto; Emiko Shimamura; Sachiko Kuraoka


Japanese orthoptic journal | 2015

Relation Between Corneal Astigmatism and Uncorrected Visual Acuity in Eyes Implanted With Multifocal Intraocular Lens

Eri Hiruta; Chikako Suto; Emiko Shimamura; Itsumi Watanabe; Chihiro Kobayashi


Japanese orthoptic journal | 2014

Determination of Intraocular Lens Power in Eyes with Corneas in Distorted Shapes

Itsumi Watanabe; Chikako Suto; Emiko Shimamura; Eri Hiruta; Yuta Fuchie


Japanese orthoptic journal | 2013

Influence of Entries of Preoperative Refraction and Lens Thickness on the Postoperative Outcomes of the Holladay 2 Formula

Yuta Fuchie; Chikako Suto; Emiko Shimamura; Itsumi Watanabe; Eri Ohno


Japanese orthoptic journal | 2012

Evaluation of A-mode Immersion Ultrasound Biometry in Substitution for the IOLMaster^|^reg; in Eyes With Unmeasurable Axial Length by the IOLMaster^|^reg;

Eri Ohno; Chikako Suto; Emiko Shimamura; Itsumi Watanabe; Yuta Fuchie


Japanese orthoptic journal | 2007

Comparison of Axial Lengths Measured by Central-, Paracentral-, and Defocusing-Methods Using IOLMaster™ on Patients With Cataract

Chiaki Sato; Chikako Suto; Emiko Shimamura; Sachiko Kuraoka


Japanese orthoptic journal | 2006

Effect of misalignment of analytical centers on higher-order aberration

Sachiko Kuraoka; Chikako Suto; Emiko Shimamura; Chiaki Sato; Midori Takahashi


Japanese orthoptic journal | 2004

Relationship between preoperative refractive values and preferred postoperative indices according to axial length

Rika Kikuchi; Chikako Suto; Emiko Shimamura; Satoko Takahashi; Chiaki Sato

Collaboration


Dive into the Emiko Shimamura's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge